한국 소방용 방화복에 대한 만족도 조사 (A Survey of Korean Firefighters Regarding their Satisfaction with Protective Clothing)

  • 한설아;남윤자;최영림
    • 복식
    • /
    • 제58권9호
    • /
    • pp.166-175
    • /
    • 2008
  • For the structural firefighting protective clothing, it can show a synergy effect when it satisfies smart fabric to block off a harmful environmental element and ergonomics design that apply range of motion of human body and appropriate size system. There are various standards about the structural firefighting protective clothing, but it's difficult to find a rule about movement suitability because the performance of the material holds a lot of the rules. Therefore, the purpose of this study is to propose a scheme to evaluate the current structural firefighting protective clothing and to improve movement suitability by research on the actual condition. For this, the survey about wearer acceptability scale on design and size and about improvement requirements was executed gathering firefighters' opinion. Questionnaire was composed with 23 items about satisfaction on current structural firefighting protective clothing, body suitability, movement suitability, improvement requirement and subjective information. As a results, Korean firefighters demand ergonomics design of structural firefighting protective clothing which to minimize restriction of body movement and to maximize body suitability.

3차원 인체형상과 3차원 동작분석에 의한 방화복 소매패턴 개발 (Development of Sleeve Patterns of Structural Firefighting Protective Clothing using by 3D Body Shape and 3D Motion Analysis)

  • 한설아;남윤자;윤혜준;이상희;김현주
    • 한국의류산업학회지
    • /
    • 제14권1호
    • /
    • pp.109-121
    • /
    • 2012
  • This study aims at developing ergonomics patterns for the sleeve of structural firefighting protective clothing through 3D motion analysis in order to ensure efficiency and safety of firefighters who are exposed to harmful environment at work. A new research pattern was developed by applying the total results of 3D motion analysis, changes of body surface length measurements, and 2D data on 3D body shape analysis on the size 3 patterns of the existing coat sleeve. For the sleeves, we used the body surface length of the range of shoulder's flexion and the joint angle of the range of wrist's ulnar deviation. And for the production of structural firefighting protective clothing using the research pattern, we recruited a recognized producer of structural firefighting protective clothing designated by KFI. Unlike everyday clothes, structural firefighting protective clothing should be able to fully protect the wearers from the harmful environment that threatens their lives and should not cause any restrictions on their movement. Therefore, the focus of research and development of such protective clothing should be placed on consistent development of new technologies and production methods that will provide protection and comfort for the wearer rather than production cost reduction or operational efficiency. This study is meaningful as it applied 3D motion analysis instead of the existing methods to develop the patterns. In particular, since 3D motion analysis enables the measurement of the range of motion, there should be continuous research on the development of ergonomics patterns that consider workers' range of motion.

한국 소방용 방화복의 치수체계 개발 (Sizing System Development of Korean Structural Firefighting Protective Clothing)

  • 한설아;남윤자;최영림
    • 한국의류학회지
    • /
    • 제33권5호
    • /
    • pp.827-839
    • /
    • 2009
  • Sizing system of Korean structural firefighting protective clothing that is national approved should be met for specification of structural firefighting protective clothing that is identified by Ministry of Public Administration and Security(MOPAS). However if you look over the specification of sizing system, the standard is based on only 'height' and the others are indicated as the size of completed product. KS K ISO 13688 and EN 340 which is met on ISO 13688 which indicates sizing system about protective clothing has the standards of height, chest and waist circumference. Also NFPA 1971 that has standards of sizing system is based on chest circumference, cervical to wrist length, waist circumference and inseam. That is different from Korean standards. Therefore, fire fighting protective clothing standards which is based on only height should be compensated and not be relied on foreign standards like ISO. It is indispensable for developing our own sizing system of structural fire fighting protective clothing. In this studying, Korean new sizing system of structural fire fighting protective clothing was developed for providing basic information of ergonomic structural fire fighting protective clothing. The analyzed target age was between 20 and 59 years old fire fighter who extinguish the fire. And it was analyzed by 3D measurement among data of the $5^{th}$ Size Korea. On conclusion, in case of structural fire fighting protective clothing coat, physical dimension was to be chest circumference, cervical to wrist length. Three dimensions as 5cm space of circumference and four dimensions as 2.5cm space of cervical to wrist length were derived, which means that totally 12 dimensions were defined. Dimension standards of pants was based on the analysis of waist circumference and crotch height. Six dimensions as 5cm space of waist circumference and three dimensions as 5cm space of crotch height were derived, which means that totally 14 dimensions were defined.

