• Title/Summary/Keyword: structure parameters

Search Result 5,589, Processing Time 0.044 seconds

The Comparison of Existing Synthetic Unit Hydrograph Method in Korea (국내 기존 합성단위도 방법의 비교)

  • Jeong, Seong-Won;Mun, Jang-Won
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.6
    • /
    • pp.659-672
    • /
    • 2001
  • Generally, design flood for a hydraulic structure is estimated using statistical analysis of runoff data. However, due to the lack of runoff data, it is difficult that the statistical method is applied for estimation of design flood. In this case, the synthetic unit hydrograph method is used generally and the models such as NYMO method, Snyder method, SCS method, and HYMO method have been widely used in Korea. In this study, these methods and KICT method, which is developed in year 2000, are compared and analyzed in 10 study areas. Firstly, peak flow and peak time of representative unit hydrograph and synthetic unit hydrograph in study area are compared, and secondly, the shape of unit hydrograph is compared using a root mean square error(RMSE). In Nakayasu method developed in Japan, synthetic unit hydrograph is very different from peak flow, peak time, and the shape of representative unit hydrograph, and KICT method(2000) is superior to others. Also, KICT method(2000) is superior to others in the aspects of using hydrologic and topographical data. Therefore, Nakayasu method is not a proper in hydrological practice. Moreover, it is considered that KICT model is a better method for the estimation of design flood. However, if other model, i.e. SCS method, Nakayasu method, and HYMO method, is used, parameters or regression equations must be adjusted by analysis of real data in Korea.

  • PDF

A Web-based 'Patterns of Care Study' System for Clinical Radiation Oncology in Korea: Development, Launching, and Characteristics (우리나라 임상방사선종양을 위한 웹 기반 PCS 시스템의 개발과 특성)

  • Kim, Il Han;Chie, Eui Kyu;Oh, Do Hoon;Suh Chang-Ok;Kim, Jong Hoon;Ahn, Yong Chan;Hur, Won-Joo;Chung, Woong Ki;Choi, Doo Ho;Lee, Jae Won
    • Radiation Oncology Journal
    • /
    • v.21 no.4
    • /
    • pp.291-298
    • /
    • 2003
  • Purpose: We report upon a web-based system for Patterns of Care Study (PCS) devised for Korean radiation oncology. This PCS was designed to establish standard tools for clinical quality assurance, to determine basic parameters for radiation oncology processes, to offer a solid system for cooperative clinical studies and a useful standard database for comparisons with other national databases. Materials and Methods: The system consisted of a main server with two back-ups in other locations. The program uses a Linux operating system and a MySQL database. Cancers with high frequencies in radiotherapy departments in Korea from 1998 to 1999 were chosen to have a developmental priority. Results: The web-based clinical PCS .system for radiotherapy in www.pcs.re.kr was developed in early 2003 for cancers of the breast, rectum, esophagus, larynx and lung, and for brain metastasis. The total number of PCS study items exceeded one thousand. Our PCS system features user-friendliness, double entry checking, data security, encryption, hard disc mirroring, double back-up, and statistical analysis. Alphanumeric data can be input as well as image data. In addition, programs were constructed for IRB submission, random sampling of data, and departmental structure. Conclusion: For the first time in the field of PCS, we have developed a web-based system and associated working programs. With this system, we can gather sample data in a short period and thus save, cost, effort and time. Data audits should be peformed to validate input data. We propose that this system should be considered as a standard method for PCS or similar types of data collection systems.

