• Title/Summary/Keyword: structure sensitivity study

Search Result 678, Processing Time 0.031 seconds

A Study on Social Perceptions of Public Libraries Utilizing the sentiment analysis

  • Noh, Younghee;Kim, Dongseok
    • International Journal of Knowledge Content Development & Technology
    • /
    • v.12 no.4
    • /
    • pp.41-65
    • /
    • 2022
  • This study would understand the overall perception of our society about public libraries, analyzing the texts related to public libraries, utilizing the semantic connection network & sentiment analysis. For this purpose, this study collected data from the last five years with keywords, 'Library' and 'Lifelong Learning Center' from January 1, 2016 through November 30, 2020 through the blogs and cafés of major domestic portal sites. With the collected data, text mining, centrality of keywords, network structure, structural equipotentiality, and sensitivity analyses were conducted. As a result of the analysis, First, 'reading' and 'book' were identified as representative keywords that form the social perception of public libraries. Second, it turned out that there were keywords related to the use of the library and the untact service due to the recent spread of COVID-19. Third, in seeking a plan for the development of public libraries through the keywords drawn to have positive meanings, it is necessary to create continuous services that can form a new image of the library, breaking away from the existing fixed role and image of the library and increase the convenience of use. Fourth, facilities and facilities for library services were recognized from a neutral point of view. Fifth, the spread of infectious diseases, social distancing, and temporary closure and closure of libraries are negatively related to public libraries, and awareness of librarians has been identified as negative keywords.

An Experimental Study on the Optimum Installation of Fire Detector for Early Stage Fire Detecting in Rack-Type Warehouses (랙크식 물류창고 조기 화재감지를 위한 최적 화재감지기 설치방법에 관한 실험연구)

  • Choi, Ki Ok;Kim, Dong Suck;Hong, Sung Ho
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.38-45
    • /
    • 2017
  • This paper is an experimental study to find an optimal detection method for detecting fire early in a rack-type warehouse stored with goods. In this study, we constructed rack-type structure with the fourth floor of 13.5 m high and conducted fire experiments which were to measure flow of heat/smoke in rack-type structure and response time of fire detectors. The detectors used at experiments were fixed temperature type detectors, rate of rise detectors, photoelectric smoke detectors, air sampling smoke detectors and flame detectors. The used ignition sources are n-heptane fire for response of heat detection and cotton fire for response of smoke detection. The fixed temperature type detectors, rate of rise detectors and photoelectric detectors were installed to every rack level respectively. The results show that the rate of rise detector should be installed every 2 levels and photoelectric smoke detector should be installed every 4 levels for the early stage fire detection. Air sampling smoke detectors can detect fire early in response to control of sensitivity, but there is a problem in false alarm. The fixed temperature detector is not suitable for early stage fire detection in warehouse and flame detector not worked if flame is not visible, so it need to install combination with other detector.

Structural Health Monitoring System Employing Smart Sensor Technology Part 1: Development and Performance Test of Smart Sensor (스마트 센서 기술을 이용한 구조물 건전도 모니터링 시스템 Part I : 스마트 센서의 개발과 성능평가)

  • Heo, Gwang Hee;Lee, Woo Sang;Kim, Man Goo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.2
    • /
    • pp.134-144
    • /
    • 2007
  • In this study, a smart sensor unit is developed by using the smart sensor technology that is being rapidly developed in recent years for structural health monitoring system, and its performance is evaluated through various experiments, and also, damage detection experiment is performed on a model structure. This paper as the first half of this study contains the development and performance evaluation of the smart sensor. In the latter half of this study, structure damage detection experiment is performed for the application of verified smart sensor unit into structural health monitoring, and it is compared with a wire measurement system. The smart sensor is developed by using high-power wireless modem, MEMS Sensor and AVR microcontroller, and an embedded program is also developed for the control and operation of the sensor unit. To verify the performance of the smart sensor, many experiments are performed for sensitivity and resolution analysis tests, data acquisition by using cantilever beam and shaker, and on-site application using actual bridge. As a result, the smart sensor proves to be satisfactory in its performance.