과하중 상태에 있는 복합 굴절차의 구조 해석 (Structural Analysis of Overloaded Multi-aerial Platform)

  • 소수현;강성수
    • 한국생산제조학회지
    • /
    • 제22권6호
    • /
    • pp.901-907
    • /
    • 2013
  • The development of high-rise firefighting vehicles warrants thorough structural analysis for ensuring vehicle stability. A few structural analyses were carried out using CAD data, material properties, load conditions, and boundary conditions for evaluating the structural stability of an overloaded multi-aerial platform for firefighting and rescue. Structural analysis was performed with an analytical model consisting of a turntable, six booms, two jib booms, and a basket structure. This model was operated in eight modes. All simulation was performed using NASTRAN, a commercial code. As a result, we confirm that the position of local stress exceeds that of the yield strength. Therefore, stress concentration relaxation is possible by introducing reinforcing boom structures, changing the shape, or imparting a larger moment of inertia to the booms' cross sections.

Application of Deep Learning: A Review for Firefighting

  • Shaikh, Muhammad Khalid
    • International Journal of Computer Science & Network Security
    • /
    • 제22권5호
    • /
    • pp.73-78
    • /
    • 2022
  • The aim of this paper is to investigate the prevalence of Deep Learning in the literature on Fire & Rescue Service. It is found that deep learning techniques are only beginning to benefit the firefighters. The popular areas where deep learning techniques are making an impact are situational awareness, decision making, mental stress, injuries, well-being of the firefighter such as his sudden fall, inability to move and breathlessness, path planning by the firefighters while getting to an fire scene, wayfinding, tracking firefighters, firefighter physical fitness, employment, prediction of firefighter intervention, firefighter operations such as object recognition in smoky areas, firefighter efficacy, smart firefighting using edge computing, firefighting in teams, and firefighter clothing and safety. The techniques that were found applied in firefighting were Deep learning, Traditional K-Means clustering with engineered time and frequency domain features, Convolutional autoencoders, Long Short-Term Memory (LSTM), Deep Neural Networks, Simulation, VR, ANN, Deep Q Learning, Deep learning based on conditional generative adversarial networks, Decision Trees, Kalman Filters, Computational models, Partial Least Squares, Logistic Regression, Random Forest, Edge computing, C5 Decision Tree, Restricted Boltzmann Machine, Reinforcement Learning, and Recurrent LSTM. The literature review is centered on Firefighters/firemen not involved in wildland fires. The focus was also not on the fire itself. It must also be noted that several deep learning techniques such as CNN were mostly used in fire behavior, fire imaging and identification as well. Those papers that deal with fire behavior were also not part of this literature review.

노인복지시설의 소방안전관리실태에 관한 연구 (Study on the Status of Fire Safety Management in Elderly Welfare Facilities)

  • 고왕열;허만성
    • 한국화재소방학회논문지
    • /
    • 제32권3호
    • /
    • pp.108-115
    • /
    • 2018
  • 노인복지시설은 입소자들의 신체적, 정신적 능력이 쇠퇴하여 화재 등의 재난시 많은 인명피해가 발생한다. 본 연구에서는 현재 운영되고 있는 노인복지시설의 건축물 구조적 문제, 소방시설의 설치 및 관리에 관한 문제, 소방안전관리자 업무에 관한 문제점 등 소방안전관리실태에 대해 조사, 분석하였다. 최근 대형화재사고 발생 후 관련법령의 개정에 따른 소방시설의 소급적용 등으로 다소 보완되었으나 전반적으로 소방안전관리실태는 아직도 미비한 상태이다. 따라서 관련법령의 추가적인 정비를 통해 건축물 및 소방시설의 안전성과 소방안전관리실태를 개선해나가야 한다.

