• Title/Summary/Keyword: sun position

Search Result 1,304, Processing Time 0.032 seconds

Kinematics Analysis of Lumbar Spine during Breathing in Lying Position (누운 자세에서 호흡에 따른 요추분절의 운동학적 분석)

  • Yuk, Goon-Chang;Park, So-Hyun;Kim, Chung-Sun
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.5
    • /
    • pp.15-21
    • /
    • 2011
  • Purpose: The purpose of this study was to describe the influence of respiration on the segmental motion of the lumbar spine in the lying position. Methods: Twelve healthy females without a history of low back pain participated. Lumbosacral lordosis, intervertebral body angles, intervertebral body displacements, and anterior heights of the intervertebral disc of the lumbar spine were measured at inspiration, expiration and forced expiration in the supine and prone positions via fluoroscopy. Results: The results of lumbar kinematic analysis in the supine position according to respiration pattern were as follows. The L4/5 intervertebral body angle was significantly higher at forced expiration than at expiration (p<0.05). The L3/4 anterior height of the intervertebral disc was significantly higher at expiration than at forced inspiration and the L5/S1 anterior height of the intervertebral disc was significantly higher at inspiration than at forced expiration (p<0.05). There were no significant differences in the intervertebral body displacements and lumbosacral lordosis in the supine position (p>0.05). The results of lumbar kinematic analysis in the prone position according to respiration pattern were as follows. The L5/S1 anterior height of the intervertebral disc was significantly higher at inspiration than at forced expiration (p<0.05). However, there was no significant difference in the intervertebral body angle, the intervertebral body displacements, and the lumbosacral lordosis (p>0.05). Conclusion: These findings suggested that respiration can affect the intervertebral body angle and anterior height of the intervertebral disc in some segments. The results from this study serve as a step in the development of guidelines for lumbar kinematic analysis for lumbar breathing training.

Luminance Correction Algorithm Based on Measuring Angle for the Portable Luminance Measurement System (휴대용 휘도측정시스템의 측정각도기반 휘도보정알고리즘)

  • Sun, Eun-Hey;Kim, Dongyeon;Kim, Yong-Tae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.4
    • /
    • pp.321-326
    • /
    • 2016
  • In this paper, we propose a luminance correction algorithm based on measuring position for potable luminance measurement system. Measurement position and angle have an affect on the luminance value. We improve the position-based luminance measurement system using luminance correction algorithm based on the measuring angle. We analyze change of luminance value according to the measurement distance and angle from camera and light source. The certified point-luminance meter is used to evaluate a scene luminance measuring method using the image information of camera. Also, we derive an expression equation for evaluating luminance value from determined position. The performances of the proposed system are verified by using comparative experiments with the point-luminance meter using experimental signboard.

A Study on Exposure Technics in Roentgenography of the Stomach (위조영촬영시(胃造影撮影時) 촬영조건(撮影條件)에 관(關)한 연구(硏究))

  • Kyong, Kwang-Hyon;Kim, Heung-Tai;Kwon, Dal-Kwan;Sun, Han-Kyung;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.4 no.1
    • /
    • pp.45-53
    • /
    • 1981
  • In examinations of the stomach roentgenography, it is imperative to obtain adequate film density throughout all its different regions. Therefore, it is necessary to use more sophiscated exposure techniques. In order to achieve these purpose, the radiologic technologists must be measured abdominal thickness in variations with patient positions. In consideration of these problem, the author was made an experiment on correction method of kVp and mAs by abdominal thickness in roentgenography of the stomach. The results were summarized as follws: 1. When the patient in erect position, abdominal thickness was the most thickened at the level of 3cm inferior to umbilicus without regard to body habitus and it was the most thickened at the level of 3cm superior to umbilicus in prone and supine position. 2. As a result of measuring film density for stomach, the adequate film density was represented from 0.70 to 2.49 in erect position and $0.28{\sim}1.18$ in supine position, $0.5{\sim}2.45$ in prone position. 3. In order to obtain uniform film density in 1.25, the correction factor for kVp by abdominal thickness was represented average ${\pm}4.5kVp\;per\;{\pm}1cm$ in a fixed 50 mAs, and average ${\pm}3.9kVp\;per\;{\pm}1cm$ in a fixed 100mAs. 4. In order to obtain uniform film density in 1.25, the correction factor for mAs by abdominal thickness was represented average ${\pm}30.9%\;per\;{\pm}1cm$ in a fixed 80 kvp and ${\pm}26.9%\;per\;{\pm}1cm$ in a fixed 100kVp.

