• 제목/요약/키워드: subjective ultrasonography

검색결과 16건 처리시간 0.025초

수지요법이 수면장애를 가진 성인의 수면의 질에 미치는 효과 - 수면다원검사 및 뇌혈류 검사를 통한 검증 - (Effects of Hand Acupuncture Therapy on Sleep Quality in Sleep Disrupted Adults - Verification by Polysomnography and Cerebral Blood Flow Test -)

  • 황은희
    • 대한간호학회지
    • /
    • 제37권7호
    • /
    • pp.1108-1118
    • /
    • 2007
  • Purpose: The purpose of this study was to identify the effects of hand acupuncture therapy on sleep quality by means of a sleep questionnaire, polysomnography and a cerebral blood flow test in $30{\sim}59$ year old adults. Methods: The study was a sham controlled design. Twenty-two adults were assigned to the pellet stimulating group (11) or sham group (11). The pellet stimulating group received hand acupuncture therapy using New Seoam Press Pellets number 1 for 4 weeks. On the other hand, the sham group used the same Adhesive tape in terms of shape, size and quality as New Seoam Press Pellets number 1 for 4 weeks. A Transcranial Doppler Ultrasonography and Carotid Duplex Ultrasonography examination were used for evaluating cerebral blood flow. Data was analyzed using the SPSS 12.0 version program with $X^2-test$, Fisher's exact test and Mann Whitney U-test. Results: In the pellet stimulating group, subjective sleep quality significantly improved more than that of the sham group. Among the sleep indices of the polysomnography, total sleep time and sleep latency of the sham group significantly improved. The cerebral blood flow test didn't show any differences. Conclusion: These results suggest that hand acupuncture therapy is effective for subjective sleep improvement only, not polysomnographical sleep indices and cerebral blood flow.

건강검진에서 지방간 진단의 상복부초음파검사와 간 Hounsfield Units 측정값과의 정확성 분석 (Fatty Liver Diagnostics from Medical Examination to Analyze the Accuracy Between the Abdominal Ultrasonography and Liver Hounsfield Units)

  • 오왕균;김상현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권2호
    • /
    • pp.229-235
    • /
    • 2017
  • 상복부초음파검사에서 간실질의 에코 음영증가와 불명확한 혈관경계 등으로 지방간을 진단하는데, 여러 연구들에 의하면 지방간 진단에 84~95%의 특이도와 60~90%의 민감도를 가지나 결과가 검사자에 의존적이어서 차이가 있을 수 있고 지방의 침윤 상태의 정량적인 측정이 불가능하다. 건강검진의 상복부초음파검사와 흉부 전산화단층촬영(computed tomography; CT) 검사를 같은 날에 시행한 수검자중 초음파검사에서 지방간을 진단 받은 환자의 흉부 전산화단층촬영 영상에서 간(Liver) Hounsfield Units(HU)를 측정하여 지방간 진단의 정확성을 연관분석 하고자 하였다. 연구대상 수검자 720명 중 가정의학과 전문의에게 검사를 받고 지방간 판정을 받은 자는 448명으로 62.2%였다. 지방간 판정자의 CT영상에서 간 HU를 측정한 결과 40 HU 이하의 측정값은 720명 중 175명으로 24.3%이며, 초음파에서 진단 받은 448명에 175명 중 173명이 포함되어 98.9%가 일치하였다. 이는 지방간을 초음파로 진단 시 검사자의 주관적 경험과 능력이 병변을 진단하는데 크게 영향을 미친 것으로 생각되며 검진 CT검사에서 간 HU를 측정하여 40 HU 이하는 영상저장을 통하여 지방간 진단 시 참고자료로 활용될 수 있을 것으로 사료된다.

