• Title/Summary/Keyword: structural evaluation

Search Result 4,836, Processing Time 0.031 seconds

Behaviour of Concrete Building with High Temperature (콘크리트의 고온에서의 거동)

  • 이병곤;태순호
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.2
    • /
    • pp.140-145
    • /
    • 1997
  • The main purpose of this study is to establish the reliable method for evaluating fire damage of reinforced concrete building, by using the rational procedure, and to develope the rehabilitation methods of fire damaged concrete structures. Especially, this proposed evaluation method is applied to the fire damaged concrete buildings of domestic, and the rehabilitation methods on the basis of these applied results are proposed and those example are shown. The proposed rational evaluation method for fire damaged concrete building proceeds is estimating the reduction of the mechanical properties of concrete of fire damaged structural members in comparison with the experimental results which are obtained from the compression tests of heated concrete specimens under various temperatures.

  • PDF

Development of the Evaluation Element for Fire Engineering Design (건축물의 성능적 내화설계 평가 요소기술 개발)

  • Kwon, In-Kyu;Kim, Heung-Youl
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.410-414
    • /
    • 2009
  • Performance based fire engineering design should be developed through basic survey and fundamental element such as analytic program for evaluation of fire performance of building. The basic elements will be expressed to the surveys of the structures of building laws, regulation and the fundamental elements consist of technical guidances contained design fires, heat analysis, determination of structural performance.

  • PDF

Development of indicators for the evaluation of internet site for health information (인터넷 건강정보 사이트 평가지표 개발)

  • Kim, Yong-Soon;Park, Ji-Won;Yoo, Moon-Sook
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.6 no.2
    • /
    • pp.291-298
    • /
    • 2000
  • Objective : Use of Internet for health related information is rapidly increasing. There is, however, no consensus as to which information is correct and reliable. This study was conducted to develop an evaluation standards for health related information on the Internet for the purpose of delivering correct information to internet users. Methods : A Delphi technique, which involved a panel of 65 experts, was used as the research design for this study. In the first round, the initial evaluation criteria which consisted of 12 items was developed through a literature review by the researcher and the items represented 2 categories, structure and function. In the second round, a semi-structured questionnaire was sent to the experts with the initial evaluation tool and the respondents identified 55 items. In the third round, these 55 items were analyzed for content validity by the experts and a total of 35 items were included in the model; 11 items in the structural area, 24 in the functional area. Conclusions : Development of indicators for the evaluation of internet site for health information is crucial to provide correct and reliable information. For evaluation to be effective further evaluation programs need to be developed so that users can be sure that the information they received is accurate.

  • PDF

Structural Performance of the Cast-in-place Anchor in Cracked Concrete used in Power Plant Facilities (균열 콘크리트에 매립된 발전설비 현장설치용 선 설치 앵커의 구조성능 평가)

  • Kim, Dong-Ik;Jung, Woo-young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.120-128
    • /
    • 2019
  • It is very important to verify the seismic performance and stability of the power plant fixture in the domestic power plant, because earthquakes have increased in frequency around the world which resulted in the frequent occurrence of power plant damage caused by the failure of electric power facilities. In this study, through the on-site inspection of power plant fixation unit installed in domestic power plants, we carried out structural performance evaluation of the fixation unit anchor bolts installed on the concrete slabs. The field survey showed M12 J hook anchor bolts were used. Anchor bolt pullout and shear performance evaluation were performed based on ASTM E 488-96 standard. Moreover, artificial crack with the width of 0.5 mm was applied during the experiment based on ATM355.4 and ETAG 001. The comparison of M12 J hook anchor bolt pullout and shear test result to design value required in domestic and international design standard, show a satisfactory result. M12 J hook anchor pullout and shear performance was found to be about 35% and 7%, respectively, higher than the required design value.