A Model for the $3_{10}$/$\alpha$ Helix Transitions of $\alpha$-Aminoisobutyric Acid-Alanine Oligopeptide ($\alpha$-아미노이소부틸산-알라닌 올리고 펩티드의 $3_{10}$/$\alpha$ 나선 전이에 관한 모형)

  • Kim, Yeong Gu;Park, Hyeong Seok
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.10
    • /
    • pp.710-718
    • /
    • 1994
  • We suggest a statistical thermodynamic theory for the conformational transition of a synthetic alanine (Ala), ${\alpha}$-aminoisobutyric acid (Aib) alternative oligopeptide, Buo-(Ala-Aib)$_n$-oMe, where the terminal groups Buo and oMe stand for t-butoxy and methoxy, respectively. Pure Aib homo-oligomers have always been found to adopt $3_{10}$ helical conformations, while polyalanine has always $\alpha$ helical conformation. In an organic solvent (e.g. $CD_3$CN) it shows that the length for the $3_{10}$/${\alpha}$ helix transitions of Buo-(Ala-Aib)$_n$-oMe, is 8 at room temperature. In an aqueous solution oligopeptide has always coil conformation at room temperature. In an organic solution, helical structures of the oligopeptide are more stable than coil structure, so we studied the $$3_{10}/\alpha$ helix transitions, considering coiled-conformations, coiled and $3_{10}$ helical conformations, and coiled and $\alpha$ helical conformations by using the zipper model. We determined the values of parameters ($\sigma_A$, $\sigma_T$, $\xi_A$, $\xi_T$) from the relating published data; $\sigma_A$ = 0.00011, $\sigma_T$ = 0.0060, $\xi_A$ = 10.1, $\xi_T$ = 3.90. The distributions of $\alpha$ helical length can be N-2, N-3, N-4, ${\cdots}$, 3, 2, 1 (N = 2n) while those of $3_{10}$ helical length, N-1, N-2, N-3, N-4, ${\cdots}$, 3, 2, 1.

  • PDF

Magnetic and Electric Transport Properties of MnTe Thin Film Grown by Molecular Beam Epitaxy (분자선 증착법에 의해 성장한 MnTe 박막의 자기적 및 전기수송 특성)

  • Kim, Woo-Chul;Bae, Sung-Whan;Kim, Sam-Jin;Kim, Chul-Sung;Kim, Kwang-Joo;Yoon, Jung-Bum;Jung, Myung-Hwa
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.2
    • /
    • pp.81-85
    • /
    • 2007
  • MnTe layers of high crystalline quality were successfully grown on Si(100) : B and Si(111) substrates by molecular beam epitaxy (MBE). Under tellurium-rich condition and the substrate temperature around $400^{\circ}C$, a layer thickness of $700{\AA}$ could be easily obtained with the growth rate of $1.1 {\AA}/s$. We investigated the structural, magnetic and transport properties of MnTe layers by using x-ray diffraction (XRD), superconducting quantum interference device (SQUID) magnetometry, and physical properties measurement system (PPMS). Characterization of MnTe layers on Si(100) : B and Si(111) substrates by XRD revealed a hexagonal structure of polycrystals with lattice parameters, ${\alpha}=4.143{\pm}0.001{\AA}\;and\;c=6.707{\pm}0.001{\AA}$. Investigation of magnetic and transport properties of MnTe films showed anomalies unlike antiferromagnetic powder MnTe. The temperature dependence of the magnetization data taken in zero-field-tooling (ZFC) and field-cooling (FC) conditions indicates three magnetic transitions at around 21, 49, and 210 K as well as the great irreversibility between ZFC and FC magnetization in the films. These anomalies are attributable to a magnetic-elastic coupling in the films. Magnetization measurements indicate ferromagnetic behaviour with hysteresis loops at 5 and 300 K for MnTe polycrystalline film. The coercivity ($H_c$) values at 5 and 300 K are 55 and 44 Oe, respectively. In electro-transport measurements, the temperature dependence of resistivity revealed a noticeable semiconducting behaviours and showed conduction via Mott variable range hopping at low temperatures.

