Seismic Perfomance Evaluation of Wind-Designed Steel Highrise Buildings Based on Linear Dynamic Analysis (내풍설계된 철골조 초고층건물의 선형동적해석에 의한 내진성능평가)

  • Lee, Cheol-Ho;Kim, Seon-Woong
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.177-184
    • /
    • 2005
  • Even in moderate to low seismic regions like Korean peninsular where wind loading usually governs the structural design of a tall building, the probable structural impact of the design basis earthquake or the maximum credible earthquake on the selected structural system should be considered at least in finalizing the design. In this study, by using response spectrum analysis and time history analysis method, seismic performance evaluation was conducted for wind-designed concentrically braced steel highrise buildings. Input ensemble was normalized to be compatible with expected peak ground acceleration. The analysis results showed that wind-designed concentrically braced steel highrise buildings possess significantly increased elastic seismic capacity due to the system overstrength resulting from the wind-serviceability criterion and the width-to-thickness ratio limits on steel members. The time history analysis tended to significantly underestimated the seismic response as compared to response spectrum analysis. Further detailed studies regarding selection and scaling scheme of input ground motions is needed.

  • PDF

Structural Integrity Evaluation of 10,000 Ton Brake Bending Press (10,000 Ton Brake Bending Press 구조 건전성에 관한 평가)

  • Park, Jung-Won;Lee, Hyun-Min;Ku, Tae-Wan;Kim, Jeong;Kang, Beom-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.529-533
    • /
    • 2008
  • Thick pipes have been used in fields of ocean and industrial plants, and pipe arrangement of oil and water pipelines. Mostly, roll bending process has been used in manufacture of the pipes. Recently, however, studies on the pipe forming processes using brake press have been performed. Normally, the brake press has high aspect ratio, so structural integrity evaluation should be conducted. In this study, finite element analysis of structural integrity for the brake bending press was carried out for thick pipe forming process.

  • PDF

Studies on the Evaluation Method of Strength Comparison for Application in Joint Separation Test Body to Structural Concrete (구조체 콘크리트에 접합분리 시험체의 적용을 위한 강도비교에 관한 실험적 연구)

  • Kim, Seong-Deok;Lee, Seon-Ho;Jung, Kwang-sik;Paik, Min-su;Lee, Young-Do;Jung, Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.79-82
    • /
    • 2008
  • It has been reported that destruction test by core collection is the most reliable of the structural concrete strength in present building construction field. But it causes low efficiency by damage and cutting in structure due to the core collection. It also has some problems in repairing. Additionally in case of strength test with management specimen, different environment compared to the structure environment cause problems about estimation precise structure strength. Therefore, it is required to develop structure direct strength test that has test values and credibility above the ones obtained by core specimen collection strength test and seasonal specimen test to suggest a reasonable and practical management method of structural concrete.

  • PDF

Reliability Test and Evaluation of Air Spring for Railway Vehicle (철도차량용 공기스프링 신뢰성 시험 및 평가)

  • Woo Changsu;Kim Wandoo;Lee Hakjoo;Jeong Sungil
    • Journal of Applied Reliability
    • /
    • v.5 no.1
    • /
    • pp.149-165
    • /
    • 2005
  • Air spring system was accepted for railway vehicle secondary suspension to reduce and absorb the vibration and noise. The low natural frequency ensures a comfortable ride and an invariably good stiffness. In this paper, the characteristics and durability test was conducted in laboratory by using servo-hydraulic fatigue testing system to reliability evaluation of air spring for electric railway vehicle. The experimental results show that the characteristics and durability of domestic development productions are obtained the good results. And to guarantee the adaption of air spring, the ride comfort and air pressure variation were measured in train test on subway line.

  • PDF

Evaluation of accidental eccentricity for buildings by artificial neural networks

  • Badaoui, M.;Chateauneuf, A.;Fournely, E.;Bourahla, N.;Bensaibi, M.
    • Structural Engineering and Mechanics
    • /
    • v.41 no.4
    • /
    • pp.527-538
    • /
    • 2012
  • In seismic analyses of structures, additional eccentricity is introduced to take account for oscillations of random and unknown origins. In many codes of practice, the torsion about the vertical axis is considered through empirical accidental eccentricity formulation. Due to the random nature of structural systems, it is very difficult to evaluate the accidental eccentricity in a deterministic way and to specify its effect on the overall seismic response of structures. The aim of this study is to develop a procedure for the evaluation of the accidental eccentricity induced by uncertainties in stiffness and mass of structural members, using the neural network techniques coupled with Monte Carlo simulations. This method gives very interesting results for single story structures. For real structures, this method can be used as a tool to determine the accidental eccentricity in the seismic vulnerability studies of buildings.

