• Title/Summary/Keyword: structural evaluation

Search Result 4,836, Processing Time 0.035 seconds

Characteristics Evaluation of Radiation Shielding Materials Used Waste Glass and Chelate Resins (폐유리와 킬레이트 수지를 사용한 방사선 차폐재의 재료특성 평가)

  • Kim, Hyo-Jung;Jang, Jong-Min;Song, Young-Soon;Noh, Jae-Ho;Yi, Seong-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.3
    • /
    • pp.56-64
    • /
    • 2019
  • Various approaches have been attempted to develop recycling technologies related to industrial waste resources containing metals. Among them, glass is not decomposed into microorganisms, so landfill is not suitable, and interest in the recycling of waste glass is increasing. In this paper, by incorporating chelate resin to suppress the elution of heavy metals in waste glass and using waste glass as a fine aggregate and we want to evaluate the strength, drying shrinkage, alkali-silica reaction and heavy metal leaching of shielded filler materials and to provide basic data for utilizing waste glass as an economical and environmentally friendly shielding filler. As a result of the test, it was found that the use of waste glass as a fine aggregate was effective in the development of strength, but the incorporation of chelate resin had an influence on the strength development. In addition, the addition of chelate resin was effective in improving drying shrinkage but it was found to affect the alkali - silica reaction. As a result of the heavy metal leaching test, the KSLP test method satisfies all the criteria for heavy metal leaching. However, in case of lead, the limit of US ANSI 67-2007a was exceeded and further study should be done.

Seismic Behavior Evaluation of Embedded Kagome Damping Device (콘크리트에 매립된 카고메 감쇠시스템의 내진거동평가)

  • Hur, Moo-Won;Lee, Sang-Hyun;Kim, Jong-Ho;Hwang, Jae-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.2
    • /
    • pp.84-91
    • /
    • 2019
  • Recently, there has been a tendency to improve seismic performance of building structure by installing a steel hysteretic damping device which is economically efficient and easy to install and maintain. However, for a reinforced concrete building, a set of complicated connecting hardware and braces to fix the steel hysteretic damping device yields deteriorated reliability in damping performance. Therefore, this study presents a method of directly embedding a Kagome damper, which was investigated in previous researches, into a concrete structure without additional connecting hardware. Moreover, in this study, a series of experiments conducted to provide a basis of the Kagome damper by confirming the seismic behavior for various embedded lengths. As a result, in a group of the embedded length of $1.0l_d$, the dampers were pulled out, while concrete breakout occurs. In a group of $2.0l_d$, neither pull-out nor concrete breakout occurred, while the dampers show stable behavior. Moreover, the buried length of $2.0l_d$ has 1.3 times better energy dissipation capacity. The system presented in this study can reduce the cost and period for installing, omitting making additional hardware.

Evaluation for Long Term Drying Shrinkage and Resistance to Freezing and Thawing of Hybrid Fiber Reinforced Concrete (하이브리드 섬유보강 콘크리트의 장기 건조수축 및 내동해성 평가)

  • Kim, Yo-Seb;Bae, Su-Ho;Lee, Hyun-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.2
    • /
    • pp.60-66
    • /
    • 2019
  • Many researches have been performed on hybrid fiber reinforced concrete for years, which is to improve some of the weak material properties of concrete. Researches on characteristics of hybrid fiber reinforced concrete using amorphous steel fiber and organic fiber, however, yet remain to be done. Therefore, the purpose of this research is to estimate the compressive strength, long term drying shrinkage, and resistance to freezing and thawing of hybrid fiber reinforced concrete(HFRC) using amorphous steel fiber and polyamide fiber as one of organic fibers. For this purpose, HFRCs containing amorphous steel fiber and polyamide fiber were made according to their total volume fraction of 1.0% for target compressive strength of 40 and 60 MPa, respectively, and then the compressive strength, length change, and resistance to freezing and thawing of these were evaluated. As a result, the long term length change ratio of HFRC used in this study decreased by more than 30%, 25% than plain concrete at 365 and 730 days, respectively, and the durability factor of HFRC was very excellent as more than 90%.

