• Title/Summary/Keyword: sub-cooled nitrogen

Search Result 42, Processing Time 0.022 seconds

HTS high gradient magnetic separator prototype

  • Diev, D.N.;Lepehin, V.M.;Makarenko, M.N.;Polyakov, A.V.;Shcherbakov, V.I.;Shutova, D.I.;Surin, M.I.;Tagunov, E. Ya.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.4
    • /
    • pp.1-5
    • /
    • 2018
  • A high gradient magnetic (HGM) separator prototype with the $2^{nd}$ generation high temperature superconducting (2G HTS) magnetic system operated in sub-cooled nitrogen is presently under development at NRC "Kurchatov Institute" (Moscow, Russia). The main goal of the project is an attempt to shift away from the complicated liquid helium cryostats towards simple cryocooler-based nitrogen cryogenics as much more convenient for HGM separators industrial applications. Using of commercial HTS tapes allows to get a sufficient level of magnetic fields and extraction forces with low energy consumption. The expected operational parameters of the device are 1.2-1.5 T in the empty operational gap and up to 3 T on the ferromagnetic filters. In this paper we briefly describe the design of the HTS rotary separator prototype with the horizontally oriented rotor axis and propose different types of ferromagnetic filters intended for weakly magnetic ores enrichment.

Fabrication of the HTS Solenoid for DG Reactor of 6.6kV/200A Inductive Superconducting Fault Current Limiter (6.6kV00A급 유도형 초전도한류기의 DC 리액터용 고온 초전도 솔레노이드의 제작)

  • 김현석;안민철;이승제;이안수;이상진;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.230-233
    • /
    • 2003
  • This paper deals with the fabrication of high temperature superconducting(HTS) solenoid for DC reactor of 6.6㎸/200A inductive superconducting fault current limiter(SFCL). The winding machine which is suitable to wind HTS wire was manufactured. The proper inductance was calculated by circuit simulation and G10-FRP bobbin was fabricated with this inductance, HTS solenoid was wound by using the winding machine. The V-I characteristic of completed DC reactor in sub-cooled nitrogen(65K) was measured. The full quench current of this magnet is about 490A.

  • PDF

Cooling performance test of the superconducting fault current limiter

  • Yeom, H.;Hong, Y.J.;In, S.;Ko, J.;Kim, H.B.;Park, S.J.;Kim, H.;Kim, H.R.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.4
    • /
    • pp.66-70
    • /
    • 2014
  • The superconducting fault current limiter (SFCL) is an electrical power system device that detects the fault current automatically and limits the magnitude of the current below a certain safety level. The SFCL module does not have any electrical resistance below the critical temperature, which facilitates lossless power transmission in the electric power system. Once given the fault current, however, the superconducting conductor exhibits extremely high electrical resistance, and the magnitude of the current is accordingly limited to a low value. Therefore, SFCL should be maintained at a temperature below the critical temperature, which justifies the cryogenic cooling system as a mandatory component. This report is a study which reported on the cooling system for the 154 kV-class hybrid SFCL owned by Korea Electric Power Corporation (KEPCO). Using the cryocooler, the temperature of liquid nitrogen (LN2) was lowered to 71 K. The cryostat was pressurized to 5 bars to improve the dielectric strength of nitrogen and suppress nitrogen bubble foaming during operation of SFCL. The SFCL module was immersed in the liquid nitrogen of the cryostat to maintain the superconducting state. The performance test results of the key components such as cryocooler, LN2 circulation pump, cold box, and pressure builder are shown in this paper.

Processing and Quality of a Retort Pouched Soup Made from Brown-backed Toadfish Lagocephalus gloveri (흑밀복(Lagocephalus gloveri)을 이용한 레토르트파우치 복국의 제조 및 품질특성)

