• Title/Summary/Keyword: structural evaluation

Search Result 4,836, Processing Time 0.035 seconds

An Experimental Study on the Thermal Properties of High Strength Concrete in the Range of $40{\sim}100MPa$ at High Temperature (고온시 $40{\sim}100MPa$ 범위의 콘크리트 열적특성에 관한 실험적 연구)

  • Kim, Heung-Youl;Jeon, Hyun-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.425-428
    • /
    • 2006
  • In order to estimate the reduction of laodbearing capacity, followed by the attributive change of heat while high strength concrete structure is revealed on fire it is necessary to evaluate, it is necessary to evaluate the property of material under high temperature such as thermal conductivity, specific heat, compressive strength, modulus of rigidity and diminution figure. Therefore, this study is for the purpose of presenting evaluation data for the analysis of thermal behavior about the high strength concrete material under high temperature, through the experiment by manufacturing concrete(40, 50, 60, 80, 100 MPa) commonly used in the construction field. As a result of the study, in the case of physical attribute, it demonstrates a greater fluctuation of change than the one of 30 MPa concrete. In case of specific heat, the high strength concrete, shown the serious diminution between $500{\sim}600^{\circ}C$, presents the thermal change area corresponding to the change of high strength concrete. In compressive strength, regardless of intensity of concrete, all of them show the first intensity loss between normal temperature and $100^{\circ}C$, the dramatic loss beyond $400^{\circ}C$. The concrete weighing above 50 MPa shows a twice lower dramatic intensity loss than the one weighing $30{\sim}40MPa$. The concrete ranging from $60{\sim}80MPa$, shows the biggest diminution of modulus of elasticity under $400^{\circ}C$, which implies the structural unstability of temperature.

  • PDF

A Evaluation on the Field Application of High Strength Concrete for CFT Column (고강도 CFT용 콘크리트의 현장적용성 평가 및 장기거동 예측)

  • Park, Je Young;Chung, Kyung Soo;Kim, Woo Jae;Lee, Jong In;Kim, Yong Min
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.6
    • /
    • pp.707-714
    • /
    • 2014
  • CFT (Concrete-Filled Tube) is a type of steel column comprised of steel tube and concrete. Steel tube holds concrete and the concrete inside tube takes charge of compressive load. This study presents structural performance of the CFT column which has 73~100 MPa high strength concrete inside. Fluidity, mechanical compression, pump pressure test in flexible pipe were conducted for understanding properties of the high strength concrete. Material properties were achieved by various experimental tests, such as slump, slump flow, air content, U-box, O-Lot, L-flow. In addition, mock-up tests were conducted to monitor concrete filling, hydration heat, compressive strength. From construction sites in Sang-am dong and University of Seo-kang, long-term behaviors could be effectively predicted in terms of ACI 209 material model considering elastic deformation, shrinkage and creep.

Estimation of Flexural and Shear Strength for Steel Fiber Reinforced Flexural Members without Shear Reinforcements (전단보강이 없는 강섬유보강 콘크리트 휨부재의 휨 및 전단강도의 평가)

  • Oh, Young-Hun;Kim, Jeong-Hae
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.2
    • /
    • pp.257-267
    • /
    • 2008
  • Results of seventy-seven specimens tested by this study and previous research were collected and evaluated to propose the flexural strength and shear strength for flexural members with steel fiber concrete. For strength evaluation, structural parameters such as compressive strength, steel fiber content, tensile reinforcement ratio, and shear span to effective depth ratio are involved. The proposed equations for flexural and shear strength are regarded to give a good prediction for the strength of steel fiber reinforced composite and/or RC beams to compare with equations by previous researchers. Especially, the proposed shear strength equation in this study shows the lowest the mean value, the coefficient of variation and the error ratio among predictions by several equations. Therefore, equations for shear strength and flexure strength, which are proposed in this study are to be useful measure to predict the actual behavior and failure mode of steel fiber reinforced composite beams.

