• Title/Summary/Keyword: structural evaluation

Search Result 4,836, Processing Time 0.03 seconds

Performance Evaluation of a Nonlinear Cable Damper for Stay Cables Using Wind Vibration Analysis (사장교 케이블의 풍진동 해석을 통한 비선형 댐퍼의 성능 검증)

  • Kim, Saang-Bum;Lee, Sung-Jin
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.603-606
    • /
    • 2007
  • Wind induced vibration of a stay cable with a nonlinear friction damper is investigated. Stay cables are likely to vibrate under several wind-related environments, and cable dampers can be used to suppress the excessive vibrations of stay cables. Conventional design of cable dampers are based on the equivalent modal damping achieved by the cable damper. However, the equivalent modal damping achieved by nonlinear dampers are depend on the vibration characteristics like the amplitude of the vibration. In this paper, not only the achieved equivalent modal damping, but also the vibration levels under gust wind are analyzed through the time domain buffeting analysis. Numerical simulation results show the efficacy of a nonlinear friction damper for suppressing the excessive vibration of a stay cable.

  • PDF

The evaluation of applicability of spectral element method for the dynamic analysis of the spatial structures (대공간 구조 시스템의 동적 해석을 위한 스펙트럴 요소법의 적용성 평가)

  • Han, Sang-Eul;Lee, Sang-Ju;Cho, Jun-Yeong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.789-794
    • /
    • 2007
  • Recently, the necessity of efficient and exact method to analyze structures is increasing with the importance of the seismic analysis. But the finite element method used in many field do not give the exact solution unless the length of the element is very short enough to represent the deformation of the element. Because the amount of computer calculation increase with the increasing of the number of degree of freedoms, the finite element method for the exact dynamic analysis of structures would not be efficient. To solve these problems, spectral clement method combined spectral method using the principle of wave mechanics and finite element method for the analysis of discrete models is applied to evaluate the behavior of the spatial structures. As a result of analysis. it becomes clear that the spectral element method is faster and more exact than the finite clement method.

  • PDF

Evaluation of Effective Length Factor by Using an Amplification Factor (확장계수를 적응한 기둥의 유효좌굴길이 계수 산정)

  • Choi, Dong-Ho;Yoo, Hoon;Shin, Jay-In;Kim, Sung-Yeon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.369-374
    • /
    • 2007
  • For a stability design of steel frames, AISC-LRFD specification recommend to use Alignment Chart and story-based methods in order to determine an effective budding length. Recently, elastic buckling analysis, which is the method that calculate the effective length of members using eigenvalue of the overall structure, has been widely used in practical design of steel frames because this method can be performed effectively and automatically by computers. However, it can in some cases lead to unexpectedly large effective length in column having small axial forces. Therefore, this paper propose a method using elastic buckling analysis, which estimate a proper effective buckling length for all members having a small axial force. For verification of proposed method, it is compared with system based approach and stiffness distribution factor method. As a result, proposed method can rationally solve a problem in some case of column having small axial force. Also, adoption range for proposed method is established.

  • PDF

Nonlinear analysis of PSC bridge with strengthened of externally tendon Considering Construction Sequences (외부강선으로 보강된 PSC 교량의 시공단계별 비선형 해석)

  • Park, Jae-Guen;Lee, Byeong-Ju;Kim, Moon-Young;Shin, Hyun-Mock
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.283-288
    • /
    • 2007
  • This paper presents an analytical prediction of Nonlinear characteristics of prestressed concrete bridges by strengthened of externally tendon considering the work sequence, using beam-column element based on flexibility method and tendon element. The beam-column element was developed with reinforced concrete material nonlinearities which are based on the smeared crack concept. The fiber hysteresis rule of beam-column element is derived from the uniaxial constitutive relations of concrete and reinforcing steel fibers. The tendon element represent the bonded tendon and unbonded tendon behaviors. Beam-column element and tendon element was be subroutine A computer program, named RCAHEST (Reinforced Concrete Analysis in Higher Evaluation System Technology), for the analysis of RC and PSC structures was used. The proposed numerical method for prestressed concrete structures by strengthened of externally tendon is verified by comparison with reliable experimental results.

  • PDF

Seismic Risk Evaluation of Isolated Emergency Diesel Generator System (면진된 비상디젤발전기의 지진위험도 평가)

  • Kim, Min-Kyu;Ohtori, Yasuki;Choun, Young-Sun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.217-222
    • /
    • 2007
  • An Emergency Diesel Generator (EDG) is one of the safety related equipments of a Nuclear Power Plant. The seismic capacity of an EDG in nuclear power plants influences the seismic safety of the plants significantly. A recent study showed that the increase of the seismic capacity of the EDG could reduce the core damage frequency (CDF) remarkably. It is known that the major failure mode of the EDG is a concrete coning failure due to a pulling out of the anchor bolts. The use of base isolators instead of anchor bolts can increase the seismic capacity of the EDG without any major problems. This study introduces a seismic risk analysis method and presents sample results about the seismically isolated and conventional EDG system.