Evaluation of the Equivalent First Modal Damping Ratio of a Structure with Additional Damping Devices (부가감쇠 장치가 설치된 구조물의 1차 모드 등가 감쇠비 산정)

  • Lee, Sang-Hyun;Min, Kyung-Won;Hwang, Jae-Seung;Lee, Young-Cheol
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.459-466
    • /
    • 2002
  • The purpose of this study is to propose a new method for evaluating equivalent damping ratios of a structure with supplemental damping devices to assess their control effect quantitatively. A MDOF system is transformed to an equivalent SDOF system based on the assumption that the first mode dominates structural response. Approximate closed-form formulas for the evaluation of the first damping ratio are presented for various damping devices. Through numerical analysis of a ten-story building equipped with damping devices, the effectiveness of equivalent SDOF model and closed form formulas are verified.

  • PDF

Evaluation of Organization and Use of Data Model for Structural Experiment Information (구조실험정보를 위한 데이터 모델의 구성 및 사용성 평가)

  • Lee, Chang-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.6
    • /
    • pp.579-588
    • /
    • 2015
  • The data model for structural experiment information formally organizes the information involved in the structural experiments before the data repository using the data model is implemented. The data model is particularly required for the data repositories for the large-scale structural experiment information and the general information for various types of experiments, such as the NEEShub Project Warehouse developed by NEES. This paper proposes criteria for evaluating the organization and the use of design model for structural experiment information. The term of AVE(attribute value existence) indicates the ratio of attributes who values exist in objects, and then used for defining the Attribute AVE for the use of an attribute, the Class AVE for a class, the Class Level AVE for a class including its lower-level classes, the Project AVE for a project including all classes at class levels, and the Data Model AVE for a data model including projects. These criteria are applied to the projects in the NEES data model, and it is successively possible to numerically describe the evaluation of the use of classes and attributes in the data model.

A Method for Selecting a Structural Optimal Flood Mitigation Plan Using Analytic Hierarchy Process (계층화분석기법을 통한 구조물적 홍수방어 최적대안 선정 방안 연구)

  • Lee, Jeong-Ho;Jun, Young-Joon;Ahn, Jae-Hyun;Kim, Tae-Woong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.3
    • /
    • pp.117-126
    • /
    • 2009
  • Various dimensions of watershed structural/non-structural planning can be applied in comprehensive flood mitigation plan in a river basin. Especially structural counterplans have very broad and diverse nature as flood control facilities. It is not easy to find the optimum alternative to maximize the ability of a basin to reduce flood risk using a combination of structural counterplans. In addition, there is no standard for evaluating the performance of structural counterplans and for selecting optimal combination of them. This study focused on how to select the best alternative of a comprehensive watershed structural plan from various flood defense alternative candidates. By introducing an analytic hierarchy process, we would like to show how we decide the best alternative using standard worksheets developed in this study for economics and policy evaluation, and Expert Choice 11.5, which calculates weights for evaluation items. Based on the results from this study, we would like to suggest the best practice of a standardized watershed plan for flood protection.

Evaluation of Ground Motion Modification Methodologies for Seismic Structural Damage (지진 구조 손상도 예측을 위한 지반 운동 수정법 평가)

  • Heo, YeongAe
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.112-118
    • /
    • 2013
  • The selection of appropriate ground motions and reasonable modification are becoming increasingly critical in reliable prediction on seismic performance of structures. A widely used amplitude scaling approach is not sufficient for robust structural evaluation considering a site specific seismic hazard because only one spectral value is matched to the design spectrum typically at the structural fundamental period. Hence alternative approaches for ground motion selection and modifications have been suggested. However, there is no means to evaluate such methodologies yet. In this study, it is focused to describe the main questions resided in the amplitude scaling approach and to propose a regression model for structural damage as point of comparison. Spectrum compatible approach whose resulting spectrum matches the design spectrum at the entire range of the structural period is considered as alternative to be compared to the amplitude scaling approach. The design spectrum is generated according to ASCE7-05.

Real-time large-scale hybrid testing for seismic performance evaluation of smart structures

  • Mercan, Oya;Ricles, James;Sause, Richard;Marullo, Thomas
    • Smart Structures and Systems
    • /
    • v.4 no.5
    • /
    • pp.667-684
    • /
    • 2008
  • Numerous devices exist for reducing or eliminating seismic damage to structures. These include passive dampers, semi-active dampers, and active control devices. The performance of structural systems with these devices has often been evaluated using numerical simulations. Experiments on structural systems with these devices, particularly at large-scale, are lacking. This paper describes a real-time hybrid testing facility that has been developed at the Lehigh University NEES Equipment Site. The facility enables real-time large-scale experiments to be performed on structural systems with rate-dependent devices, thereby permitting a more complete evaluation of the seismic performance of the devices and their effectiveness in seismic hazard reduction. The hardware and integrated control architecture for hybrid testing developed at the facility are presented. An application involving the use of passive elastomeric dampers in a three story moment resisting frame subjected to earthquake ground motions is presented. The experiment focused on a test structure consisting of the damper and diagonal bracing, which was coupled to a nonlinear analytical model of the remaining part of the structure (i.e., the moment resisting frame). A tracking indictor is used to track the actuator ability to achieve the command displacement during a test, enabling the quality of the test results to be assessed. An extension of the testbed to the real-time hybrid testing of smart structures with semi-active dampers is described.