냉매용 원터치 삽입식 파이프 조인트의 안전성 구조해석 (Structural Stability Analysis of One-Touch Insertion Type Pipe Joint for Refrigerant)

  • 김은영;박동삼
    • 한국재난정보학회 논문집
    • /
    • 제18권3호
    • /
    • pp.542-549
    • /
    • 2022
  • 연구목적: 파이프는 기계, 전자, 전기, 플랜트 등 많은 산업 분야에서 응용기기로 널리 사용되고 있으며, 소방, 화학 등 안전 관련 분야에서도 널리 사용되고 있다. 제품의 다양화에 따라 배관 분야에서도 기술의 중요성이 높아지고 있습니다. 특히 기존 동관을 스테인리스강으로 변경하는 경우 구조해석이나 유동 해석을 통해 안전성과 유동 특성을 평가할 필요가 있다. 연구방법: 본 연구에서는 자체 개발한 일체형 삽입형 커넥터인 6.35 및 15.88 소켓 모델의 구조적 안정성을 FEM을 이용하여 조사하였다. 구조해석은 전처리기로 hyper mesh, 후처리기로 HYPER VIEW, 솔버로 LS-DYNA를 사용하였다. 연구결과: 응력해석 결과 6.35 소켓의 경우 훅, 훅홀더 및 훅가드에서의 최대응력은 각각 95.02MPa, 19.59MPa 및 44.01MPa였으며, 15.88 소켓의 경우 각각 127.7MPa, 40.09MPa 및 45.23MPa로 나타났다. 결론: 두 소켓 모델의 응력분포를 비교하면 상대적으로 외경이 큰 15.88 소켓에서의 응력이 전반적으로 크게 나타나고 있으나 각 소재의 항복응력보다는 현저히 낮아 두 모델 모두 구조적인 안전성은 문제가 없는 것으로 나타났다.

CFD 해석을 이용한 냉매용 원터치 삽입식 파이프 조인트의 유동 안전성 평가 (Flow Safety Assessment by CFD Analysis in One-Touch Insertion Type Pipe Joint for Refrigerant)

  • 김은영;박동삼
    • 한국재난정보학회 논문집
    • /
    • 제18권3호
    • /
    • pp.550-559
    • /
    • 2022
  • 연구목적: 파이프는 기계, 전자, 전기, 플랜트 등 많은 산업 분야에서 응용기기로 널리 사용되고 있으며, 소방, 화학 등 안전 관련 분야에서도 널리 사용되고 있습니다. 제품의 다양화에 따라 배관 분야에서도 기술의 중요성이 높아지고 있습니다. 특히 기존 동관을 스테인리스강으로 변경하는 경우 구조해석이나 유동 해석을 통해 안전성과 유동특성을 평가할 필요가 있다. 연구방법: 자체 개발한 일체형 인서트형 커넥터인 6.35 소켓 모델의 유동 안전성은 CFD 해석을 이용하여 유동유발진동(FIV) 평가 과정의 4단계를 통해 진행하였다. 연구결과: 배관계 벽면에 작용하는 압력변동의 진폭은 3,780Pa이하의 수준으로 형성되며, 이는 냉매 배관의 운전압력이나 설계응력과 비교했을 때 매우 작은 수준의 압력으로, 난류에 의한 진동이 배관의 구조안전성에 미치는 영향은 미미한 수준인 것으로 나타났다. 결론: 유동 해석을 통하여 후크조인트 체결 시 발생하는 압력 및 진동 등을 검토한 결과 일반적인 배관계의 고유진동수가 50Hz 이하에서 형성되는 것을 고려했을 때, 난류유동에 의해 유발되는 진동이 배관계의 공진을 발생시킬 가능성은 희박한 것으로 판단된다.

