• 제목/요약/키워드: subway induced vibration

검색결과 38건 처리시간 0.018초

지하철 진동이 구조물에 미치는 영향분석 모델 (MODEL FOR SUBWAY-INDUCED STRUCTURAL VIBRATION)

  • 김희철;이동근;민경원
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1993년도 가을 학술발표회논문집
    • /
    • pp.199-204
    • /
    • 1993
  • Noise and vibration induced by subway operation are one of the major factor that annoying residents living near the. railway. In general, lateral vibration was the major concern when we are considering vibration of the building. Since the energy due to earthquake is enormous it affects wide area. However, the vertical vibration became a major concern in considering the vibration induced by subway because relatively smaller energy affects only nearby areas than that of earthquake. Analysis model of the structure for the vertical vibration should consider the effect of beam vibration. Thus, the model of the structure for the lateral vibration can not be applied. Appropriate analysis model which can consider the inertia force of the beam is necessary when analyzing a structure for the vertical vibration. Modeling technique for the vertical vibration analysis of structures has been studied on this paper. It is recommeneded to use 2 or more elements for columns and to use 3 or more elements for beams when analyzing structures for vertical vibration induced by subway.

  • PDF

Serviceability assessment of subway induced vibration of a frame structure using FEM

  • Ling, Yuhong;Gu, Jingxin;Yang, T.Y.;Liu, Rui;Huang, Yeming
    • Structural Engineering and Mechanics
    • /
    • 제71권2호
    • /
    • pp.131-138
    • /
    • 2019
  • It is necessary to predict subway induced vibration if a new subway is to be built. To obtain the vibration response reliably, a three-dimensional (3D) FEM model, consisting of the tunnel, the soil, the subway load and the building above, is established in MIDAS GTS NX. For this study, it is a six-story frame structure built above line 3 of Guangzhou metro. The entire modeling process is described in detail, including the simplification of the carriage load and the determination of model parameters. Vibration measurements have been performed on the site of the building and the model is verified with the collected data. The predicted and measured vibration response are used together to assess vibration level due to the subway traffic in the building. The No.1 building can meet work and residence comfort requirement. This study demonstrates the applicability of the numerical train-tunnel-soil-structure model for the serviceability assessment of subway induced vibration and aims to provide practical references for engineering applications.

지하철 운행에 의한 중량터널의 진동 (Vibration of Massive Tunnel Structure Induced by Subway Operation)

  • 김희철;신효근
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.114-121
    • /
    • 1995
  • Problems of noise and vibration induced by subway operation became one of the major factor when new subway 1 me is under consideration. One of the most economic method in reducing the noise and vibration is the increasement of the tunnel mass. . Vibration of the massive tunnel structure has been measured induced by subway operation. STEDEF system which was adopted by Seoul Metropolitan Subway Bureau has been proved that more than 99% of the vibration has been decreased at the bottom of the railway track. Most of the vibration measured inside and outside of the tunnel showed that their peak frequency is around SOHz or 100Hz. The propagation characteristics of vibration in massive tunnel , wave propagate in three directions. Overall frequency in the range of 0 to 125H2 horizontal transmission usually increase, while vertical transmission decreases about 50% in the range of 0 to 25Hz and 90Hz to 125Hz regardless of modal shape.

  • PDF

지하철 진동에 의한 건축구조물의 진동특성 (Dynamic Response of Building Structures Induced by Subway Operation)

  • 김희철;이동근;민경원
    • 전산구조공학
    • /
    • 제8권1호
    • /
    • pp.95-106
    • /
    • 1995
  • 지하철의 운행에 의한 소음과 진동은 운행로 주위의 주민을 괴롭히는 중요한 요소의 하나이다. 일반적인 건물의 진동은 횡방향의 진동을 많이 고려하고 있으나 지하철의 운행에 의한 건물의 진동은 수직방향의 진동을 주요하게 다루어야 한다. 수직방향의 진동을 고려하기 위한 구조물은 보의 진동이 고려된 모델이어야 한다. 따라서 구조물의 수평방향 진동을 고려하기 위하여 사용된 모델은 수직방향의 진동을 고려하기 위한 모델과 같이 사용될 수 없다. 건물의 수직진동을 고려한 해석을 수행하기 위해서는 보의 관성력을 충분히 고려할 수 있는 모델이 사용되어야 한다. 본 논문에서는 지하철의 운행에 의한 구조물의 수직방향진동을 고려하기 위한 구조물의 해석 모델기법에 대하여 연구한 결과 기둥의 경우 하나이상 보의 경우 두개 이상의 요소로 나누어 해석하는 것이 바람직한 것으로 나타났다.

  • PDF

도시철도 지반진동 예측식 개선에 관한 연구 (Study on the Improvement of Empirical Formula for Prediction of Ground Vibration Induced by Urban Rapid Transit)

  • 신한철;조선규;양신추
    • 한국철도학회논문집
    • /
    • 제12권3호
    • /
    • pp.357-363
    • /
    • 2009
  • 본 논문에서는 도시철도 운행으로 발생하는 지반진동의 예측을 위하여 서울지하철 현장 계측을 실시하였다. 현장 계측 결과와 뉴욕지하철의 예측식과 동경지하철의 예측식으로 산정된 값과 비교한 결과, 국내 지반의 지반진동레벨은 뉴욕지하철의 예측식보다 크게 산정되었으며, 동경지하철의 예측식보다는 다소 작게 산정되었다. 또한, 계측현장 지반의 전파경로에 따라 토사지반과 암반지반으로 구분하여 국내 지반특성에 적합한 지반진동 예측식을 제안하였다.