  • PDF

The Blood Disappearance Rate of $^{198}Au$-Colloid and Changes of Hepatic Blood Flow During Position Change in Normal Persons and in Patients with Various Hepatic Diseases (정상인(正常人) 및 각종(各種) 간질환(肝疾患) 환자(患者)에서 $^{198}Au$교질(膠質)의 혈중소실율치(血中消失率値)와 체위변동(體位變動)에 따른 간혈류량변화(肝血流量變化)에 관한 연구(硏究))

  • Cho, Bo-Yeon;Hong, Kee-Suck;Koh, Chang-Sun;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.11 no.1
    • /
    • pp.33-37
    • /
    • 1977
  • To evaluate the diagnostic significance of the blood disappearance rate of $^{198}Au$-colloid and to evaluate the change of hepatic blood flow during position change from supine to erect, we measured the half time of blood disappearance rate of $^{198}Au$-colloid using external counting method in 94 normal persons and in 77 patients with various hepatic diseases. The results obtained were as follows: 1. In normal control, the mean blood disappearance half time of $^{198}Au$-colloid in supine position was $2.7{\pm}0.4$ minutes. There was no significant difference of hepatic blood flow in age and sex. 2. In acute hepatitis, chronic hepatitis and hepatic cirrhosis, the mean blood disappearance half times in supine position were $3.0{\pm}0.45,\;3.5{\pm}0.74,\;7.2{\pm}3.6$ minutes respectively. The hepatic blood flow of the patients with chronic hepatitis and hepatic cirrhosis were significantly decreased than that of normal control. 3. In the normal control and acute hepatitis, the decreaces of the hepatic blood flow during the position change from supine to erect were 27.7% and 22.6% respectively.

  • PDF

Immediate Effect of Serratus Posterior Inferior Muscle Direction Taping on Thoracolumbar Junction Rotation Angle During One Arm Lifting in the Quadruped Position

  • Kim, Nu-ri;Ahn, Sun-hee;Gwak, Gyeong-tae;Yoo, Hwa-ik;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.28 no.3
    • /
    • pp.227-234
    • /
    • 2021
  • Background: The serratus posterior inferior (SPI) muscle originates from the spinous process of T11-L2 and inserts at the lower border of the 9-12th ribs. This muscle is involved in thoracolumbar rotation and stability. Several positions can be used to improve trunk stability; the quadruped position is a good position for easily maintaining a neutral spine. In particular, during one arm lifting, various muscles act to maintain a neutral trunk position, and the SPI is one of these muscles. If trunk stability is weakened, uncontrolled trunk rotation may occur at this time. Tape can be used to increase trunk stability. There have been no studies on the effect of taping applied to the SPI muscle on thoracolumbar junction (TLJ) stability. Objects: This study compared the TLJ rotation angle between three different conditions (without taping, transverse taping, and SPI muscle direction taping). Methods: Thirty subjects were recruited to the study (18 males and 12 females). The TLJ rotation angle was measured during one arm lifting in a quadruped position (ALQP). Two taping methods (transverse and SPI muscle direction taping) were applied, and the TLJ rotation angle was measured in the same movement. Results: SPI muscle direction taping significantly reduced TLJ rotation compared to that without taping (p < 0.001) and with transverse taping (p < 0.001). There was a significant difference in the TLJ rotation angle between transverse taping and SPI muscle direction taping (p < 0.017). Conclusion: SPI muscle direction taping reduces the TLJ rotation angle during ALQP. Therefore, SPI muscle direction taping is one method to improve TLJ stability and reduce uncontrolled TLJ rotation during ALQP.

