• Title/Summary/Keyword: structural fragility

Search Result 273, Processing Time 0.025 seconds

Implications of bi-directional interaction on seismic fragilities of structures

  • Pramanik, Debdulal;Banerjee, Abhik Kumar;Roy, Rana
    • Coupled systems mechanics
    • /
    • v.5 no.2
    • /
    • pp.101-126
    • /
    • 2016
  • Seismic structural fragility constitutes an important step for performance based seismic design. Lateral load-resisting structural members are often analyzed under one component base excitation, while the effect of bi-directional shaking is accounted per simplified rules. Fragility curves are constructed herein under real bi-directional excitation by a simple extension of the conventional Incremental Dynamic Analysis (IDA) under uni-directional shaking. Simple SODF systems, parametrically adjusted to different periods, are examined under a set of near-fault and far-fault excitations. Consideration of bi-directional interaction appears important for stiff systems. Further, the study indicates that the peak ground accelertaion, velocity and displacement (PGA, PGV and PGD) of accelerogram are relatively stable and efficient intensity measures for short, medium and long period systems respectively. '30%' combination rule seems to reasonably predict the fragility under bi-directional shaking at least for first mode dominated systems dealt herein up to a limit state of damage control.

Assessment of the Internal Pressure Fragility of the CANDU Type Containment Buildings using Nonlinear Finite Element Analysis (비선형 유한요소해석을 이용한 CANDU형 격납건물의 내압취약도 평가)

  • Hahm, Dae-Gi;Choi, In-Kil;Lee, Hong-Pyo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.4
    • /
    • pp.445-452
    • /
    • 2010
  • In this paper an assessment of the internal pressure fragility of the CANDU type containment buildings is performed. The uncertainties of the performance of the containment buildings, material properties and tendon characteristics are referred from the in-service reports of Wolsung Unit 1. The containment buildings are modeled as a three-dimensional finite elements with considering the major opening and penetrations. A new method to evaluate the probabilistic fragility of the massive structural system is developed. The fragility curves of the target containment building are presented with repect to the failure modes and reliability levels. The center of wall is reveled as the most weak structural component of the containment building in the sense of the rupture and catastrophic rupture failure modes.

Seismic assessment of R/C residential buildings with infill walls in Turkey

  • Korkmaz, Kasim Armagan;Kayhan, Ali Haydar;Ucar, Taner
    • Computers and Concrete
    • /
    • v.12 no.5
    • /
    • pp.681-695
    • /
    • 2013
  • In 1999 Marmara and 2011 Van earthquakes in Turkey, majority of the existing buildings either sustained severe damage or collapsed. These buildings include masonry infill walls in both the interior and exterior R/C frames. The material of the masonry infill is the main variant, ranging from natural stones to bricks and blocks. It is demanding to design these buildings for satisfactory structural behavior. In general, masonry infill walls are considered by its weights not by interaction between walls and frames. In this study, R/C buildings with infill walls are considered in terms of structural behavior. Therefore, 5 and 8-story R/C buildings are regarded as the representative models in the analyses. The R/C representative buildings, both with and without infill walls were analyzed to determine the effects of structural behavior change. The differences in earthquake behavior of these representative buildings were investigated to determine the effects of infill walls leading structural capacity. First, pushover curves of the representative buildings were sketched. Aftermath, time history analyses were carried out to define the displacement demands. Finally, fragility analyses were performed. Throughout the fragility analyses, probabilistic seismic assessment for R/C building structures both with and without infill walls were provided. In this study, besides the deterministic assessment methodology, a probabilistic approach was followed to define structural effect of infill walls under seismic loads.

