• Title/Summary/Keyword: structural fire

Search Result 731, Processing Time 0.026 seconds

Evaluation of Building Envelope Performance of a Dry Exterior Insulation System Using Truss Insulation Frame (트러스 단열 프레임을 이용한 건식 외단열 시스템의 외피 종합 성능 평가)

  • Song, Jin-Hee;Lee, Dong-Yun;Shin, Dong-Il;Jun, Hyun-Do;Park, Cheol-Yong;Kim, Sang-Kyun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.6
    • /
    • pp.153-164
    • /
    • 2019
  • The presence of thermal bridges in a building envelope cause additional heat loss which increases the heating energy. Given that a higher building insulation performance is required in these cases, the heat loss via thermal bridges is a high proportion of the total heat energy consumption of a building. For the dry exterior insulation system that uses mullions and transoms to fix insulation and exterior materials such as stone and metal sheet, the occurrence of thermal bridges at mullions and transoms is one of the main reasons for heat loss. In this study, a dry exterior insulation system using the truss insulation frame (TIF) was proposed as an alternative to metal mullions. To evaluate the building envelope performance, structural, air-leakage, water-leakage, fire-resistance, thermal, and condensation risk tests were conducted. In addition, the annual energy consumption associated with heating and cooling was calculated, including the linear thermal transmittance of the thermal bridges. As a result, the dry exterior insulation system using TIF achieved the allowable value for all tests. It was also determined that the annual heating load of a building was reduced by 36.7 % when the TIF dry exterior insulation system was used, relative to the dry exterior insulation system using steel pipes without additional insulations.

Seismic progressive collapse mitigation of buildings using cylindrical friction damper

  • Mirtaheri, Masoud;Omidi, Zobeydeh;Salkhordeh, Mojtaba;Mirzaeefard, Hamid
    • Earthquakes and Structures
    • /
    • v.20 no.1
    • /
    • pp.1-12
    • /
    • 2021
  • The occurrence of progressive collapse induced by the removal of the vertical load-bearing element in the structure, because of fire or earthquake, has been a significant challenge between structural engineers. Progressive collapse is defined as the complete failure or failure of a part of the structure, initiating with a local rupture in a part of the building and can threaten the stability of the structure. In the current study, the behavior of the structures equipped with a cylindrical friction damper, when the vertical load-bearing elements are eliminated, is considered in two cases: 1-The load-bearing element is removed under the gravity load, and 2-The load-bearing element is removed due to the earthquake lateral forces. In order to obtain a generalized result in the seismic case, 22 pair motions presented in FEMA p 695 are applied to the structures. The study has been conducted using the vertical push down analysis for the case (1), and the nonlinear time-history analysis for the second case using OpenSEES software for 5,10, and 15-story steel frames. Results indicate that, in the first case, the load coefficient, and accordingly the strength of the structure equipped with cylindrical friction dampers are increased considerably. Furthermore, the results from the second case demonstrate that the displacements, and consequently the forces imposed to the structure in the buildings equipped with the cylindrical friction damper substantially was reduced. An optimum slip load is defined in the friction dampers, which permits the damper to start its frictional damping from this threshold load. Therefore, the optimum slip load of the damper is calculated and discussed for both cases.

Post-fire flexural behavior of functionally graded fiber-reinforced concrete containing rubber