초음파 영상 깃각 자동 측정 프로그램 개발 (Development of an Automatic Measuring Program for the Pennation Angle Using Ultrasonography Image)

  • 김종순
    • 대한통합의학회지
    • /
    • 제5권1호
    • /
    • pp.75-83
    • /
    • 2017
  • Purpose : The parameters used in architectural analysis are muscle thickness, fascicle length, pennation angle, etc. Pennation angle is an important muscle characteristic that plays a significant role in determining a fascicle's force contribution to movement. Ultrasonography has been widely used to obtain the image for measurement of a pennation angle since it is non-invasive and real-time. However, manual assessment in ultrasonographic images is time-consuming and subjective, making it difficult for using in muscle function analysis. Thus, in this study, I proposed an automatic method to extract the pennation angle from the ultrasonographic images of gastrocnemius muscle. Method : The ultrasonographic image obtained from 10 healthy participants's gastrocnemius muscle using for developed automatic measuring program. Automatic measuring program algorithm consists with preprocessing, line detection, line classification, and angle calculation. The resulting image was then used to detect the fascicles and aponeuroses for calculating the pennation angle with the consideration of their distribution in ultrasonographic image. Result : The proposed automatic measurement program showed the stable repeatability of pennation angle calculation. Conclusion : This study demonstrated that the proposed method was able to automatically measure the pennation angle of gastrocnemius, which made it possible to easily and reliably investigate pennation angle more.

Effect of Sharbat Afsantīn in Poly Cystic Ovarian Disease - An Open Observational Study

  • Zubair, Zainab;Shameem, Ismath;Begum, Wajeeha
    • 셀메드
    • /
    • 제12권3호
    • /
    • pp.10.1-10.12
    • /
    • 2022
  • Objective: The objective of the study was to evaluate the effect of Sharbat Afsantin in Polycystic Ovarian Disease. Methods: An open observational study was carried out in the Department of Ilmul Qabalat wa Amraze Niswan. Diagnosed cases(n=30) of PCOD were included in the study. Patients with thyroid dysfunction, systemic diseases, on hormonal treatment in last three months, pregnancy and lactation were excluded. Research drug (Sharbat Afsantin) was administered orally in a dose of 25ml twice daily for 15 days/cycle for three consecutive cycles. Outcome measures were, changes in subjective parameters (duration of cycle, duration and amount of flow and weight reduction) and objective parameters {pictorial blood loss assessment chart (PBAC) score, basal metabolic index (BMI), modified Ferriman Gallwey (mFG) score, acanthosis nigricans scale and pelvic ultrasonography}. Data were analyzed using paired Student 't' test. Results: Changes in duration of cycle, duration and amount of flow were achieved in 83.3%, 50% and 40% patients respectively and weight reduction in 30% patients. Changes in PBAC score and BMI were achieved in 50% and 30% patients respectively and 30% patients showed normal findings on pelvic ultrasonography. Conclusion: Sharbat Afsantin can be used as an alternate remedy in PCOD patients, as it has significant effect to regularize menstruation by reduction in BMI and probably by improving insulin resistance in PCOD. No adverse effect of Sharbat Afsantin was noted during the trial.

개에서 겐타마이신으로 유발된 급성 신부전의 초음파상 변화 (Ultrasonographic Changes of Acute Renal Failure Induced by Gentamicin in Dogs)

  • 진경훈;정종태
    • 한국임상수의학회지
    • /
    • 제18권1호
    • /
    • pp.35-43
    • /
    • 2001
  • Present study was undertaken in order to document early renal ultrasonographic changes of gentamicin nephrotoxicosis and to show the value of renal ultrasonography as a contributory means of early diagnosis of acute renal failure in dogs. The experimental design was a randomized complete block design with six treatments in two blocks (gentamicin-treated & saline-treated). Acute renal failure was induced by toxic dosage of gentamicin (30 mg/kg) and saline solution sham equivalent in volume to that of the toxic dosage of gentamicin (1.5-3ml). Subjective visualization of increased renal cortex was visible as homogenous echoes that were hypoechoic relative to the surrounding tissues, whereas the renal medulla was anechoic to slightly hypoechoic. After treatment, the renal cortex was hyperechoic relative to the surrounding tissue. Increased renal cortex echogenicity was associated with significant nephrotoxicosis and was superior to serum creatinine elevation in nephrotoxicosis detection. Urine GGT was superior to other clinicopathological data utilized in the diagnosis of nephrotoxicosis. Based on the above results, increased renal cortex echogenicity seemed to be of use in detecting of acute renal failure.