  • Hwang, Seok-Min;Kim, Gun-Cheol;Hwang, Young-Sook;Jeon, Eun-Bi;Lee, Hyun-Jin;Oh, Kwang-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.53 no.3
    • /
    • pp.308-315
    • /
    • 2020
  • To obtain a value-added product from the non-toxic brown-backed toadfish Lagocephalus gloveri (pufferfish), we developed a retort pouched pufferfish soup (RPS) and characterized its processing conditions and quality metrics. We found that the most appropriate manufacturing process for the RPS consisted of detoxifying and cold-water dipping the pufferfish flesh, blanching it, and adding it to the retort pouch along with other ingredients (hot-water extract of pufferfish head and carcass, radish, bean sprouts, and garlic), after which the pouch was sealed, sterilized (120℃, F0 value 7.5-10 min.), cooled, and inspected. The moisture, crude protein, and total volatile basic nitrogen contents of the RPS were 97.2%, 1.3% and 7.7 mg/100 g, respectively. The total free amino acid content was 903.2 mg/100 g, and the main free amino acids were glutamic acid, taurine, lysine, glycine, threonine, alanine, arginine, proline, and hydroxyproline. Sterilizing the RPS for up to F0 value 10 min. did not cause any major problems in terms of chemical or sensory qualities. This RPS has good storage stability and organoleptic qualities compared with similar commercial pufferfish soups and is suitable for commercialization as a value-added instant seafood soup.

Fabrication of Porous Ti by Freeze-Drying and Heat Treatment of TiH2/Camphene Slurries (TiH2/camphene 슬러리의 동결건조 및 열처리에 의한 Ti 계 다공체의 제조)

  • Seo, Han Gil;Kim, Young Do;Suk, Myung-Jin;Oh, Sung-Tag
    • Korean Journal of Materials Research
    • /
    • v.23 no.6
    • /
    • pp.339-343
    • /
    • 2013
  • Porous Ti-systems with unidirectionally aligned channels were synthesized by freeze-drying and a heat treatment process. $TiH_2$ powder and camphene were used as the source materials of Ti and sublimable vehicles, respectively. Camphene slurries with $TiH_2$ content of 10 and 15 vol% were prepared by milling at $50^{\circ}C$ with a small amount of oligomeric polyester dispersant. Freezing of the slurry was done in a Teflon cylinder attached to a copper bottom plate cooled at $-25^{\circ}C$ while unidirectionally controlling the growth direction of the camphene. Pores were generated subsequently by sublimation of the camphene during drying in air for 48 h. The green body was heat-treated at $1100^{\circ}C$ for 1 h in a nitrogen and air atmosphere. XRD analysis revealed that the samples composed of TiN and $TiO_2$ phase were dependent on the heat-treatment atmosphere. The sintered samples showed large pores of about 120 mm which were aligned parallel to the camphene growth direction. The internal wall of the large pores had relatively small pores with a dendritic structure due to the growth of camphene dendrite depending on the degree of nucleation and powder rearrangement in the slurry. These results suggest that a porous body with an appropriate microstructure can be successfully fabricated by freeze-drying and a controlled sintering process of a camphene/$TiH_2$ slurry.

Development of Distribution Superconducting Fault Current Limiter and its Monitoring System for Power IT Application (배전급 초전도한류기 및 전력 IT 응용을 위한 실시간 모니터링 시스템 개발)

  • Park, Dong-Keun;Seok, Bok-Yeol;Ko, Tae-Kuk;Kang, Hyoung-Ku
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.398-402
    • /
    • 2008
  • Recently, the development of superconducting fault current limiters (SFCLs) has been required as power demands increase in the power system. A distribution-level prototype resistive SFCL using coated conductor (CC) has been developed by Hyundai Heavy Industries Co., Ltd. and Yonsei University for the first time in the world. The ratings of the SFCL are 13.2kV/630A at normal operating condition. A novel non-inductive winding method is used in fabricating coils so there is almost zero impedance during normal operation. The distribution SFCL is cooled by sub-cooled liquid nitrogen $(LN_2)$ of 65K and 3 bar to enhance cryo-dielectric performance, critical current density, and thermal conductivity. In order to make reliable operation of an SFCL in real power systems, we monitored and controled its operation conditions by using supervisory control and data acquisition (SCADA) method. Thus, a monitoring system for the SFCL employing information technology (IT) is proposed and developed to be on the lookout for the operation conditions such as inside temperature, inside pressure, $LN_2$ level, voltage and current. Since operation temperature should be kept constant, bang-bang control for temperature feedback with a heater attached to the cold head of cryo-cooler is applied to the system. Short-circuit tests with prospective fault current of 10kA and AC dielectric withstand voltage tests up to 143kV for 1 minute were successfully performed at Korea Electrotechnology Research Institute. This paper deals with the development of a distribution level SFCL and its monitoring system for reliable operation.