Synthesis and Electrochemical Performance of Ni-rich NCM Cathode Materials for Lithium-Ion Batteries (리튬이온전지 양극활물질 Ni-rich NCM의 합성과 전기화학적 특성)

  • Kim, Soo Yeon;Choi, Seung-Hyun;Lee, Eun Joo;Kim, Jeom-Soo
    • Journal of the Korean Electrochemical Society
    • /
    • v.20 no.4
    • /
    • pp.67-74
    • /
    • 2017
  • Layered Ni-rich NCM cathode materials $Li[Ni_xCo_{(1-x)/2}Mn_{(1-x)/2}]O_2$ ($x{\geq}0.6$) have advantages of high energy density and cost competitive over $LiCoO_2$. The discharge capacity of NCM increases proportionally to the Ni contents. However, there is a problem that it is difficult to realize the stable electrochemical performance due to cation mixing. In this study, synthesis conditions for the layered Ni-rich NCMs are investigated to achieve deliver the ones having good electrochemical performances. Synthesis parameters are atmosphere, lithium source, synthesis time, synthesis temperature and Li/M (M=transition metal) ratio. The degree of cation mixing gets worse as the Ni content is increased from $Li[Ni_{0.6}Co_{0.2}Mn_{0.2}]O_2$ (NCM6) to $Li[Ni_{0.8}Co_{0.1}Mn_{0.1}]O_2$ (NCM8). It is confirmed that higher level of cation mixing affects negatively on the electrochemical performance of NCMs. Optimum synthesis conditions are explored for NCMx (x=6, 7, 8) in order to reduce the cation mixing. Under optimized conditions for three representative NCMx, a high initial discharge capacity and a good cycle life are obtained for $180mAh{\cdot}g^{-1}$, 96.2% (50 cycle) in NCM6, $187mAh{\cdot}g^{-1}$, 94.7% (50 cycle) in NCM7, and $201mAh{\cdot}g^{-1}$, 92.7% (50 cycle) in NCM8, respectively.

Influence of Column Aspect Ratio on the Hysteretic Behavior of Slab-Column Connection (슬래브-기둥 접합부의 이력거동에 대한 기둥 형상비의 영향)

  • Choi, Myung-Shin;Cho, In-Jung;Ahn, Jong-Mun;Shin, Sung-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.515-525
    • /
    • 2007
  • In this investigation, results of laboratory tests on four reinforced concrete flat plate interior connections with elongated rectangular column support which has been used widely in tall residential buildings are presented. The purpose of this study is to evaluate an effect of column aspect ratio (${\beta}_c={c_1}/{c_2}$=side length ratio of column section in the direction of lateral loading $(c_1)$ to the direction of perpendicular to $c_1$) on the hysteretic behavior under earthquake type loading. The aspect ratio of column section was taken as $0.5{\sim}3\;(c_1/c_2=1/2,\;1/1,\;2/1,\;3/1)$ and the column perimeter was held constant at 1200mm in order to achieve nominal vertical shear strength $(V_c)$ uniformly. Other design parameters such as flexural reinforcement ratio $(\rho)$ of the slab and concrete strength$(f_{ck})$ was kept constant as ${\rho}=1.0%$ and $f_{ck}=40MPa$, respectively. Gravity shear load $(V_g)$ was applied by 30 percent of nominal vertical shear strength $(0.3V_o)$ of the specimen. Experimental observations on punching failure pattern, peak lateral-load and story drift ratio at punching failure, stiffness degradation and energy dissipation in the hysteresis loop, and steel and concrete strain distributions near the column support were examined and discussed in accordance with different column aspect ratio. Eccentric shear stress model of ACI 318-05 was evaluated with experimental results. A fraction of transferring moment by shear and flexure in the design code was analyzed based on the test results.