  • PDF

Comparison of Effectiveness in Differentiating Benign from Malignant Ovarian Masses between IOTA Simple Rules and Subjective Sonographic Assessment

  • Tongsong, Theera;Tinnangwattana, Dangcheewan;Vichak-ururote, Linlada;Tontivuthikul, Paponrad;Charoenratana, Cholaros;Lerthiranwong, Thitikarn
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권9호
    • /
    • pp.4377-4380
    • /
    • 2016
  • Background: To compare diagnostic performance in differentiating benign from malignant ovarian masses between IOTA (the International Ovarian Tumor Analysis) simple rules and subjective sonographic assessment. Materials and Methods: Women scheduled for elective surgery because of ovarian masses were recruited into the study and underwent ultrasound examination within 24 hours of surgery to apply the IOTA simple rules by general gynecologists and to record video clips for subjective assessment by an experienced sonographer. The diagnostic performance of the IOTA rules and subjective assessment for differentiation between benign and malignant masses was compared. The gold standard diagnosis was pathological or operative findings. Results: A total of 150 ovarian masses were covered, comprising 105 (70%) benign and 45 (30%) malignant. Of them, the IOTA simple rules could be applied in 119 (79.3%) and were inconclusive in 31 (20.7%) whereas subjective assessment could be applied in all cases (100%). The sensitivity and the specificity of the IOTA simple rules and subjective assessment were not significantly different, 82.9% vs 86.7% and 94.0% vs 94.3% respectively. The agreement of the two methods in prediction was high with a Kappa index of 0.835. Conclusions: Both techniques had a high diagnostic performance in differentiation between benign and malignant ovarian masses but the IOTA rules had a relatively high rate of inconclusive results. The IOTA rules can be used as an effective screening technique by general gynecologists but when the results are inconclusive they should consult experienced sonographers.

굴절이상을 결정하는 안광학 요소에 관한 연구 (Study of Ocular Components in Determining the Refractive State of the Eye)

  • 서용원;최영준
    • 한국안광학회지
    • /
    • 제4권1호
    • /
    • pp.7-14
    • /
    • 1999
  • 본 논문에서는 한국인 17세에서 30세사이의 38명을 대상으로 Vision Tester로 자각적 굴절이상을 측정하고, 난시가 있는 사람은 등가구면도수틀 취했다. 각막 굴절력과 곡율반경은 Baush & Lomb사 Keratometer로 측정했으며 전방의 깊이, 수정체의 두께, 초자체의 깊이, 안축의 길이 등은 A-mode Ultrasonography로 측정 했고, 각막 두께는 Phakometry로 측정했다. 굴절이상과 안광학요소의 상관계수를 구한 결과 안축의 길이, 초자체의 깊이, AL/CR 비와는 각각 0.95, 0.96, 0.95로 아주 높은 상관관계가 있었고, 각막곡율반경, 굴절력, 수정체의 두께와는 각각 0.60, 0.66, 0.67로 나타났으며, 각막의 두께와는 괄목할 만한 상관관계가 없었다.

  • PDF

내시경 초음파 영상의 점막하 종양 분석 (Submucosal Tumor Analysis of Endoscopic Ultrasonography Images)

  • 김광백
    • 한국멀티미디어학회논문지
    • /
    • 제13권7호
    • /
    • pp.1044-1050
    • /
    • 2010
  • 내시경 초음파는 초음파 진동자를 내시경 끝에 부착하여 그 주위의 장기를 관찰할 목적으로 개발된 의료기기이다. 내시경 초음파 검사는 점막하 종양을 직접 관찰 할 수 있어 종양의 병리 소견이 예측 가능하지만, 종양의 악성화 여부 등에 대해 주관적인 소견이 개입될 수 있는 문제점이 있다. 따라서 본 논문에서는 주관적인 소견으로 인해 나타나는 문제점을 객관화하여 질병의 정확도와 재현성을 높이기 위해 종양의 각 특징을 분석하는 방법을 제안한다. 제안된 방법을 적용하기 위해서 내시경 초음파 검사로 얻어진 초기 영상에서 분석에 필요한 초음파 영역을 추출한다. 초음파 영역은 여러 요인으로 인하여 명암도 값의 차이가 발생하는데, 이는 객관적인 분석에는 비효율적이다. 따라서 초기 검사 시에 매질로써 주입되는 물 영역의 명암도를 기준으로 하여 초음파 영역의 명암도를 표준화 한다. 표준화된 초음파 영역에서 전문의에 의하여 선택된 종양 영역에 LVQ 알고리즘과 비트 평면 분할 방법을 각각 적용하여 에코가 높은 spot 영역과 칼슘이 침착된 영역을 추출하고 분석한다. 종양 영역의 세밀한 분석을 위하여 명암도 값과, 종양 영역 내에서 전문의가 임의로 선택한 두 지점의 거리에 포함된 명암도 정보를 추출한다. 또한 선택된 종양의 악성도를 구분하기 위하여 종양 영역에서 외곽의 기울기를 계산한다. 내시경 초음파 영상에서 각 질병의 특징을 분석한 결과, 제시된 방법이 종양이 가지는 특징을 분석하는데 도움이 되는 것을 확인할 수 있었다.