Evaluation of Ozone Resistance and Anti-Corrosion Performance of Water Treatment Concrete according to Types of Metal Spray Coating (수처리시설용 콘크리트의 금속용사 피막 종류에 따른 내오존성 및 전기화학적 방식 성능 평가)

  • Park, Jin-Ho;Choi, Hyun-Jun;Lee, Han-Seung;Kim, Sang-yeol;Jang, Hyun-O
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.61-68
    • /
    • 2019
  • As the pollution of water resources deteriorates due to industrialization and urbanization, it is difficult to supply clean water through a water treatment method using chlorine. Therefore, the introduction of advanced water treatment facilities using ozone is on the increase. However, epoxy which is used as waterproofing and anticorrosives and stainless steel used in conventional waterproofing and anti-corrosive methods have deteriorated because of the strong oxidizing power of ozone, causing problems such as leaking. Moreover, it even causes the durability degradation of a concrete. Therefore, in this study, metal spraying system was used as the means of constructing a metal panel with excellent ozone resistance and chemical resistance which is an easier method than an existing construction method. Ozone resistance was evaluated in accordance with the type of metal sprayed coatings to develop a finishing method which can prevent the concrete structure of water treatment facilities from deterioration. Furthermore, electrochemical stability in actual sewage treatment plant environment was evaluated. Experimental results showed that Ti has superior ozone resistance after spraying and the electrochemical stability in the sewage treatment plant environment showed that Ti has the highest polarization resistance of $403.83k{\cdot}{\Omega}{\cdot}cm^2$, which ensures high levels of durability.

Evaluation of Durability Performance in Concrete Incorporating Low Fineness of GGBFS (3000 Grade) (저분말도 고로슬래그 미분말(3000급)을 혼입한 콘크리트의 내구성능평가)

  • Lee, Seung-Heun;Cho, Sung-Jun;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.96-102
    • /
    • 2019
  • When GGBFS(Ground Granulated Blast Furnace Slag) with high blaine is incorporated in concrete, compressive strength in the initial period is improved, but several engineering problems arise such as heat of hydration and quality control. In this paper, compressive strength and durability performance of concrete with 3,000 Grade-low fineness slag are evaluated. Three conditions of concrete mixtures are considered considering workability, and the related durability tests are performed. Although the strength of concrete with 3,000 Grade slag is slightly lower than the OPC(Ordinary Portland Cement) concrete at the age of 28 days, but insignificant difference is observed in long-term compressive strength due to latent hydration activity. The durability performances in concrete with low fineness slag show that the resistances to carbonation and freezing/thawing action are slightly higher than those of concrete with high fineness slag, since reduced unit water content is considered in 3,000 Grade slag mixture. For the long-term age, the chloride diffusion coefficient of the 3000-grade slag mixture is reduced to 20% compared to the OPC mixture, and the excellent chloride resistance are evaluated. Compared with concrete with OPC and high fineness GGBFS, concrete with lower fineness GGBFS can keep reasonable workability and durability performance with reduced water content.

Carbonation Behavior Evaluation of OPC Concrete Considering Effect of Aging and Loading Conditions (재령 및 하중효과를 고려한 OPC 콘크리트의 탄산화 거동 평가)

  • Hwang, Sang-Hyeon;Yoon, Yong-Sik;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.122-129
    • /
    • 2019
  • The movement of deterioration agents such as a chloride ion, etc. in concrete varies with loading conditions and micro-structure developed by age effect. In this paper, the carbonation behavior by accelerated carbonation test is evaluated considering curing periods(28 days, 91 days, and 365 days) and loading conditions. Carbonation velocity coefficients are obtained referred to KS F 2584. In the control case without loading condition, carbonation velocity coefficient of 91 days decreases to 50.0 % level and that of 365 days decreases to 44.8 % level than that of 28 days curing condition. In 28 curing days, carbonation velocity coefficients changed level of 103.9 ~ 108.8 % in tensile region and 91.9~104.6 % in compressive region by loading conditions. Carbonation velocity coefficients in the 30 % and 60 % tensile loading case at 28 days decreases to 47.3 % and 52.5 % level compared to control case after 1 year. Furthermore, 45.8 % and 44.9 % level of carbonation velocity coefficients are evaluated for 30 % and 60 % compressive loading conditions compared to control case after 1 year. Carbonation velocity coefficient decreases in the 30 % compressive loading level due to effective pore compaction and it increases afterwards due to micro-cracking. In the tensile loading condition, unlike the behavior of compressive region, it linearly increases with increasing loading level.

Evaluation of the Pull-out Resistance of the SMA Wire Connector (SMA 와이어를 이용한 연결재의 인발저항성능 평가)

  • Jung, Chi-Young;Woo, Tae-Ryeon;Lee, Jong-Han;Cheung, Jin-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.130-137
    • /
    • 2019
  • Precast concrete (PC) structure is one of the type of the structures which is made in a facility prior to installing it to a construction field. The contact surfaces between two PC structures should be treated for obtaining enough binding force by inducing prestressing force. However, in the many cases, the contact surface causes the crack and leakage of water. These cracks and water leakage can cause the corrosion of the rebar, and the corrosion of the rebar can severely reduce the long-term durability. In this study, the SMA wire connector is suggested to solve the problem with the contact surfaces between two PC structures. The pull-out resistance of the suggested SMA wire connector is evaluated by conducting the tests to find the effect of the number of wires, shape of connector part, and shape memory effect. As a result of this study, the empirical formula is suggested to estimate the pull-out resistance related with the effects of the shape of the connector, shape memory effect, and the adhesive force. The validity between the estimated pull-out resistance and the measured value is confirmed.