Clinical Significance of Nasal Peak Inspiratory Flow Rate in Patients with Chronic Cough (만성기침환자에서 비강최대흡기유속 측정의 의의)

  • An, Chang-Hyeok;Lee, Byung-Hun;Park, Yong-Bum;Choi, Jae-Chul;Jee, Hyun-Suk;Park, Sung-Jin;Kang, Sun-Bok;Kim, Jae-Yeol;Park, In-Won;Choi, Byung-Whi;Hue, Sung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.654-661
    • /
    • 1999
  • Background : The upper respiratory tract is the primary target organ of various airborne pollutants and is easily accessible part of the respiratory tract, and also is the predominant structure where chronic cough originates. The nasal peak inspiratory flow(PIFn), which is the peak inspiratory flow via nose with nasal mask and spirometry, could be a reliable parameter of nasal obstruction. The validity of PIFn has been evaluated in several studies by assessing the correlation between PIFn measurements and other parameters of nasal air flow. This study was designed to show the reproducibility of PIFn, the difference of PIFn between patients with chronic cough and normal subjects, and the usefulness of PIFn in the evaluation of nasal obstruction in patients with chronic cough. Methods : PIFn was measured by spirometry with nasal mask, twice a day for 3 consecutive days in 7 young normal subjects to evaluate validity of the test. In 32 patients with chronic cough and 25 age-matched normal subjects, PIFn and pulmonary function test($FEV_1$, $FEV_1%$ pred, FVC, and FVC% pred) were measured at first visiting. Results : Values of PIFn, $FEV_1$, and FVC were nearly constant in 7 young normal adults. Patients with chronic cough were 32 (14 males and 18 females) and the mean age was $41.4{\pm}15.9$ years. Normal subjects were 32(22 males and 10 females) and the mean age was $39.8{\pm}18.6$ years. There was no significant difference of age and pulmonary function test between patients with chronic cough and normal subjects(p<0.05). The PIFn values in patients with chronic cough was significantly lower than those of normal subjects($2.25{\pm}0.68\;L/sec$ vs. $2.75{\pm}1.00\;L/sec$ ; p=0.02). The postnasal drip syndrome(PNDS) comprised the majority of patients with chronic cough(27). The PIFn in patients with PNDS was significantly lower than that of normal subjects (mean$\pm$SD ; $2.18{\pm}0.66$ vs. $2.75{\pm}1.00\;L/sec$, p=0.006). Conclusion : There was a significant difference of PIFn between patients with chronic cough and normal subjects. Among the patients with chronic cough, patients with PNDS showed the most significant difference with normal subjects in PIFn. The PIFn could be a useful parameter of nasal obstruction in patients with chronic cough, especially in patients with PNDS.

  • PDF

Left ventricular dysfunction measured by tissue Doppler imaging and strain rate imaging in hypertensive adolescents (고혈압 청소년에서 tissue Doppler imaging과 strain rate imaging을 이용한 좌심실 기능 이상에 대한 연구)

  • Ahn, Hye Mi;Jung, Sun Ok;Kwon, Jung Hyun;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.1
    • /
    • pp.72-79
    • /
    • 2010
  • Purpose: Left ventricular (LV) hypertrophy and impaired diastolic function may occur early in systemic hypertension. Diastolic dysfunction is associated with increased cardiovascular risk. Tissue Doppler imaging (TDI)-derived tissue velocity and strain rate are new parameters for assessing diastolic dysfunction. The aim of this study is to determine whether TDI and strain rate imaging (SRI) would improve the ability to recognize early impaired diastolic and systolic functions compared with conventional echocardiography in hypertensive adolescents. Methods: We included 38 hypertensive patients with systolic blood pressure above 140 mmHg or diastolic blood pressure above 90 mmHg. Ejection fraction and myocardial performance index (MPI) were estimated by conventional echocardiography. Peak systolic myocardial velocity, early diastolic myocardial velocity (Em), and peak late diastolic myocardial velocity (Am) were obtained by using TDI and SRI. Results: In the hypertensive group, interventricular septal thickness was significantly increased on M-mode echocardiography. Em/Am was significantly decreased at the mitral valve annulus. Among hypertensive subjects, the E strain rate at basal, mid, and apex was significantly decreased. Systolic strain was significantly decreased at the septum in the hypertensive group. Conclusion: Strain rate might be a useful new parameter for the quantification of both regional and global LV functions and could be used in long-term follow up in hypertensive patients. Early identification by SRI of subjects at risk for hypertensive and ventricular dysfunction may help to stratify risk and guide therapy. Further studies, including serial assessment of LV structure and function in a larger number of adolescents with hypertension, is necessary.