Reliability Analysis of Concrete Road Bridge Designed with Different Resistance Factor Format (콘크리트 도로교 설계를 위한 저항계수 체계별 신뢰도 분석)

  • Paik, In-Yeol;Sang, Hee-Jung
    • International Journal of Highway Engineering
    • /
    • v.13 no.2
    • /
    • pp.147-157
    • /
    • 2011
  • As a background study to apply the reliability-based resistance factors to the domestic concrete bridge design code, a comparative study is conducted for the design results and the reliability indexes obtained by adopting different resistance factor formats to yield the design strength of concrete structures. The design results which are calculated by applying the section resistance factors of the current domestic design code and the material resistance factors of Eurocode are compared for the concrete beam bridge. The reliability index is calculated by considering the uncertainties involved in material, dimension and strength equation during the design procedure to get the strength of concrete structure. Also, the sensitivity analysis is performed to figure out which design variables have great impact on the reliability index. The resistance factors of the current domestic bridge design code, AASHTO LRFD and Eurocode are applied to the bridge design for flexure and shear strength and the results show that the resistance factors of the domestic code give the largest reliability indexes. It is observed that the probabilistic distribution of the live load makes difference for the reliability index and the yield strength of reinforcing steel and the live load have great impact on the reliability of both flexural and shear strength of concrete beam through the sensitivity analysis.

A Study on the Effective Adjustment of Building Insulation Performance and the Application of the Night Purge Ventilation System for Low Energy Building Design (저에너지건축물 설계를 위한 건축물 단열성능의 효과적 조정과 야간외기 도입에 따른 에너지 시뮬레이션 연구)

  • Yun, Hyun-Su;Lee, Tae-Kyu;Kim, Jeong-Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.625-632
    • /
    • 2018
  • This study was done to reduce total energy demand based on resource shortage problems and to provide improvement points for more efficient adjustment of the high insulation standards for saving energy in Korea. The demand sensitivity was fully considered by varying the slope of each building. The energy performance of the building was maximized by the introduction of outdoor air at night. A final low-energy building model was developed with the two measures combined, and the short-term operation of the night-fuzzy ventilation system was simulated. The result showed a reduction of about 6 to 7 percent compared to the base model. The results could have many implications in terms of the need to conduct demand sensitivity analyses in architectural design.

Study on the Operation Characteristics of Heat Detectors through Fire and Wind Tunnel Experiment (풍동실험과 화재실험을 통한 열감지기의 동작특성에 관한 연구)

  • Ryu, Hocheol;Kim, Doohyun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.2
    • /
    • pp.203-209
    • /
    • 2015
  • The heat detector detects heat in the fire and is an important core element of the automatic fire alarm system used generally for every fire prevention objects. The heat detector is distinguished in spot type and spread type and in spot type, there are differential and thermistor types. These heat detectors give a great influence on the loss of people and property according to the sensitivity of response such as operation time and operation temperature in actual fire and in overseas people apply it for the development of products that can be operated in the early stage of fire including certification, quality management, and comparison standard by introducing response time index through the theory of heat balance that considers the heat loss and ventilation tests. In Korea, the response time index is introduced and used in the head of sprinkler products, but it is not applied to the heat detector at present. It is necessary to introduce the response time index that shows the sensitivity of response of the heat detector the installation standard for the heat detector that the response time index is applied should be different according to the fire weight, danger degree of fire, and shape of buildings. Through this study, it tries to help reduce lives and property of people through the swift warning by installing detectors suitable for the building structure.

Evaluation of Design Characteristics in the Reinforced Railroad Subgrade Through the Sensitivity Analysis (민감도 분석을 통한 철도보강노반 설계 특성 평가)

  • Kim, Dae-Sang;Hwang, Sung-Ho;Kim, Ung-Jin;Park, Young-Kon;Park, Seong-Yong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.3
    • /
    • pp.15-22
    • /
    • 2013
  • By changing from ballasted track to concrete slab track, new type railroad subgrade is strongly required to satisfy strict regulations for displacement limitations of concrete slab track. In this study, sensitivity analysis was performed to assess the design characteristics of new type reinforced railroad subgrade, which could minimize residual settlement after track construction and maintain its function as a permanent railway roadbed under large cyclic load. With developed design program, the safety analysis (circular slip failure, overturning, and sliding) and the evaluation of internal forces developed in structural members (wall and reinforcement) were performed according to vertical installation spacing and stiffness of short and long geotextile reinforcement. Based on this study, we could evaluate the applicabilities of 0.4 H short geogrid length with 0.4 m vertical installation spacing of geotextile as reinforcement and what the ground conditions are for the reinforced railroad subgrade. And also, we could grasp design characteristics of the reinforced railroad subgrade, such as the importance of connecting structure between wall and reinforcement, boundary conditions allowing displacement at wall ends to minimize maximum bending moment of wall.