Fragility analysis of R/C frame buildings based on different types of hysteretic model

  • Borekci, Muzaffer;Kircil, Murat S.
    • Structural Engineering and Mechanics
    • /
    • v.39 no.6
    • /
    • pp.795-812
    • /
    • 2011
  • Estimation of damage probability of buildings under a future earthquake is an essential issue to ensure the seismic reliability. Fragility curves are useful tools for showing the probability of structural damage due to earthquakes as a function of ground motion indices. The purpose of this study is to compare the damage probability of R/C buildings with low and high level of strength and ductility through fragility analysis. Two different types of sample buildings have been considered which represent the building types mentioned above. The first one was designed according to TEC-2007 and the latter was designed according to TEC-1975. The pushover curves of sample buildings were obtained via pushover analyses. Using 60 ground motion records, nonlinear time-history analyses of equivalent single degree of freedom systems were performed using bilinear hysteretic model and peak-oriented hysteretic model with stiffness - strength deterioration for each scaled elastic spectral displacement. The damage measure is maximum inter-story drift ratio and each performance level considered in this study has an assumed limit value of damage measure. Discrete damage probabilities were calculated using statistical methods for each considered performance level and elastic spectral displacement. Consequently, continuous fragility curves have been constructed based on the lognormal distribution assumption. Furthermore, the effect of hysteresis model parameters on the damage probability is investigated.

Seismic Fragility Analysis of Ground Supported Horizontal Cylindrical Tank (수평원통형 저장탱크의 지진취약도 해석)

  • Chaulagain, Nabin Raj;Sun, Chang-Ho;Kim, Ick-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.145-151
    • /
    • 2019
  • The fragility analyses for the partially filled horizontal cylindrical tank having a flexible wall were conducted to evaluate seismic performance. An equivalent simplified model with two lumped masses representing to impulsive and convective masses was used to represent the liquid storage system. This simplified model was validated by comparing its time history analysis results with the 3D FSI model results. The horizontal tank was analyzed under bi-directional excitations. Seismic fragility curves for the stability were developed in transverse and longitudinal directions. Fragility curves show that seismic damage for the horizontal storage system is more susceptible in the transverse direction.

Fragility based damage assesment in existing precast industrial buildings: A case study for Turkey

  • Senel, Sevket Murat;Kayhan, Ali Haydar
    • Structural Engineering and Mechanics
    • /
    • v.34 no.1
    • /
    • pp.39-60
    • /
    • 2010
  • In Turkey, majority of industrial facilities are composed of precast buildings. However, precast buildings have suffered extensive damage during Kocaeli and Duzce (1999) and Adana-Ceyhan (1998) earthquakes. Therefore, in this study, fragilities of existing building stock and damage probabilities of precast buildings were studied. For this purpose, building inventories were prepared and variation of structural parameters was determined by investigating the design project of 65 precast buildings constructed in Denizli, Turkey. Twelve analysis models which reflect the stiffness, strength and ductility properties of building inventory were constructed. After the definition of strain based displacement limits and corresponding damage states for buildings, displacement demands were calculated by using non linear time history analysis. During the analyses 360 strong ground motion records were used. Exceedence ratios of concerned damage limits was calculated by checking the displacement demands and then PGV based fragility curves were constructed. Efficiency of strength, stiffness and ductility properties of existing precast buildings were investigated by comparing the fragility curves. The results have shown that the most effective parameters that govern the damage probabilities of precast buildings are stiffness and ductility. It was also stated that the results of fragility analysis and damage and failure observations performed after Kocaeli and Duzce Earthquakes are compatible.

Static Wind Fragility Analysis of an Extradosed Bridge (엑스트라도즈드교의 정적 풍하중 취약도 분석)

  • Kim, Doo Kie;Kim, Dong Hyawn;Seo, Hyeong Yeol;Lee, Chang Ju
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.5
    • /
    • pp.107-113
    • /
    • 2007
  • This study presents fragility curves for the wind fragility analysis of a six-span extradosed bridge. The loads and corresponding load combinations are calculated using domestic design codes. Random variables are utilized to considering the uncertainties of the input variables for wind loads. The fragility curve is represented as a log-normal distribution function, in which two parameters are estimated by the maximum likelihood method. The results show that the extradosed bridge is safe to suffer static wind forces.