A Study on the Relation between Treatment posture and Musculoskeletal disorders Between Dental hygienist and Dental hygiene student some areas (일부지역 치과위생사와 치위생과 재학생의 진료자세와 통증과의 관계연구)

  • Kwag, Jung-Suk;Jang, Sun-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.7 no.4
    • /
    • pp.381-393
    • /
    • 2007
  • The objectives of this study was to suggest for prophylatic of Musculoskeletal system disorders in Dental Hyginists and Dental hygiene students to maintain good posture in the dental hygiene curriculum. This study was carried with 100 dental hygienists in "M" city located in Jolla Province and 82 college students majoring in dental hygiene. The results were as follows: 1. During the operators' medical treatment, 41.7% answered that the patients' head was located in the operators' chest during their treatment. Also, 58.3% answered that the patients' head was located in the operators' abdomen. For this reason, 81.3% said that the patients' mouth became close to the operators' eyes - less than 30cm. And 65.1% said that they performed an operation in various directions. 2. The most common posture -between the position of operating and the position of assisting- is the position of operationg 1. The position of operationg 1 and 5 have an effect on the waist, and the position of assisting 3 has an effect on pains of the waist, bottoms, knees, ankles and feet. 3. The common symptoms of musculoskeletal system disorders in dental hygienists and student was the neck ache and the shoulders, and was followed by the lower back. From the cases that they visited in health care or apothecary to the above pain, symptoms were highest in the shoulders(18.3%) and were followed by the lower back(13.4%) and neck(9.1%). 4. On The necessity of education related to, According to researches, 96.3% college students and 92.5% dental hygienists answered that education related to Musculoskeletal system disorders is necessary. 5. In this study, I have 3 limitations. First, the subject of survey was selected for specific people in the specific city, Second, the personal judgment was made in judging the relations of the position of operating, the position of assisting and the aches. Third, the relations of the position of operating, the position of assisting and the aches don't have supporting medical evidences. Therefore, this study will be carried on more people with more objectives and medical method.

  • PDF

The Respiratory and Hemodynamic Effects of Prone Position According to the Level of PEEP in a Dog Acute Lung Injury Model (잡종견 급성폐손상 모델에서 Prone position 시행시 PEEP 수준에 따른 호흡 및 혈류역학적 효과)

  • Lim, Chae-Man;Chin, Jae-Yong;Koh, Youn-Suck;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.140-152
    • /
    • 1998
  • Background: Prone position improves oxygenation in patients with ARDS probably by reducing shunt Reduction of shunt in prone position is thought to be effected by lowering of the critical opening pressure (COP) of the dorsal lung because the pleural pressure becomes less positive in prone position compared to supine position. It can then be assumed that prone position would bring about greater improvement in oxygenation when PEEP applied in supine position is just beneath COP than when PEEP is above COP. Hemodynamically, prone position is expected to attenuate the lifting of cardiac fossa induced by PEEP. Based on these backgrounds, we investigated whether the effect of prone position on oxygenation differs in magnitude according to the level of PEEP applied in supine position, and whether impaired cardiac output in supine position by PEEP can be restored in prone position. Methods: In seven mongrel dogs, $PaO_2/F_1O_2$(P/F) was measured in supine position and at prone position 30 min. Cardiac output (CO), stroke volume (SV), pulse rate (PR), and pulmonary artery occlusion pressure (PAOP) were measured in supine position, at prone position 5 min, and at prone position 30 min. After ARDS was established with warmed saline lavage(P/F ratio $134{\pm}72$ mm Hg), inflection point was measured by constant flow method($6.6{\pm}1.4cm$ $H_2O$), and the above variables were measured in supine and prone positions under the application of Low PEEP($5.0{\pm}1.2cm$ $H_2O$), and Optimal PEEP($9.0{\pm}1.2cm$ $H_2O$)(2 cm $H_2O$ below and above the inflection point, respectively) consecutively. Results : P/F ratio in supine position was $195{\pm}112$ mm Hg at Low PEEP and $466{\pm}63$ mm Hg at Optimal PEEP(p=0.003). Net increase of P/F ratio at prone position 30 min, however, was far greater at Low PEEP($205{\pm}90$ mm Hg) than at Optimal PEEP($33{\pm}33$ mm Hg)(p=0.009). Compared to CO in supine position at Optimal PEEP($2.4{\pm}0.5$ L/min), CO in prone improved to $3.4{\pm}0.6$ L/min at prone position 5 min (p=0.0180) and $3.6{\pm}0.7$ L/min at prone position 30 min (p=0.0180). Improvement in CO was attributable to the increase in SV: $14{\pm}2$ ml in supine position, $20{\pm}2$ ml at prone position 5 min (p=0.0180), and $21{\pm}2$ ml at prone position 30 min (p=0.0180), but not to change in PR or PAOP. When the dogs were turned to supine position again, MAP ($92{\pm}23$ mm Hg, p=0.009), CO ($2.4{\pm}0.5$ L/min, p=0.0277) and SV ($14{\pm}1$ ml, p=0.0277) were all decreased compared to prone position 30 min. Conclusion: Prone position in a dog with saline-lavaged acute lung injury appeared to augment the effect of relatively low PEEP on oxygenation, and also attenuate the adverse hemodynamic effect of relatively high PEEP. These findings suggest that a PEEP lower than Optimal PEEP can be adopted in prone position to achieve the goal of alveolar recruitment in ARDS avoiding the hemodynamic complications of a higher PEEP at the same time.