국가화재안전기준(NFSC)의 제·개정 시스템 개선에 관한 연구 (A Study on the Systemic Improvement for the Enactment and Revision of the National Fire Safety Code)

  • 송영주;김태우;정기신
    • 한국화재소방학회논문지
    • /
    • 제34권2호
    • /
    • pp.110-119
    • /
    • 2020
  • 화재안전기준은 소방시설법 시행령 별표1에서 규정하고 있는 소방시설에 대한 설치방법 및 기술적 기준을 규정한 것으로 공공의 안전확보와 화재예방을 위한 근간으로서 그 역할을 수행하여왔다. 그러나 현행의 화재안전기준은 성능 기준과 기술기준이 혼재되어있는 형태로 장기간의 개정 절차와 제도적인 경직성으로 인해 기준의 제·개정이 신속하게 진행되기 어렵다. 또한, 기준을 제·개정하고 유지관리 할 수 있는 전문적 상임 독립기구의 부재로 인해 전문성 유지에 한계가 있으며 그 외에도 총의(總意)성, 공개성, 일관성이 결여되는 문제가 있다. 따라서, 이러한 문제점을 극복하기 위해 본 연구에서는 화재안전기준의 변천 및 운영 현황, 법적 성질 및 법적 현황 그리고 제·개정 시의 문제점을 살펴보고 국내·외 유사 기술기준의 운영사례를 비교 분석하여 화재안전기준의 제·개정 시스템을 개선하고자 하였다. 이것을 나타내면 다음과 같다. 첫째, (현(現))국가화재안전기준을 법적 성능 기준과 기술적 세부기준인 기술기준으로 분류한다. 둘째, 기술기준의 제·개정 주체를 기존의 국가에서 민간으로 이양시킨다. 셋째, 기술기준을 사용자 중심의 코드 시스템으로 정비하는 것이다.

선박 구조 개선을 통한 승무원의 피난 효율 향상을 위한 연구 (A study on the efficiency advancement for evacuation of the crews by ship structural improvement)

  • 김원욱;이명호;김종수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권3호
    • /
    • pp.342-348
    • /
    • 2014
  • 육상구조물의 대형화재는 특수한 소방장비와 그에 적합한 방법에 의해서 소방관에 의해서 진압된다. 하지만 해양구조물은 육상으로부터 어떠한 도움없이 승무원에 의해서 진압되고 이들은 선박의 구조적 특성과 선박의 충돌 및 화재와 같은 여러 가지 원인에 의하여 신속한 탈출이 어렵다. 일반적으로 화재에 의한 인명손상의 경우에는 연기에 의한 질식사가 대부분을 차지하므로 탈출 시간의 단축은 생존율을 향상에 아주 중요한 역할을 한다. 본 연구에서는 3차원 화재 분석 전용 프로그램인 FDS(Fire Dynamic Simulator)를 이용하여 화재 발생 시 승무원 생존율 분석을 위한 거주 공간내의 온도 및 연기유동에 의한 가시거리를 분석한다. 기존의 선박은 화재 경보 발령 시 방화문이 자동으로 폐쇄되도록 설계되어 있다. 이는 화재가 발생한 구역에 승무원이 없을 경우에는 화재의 확산 및 연기의 유동 지연에 아주 효과적이다. 그러나 대피시간이 지연될 경우에는 방화문 안쪽에 위치한 승무원들에게는 치명적일 수 있다. 이 논문에서는 화재로 인해 방화문이 폐쇄되어 승무원들이 이 방화문을 열고 탈출하는 경우와 연구에서 제안하는 차단막을 설치했을 경우의 화재 구역의 온도상승 및 연기유동 속도를 비교 분석한다.