  • Nematzadeh, Mahdi;Mousavi, Reza
    • Computers and Concrete
    • /
    • v.27 no.5
    • /
    • pp.417-435
    • /
    • 2021
  • The optimal distribution of steel fibers over different layers of concrete can be considered as an appropriate method in improving the structural performance and reducing the cost of fiber-reinforced concrete members. In addition, the use of waste tire rubber in concrete mixes, as one of the practical ways to address environmental problems, is highly significant. Thus, this study aimed to evaluate the flexural behavior of functionally graded steel fiber-reinforced concrete containing recycled tire crumb rubber, as a volume replacement of sand, after exposure to elevated temperatures. Little information is available in the literature regarding this subject. To achieve this goal, a set of 54 one-, two-, and three-layer concrete beam specimens with different fiber volume fractions (0, 0.25, 0.5, 1, and 1.25%), but the same overall fiber content, and different volume percentages of the waste tire rubber (0, 5, and 10%) were exposed to different temperatures (23, 300, and 600℃). Afterward, the parameters affecting the post-heating flexural performance of concrete, including flexural strength and stiffness, toughness, fracture energy, and load-deflection diagrams, along with the compressive strength and weight loss of concrete specimens, were evaluated. The results indicated that the flexural strength and stiffness of the three-layer concrete beams respectively increased by 10 and 7%, compared to the one-layer beam specimens with the same fiber content. However, the flexural performance of the two-layer beams was reduced relative to those with one layer and equal fiber content. Besides, the flexural strength, toughness, fracture energy, and stiffness were reduced by approximately 10% when a 10% of natural sand was replaced with tire rubber in the three-layer specimens compared to the corresponding beams without crumb rubber. Although the flexural properties of concrete specimens increased with increasing the temperature up to 300℃, these properties degraded significantly with elevating the temperature up to 600℃, leading to a sharp increase in the deflection at peak load.

Comparative Study of Design Loads for the Structural Design of Titanium Leisure Boat (티타늄합금 레저보트의 구조설계를 위한 설계하중 비교연구)

  • Yum, Jae-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.733-738
    • /
    • 2021
  • Recently, people's interest in marine leisure has been increasing, and research and development on leisure boats are actively being carried out to pioneer overseas markets. These days, the materials used for leisure boats are fiber-reinforced plastic (FRP) and aluminum alloy. However, FRP is hygroscopic and causes environmental problems, and aluminum alloy has high thermal conductivity and fire susceptibility. Therefore, titanium alloy is being adopted as a material for leisure boats instead. In this study, hull thicknesses and design pressures were calculated while considering dynamic effects for titanium boats. Four sets of rules and regulations were used: ISO 12215-5, RINA Pleasure Yacht, LR Special Service Craft, and KR High-speed Light Craft. The maximum bottom slamming loads were in the order of ISO, KR, LR, and RINA, and the required hull thicknesses were in the same order. This research might be helpful for understanding the rules, regulations, and overseas export of leisure boats.

The Development and Trend of Eco-Friendly Water-Dispersible Polyurethane Field. (친환경 수분산 폴리우레탄 분야의 개발과 발전 동향)

  • Lee, Joo-Youb
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.6
    • /
    • pp.1533-1542
    • /
    • 2021
  • Eco-friendly polyurethane can be defined as a highly utilized material used in various fields. The various structural properties of the synthesis of isocyanates and polyols provide versatility and customization for use in the manufacturing field. The characteristics of polyurethane vary widely from soft touch coatings to hard building materials like rocks. These mechanical, chemical and biological properties and ease of alignment are drawing tremendous attention not only in the field of research but also in related industries. In order to improve the performance of water-dispersible polyurethane materials, it can be derived through processes such as adjusting the blending of raw materials and adding additives and nanomaterials. This study highlights the basic chemical structure of eco-friendly water-dispersible polyurethane in the fields of medical science, automobiles, coatings, adhesives, paints, textiles, marine industries, wood composite materials, and clothing.