  • PDF

Analysis of Position Error Variance on GNSS Augmentation System due to Non-Common Measurement Error (비공통오차 증가로 인한 위성항법보강시스템 위치 오차 분산 변화 분석)

  • Jun, Hyang-Sig;Ahn, Jong-Sun;Yeom, Chan-Hong;Lee, Young-Jae;Choi, Young-Kiu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.197-200
    • /
    • 2008
  • A GNSS augmentation system provides precise position information using corrected GNSS pseudorange measurements. Common bias errors are corrected by PRC (Pseudorange Correction) between reference stations and a rover. However non-common errors (Ionospheric and Tropospheric noise error) are not corrected. Using position error variance this paper analyzes non-common errors (noise errors) of ionosphere and troposphere wet vapor.

  • PDF

A Study on the Pressure Drops of T-Branch Pipes (분기배관의 압력강하에 관한 연구)

  • Nam, Jun-Seok;Baek, Chang-Sun;Kwon, Soon-Kwan;Kim, Dong-Hyun;Min, Kyung-Tak;Kim, Byoung-Gon;Lee, Sung-Ho
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.272-277
    • /
    • 2008
  • This study is performed for propose that exactly equivalent length of TBP in the applied at water-based fire protection system. For predict the measuring position of equivalent length, we determined the measuring position using the FVM about pressure drop of TBP. For the reckon of the exact about measured value we compared with the result of FVM and we knew the similar value each other. Using the results we proposed the friction loss measuring position that inlet of main dirction is 20 times of appellation diameter in main pipe, outlet of main dirction is 10 times of appellation diameter in main pipe and outlet of branched direction is 20 times of appellation diameter.

Development of 1-axis Exciter for a Seat Vibration Test of Agricultural Tractors(I) - Design of PID Controller for Position Control of 1-axis Exciter - (농용트랙터용 운전자 좌석 진동 시험을 위한 1축 가진 시험기 개발(I) - 1축 가진 시험기 위치 제어를 위한 PID 제어기 설계 -)

  • Yu, Ji-Hoon;Choi, Young-Kyun;Lee, Kyu-Cheol;Kim, Young-Joo;Ryu, Young-Sun;Ryuh, Kwan-Hee
    • Journal of Biosystems Engineering
    • /
    • v.34 no.5
    • /
    • pp.305-314
    • /
    • 2009
  • The purpose of this paper was to design an effective control system of 1-axis exciter for a seat vibration test of agricultural tractors using MATLAB simulation. The developed simulation model was composed with a hydraulic pump, a hydraulic servo valve, a hydraulic cylinder and load system. Also it was verified by comparing the simulation results with experimental results of actual control system in order to optimize the control performance. And in order to improve its control performance, the designed PID controller in this research was tuned using Ziegler-Nichols 2nd law and zero's moving method of PID controller's transfer function. As the result of these research, the developed position control system was able to control the system's position accurately within 5% errors.