Varicose Veins and the Diagnosis of Chronic Venous Disease in the Lower Extremities

  • Jae Ho Chung;Seonyeong Heo
    • Journal of Chest Surgery
    • /
    • 제57권2호
    • /
    • pp.109-119
    • /
    • 2024
  • Varicose veins usually present in the superficial veins of the lower extremities and are one of the main clinical presentations of chronic venous disease (CVD). Patients' symptoms may vary according to the pathophysiology, location, and severity of CVD. The prevalence of CVD in Korea has been increasing gradually. However, due to its broad clinical spectrum and the subjective nature of its diagnosis using ultrasound, discrepancies in diagnostic and treatment quality may exist among treating physicians. There have been recent efforts to improve the quality of the diagnosis and treatment of varicose veins in Korea by standardizing the diagnostic criteria and the indications for treatment. This study is a comprehensive review of the clinical manifestations and diagnostic criteria of CVD based on the most recent international and domestic guidelines and reports.

내시경 초음파 영상의 특징 분석 (Feature Analysis of Endoscopic Ultrasonography Images)

  • 김광백;강효주;김미정;김광하
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2009년도 춘계 종합학술대회 논문집
    • /
    • pp.390-397
    • /
    • 2009
  • 내시경 초음파는 초음파 진동자를 내시경 끝에 부착하여 그 주위의 장기를 관찰할 목적으로 개발된 의료기기이다. 내시경 초음파 검사는 점막하 종양을 직접 관찰 할 수 있어 종양의 병리 소견이 예측 가능하지만, 종양의 악성화 여부 등에 대해 주관적인 소견이 개입될 수 있는 문제점이 있다. 따라서 본 논문에서는 주관적인 소견으로 인해 나타나는 문제점을 객관화하여 질병의 정확도와 재현성을 높이기 위해 종양의 각 특징을 분석하는 방법을 제안한다. 제안된 방법을 적용하기 위해서 내시경 초음파 검사로 얻어진 초기 영상에서 분석에 필요한 초음파 영역을 추출한다. 초음파 영역은 여러 요인으로 인하여 명암도 값의 차이가 발생하는데, 이는 객관적인 분석에는 비효율적이다. 따라서 초기 검사 시에 매질로써 주입되는 물의 영역의 명암도를 기준으로 하여 초음파 영역의 명암도를 표준화 한다. 표준화 된 초음파 영역에서 전문의에 의하여 선택된 종양 영역에 LVQ 알고리즘과 비트 평면 분할 방법을 각각 적용하여 에코가 높은 spot 영역과 칼슘이 침착된 영역을 추출하고 분석한다. 종양 영역의 세밀한 분석을 위하여 명암도 값과, 종양 영역 내에서 전문의가 임의로 선택한 두 지점의 거리에 포함된 명암도 정보를 추출한다. 또한 선택된 종양의 악성도를 구분하기 위하여 종양 영역에서 외곽의 기울기를 계산한다. 내시경 초음파 영상에서 각 질병의 특징을 분석한 결과, 제시된 방법이 종양이 가지는 특징을 분석하는데 도움이 되는 것을 확인할 수 있었다.

  • PDF