Performance of Constructed Facilities: Pavement Structural Evaluation of William P Hobby Airport in Houston, Texas

  • Kim, Sung-Hee;Jeong, Jin-Hoon;Kim, Nak-Seok
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.1
    • /
    • pp.21-25
    • /
    • 2009
  • The results of a recent case study for material characterizations and structural evaluation to design asphalt overlay thickness of William P Hobby airport in Houston, Texas are presented herein. The existing runway 12R-30L of Hobby airport consisted of thick asphalt overlay over Portland Cement Concrete (PCC) and the localized surface shoving as evident in the closure of surface groove has been observed recently. Using the field cored asphalt concrete mixtures, measurements of percent air voids, asphalt content and aggregate gradation were conducted to find out the causations of surface shoving and groove closure. The FAA layered elastic program, LEDFAA was utilized to evaluate pavement structural conditions for new asphalt overlay. Two different composition assumptions for existing pavement were made to evaluate the pavement as followings: 1) APC, Asphalt Concrete Overlay over PCC pavement and 2) AC, Asphalt Concrete pavement. Based on laboratory testing results, a ratio of percent passing #200 to asphalt content ranged 1.1 to 2.2, which is considered a high ratio and a tendency of tender mix design was observed. Thus, the localized surface shoving and groove closure of the runway 12R-30L could be attributed to the use of excessive fine contents and tender mix design. Based on the structural evaluation results, it was ascertained that the analysis assuming the pavement structure as AC pavement gives more realistic structural life when the asphalt overlay is thicker enough compared to PCC layer because the existing PCC pavement under asphalt overlay acts more like a high quality base material.

Analysis of Structural Safety for Rebar Exposure and Corrosion in PSC I-Girder Bridge Slab (PSC I형 교량 바닥판의 철근노출 및 부식에 대한 구조적 안전성 분석)

  • Han, Manseok;Park, Ju-Hyun;Lee, Jong-Han;Min, Jiyoung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.1
    • /
    • pp.67-74
    • /
    • 2021
  • This paper evaluated the structural safety of an aging PSC I-girder bridge with rebar corrosion in the deck. The geometry and rebar of the bridge were designed based on an actual PSC I-girder bridge, and the numerical analysis was performed considering the crack of concrete and yielding of steel rebar. According to the evaluation criteria of Korea Infrastructure Safety and Technology Corporation, this study defined two criteria of rebar exposure and corrosion rates to construct a total of 32 corrosion scenarios. Rebar exposure was defined as the exposure of tensile rebars in the bridge deck due to the removal of cover concrete. The results of the analysis showed that the safety and rating factors of the bridge decreased with increasing rebar exposure and corrosion rates. For the rebar corrosion rate more than 50%, the safety grade of the bridge should be carefully evaluated for all the rebar exposure rate. When the rebar corrosion rate exceeds 57%, the bridge was evaluated as E grade regardless of rebar exposure rate. A correlation analysis for a 2% of rebar exposure rate found that the bridge was evaluated as A grade up to 55.8% corrosion rate, C grade up to 56.9%, D grade up to 58.5%, and E grade for corrosion rate greater than 58.5%. This study indicates the necessity of a quantitative evaluation of rebar corrosion for evaluating the structural safety of aging bridges.

Development of Reuse Process Through Recovery and Refinement of Precursor for LED (LED용 precursor 재이용을 위한 회수 및 정제 공정 개발)

  • Yang, Jae Yeol;O, Byung Sung;Yoon, Jae Sik
    • Resources Recycling
    • /
    • v.23 no.1
    • /
    • pp.25-32
    • /
    • 2014
  • The purpose of this research is to develop a process and a system to collect, purify and reuse the residual quantity of trimethylgallium, used as a raw material, upon GaN epitaxial growth for LED from a metal organic chemical vapor deposition(MOCVD) equipment. This research reviews whether TMGa collected from the process can be used through a chemical and structural characteristics evaluation. As a result of analyzing the purity using ICP-MS and ICP-AES, 7N high purity (99.99999%) of TMGa was obtained. According to checking the structural change of TMGa through NMR analysis, TMGa having pure $(CH_3)_3Ga$ structure was obtained without structural change. For reliability review of the collected TMGa, u-GaN was deposited using the MOCVD process and an structural, optical and electrical characteristics evaluation was conducted. As a result, it was found out that the reuse was possible.