Converged Influencing Factors on the Career Commitment of General Hospital Nurses with Preschool Children (미취학 자녀를 둔 종합병원 간호사의 경력몰입에 미치는 융합적 영향요인)

  • So, Ja-Young;Ha, Yun-Ju
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.5
    • /
    • pp.341-351
    • /
    • 2020
  • This study aimed to identify the parenting competence and parenting stress of nurses in general hospital with preschool children, and to identify convergent factors affecting career commitment. A cross-sectional design was used with a convenience sample of 214 nurses from seven general hospitals. Data were collected through self-evaluation questionnaires from August 10 to August 31, 2016 and analyzed using descriptive statistics, t-test, one-way ANOVA, Pearson's correlation coefficient, and structural modelling using the SPSS WIN 18.0 and AMOS 18.0 computer programs. Parenting stress had a full mediating effect on the influence of parenting competency on career commitment. It is expected to be used as a basic data for improving career commitment of nurses in general hospitals with preschool children, and further studies on factors affecting career commitment, including job-related characteristics, along with parenting-related factors, will be needed.

Performance Analysis of AOA Estimation for Concentric Ring Array Antenna in Beamforming Satellite System (빔형성 위성 시스템의 동심원 배열 안테나에 대한 도래각 추정 성능 분석)

  • Kim, Tae-Yun;Lee, Dongbin;Hwang, Suk-Seung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.4
    • /
    • pp.643-650
    • /
    • 2020
  • The phased array antenna has an advantage enabling rapid beam aim without the mechanical rotation of the antenna, because it arranges multiple elements in a linear or planer (grid or circular) and electronically controls the phase for each element. The planar array antenna is generally used a grid array and a circular array, and the circular form has the higher resolution comparing to the grid form due to the its structural characteristics. However, a concentric circular array (CCA) or a concentric ring array (CRA) with multiple circular arrays which each has different radius is used in the limited area, because the entire radius should be increased for the circular array with a number of elements. In this paper, we introduce the angle-of-arrival (AOA) estimator for an adaptive beamforming satellite system based on CRA and provide the simulation results for performance evaluation. In addition, simulation results are compared and analyzed to the case for the circular array antenna.

Acoustic Structure Interaction Analysis of the Core Support Barrel for Pump Pulsation Loads (펌프 맥동하중에 대한 노심지지배럴 집합체의 음향-구조 연성해석)

  • Lee, Jang Won;Moon, Jong Sung;Kim, Jung Gyu;Sung, Ki Kwang;Kim, Hyun Min
    • Transactions of the KSME C: Technology and Education
    • /
    • v.5 no.2
    • /
    • pp.127-134
    • /
    • 2017
  • The reactor internals shall be secured in safety and structural integrity under various vibrational loading conditions. Thus, U.S. NRC, Regulatory Guide 1.20 requires the evaluation for the reactor internals due to acoustic induced vibration including the response to the reactor coolant pump pressure pulsation. This paper suggests a methodology to develop an analytical model of the core support barrel accounting for the fluid around the structure and to analyze the responses to the pump pulsation loads using acoustic structure interaction analysis. The analysis results were compared with those of US Palo Verde 1 CVAP and showed a good agreement. Thus, it is expected that the suggested methodology could be an efficient way to evaluate the response of the core support barrel to the pump pulsation loads.

Optimal sensor placement for cable force monitoring using spatial correlation analysis and bond energy algorithm

  • Li, Shunlong;Dong, Jialin;Lu, Wei;Li, Hui;Xu, Wencheng;Jin, Yao
    • Smart Structures and Systems
    • /
    • v.20 no.6
    • /
    • pp.769-780
    • /
    • 2017
  • Cable force monitoring is an essential and critical part of the safety evaluation of cable-supported bridges. A reasonable cable force monitoring scheme, particularly, sensor placement related to accurate safety assessment and budget cost-saving becomes a major concern of bridge administrative authorities. This paper presents optimal sensor placement for cable force monitoring by selecting representative sensor positions, which consider the spatial correlativeness existing in the cable group. The limited sensors would be utilized for maximizing useful information from the monitored bridges. The maximum information coefficient (MIC), mutual information (MI) based kernel density estimation, as well as Pearson coefficients, were all employed to detect potential spatial correlation in the cable group. Compared with the Pearson coefficient and MIC, the mutual information is more suitable for identifying the association existing in cable group and thus, is selected to describe the spatial relevance in this study. Then, the bond energy algorithm, which collects clusters based on the relationship of surrounding elements, is used for the optimal placement of cable sensors. Several optimal placement strategies are discussed with different correlation thresholds for the cable group of Nanjing No.3 Yangtze River Bridge, verifying the effectiveness of the proposed method.