A Study on Development of Measurement Tools for Word-of-Mouth Constraint Factors - Focusing on SNS Advertising - (구전 제약요인 측정도구 개발에 대한 연구 - SNS 광고를 중심으로 -)

  • Yun, Dae-Hong
    • Management & Information Systems Review
    • /
    • v.38 no.2
    • /
    • pp.209-223
    • /
    • 2019
  • The purpose of this study was to stimulate the online word-of-mouth advertising by developing the concept of word-of-mouth constraint factors and measurement tools in connection with the SNS advertising on social networks. To achieve the objective of this study, this study was conducted in 3 phases. First, the exploratory investigation(target group interview, in-depth interview, and expert interview) was performed to determine the concept and scope of the word-of-mouth constraint based on literature study and qualitative investigation method. Second, the reliability and validity of the measurement questions were verified through the survey in order to refine the developed measurement items. Third, the predictive validity of measurement items was verified by examining the relationship with other major construct concept for which the developed measurement items were different. Based on the results of study, 6 components and a total of 23 measurement questions for those components were derived. Each was called intrapersonal and interpersonal constraint(psychological sensitivity, compensatory sensitivity, and other person assessment), structural constraint(reliability, informativity, and entertainment). We developed the measurement questions related to word-of-mouth constraint based on qualitative study and quantitative study and holistically examined the social and psychological, environmental interruption factors acting as the word-of-mouth constraint factors for SNS advertising in terms of SNS achievements and evaluation from the perspective of word-of-mouth constraint. The results will lead to creation of basic framework for systematic and empirical research on the online word-of-mouth constraint and to achievement of effective SNS word-of-mouth advertising.

Structural Disorganization of Intestinal Tumor Spheroid by Microbial Ribotoxins (방사선 모사 미생물 유래 리보솜 스트레스에 의한 대장암 스페로이드 구조 결함 유발)

  • Kim, Juil;Kim, Joongkon;Yu, Mira;Moon, Yuseok
    • Microbiology and Biotechnology Letters
    • /
    • v.47 no.1
    • /
    • pp.164-171
    • /
    • 2019
  • Radiation therapy has many side effects, such as digestive mucosal ulcers, without regard to its efficacy. The purpose of this study is to address an alternative method to replace the limitation of radiation therapy using radiomimetic microbial ribotoxins. In the evaluation of cancer therapy, we analyzed the formation of colorectal cancer (CRC) cell spheroids, which can take into account the heterogeneous cellular constitution, tumor stem cells, and the surrounding microenvironment. Ribotoxic stress interfered with the spheroid structure composed of relatively small clusters. Spheroids under ribotoxic stress were structurally sparse and their shrinkage was very slow. In the control group, the clusters of strongly aggregated cells were resistant to physical stress, but the ribotoxic stress-exposed spheroids were easily broken up by the physical stress. Moreover, the ribosome-insulted CRC cells slowly migrated to form clusters and the cell-cell junctional points in the ribosome-insulted spheroids were rarer than those in the control CRC spheroid. Moreover, levels of the cell-to-cell junctional protein E-cadherin were suppressed by ribotoxic stress in both allograft and xenograft spheroids. In conclusion, the radiomimetic microbial ribotoxins induced structural defects in CRC cell spheroids via retardation of migration and cell-cell junction in the formation of three-dimensional structures, and provides a basis for the mechanism of pharmacological radiomimetic anticancer actions as an alternate to radiotherapy against cancer.

Seismic Performance Evaluation of Concrete Anchors used in Power Plant Equipment by Shaking Table Tests (진동대 실험을 통한 발전기기용 콘크리트 앵커의 성능평가)

  • Lee, Sang-Moon;Jeon, Bub-Gyu;Jung, Woo-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.1
    • /
    • pp.21-28
    • /
    • 2021
  • The main purpose of this study is to assess the safety of the fixed anchorages subjected to the seismic motion for an operating facilities in the actual power plant. Thus, the experimental study was conducted to investigate the load response in the event of an actual seismic to the anchorages of a nonstructural components. Since there are economic and spatial constraints to study nonstructural components that actually have various forms, alternative test specimens of steel frames with mass were built and the shaking table test was carried out. In order to evaluate the dynamic characteristics and seismic performance, the natural frequency of the target structure was identified through the shaking table test and then the load response characteristics of the anchorage were evaluated by generating an artificial seismic effect like actual seismic. Finally, the structural stiffness was reinforced by fixing the steel frame to the test specimen using bolts, thereby reducing the load transmitted to the anchorage. It will be carried out on the reliability verification of the experiments and areas that have not been carried out due to the site conditions through the analytical approach in the future.