• Title/Summary/Keyword: structural seismic response

Search Result 1,317, Processing Time 0.023 seconds

Influence of incident angles of earthquakes on inelastic responses of asymmetric-plan structures

  • Nguyen, Van Tu;Kim, Dookie
    • Structural Engineering and Mechanics
    • /
    • v.45 no.3
    • /
    • pp.373-389
    • /
    • 2013
  • This paper presents the influence of incident angles of earthquakes on inelastic dynamic responses of asymmetry single story buildings under seismic ground motions. The dynamic responses such as internal forces and rotational ductility factor are used to evaluate the importance of the incident angles of ground motions in the inelastic range of structural behavior. The base shear and torque (BST) response histories of the resisting elements and of the building are used to prove that the shape of the BST surface of the building can be a practical tool to represent those of all resisting elements. This paper also shows that the different global forces which produce the maximum demands in the resisting elements tend to converge toward a single distribution in a definable intensity range, and this single distribution is related to the resistance distribution of the building.

An Efficient Inelastic Analysis of a Moment Frame Steel Structure with Reduced Beam Section (Reduced Beam Section을 가진 철골모멘트 골조의 효율적인 비탄성 해석)

  • 조소훈;박찬헌;이동근
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.10a
    • /
    • pp.503-510
    • /
    • 2004
  • One of the methods improving the seismic behavior of a structure is the frame with reduced beam section (RBS) which cuts a segment of flanges of the beam near the beam-to-column connection so that the section with reduced flanges has smaller flexural strength than the beam end. It is difficult to analyze the RBS frame because RBS portion has circular-cut type flange. And inelastic response of the steel frame with the RBS is very sensitive to the RBS model. In this paper, the analytical models of RBS portion are investigated and the results of the inelastic analysis for RBS analytical models are compared and then the analytical model for RBS is determined based on the results of inelastic analysis. Inelastic behavior of the RBS frame and its dynamic characteristics are investigated for selected analytical model of RBS.

  • PDF

Dynamic Instability of Diagonally Braced Steel Frames under Seismic Excitation (대각선 철골 중심가새골조의 지질동하에서의 동적불안정 거동)

  • 김정재;이철호
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.10a
    • /
    • pp.288-295
    • /
    • 2004
  • Concentrically braced steel frames are considered as being quite pone to soft-story response due to the degradation in brace compressive resistance after buckling under severe ground motions. When combined with the system P-Delta effects, collapse of the concentrically brsced frames by dynamic instability becomes highly probable. In this stidy, a new, relatively simple dynamic instability coefficient was proposed for diagonally braced steel flames by explicitly considering the strength degradation of the brace after buckling. Nonlinear dynamic analysis results showed that the dynamic instability coefficient proposed in this study predicted collapse limit state more consistently than the conventional one which ignores the strength degradation of the brace.

  • PDF

Capacity and Placement of MR Damper for Vibration Control of MDOF System (다자유도 시스템의 진동제어를 위한 MR감소기 용량 및 위치 선정)

  • 이상현;민경원;이루지;김대곤
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.10a
    • /
    • pp.34-40
    • /
    • 2004
  • In this paper, peliminary design procedure of magnetorheological (MR) dampers is developed for controlling the building response induced by seismic excitation. Hysteretic biviscous model which is simple and can describe the hysteretic characteristics of MR damper is used for parametric studies. The capacity of MR damper is determined as a portion of not the building weight but the lateral restoring force. A method is proposed for the optimal placement and number of MR dampers, and its effectiveness is verified by comparing it with the simplified search algorithm. Numerical results indicate that the capacity, number and the placement can be reasonably determined using the proposed design procedure.

  • PDF

Seismic Response Analysis of Reinforced Concrete Wall Structure Using Macro Model

  • Kim, Dong-Kwan
    • International Journal of Concrete Structures and Materials
    • /
    • v.10 no.1
    • /
    • pp.99-112
    • /
    • 2016
  • During earthquake, reinforced concrete walls show complicated post-yield behavior varying with shear span-to-depth ratio, re-bar detail, and loading condition. In the present study, a macro-model for the nonlinear analysis of multi-story wall structures was developed. To conveniently describe the coupled flexure-compression and shear responses, a reinforced concrete wall was idealized with longitudinal and diagonal uniaxial elements. Simplified cyclic material models were used to describe the cyclic behavior of concrete and re-bars. For verification, the proposed method was applied to various existing test specimens of isolated and coupled walls. The results showed that the predictions agreed well with the test results including the load-carrying capacity, deformation capacity, and failure mode. Further the proposed model was applied to an existing wall structure tested on a shaking table. Three-dimensional nonlinear time history analyses using the proposed model were performed for the test specimen. The time history responses of the proposed method agreed with the test results including the lateral displacements and base shear.

Performance of LQR and H$_2$ Controller for an Experimentally-Identified Structure with AMD (AMD가 설치된 실험모델에 대한 LQR과 H$_2$제어기의 설계 및 성능비교)

  • 민경원;이승준;주석준;김홍진;박민규
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.04a
    • /
    • pp.461-470
    • /
    • 2003
  • This paper discusses a time domain controller, LQR, and a frequency domain controller, H₂, for optimal control of civil structures under seismic loads. Numerical simulations are performed on a three-story structure with Active Mass Driver (AMD), which is experimentally identified. Control effectiveness of each controller for the suppression of third floor acceleration responses is investigated when the similar maximum control force is used. Simulation results indicate that LQR is effective for acceleration response reduction while H₂ controller is efficient for utilizing control force.