The Type Classification and Function Assessment at Small Palustrine Wetland in Rural Areas (농촌지역 소규모 소택형습지의 유형분류 및 기능평가 연구)

  • Son, Jin-Kwan;Kim, Nam-Choon;Kang, Bang-Hun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.13 no.6
    • /
    • pp.117-131
    • /
    • 2010
  • This study was conducted to utilize as basic information for the construction of conservation and estimation system for Palustrine wetland, which was badly managed and imprudently reclaimed, through the analysis of distribution characteristics and the estimation of conservation value for sample sites (eight wetlands) in rural area. As the result of wetland type classification, these wetlands was classified by 4 types (Permanent freshwater marshes/pools, ponds, Aquaculture ponds, and Seasonally flooded agricultural land) by Ramsar system, 3 types (Emergent Wetland, Aquatic Bed, and Scrub-Shrub Wetland) by NWI (Cowardin) System, 5 types (Farm Pond Depression, Under-flow wetland, Man-made Pond Depression, Abandoned Paddy Fields Wetland, and Reservoir Shore) by National Wetland's Categorical System, and 3 types (Aquatic Bed Wetland, Emergent Wetland, and Forested Wetland) by Lee (2000) System. These results suggest us developing the new type classification system for small Palustrine wetland in Korean rural areas. The score of function assessment (The Modified RAM) for small Palustrine wetlands was high at the wetlands nearby hills and rice paddy fields, and low at those nearby upper fields, which was mainly affected by land-use and vegetation. The functions as 'Flood/Storm Water Storage', 'Runoff Attenuation', 'Water Quality Protection' were resulted by the structural difference of inflow and outlet. Some functions as 'Wetland size', 'Wetland to immediate watershed ratio', 'Presence of boat traffic', 'Maximum water depth', 'Fetch of water's body' of RAM were not appropriate in evaluation of small wetlands in rural area. Which suggest us developing the new function assessment system for small Palustirne wetland in Korean rural areas.

An Analysis of the Discourse on the Length Concept in a Classroom for the Length of Space Curve (곡선의 길이 수업에서 길이 개념에 대한 담론 분석)

  • Oh, Taek-Keun
    • School Mathematics
    • /
    • v.19 no.3
    • /
    • pp.571-591
    • /
    • 2017
  • The purpose of this study is to understand the characteristics of mathematical discourse about the length in the class that learns the length of the curve defined by definite integral. For this purpose, this study examined the discourse about length by paying attention to the usage of the word 'length' in the class participants based on the communicative approach. As a result of the research, it was confirmed that the word 'length' is used in three usages - colloquial, operational, and structural usage - in the process of communicating with the discourse participants. Particularly, each participant did not recognize the difference even though they used different usage words, and this resulted in ineffective communication. This study emphasizes the fact that the difference in usage of words used by participants reduces the effectiveness of communication. However, if discourse participants pay attention to the differences of these usages and recognize that there are different discourses, this study suggests that meta - level learning can be possible by overcoming communication discontinuities and resolving conflicts.

A Numerical Study on Safety Evaluation of Prefabricated Sewage-Pipe Plastic Foundation Based on Pipe Diameters and Buried Soil Depths (하수관거 직경과 심도를 고려한 하수관거 플라스틱 받침기초의 안전성 평가를 위한 해석연구)

  • Park, Rae-Jin;Park, Jong-Sup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4322-4327
    • /
    • 2015
  • Improper backfill materials and compaction controls under pipelines have become one of the major causes of failure in many sewage pipeline systems. A study on backfill materials and compaction controls has been considered for a long time. However, structural supporters under the pipe were recently concerned because of pipeline repair and maintenance. This paper presents a prefabricated plastic foundation for supporting a sewage pipe system and increasing the performance function of the pipes. Several analytical models for the plastic foundations were investigated using finite-element program, ABAQUS, for checking safety. Comparing with the results of analyses, some of economic design sections based on the sizes of pipe diameters, 600mm, 700 and 600mm, were evaluated. These results could be applied to a pipeline system with a prefabricated plastic foundation with respect to pipe diameters and buried depths.