Theoretical Heat Flow Analysis and Vibration Characteristics During Transportation of PCS(Power Conversion System) for Reliability (전력변환장치 캐비넷에서의 내부발열 개선을 위한 열유동 분석 및 유통안전성 향상을 위한 진동특성 분석)

  • Joo, Minjung;Suh, Sang Uk;Oh, Jae Young;Jung, Hyun-Mo;Park, Jong-Min
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.2
    • /
    • pp.143-149
    • /
    • 2022
  • PCS needs to freely switch AC and DC to connect the battery, external AC loads and renewable energy in both directions for energy efficiency. Whenever converting happens, power loss inevitably occurs. Minimization of the power loss to save electricity and convert it for usage is a very critical function in PCS. PCS plays an important role in the ESS(Energy Storage System) but the importance of stabilizing semiconductors on PCB(Printed Circuit Board) should be empathized with a risk of failure such as a fire explosion. In this study, the temperature variation inside PCS was reviewed by cooling fan on top of PCS, and the vibration characteristics of PCS were analyzed during truck transportation for reliability of the product. In most cases, a cooling fan is mounted to control the inner temperature at the upper part of the PCS and components generating the heat placed on the internal aluminum cooling plate to apply the primary cooling and the secondary cooling system with inlet fans for the external air. Results of CFD showed slightly lack of circulating capacity but simulated temperatures were durable for components. The resonance points of PCS were various due to the complexity of components. Although they were less than 40 Hz which mostly occurs breakage, it was analyzed that the vibration displacement in the resonance frequency band was very insufficient. As a result of random-vibration simulation, the lower part was analyzed as the stress-concentrated point but no breakage was shown. The steel sheet could be stable for now, but for long-term domestic transportation, structural coupling may occur due to accumulation of fatigue strength. After the test completed, output voltage of the product had lost so that extra packaging such as bubble wrap should be considered.

A Study on the Near Construction Range Considering the Factors Affecting the Stability of Water Tunnel (수로터널 안정성에 미치는 요소를 고려한 근접시공범위에 대한 연구)

  • Mingyu Lee;Donghyuk Lee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.5
    • /
    • pp.5-12
    • /
    • 2023
  • Recently, due to urban development and expansion, construction plans have been increasing adjacent to existing tunnel structures such as subways, roads, and large pipelines. Structural plans adjacent to existing tunnels have different effects on tunnel stability depending on the construction method, degree of proximity, and location of new structures. In particular, the pressure water tunnel shows a very large difference from other road tunnels and railway tunnels in geotechnical characteristics and operation characteristics. Therefore, it is necessary to review the safety zone due to adjacent construction in consideration of the geotechnical characteristics of the water tunnel and the new sturure construction method. In this study, the existing tunnel safety zone standards were investigated. A stability evaluation performed numerical analysis considering the deterioration of concrete lining in operation and the characteristics of water tunnel. In addition, the impact of vibration caused by pile construction and blasting excavation of new structures was reviewed. Based on this, a pressure water tunnel safety zone was proposed in consideration of adjacent construction.

Performance of aerated lightweighted concrete using aluminum lathe and pumice under elevated temperature

  • Mohammad Alharthai;Yasin Onuralp Ozkilic;Memduh Karalar;Md Azree Othuman Mydin;Nebi Ozdoner;Ali Ihsan Celik
    • Steel and Composite Structures
    • /
    • v.51 no.3
    • /
    • pp.271-288
    • /
    • 2024
  • The primary objective of this study is to investigate the production and performance characteristics of structural concrete incorporating varying proportions (0%, 25%, and 50% by volume) of pumice stone, as well as aluminum lathe as an additive at 0%, 1%, 2%, and 3%, under fire conditions. The experiment will be conducted over a period of up to 1 hour, at temperatures ranging from 24℃, 200℃, 400℃ and 600℃. For the purpose of this, a total of twelve test samples were manufactured, and then tests of compressive strength (CS), splitting tensile strength (STS), and flexural strength (FS) were performed on these samples.Next, a comparison was made between the obtained values and the influence of temperature. To achieve this objective, the manufactured samples were placed at temperatures of 200℃, 400℃, and 600℃ for a duration of 1 hour, and were subjected to the influence of temperature.These values at 24 ℃ were then contrasted with the CS results obtained from test samples that were subjected to the temperature effect for an hour at 200 ℃, 400 ℃, and 600 ℃. A comprehensive analysis of the test outcomes reveals that the incorporation of aluminum lathe wastes into a mixture results in a significant reduction in the compressive strength of the concrete. As a result of this adjustment, the CS values dropped by 32.93%, 45.70%, and 52.07%, respectively. Furthermore, It was shown that testing the ratios of pumice stone alone resulted in a decrease in CS outcomes. Additionally, it was found that the presence of higher temperatures is clearly the primary factor contributing to the decrease in the strength of concrete. Due to elevated temperatures, the CS values decreased by 19.88%, 28.27%, and 38.61% respectively.After this investigation, an equation that explains the connection between CS and STS was provided through the utilization of the data of the experiments that were carried out.