Design of DEA/(AR-I, ARGM) Models and Sensitivity Analysis for Performance Evaluation on Governmental Funding Projects for IT Small and Medium-sized Enterprises (IT중소기업 정부자금 지원정책 성과 평가를 위한 DEA/(AR-I, ARGM) 모형 설계 및 민감도 분석)

  • Park, Sungmin;Kim, Heon;Baek, Donghyun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.34 no.2
    • /
    • pp.190-204
    • /
    • 2008
  • Recently, it has been strongly required to establish a systematic and sustainable performance investigation and evaluation framework on governmental funding projects for IT small and medium-sized enterprises. In this paper, Data Envelopment Analysis (DEA) models are adopted for performance evaluation on governmental funding projects for IT small and medium-sized enterprises. A new data structure is proposed for the DEA performance evaluation. Generally, in using DEA models, DEA multipliers restriction is critical to achieve the reliability of DEA optimal solutions. Based on the outputs and inputs considered in this study, Acceptance Region (AR) constraints are generated and incorporated into the DEA models so as to improve the reliability of DEA efficiency scores. Associated with AR Type I (AR-I), AR Global Model (ARGM) constraints, DEA/ (AR-I, ARGM) models are designed and then sensitivity analysis follows investigating the robustness of DEA efficiency scores relating to AR constraints adjustment. Finally, a performance evaluation is illustrated regarding governmental direct funding projects from Ministry of Information and Communication (MIC) in Korea where each project unit (i.e. Decision Making Unit (DMU)) is determined whether it is efficient or not. By using DEA/(AR-I, ARGM) models designed in this paper, robustly efficient DMUs are gradually identified according to the successive AR constraints adjustment. Among 25 DMUs, results show that 6 DMUs such as B, E, G, Q, S, Y are determined as robustly efficient against AR constraints intermediate adjustment.

A Study on Micro Gas Sensor Utilizing WO$_3$ Thin Films Fabricated by Sputtering Method (스퍼터링법으로 제작한 WO$_3$ 박막을 이용한 NO$_2$ 마이크로 가스센서에 관한 연구)

  • 김창교;이영환;노일호;유홍진;유광수;기창진
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.3
    • /
    • pp.139-144
    • /
    • 2003
  • A flat type micro gas sensor was fabricated on the p-type silicon wafer with low stress Si$_3$N$_4$, whose thickness is 2 ${\mu}{\textrm}{m}$, using MEMS technology. WO$_3$ thin film as a sensing material for detection of NO$_2$ gas was deposited using a tungsten target by sputtering method, followed by thermal oxidation at several temperatures (40$0^{\circ}C$-$600^{\circ}C$) for one hour. NO$_2$ sensitivities were investigated for the WO$_3$ thin films with different annealing temperatures. The highest sensitivity was obtained for the samples annealed at $600^{\circ}C$ when it was operated at 20$0^{\circ}C$. The results of XRD analysis showed the annealed samples had polycrystalline phase mixed with triclinic and orthorhombic structures. The sample exhibits higher sensitivity when the system has less triclinic structure. The sensitivities, $R_{gas}/R_{air},$ operating at 20$0^{\circ}C$ to 5 ppm NO$_2$ of the sample annealed at $600^{\circ}C$ were approximately 90.

  • PDF

A study on the gas reaction mechanism in catalyst/$SnO_2$ gas sensor (촉매/$SnO_2$ 가스 센서의 반응 구조에 관한 연구)

  • 이재홍;김창교;김진걸;조남인;김덕준
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.7 no.2
    • /
    • pp.276-283
    • /
    • 1997
  • A dry impregnation method was used for preparing pellet type Pt/$SnO_2$ gas sensor. The crystal structure, direction of the crystal, crystal size and microstructure between the catalyst and the support ($SnO_2$) were characterized with electron diffraction analysis, transmission electron microscopy, scanning electron microscopy. The characterization indicates that when Pt/$SnO_2$ sample is calcined at $400^{\circ}C$, the Cl content associated with the Pt phase diminishes and the part of Pt is moved into $SnO_2$ support. This results in the enhancement of gas sensitivity. After the reactor with a Pt/$SnO_2$ sample was run with a flow rate of 30 sccm (a mixture of 0.5% $H_2$ in $_N2$) for a while, the resistance of $SnO_2$ was saturated, but the $SnO_2$ kept absorbing $H_2$ gas. This indicates that the surface state was saturated. For the 14 ppm $H_2$ gas, the sensitivity of Pt/$SnO_2$ devices was about 81% at an operating temperature of $300^{\circ}C$.

  • PDF