• 제목/요약/키워드: subcooling system

검색결과 91건 처리시간 0.024초

자동차용 평행류 응축기의 열성능 모델링 (Thermodynamic Modeling of Parallel Flow Condenser for Automotive Air Conditioning System)

  • 김일겸;고재윤;박상록;임장순
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.771-779
    • /
    • 2001
  • In this study, a simulation program has been developed to predict the performance of a parallel flow condenser of an air conditioning system for an automobile. The well-known correlations for he heat transfer rates and the pressure drops are included in this model. It is fond that the numerical model can predict the heat transfer rate and the pressure drop accurately. As the condensing pressure increases of fixed air inlet temperature, the heat transfer rate increases and the pressure drop decreases. The effect of he degree of subcooling on the performance of the condenser is greater than that of the degree of super-heating because the ratio of the area occupied by he tow-phase refrigerant the total area is significantly affected by he degree of subcooling rather than the degree of superheating.

  • PDF

항공기 외장형 정찰 장비용 냉각 시스템의 성능 특성에 관한 실험적 연구 (An Experimental Study on the Performance Characteristics of Cooling System for Aircraft External Reconnaissance Stores)

  • 정대윤;이행복
    • 한국군사과학기술학회지
    • /
    • 제16권1호
    • /
    • pp.74-80
    • /
    • 2013
  • In this paper, we have proposed a vapor cycle refrigeration system as a cooling system to provide cooling air to the aircraft external reconnaissance stores. In the proposed vapor cycle system, receiver which prevents refrigerant from subcooling was eliminated and thermal expansion valve was replaced with electronic expansion valve. The vapor cycle refrigeration system is aimed to provide cooling air to the reconnaissance stores which is added to the aircraft in the form of external store. The wide temperature range of ambient air from the flight conditions can decrease the cooling performance and can make the refrigeration system unstable in low ambient temperature. Performance characteristics of the vapor cycle refrigeration system has been experimented under air conditions which is derived from the flight envelope. From the experiments, the vapor cycle refrigeration system has been proved to provide enough cooling air to the reconnaissance equipment and to be stable under all the flight conditions.

R410A용 2단 압축 1단 팽창 냉동시스템의 성능 분석 (Performance Comparison of Two-stage Compression Refrigeration System Using R404A)

  • 윤정인;최광환;손창효;조환
    • 동력기계공학회지
    • /
    • 제18권1호
    • /
    • pp.57-62
    • /
    • 2014
  • This paper present the performance characteristics of R404A two-stage compression refrigeration system. The operating parameters considered in this study include evaporating and condensing temperature, subcooling and superheating degree, compressor efficiency. The main results were summarized as follows: The COP of two-stage compression refrigeration system using R404A has an effect on the variation of evaporation temperature, condensation temperature, subcooling degree and compressor efficiency, but not an effect on the superheating degree. R404A two-stage compression refrigeration system is unstable because COP of this system is significantly changed when evaporating temperature and compressor efficiency decreased. In particular, when compressor efficiency decreased, COP is significantly decreased. This is inefficient for long-term use.

2단 증기 압축식 냉동시스템을 적용한 해상용 제빙장치의 냉매에 따른 성능 분석 (Performance Analysis of a Seawater Ice Machine Applied Two-stage vapor compression refrigeration system for Various Refrigerants)

  • 윤정인;손창효;허성관;전민주;전태영
    • 동력기계공학회지
    • /
    • 제20권2호
    • /
    • pp.85-90
    • /
    • 2016
  • Coefficient of performance (COP) for two-stage compression system is investigated in this paper to develop seawater ice machine. The system performance is analyzed with respect to degrees of superheating and subcooling, condensing and evaporating temperatures, compression and mechanical efficiencies and mass flow ratio in an inter-cooler. The main results are summarized as follows : The COP of the system grows when the mass flow ratio, subcooling degree and evaporating temperature edge up. Contrariwise, the system performance descends in case that superheating degree and condensing temperature increase. The most effective factor for the COP is the mass flow rate ratio. Each refrigerant has different limitation for a value of the mass flow ratio in the inter-cooler because of difference in material property.

R744를 2차 냉매로 사용하는 내부열교환기 부착 R404A 냉동시스템의 성능 분석 (Performance Analysis of R404A Refrigeration System with Internal Heat Exchanger Using R744 as a Secondary Refrigerant)

  • 오후규;손창효;이문빈;전민주
    • 설비공학논문집
    • /
    • 제25권10호
    • /
    • pp.548-554
    • /
    • 2013
  • A thermodynamic analysis of the R404A refrigeration system with an internal heat exchanger using R744 as a secondary refrigerant is presented in this paper to optimize the design for operating parameters of the system. The main results are summarized as follows: The COP increases with increasing subcooling and superheating degree of R404A, internal heat exchanger and compression efficiency of the R404A cycle and evaporating temperature of the R744 cycle and decreasing temperature difference of the cascade heat exchanger and condensing temperature of the R404A cycle. The mass flow ratio decreases with increasing evaporating temperature of the R744 cycle and internal heat exchanger efficiency of the R404A cycle and decreasing subcooling and superheating degree of the R744 cycle, temperature difference of the cascade heat exchanger and condensing temperature of the R404A cycle.