Fire Retardant Treatment to the Plywood with Di-ammonium Phosphate [(NH4)2 HPO4](I) -Hot and Cold Soaking Treatment and Redrying of Treated Plywood by Hot Platen- (제2인산(第二燐酸) 암모늄에 의한 합판(合板)의 내화처리(耐火處理)(I) -온냉침지처리(温冷浸漬處理)와 열판(熱板)에 의한 처리합판(處理合板)의 재건조(再乾燥) -)

  • Lee, Phil Woo;Chung, Woo Yang
    • Journal of Korean Society of Forest Science
    • /
    • v.60 no.1
    • /
    • pp.30-36
    • /
    • 1983
  • Plywood, the representative interior decorative or structural material, is so inflammable that it may cause big fires. Therefore, it is required inevitably to manufacture the "Fire retardant treated plywood", and it will be a study on the redrying of treated plywood that we ought to solve. This study was carried out to investigate the absorption of 20% $(NH_4)_2HPO_4$ solution into the soaked plywoods by hot/cold soaking for 3/3, 6/3, 9/3 and 12/3 hours and to study drying process with drying curves and drying rates by press-drying at the platen temperature of 130, 145, 160 and $175^{\circ}C$. Solution absorption of plywoods in hot/cold soaking method increased steadily with the prolonged soaking time, and water absorption is higher than DAP absorption, and then chemical retention (DAP) exceeded the minimum retention [$1.125kg/(30cm)^3$] even in the shortest soaking treatment. Drying curves of water-soaked plywoods inclined more steeply than those of DAP soaked plywoods. And the drying proceeded rapidly with the increase in platen temperature and terminated in 2.5-4 minutes at the temperature of 160 and $170^{\circ}C$. Drying rate also increased generally with the increase of platen temperature. So it was at $175^{\circ}C$ in DAP-soaking and at $160^{\circ}C$ in water-soaking when the drying rate became above 10%/min.

  • PDF

A Prototype for Real-time Indoor Evacuation Simulation System using Indoor IR Sensor Information (적외선 센서정보기반 실시간 실내 대피시뮬레이션 시스템 프로토타입)

  • Nam, Hyun-Woo;Kwak, Su-Yeong;Jun, Chul-Min
    • Spatial Information Research
    • /
    • v.20 no.2
    • /
    • pp.155-164
    • /
    • 2012
  • Indoor fire simulators have been used to analyse building safety in the events of emergency evacuation. These applications are primarily focused on simulating evacuation behaviors for the purpose of checking building structural problems in normal time rather than in real time situations. Therefore, they have limitations in handling real-time evacuation events with the following reasons. First, the existing models mostly experiment the artificial situations using randomly generated evacuees while real world requires actual data. Second, they take too long time in operation to generate real time data. Third, they do not produce optimal results to be used in rescueing or evacuation guidance. In order to solve these limitations, we suggest a method to build an evacuation simulation system that can be used in real-world emergency situations. The system performs numerous simulations in advance according to varying distributions of occupants. Then the resulting data are stored in DBMS. The actual person data captured in infrared sensor network are compared with the simulation data in DBMS and the querried data most closely is provided to the user. The developed system is tested using a campus building and the suggested processes are illustrated.