The Limnological Survey of a Coastal Lagoon in Korea (4); Lake Songji (동해안 석호의 육수학적 조사 (4); 송지호)

  • Kwon, Sang-Yong;Heo, Woo-Myung;Lee, Sang-Ha;Kim, Dong-Jin;Kim, Bom-Chul
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.4 s.114
    • /
    • pp.461-474
    • /
    • 2005
  • Physicochemical parameters, plankton community structure, and sediment were surveyed from 1988 to 2002, at two months interval, in a eutrophic coastal lagoon (Lake Songji, Korea). The lake basin is separated from the sea by a narrow sand dune, and a shallow sill divides the lake basin into two sub-basins. The stable stratifications and chemoclines are maintained all through the year at 1-2 m depth. DO was often very low (<1 $mgO_2\;{\cdot}\;L^{-1}$) in the monimolimnion. Secchi disc transparency was in the range of 0.5-2.7 m. TP, TN, and Chl. a concentration in the mixolimnion were 0.015-0.396 $mgP\;{\cdot}\;L^{-1}$), 0.223-3.521 $mgN\;{\cdot}\;L^{-1}$, and 0.5-129.8 mg ${\cdot}\;m^{-3}$, respectively. TSI was in the eutrophic range of 54 to 62. Sediment was composed of silt and coarse silt. COD, TP, and TN content of the sediment were 51.4-116.9 $mgO_2\;{\cdot}\;gdw^{-1}$, 0.04-1.46 $mgP\;{\cdot}\;gdw^{-1}$ and, 0.12-1.03 $mgN\;{\cdot}\;gdw^{-1}$, respectively. The 49 phytoplankton species were identified. The maximum phytoplankton abundance obscured the lake in September 2001 (max. density: 23,350 cells ${\cdot}\;mL^{-1}$. The Chlorophyte Schroederia judayi was dominant species in summer (max. density: 20,417 cells ${\cdot}\;mL^{-1}$). The lake showed unique limnological features of a brackish lagoon in respect to biological community, chemical characteristics, and physical phenomena.

Traffic Forecasting Model Selection of Artificial Neural Network Using Akaike's Information Criterion (AIC(AKaike's Information Criterion)을 이용한 교통량 예측 모형)

  • Kang, Weon-Eui;Baik, Nam-Cheol;Yoon, Hye-Kyung
    • Journal of Korean Society of Transportation
    • /
    • v.22 no.7 s.78
    • /
    • pp.155-159
    • /
    • 2004
  • Recently, there are many trials about Artificial neural networks : ANNs structure and studying method of researches for forecasting traffic volume. ANNs have a powerful capabilities of recognizing pattern with a flexible non-linear model. However, ANNs have some overfitting problems in dealing with a lot of parameters because of its non-linear problems. This research deals with the application of a variety of model selection criterion for cancellation of the overfitting problems. Especially, this aims at analyzing which the selecting model cancels the overfitting problems and guarantees the transferability from time measure. Results in this study are as follow. First, the model which is selecting in sample does not guarantees the best capabilities of out-of-sample. So to speak, the best model in sample is no relationship with the capabilities of out-of-sample like many existing researches. Second, in stability of model selecting criterion, AIC3, AICC, BIC are available but AIC4 has a large variation comparing with the best model. In time-series analysis and forecasting, we need more quantitable data analysis and another time-series analysis because uncertainty of a model can have an effect on correlation between in-sample and out-of-sample.