Improvement of the critical heat flux correlation in a thermal-hydraulic system code for a downward-flow narrow rectangular channel

  • Wisudhaputra, Adnan;Yun, Byong Jo;Jeong, Jae Jun
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3962-3973
    • /
    • 2022
  • Several critical heat flux (CHF) correlations including the look-up table in the MARS code have been assessed for the prediction of CHF in a downward-flow narrow rectangular channel. For the assessment, we built an experiment database that covers pressures between 1.01 and 39.0 bar, gap sizes between 1.09 and 6.53 mm, mass fluxes up to 25,772 kg/m2s, and under one-sided and two-sided heating conditions. The results of the assessment showed that the Kaminaga correlation has the best overall prediction compared to others. However, because the correlation uses global variables, such as inlet and outlet subcooling and total heat transfer area, it is difficult to use in a system code. A new CHF correlation is then proposed by replacing the global variables in the Kaminaga correlation with local ones and adding correction factors to consider the effect of gap size, mass flux, and the number of heating walls. Additional correction factor is added to consider the effect of inlet subcooling. It is shown that the new one is better than the Kaminaga correlation and it is easy to implement to any system code.

지열을 이용한 코일 침적형 히트펌프의 성능 특성 (Performance characteristics of the Coil Deposition Type Heat Pump using Geothermal Energy)

  • 오후규;이동건;전민주;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권4호
    • /
    • pp.437-444
    • /
    • 2012
  • 본 논문은 지열을 이용한 코일 침적형 히트펌프 시스템의 운전변수에 대한 최적 설계를 위해서 히트펌프의 성능 특성을 실험적으로 조사하였다. 본 연구에서 고려된 작동변수로는 과냉각도, 증발온도, 응축온도 등이다. 그 실험결과를 요약하면 다음과 같다. 지열 이용 코일 침적형 히트펌프 시스템의 증발온도와 과냉각도가 증가할수록, 응축온도는 감소할수록 성능계수는 증가함을 알 수 있다. 즉, 지열 이용 코일 침적형 히트펌프 시스템의 증발온도, 응축온도, 과냉각도는 냉방과 난방의 성능계수에 영향을 미치는 것을 알 수 있다. 따라서 본 연구에서 제안하는 히트펌프 시스템이 최고의 성능을 나타내기 위한 최적의 운전조건을 결정할 필요가 있다.

대체냉매 R-407C의 모세관 선정에 관한 연구 (Investigation on the selection of capillary tube for the alternative refrigerant R-407C)

  • 김용환;김창년;박영무
    • 설비공학논문집
    • /
    • 제10권1호
    • /
    • pp.56-65
    • /
    • 1998
  • In this paper, experimental investigation of capillary tube performance for R-407C is performed. The experimental setup is made of real vapor-compression refrigerating system. In this study, mass flow rate is measured for capillary tubes of various diameter and length as inlet pressure and degree of subcooling are changed. These data are compared with the results of a numerical model. The mass flow rates of the numerical model are less than by 14% compared with the measured mass flow rates. It is found that mass flow rate and length for R-407c are less than those of R-22 under the same condition. Also based on this experimental study and the numerical model, a set of capillary tube selection charts for R-407C is constructed.

  • PDF

연직상향(鉛直上向) 사각충돌수분류(四角衝突水噴流)의 포화비등 열전달에 관한 연구 (A Study on Saturated Boiling Heat Transfer in Upward Rectangular Impinging Water Jet System)

  • 이종수;엄기찬;서정윤
    • 설비공학논문집
    • /
    • 제3권5호
    • /
    • pp.395-403
    • /
    • 1991
  • The purpose of this investigation was to characterize nucleate boiling and burn-out heat flux for rectangular free jet with saturated water impinging perpendicularly and upward against a flat uniform heat flux surface. Heat flux measured for Reynolds number based on rectangular nozzle width and for aspect ratio. The result of nucleate boiling heat transfer was presented nondimensional experimental equation including Nusselt, Boiling, Subcooling, Reynolds and Weber number. The effect of aspect ratio of heated surface in the burn-out heat flux had not appeared distinctly. But for the same aspect ratio, burn-out heat flux increased linearly with increment of nozzle exit velocity.

  • PDF

냉동시스템의 운전조건에 따른 열교환기 내장형 어큐뮬레이터의 성능 특성 (Performance Characteristics of Accumulator Heat Exchangers with Operating Conditions of a Refrigeration System)

  • 강훈;박차식;전종욱;김용찬
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.984-991
    • /
    • 2006
  • The applications of multi air-conditioners into multiplex and high-rise buildings have been increased by replacing central air-conditioning systems. The pipe length and altitude difference between the indoor and outdoor units can be increased based on installation conditions, which may increase the possibility of flash gas generation at the expansion device inlet. The flash gas generation causes rapid reduction of refrigerant flow rate passing through the expansion device, yielding lower system efficiency. Accumulator heat exchangers have been widely used in multi air-conditioners in order to minimize flash gas generation and obtain system reliability. However, the studies on the heat transfer characteristics and pressure drops of accumulator heat exchangers are very limited in open literature. In this study, the heat transfer rates and pressure drops of accumulator heat exchangers were measured with refrigerant flow rate and operating conditions by using R-22. The heat transfer rate increased with the increase of refrigerant flow rate, while subcooling decreased. The heat transfer rate enhanced with the reduction of inlet superheat and subcooling due to the increased temperature difference between the accumulator and inner heat exchanger.