Fabrication and Characteristic Tests of a 1 MVA Single Phase HTS Transformer with Concentrically Arranged Windings

  • Kim, S.H.;Kim, W.S.;Choi, K.D.;Joo, H.G.;Hong, G.W.;Han, J.H.;Lee, H.G.;Park, J.H.;Song, H.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.4
    • /
    • pp.37-40
    • /
    • 2004
  • A 1 MV A single phase high temperature superconducting (HTS) transformer was manufactured and tested. The rated voltages of primary and secondary of the HTS transformer are 22.9 kV and 6.6 kV respectively. BSCCO-2223 HTS tape was used for HTS windings of 1 MV A HTS transformer. In order to reduce AC loss generated in the HTS winding, the type of concentric arrangement winding was adopted to a 1 MV A HTS transformer. Single HTS tape for primary windings and 4 parallel HTS tapes for secondary windings were used considering the each rated current of the HTS transformer. A core of HTS transformer was fabricated as a shell type core made of laminated silicon steel plate. And a GFRP cryostat with a room temperature bore was also manufactured. The characteristic tests of 1 MV A HTS transformer were performed such as no load test, short circuit test and several insulation tests at 65 K using sub-cooled liquid nitrogen. From the results of tests, the validity of design of HTS transformer was ascertained.

Analysis of Over-current Characteristics in YBCO Coated Conductor (YBCO Coated Conductor의 과전류 특성해석)

  • Lee, C.;Nam, K.;Kang, H.;Ko, T.K.;Seok, B.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.693-694
    • /
    • 2006
  • In order to develop a high temperature superconducting(HTS) coil for the fault current limiter(FCL), the over-current characteristics in YBCO coated conductor(CC) with Ni-W alloy substrate are analyzed. The HTS wire is wound by bifilar winding method for resistive current limitation and it is operated in 65K sub-cooled nitrogen. In order to analyze the resistance and the temperature characteristics of the CC wire, an analysis program is developed considering all the composition materials except the buffer layer. Using this program, the temperature rise, the resistance development and the current limitation of CC are calculated depending on the applied voltage and the stabilizer materials. According to the analysis results, under the temperature restriction of 300K, the maximum voltage per meter is determined as 40V/m if the stabilizer is $25{\mu}m$ thick stainless steel at each side. Finally, the wire length needed for the distribution level HTS FCL is estimated.

  • PDF

Investigation on Effective Operational Temperature of HTS Cable System considering Critical Current and AC loss

  • Kim, Tae-Min;Yim, Seong-Woo;Sohn, Song-Ho;Lim, Ji-Hyun;Han, Sang-Chul;Ryu, Kyung-Woo;Yang, Hyung-Suk
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.307-310
    • /
    • 2016
  • The operational cost for maintaining the superconductivity of high-temperature superconducting (HTS) cables needs to be reduced for feasible operation. It depends on factors such as AC loss and heat transfer from the outside. Effective operation requires design optimization and suitable operational conditions. Generally, it is known that critical currents increase and AC losses decrease as the operational temperature of liquid nitrogen ($LN_2$) is lowered. However, the cryo-cooler consumes more power to lower the temperature. To determine the effective operational temperature of the HTS cable while considering the critical current and AC loss, critical currents of the HTS cable conductor were measured under various temperature conditions using sub-cooled $LN_2$ by Stirling cryo-cooler. Next, AC losses were measured under the same conditions and their variations were analyzed. We used the results to select suitable operating conditions while considering the cryo-cooler's power consumption. We then recommended the effective operating temperature for the HTS cable system installed in an actual power grid in KEPCO's 154/22.9 kV transformer substation.

A Study on the Short Circuit Characteristic of Metallic Stabilizer Free Coated Conductor for FCL Application

  • Park, Dong-Keun;Kim, Min-Jae;Yang, Seong-Eun;Kim, Young-Jae;Chang, Ki-Sung;Na, Jin-Bae;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.4
    • /
    • pp.37-40
    • /
    • 2007
  • As power demands increase, development of the superconducting fault current limiter (SFCL) is being watched with interest. Many types of SFCLs using various superconducting materials have been developed. Especially, the FCL using coated conductor (CC) has been investigated actively at present. CCs have many advantages for the FCL application. YBCO materials used in CCs have a high n-value, and it is relatively easy to choose a matrix of the CC for high resistivity. If the CC has high resistivity, high voltage can be applied to the CC. Then total length of the CC used in SFCL, which has effects on total price and volume of the SFCL, can be reduced. Short circuit tests of two different types of CCs in the liquid nitrogen bath and its sub-cooled condition were performed and analyzed. An effect of high resistivity of the CC and cooling methods on fault current limiting characteristics could be verified in this paper.