Forensic Engineering Study on Structural Integrity Evaluation of Scaffolding System Tower using ANSYS (ANSYS를 이용한 스캐폴딩 시스템 타워 구조 건전성 평가에 관한 법공학적 연구)

  • Kim, J.H.;Kim, E.S.;Park, W.S.;Moon, B.S.;Goh, J.M.;Park, N.K.;Yoon, K.B.;Cho, S.W.
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.6
    • /
    • pp.42-48
    • /
    • 2013
  • Forensic engineering is the application of engineering principles covering the investigation of constructed facilities and systems that fail to perform as intended, causing personal injury or damage to property, environmental, economy etc. In the year 2012, two collapsed accidents of the large scaffolding system in national thermal power station occurred one after another, causing many casualties. In this study, we had performed to investigate the collapsed accident of scaffolding system occurred in the a thermal power station of two accidents. First, the investigation about the collapsed accidents site had performed to understand collapsed state and structures of the scaffolding system. Second, reviewing the materials concerning about the applied weight on the scaffolding system had performed. The applied weight is sum of the weights of the 15 workers, additional materials for coating work and dispersed and loaded shot ball on the foothold etc. the applied weight that calculated exceed more three times than the safe working load. Third, we had confirmed the install state of the materials of the scaffolding system by reviewing the quantity of the materials on the manual and the real system. Last, structural analysis had performed to evaluate structural integrity of the scaffolding system using Ansys. Through a series of this processes, the definite accidents causes of the collapsed scaffolding system revealed. Through these studies, the collapse accident that may occur in the scaffolding system in thermal power station can be minimized by performing specialized and systematic investigation on the accidents in terms of Forensic engineering.

Improvement in Safety Evaluation of Structures using the Bayesian Updating Approach (베이스 경신법을 활용한 구조물 안전성평가 개선)

  • Park, Kidong;Lee, Sangbok;Kim, Junki;Rha, Changsoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.2
    • /
    • pp.115-122
    • /
    • 2016
  • The classical statistical approach using test data samples to estimate true value of Random Variables by calculating mean and variation (standard deviation or coefficient of variation) of samples is very useful to understand the existing condition of the structure. But with this classical approach, our prior knowledge through educational background and professional experience cannot provide any benefit to make decisions by the structural engineers. This paper shows the role of Bayesian methodology by providing chance of using valuable prior knowledge to come up with more accurate estimation of structural condition. This paper also shows how important it is to have a proper prior estimate of Random Variables and corresponding confidence level through gathering and studying more relevant information.

Design Evaluation of WEDM Based on Deformation Analyses and Axiomatic Design (변형해석 및 공리적 설계에 의한 와이어 방전가공기의 설계평가)

  • Lee, Hyung-Yil;Woo, Sang-Woo;Kim, Joo-Won;Kim, Choong-Yeon
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.572-579
    • /
    • 2001
  • Recent industrial requirements for highly precise shape processing have brought the electric discharge machining (EDM) in great need. High precision in EDM is primarily achieved by high performance controllers. However there exists inherent precision loss due to structural deformation. On this background, we study structural deformation characteristics of wire cut EDM via finite element (FE) analysis and axiomatic design. Two different wire cut EDMs are selected as analysis models. 3D CAD package I-Deas is first used to construct FE models of wire cut EDMs, and then ABAQUS FE code is used for following structural analysis. Pertinency of FE mesh refinement is discussed in terms of ${\eta}-factor$. It is shown that performance accuracy of EDM depends strongly on the structural characteristics. Some design enhancements are suggested in an axiomatic design point of view. Finally we provide weight and temperature induced displacement discrepancies between wire end points as position functions of each subframe.

  • PDF