Derivation of analytical fragility curves using SDOF models of masonry structures in Erzincan (Turkey)

  • Karimzadeh, Shaghayegh;Kadas, Koray;Askan, Aysegul;Erberik, M. Altug;Yakut, Ahmet
    • Earthquakes and Structures
    • /
    • v.18 no.2
    • /
    • pp.249-261
    • /
    • 2020
  • Seismic loss estimation studies require fragility curves which are usually derived using ground motion datasets. Ground motion records can be either in the form of recorded or simulated time histories compatible with regional seismicity. The main purpose of this study is to investigate the use of alternative ground motion datasets (simulated and real) on the fragility curves. Simulated dataset is prepared considering regional seismicity parameters corresponding to Erzincan using the stochastic finite-fault technique. In addition, regionally compatible records are chosen from the NGA-West2 ground motion database to form the real dataset. The paper additionally studies the effects of hazard variability and two different fragility curve derivation approaches on the generated fragility curves. As the final step for verification purposes, damage states estimated for the fragility curves derived using alternative approaches are compared with the observed damage levels from the 1992 Erzincan (Turkey) earthquake (Mw=6.6). In order to accomplish all these steps, a set of representative masonry buildings from Erzincan region are analyzed using simplified structural models. The results reveal that regionally simulated ground motions can be used alternatively in fragility analyses and damage estimation studies.

Development of an uncertainty quantification approach with reduced computational cost for seismic fragility assessment of cable-stayed bridges

  • Akhoondzade-Noghabi, Vahid;Bargi, Khosrow
    • Earthquakes and Structures
    • /
    • v.23 no.4
    • /
    • pp.385-401
    • /
    • 2022
  • Uncertainty quantification is the most important challenge in seismic fragility assessment of structures. The precision increment of the quantification method leads to reliable results but at the same time increases the computational costs and the latter will be so undesirable in cases such as reliability-based design optimization which includes numerous probabilistic seismic analyses. Accordingly, the authors' effort has been put on the development and validation of an approach that has reduced computational cost in seismic fragility assessment. In this regard, it is necessary to apply the appropriate methods for consideration of two categories of uncertainties consisting of uncertainties related to the ground motions and structural characteristics, separately. Also, cable-stayed bridges have been specifically selected because as a result of their complexity and the according time-consuming seismic analyses, reducing the computations corresponding to their fragility analyses is worthy of studying. To achieve this, the fragility assessment of three case studies is performed based on existing and proposed approaches, and a comparative study on the efficiency in the estimation of seismic responses. For this purpose, statistical validation is conducted on the seismic demand and fragility resulting from the mentioned approaches, and through a comprehensive interpretation, sufficient arguments for the acceptable errors of the proposed approach are presented. Finally, this study concludes that the combination of the Capacity Spectrum Method (CSM) and Uniform Design Sampling (UDS) in advanced proposed forms can provide adequate accuracy in seismic fragility estimation at a significantly reduced computational cost.

Risk Analysis Considering Structural Damages of Stone Pagoda Structure (석탑구조물의 구조적 손상을 고려한 위험도 분석)

  • Kim, Ho-Soo;Kim, Dong-Kwan;Jeon, Geon-Woo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.4
    • /
    • pp.101-110
    • /
    • 2020
  • In case of stone pagoda structures, the various construction types appear, and various damages occur due to exposure to the outdoors for a long time. Such damages can be classified into non-structural damages and structural damages. However, studies for the effects of structural damages on stone pagoda structures are insufficient. Accordingly, this study intends to perform structural modeling and structural analysis according to structural damages of stone pagoda structure, and to perform risk analysis through the fragility curve. So, we expects that this study gives a great contribution to the preservation and maintenance of stone pagoda structures under the various structural damages.