  • PDF

MODIFIED POSTERIOR TIME-STEP ADJUSTMENT TECHNIQUE FOR MDOF SYSTEM IN SUBSTRUCTURING PSEUDODYNAMIC TEST (부분구조 유사동적법에 있어 다자유도 시스템에 대한 수정 시간증분 조정기법)

  • 이원호;강정호
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.10a
    • /
    • pp.473-480
    • /
    • 1998
  • The substructuring pseudodynamic test is a hybrid testing method consisting of a numerical simulation of the earthquake response of an analytical model and a loading test of a specimen. The substructuring pseudodynamic testing technique has been applied to various seismic experiments since it has advantages over the shaking table test to study dynamic behaviors of relatively large scale structures. However, experimental errors are inevitable in substructuring pseudodynamic testing. Some of these errors can be monitored during the test, but, due to limitations in control system, they cannot be eliminated. For example, one cannot control exactly the displacements that are actually imposed on the structures at each time step. This paper focuses on a technique to minimize the cumulative effect of such control errors for MDOF system. For this purpose, the modified posterior adjustment of the time increment from a target value $\Delta$t$_{n}$ to an adjusted value is performed to minimize the effect of the control errors for MDOF system.for MDOF system.

  • PDF

Effect of Aging Parameters on Seismic Response of RC Shear Wall by Sensitivity Analysis (민감도해석을 이용한 철근콘크리트 전단벽 열화변수의 지진응답 영향)

  • Park, Jun-Hee;Choun, Young-Sun;Choi, In-Kil
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.665-668
    • /
    • 2011
  • 철근콘크리트 구조물은 타설 후 시간이 경과함에 따라 물리적인 요인과 화학적인 요인으로 인하여 열화가 발생한다. 열화를 고려한 구조해석에서 모든 열화 관련 변수를 고려하는 것은 비효율적이다. 따라서 구조물의 거동과 밀접한 관련이 있는 중요열화변수를 정의하는 것이 필요하다. 본 연구에서는 철근콘크리트 전단벽의 경년열화 해석시 중요변수를 고려하기 위하여 민감도해석을 수행하였다. 해석결과에 의하면 재료의 경화와 관련한 변수들이 열화와 관련한 변수들보다 지진응답이 민감하게 나타났다. 해석모델의 낮은 철근비로 인하여 콘크리트의 탈락에 의한 지진응답의 변화보다 철근의 단면손실에 의한 지진응답의 변화가 크게 나타났다. 만약 원전과 같이 철근비가 높은 전단벽에서는 철근의 단면손실도 지진응답에 대한 중요변수가 될 수 있을 것으로 사료된다.

  • PDF

Seismic Analysis of Traveling Sea Water Screen (해수 여과장치의 내진해석)

  • Kim, Heung-Tae;Lee, Young-Shin;Park, Young-Moon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.462-465
    • /
    • 2011
  • 본 논문에서는 유한요소모델을 사용하여 원자력 발전용 해수 여과장치에 대한 동적 내진해석을 수행하였다. 장치의 검증을 위해서 운전기준지진(Operating Basis Earthquake, OBE)과 안전정지지진(Safe Shutdown Earthquake, SSE)이 설계하중으로 작용하였을 때 부재에 미치는 영향을 평가하였다. 해석대상은 유한요소법을 사용하여 수학적 모델링을 완성하였고, 층응답스펙트럼(Floor Response Spectrum, FRS)에 따른 지진하중과 사하중등을 적용하여 해석을 수행하였다. 해석된 해수여과장치의 최대변위는 OBE 조건에서 2.5 mm 이고, SSE 조건에서 최대변위는 4.6 mm 이다. 최대응력은 OBE 조건에서 24 MPa, SSE 조건에서 44 MPa이며, 이 값은 재료의 항복강도의 각각 18%, 27% 수준이다. 이에 따라 지진하중조건에 따른 해수여과장치의 구조적 안전성이 제시되었다.

  • PDF

Damage Assessment and Aseismic Capacity Evaluation of Existing Structures (기설구조물의 손상도 및 내진능력 평가방법)

  • 윤정방;송종걸;김유진
    • Computational Structural Engineering
    • /
    • v.11 no.3
    • /
    • pp.199-212
    • /
    • 1998
  • 본 연구에서는 기설구조물에 대한 손상도 추정기법과 내진능력평가 방법에 대하여 연구하였다. 구조물의 손상도를 추정하는 방법으로는 소수의 계측 데이터를 이용한 모드섭동법(inverse modal perturbation)을 이용하였다. 구조물의 손상은 강성행렬의 감소로 표현하여, 각 요소행렬에 대한 손상을 손상지수를 사용하여 나타내었다. 구조적 손상과 이에 기인한 고유진동 특성의 변화량과의 관계를 섭동방정식으로부터 구한 후, 이로부터 손상지수와 고유진동 특성의 변화량과의 관계를 유동하였다. 따라서 손상 전과 후에서 구조물의 고유진동수와 모드형상을 측정하여 섭동식의 해를 구함으로써 구조물의 강성행렬의 감소로 나타나는 구조물의 손상도를 추정하게 된다. 손상도 추정에 의해 평가된 강성의 변화량에 기인한 손상 후의 기설구조물의 지진응답, 내진능력과 지진손상도의 평가를 손상전과 비교하였다. 내진능력은 구조부재에서 회전연성도 능력의 경험식을 이용하여 평가하였고, 지진손상도의 평가는 가장 많이 사용되는 방법인 Park & Ang 방법을 사용하였다. 예제해석은 다른 지진하중을 받는 2층과 8층의 예제구조물에 대해서 수행하였다.

  • PDF