지하철 운행에 따른 진동특성에 관한 연구 (A Study on the Characteristics of Vibration Induced by Subway Operation)

  • 배동명;신창혁;최철은;박상곤;백용진
    • 소음진동
    • /
    • 제11권2호
    • /
    • pp.249-256
    • /
    • 2001
  • In this paper the characteristics of vibration induced by subway trains running on track is discussed. The quantitative prediction of the vibration level and the countermeasure for reduction of necessary, is of importance for the better environment. It was made the constructed Bundang line as first step with the modified Young-Dan type to basis on the Japanese Young-Dan type. In this paper it was measured and analyzed to two region ($ \circled1$Susuh-Bokjung. $ \circled2$Chorim-Suhyun region) of this. at present, operational Bundang line when averaging velocity of train is 60 (km/h). As the response characteristics of frequency Induced by subway operation, it was confirmed that frequency band of neighborhood of 30~80 Hz in generally dominant. Also to assess the quantitative nitration as response level to be measured for each point of two region in subway operation, the vibrational response level was measured at the state to be not subway operation. And the level was approximately $\fraction one-fifth~\fraction one-ten$ level comparing to subway operation.

  • PDF

지하철 운행에 의한 인접건물의 진동영향 평가 연구 (Reduction and Evaluation of Subway Induced Vibration Effects on Surrounding Buildings)

  • 박지훈;민경원;이루지;최석주;염성곤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.738-742
    • /
    • 2005
  • Ground vibration at Gil-dong in Seoul induced by the 5th ling of Seoul Subway is predicted using various prediction methods and compared with measured vibration. Also, several issues on the improvement of prediction methods are discussed. Furthermore, as an alternative vibration source, measured vibration acceleration level(VAL) on the tunnel wall of the Bundang line of Seoul Subway is applied to the prediction of the VAL at the location mentioned previously. Then requirements accompanied to the suggestion of the new vibration source appropriate to the condition of Seoul Subway.

  • PDF

지하철에 의한 지반 진동 예측에 관한 연구 (Study for the prediction of ground-borne vibration induced by subway)

  • 이재원;김득성;장서일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1287-1292
    • /
    • 2001
  • Subway train-induced ground-borne vibration is studied. Previously used vibration level prediction equations are reviewed. Measured vibration levels are compared with the predicted results and numerically computed results. The results show that vibration level does not decrease proportionally with the distance.

  • PDF

지하철 운행에 따른 진동특성에 관한 연구 (A Study on the characteristics of vibration induced by Subway operation)

  • 배동명;신창혁;이창훈;박상곤
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2000년도 봄 학술발표회논문집
    • /
    • pp.332-339
    • /
    • 2000
  • In this paper the characteristics of vibration induced by subway trains running on track is discussed. The quantitative prediction of the vibration level and the countermeasure for reduction of necessary, is of importance for the better environment. It was made the constructed Bundang line as first step with the modified Young-Dan type to basis on the Japanese Young-Dan type. In this paper it was measured and analyzed to two region (①Susuh-Bokjung, ②Chorim-Suhyun region) of this, at present operational Bundang line when averaging velocity of train is 60(㎞/h). As the response characteristics of frequency induced by subway operation, it was confirmed that frequency band of neighborhood of 30∼80Hz in generally dominant. Also to assess the quantitative vibration as response level to be measured for each point of two region in subway operation, the vibrational response level was measured at the state to be not subway operation. And the level was approximately 1/5∼1/10 level comparing to subway operation.

  • PDF

Vertical Z-vibration prediction model of ground building induced by subway operation

  • Zhou, Binghua;Xue, Yiguo;Zhang, Jun;Zhang, Dunfu;Huang, Jian;Qiu, Daohong;Yang, Lin;Zhang, Kai;Cui, Jiuhua
    • Geomechanics and Engineering
    • /
    • 제30권3호
    • /
    • pp.273-280
    • /
    • 2022
  • A certain amount of random vibration excitation to subway track is caused by subway operation. This excitation is transmitted through track foundation, tunnel, soil medium, and ground building to the ground and ground structure, causing vibration. The vibration affects ground building. In this study, the results of ANSYS numerical simulation was used to establish back-propagation (BP) neural network model. Moreover, a back-propagation neural network model consisting of five input neurons, one hidden layer, 11 hidden-layer neurons, and three output neurons was used to analyze and calculate the vertical Z-vibration level of New Capital's ground buildings of Qingdao Metro phase I Project (Line M3). The Z-vibration level under different working conditions was calculated from monolithic roadbed, steel-spring floating slab roadbed, and rubber-pad floating slab roadbed under the working condition of center point of 0-100 m. The steel-spring floating slab roadbed was used in the New Capital area to monitor the subway operation vibration in this area. Comparing the monitoring and prediction results, it was found that the prediction results have a good linear relationship with lower error. The research results have good reference and guiding significance for predicting vibration caused by subway operation.