  • PDF

Prediction Formulas for Nondestructive Strength of Quartzite Aggregate Concrete (규암 골재를 사용한 콘크리트 구조물의 재령에 따른 비파괴강도 추정식)

  • Oh, Byung-Hwan;Kim, Dong-Wook;Lee, Seung-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.2
    • /
    • pp.137-146
    • /
    • 2001
  • The non-destructive tests are widely used to predict the strength of existing structures. The purpose of the present study is to propose the prediction equations for strength evaluation of concrete structures. The present study focuses on the rebound method and ultrasonic pulse velocity method for quartzite aggregate concrete. The major test variables include the water-cement ratio and curing methods. The water-cement ratio are 0.4, 0.5, 0.6, 0.7, respectively and the curing method covers ail-dry condition and standard curing condition. The prediction equations for strength of concrete are proposed from the present test data.

  • PDF

Evaluation of Serviceability due to Vibration of Slab (건축구조물의 슬래브 진동에 의한 사용성 평가 연구)

  • Woo, Woon-Taek;Park, Tae-Won;Chung, Lan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.4
    • /
    • pp.225-230
    • /
    • 2000
  • Recent building structures are superior in its ability but they are light and flexible, and so have problems of vibration. In general, the serviceability of RC slabs was known to be good against vibration because of its hardness. However, recent high-rise apartment slabs are mostly light and long, the serviceability of RC slabs due to vibration could be a problem. In this paper, a basic investigation about vibration problems of RC slabs was performed. Basic information and its influence on vibrations of RC slabs were revealed. Also, its serviceability against vibration was examined. Many tests were conducted on existing building located in Chung-Nam area. As a results, damping ratio, natural frequency, acceleration amplitude and displacement amplitude which were used to examine serviceability of the RC slabs were obtained. These results on the test building proved that its serviceability conditions were satisfied to meet the code against vibration.

  • PDF

Condition Evaluation of Concrete Bridge Decks using CPR (레이더를 이용한 콘크리트 교량의 바닥판 상태평가)

  • Suh, Jin-Won;Rhee, Ji-Young;Lee, Il-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.4
    • /
    • pp.101-107
    • /
    • 2000
  • In this study, the Ground Penetrating Radar(GPR) was tested to evaluate the condition of concrete decks. Test results obtained by CPR were compared with values measured from drilled cores and damage mapping by the visual survey. It is shown that GPR can provide highly accurate measurements of layer properties of concrete decks and can map areas of deterioration in bridge decks by dielectric constants. The deck condition can be grouped into categories of "good" or "distressed". The ground penetrating radar data shows promise for producing rapid and accurate condition assessment for bridge decks. And these data can be used to evaluate highway bridge condition and make cost-effective bridge deck rehabilitation by accurately estimating the quantity of deteriorated concrete.

  • PDF

Study on Noise Reduction of DLP Front Home Theater Projector (가정용 DLP 프로젝터의 소음 저감에 관한 연구)

  • Jang Dong Seob;Park Chul Min;Park Dae Kyong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.9 s.90
    • /
    • pp.861-867
    • /
    • 2004
  • For the evaluation of acoustic noise of a DLP projector, vibration and sound characteristics of a DLP projector were studied. The acoustic noise of DLP projector could be classified into three categories, that is, the direct noise from a body of rotation, the air-bone noise generated from turbulence or vortex occurred during cooling process and the structural born noise produced by vibrating elements. Cooling fans and color filter wheel which rotates at 9000 rpm are main causes of acoustic noise induced in DLP projector. Since the structure of an optical module in a DLP projector can be excited by the excessive vibration of a color filter wheel, the structural design for anti-vibration should be considered. To make a reduction of overall acoustic noise, the anti-vibration design and the enclosing structure have been studied and applied to a color filter wheel.

Recognition of Pharmacophore of ar-Turmerone for its Anticancer Activity

  • Baik, Kyong-Up;Jung, Sang-Hun;Ahn, Byung-Zun
    • Archives of Pharmacal Research
    • /
    • v.16 no.3
    • /
    • pp.254-256
    • /
    • 1993
  • For the evaluation of the role of .alpha., .betha.-unsaturated ketone portion of ar-tumerone for its activity, the structural variation of this structural unit was performed to omit its alkylating propery. Thus compounds 2, 3, and 4 were prepared and their cytotoxicities were determined against three different leukemiz cell lines (HL-60, K-562, and $L_{1210})$ in vitro. The biological inactivity against three different cell lines of these analogues implies that the $\alpha, \beta$-unsaturated ketone of ar-tumerone is the essential pharmacophore for its activity.

  • PDF