• Title/Summary/Keyword: structural evaluation

Search Result 4,836, Processing Time 0.027 seconds

Structural Capacity Evaluation of High Strength Concrete Short Columns with Various Design Parameters under High Temperatures (고온하에서 다양한 설계변수에 따른 고강도 콘크리트 단주의 구조 성능 평가)

  • Kim, Hee-Sun;Mun, Ji-Young;Park, Jee-Eun;Shin, Yeong-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.5
    • /
    • pp.637-645
    • /
    • 2011
  • It is well known that high strength concrete with compressive strength higher than 50 MPa shows severe material and structural damages under fire due to spalling. To understand degradation of structural capacity of fire damaged high strength concrete structures, not only thermo-mechanical behavior needs to be defined, but also structural behavior of high strength concrete member under high temperature needs to be investigated. In this study, structural tests are performed by applying axial loads on high strength concrete columns exposed at elevated temperatures for assigned amount of time. The tested columns are prepared to have different concrete strength and polypropylene fiber percentage. The test results show that structural capacity of the columns decreased with increased compressive strength of concrete under same heating condition. Especially, it is interesting to note that high strength concrete columns with polypropylene fiber for spalling proof did not improve structural capacity compared to the columns without polypropylene fiber. The findings from the test are able to improve fire proof design of high strength concrete structural members and predicting structural performance of fire damaged structural members.

A Study on the Static Structural Strength Evaluation of 53ft Liquefied Natural Gas Tank Container (53ft 액화천연가스 탱크 컨테이너의 정적 구조 강도 평가에 관한 연구)

  • Chunsik Shim;Hokyung Kim;Daseul Jeong;Deokyeon Lee;Kangho Kim;Minsuk Kim;Sungkuk Wi;Heechang Noh;Youngbin Kwon;Changseok Hong;Kim Byeonghwa;Cheonghak Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.4
    • /
    • pp.278-287
    • /
    • 2023
  • This study aims to analyze and evaluate the structural strength of a 53ft Liquefied Natural Gas (LNG) tank container according to International Organization for Standardization (ISO) 1496-3, amidst growing global demand for LNG transportation. The research was conducted in two main stages: structural analysis using Finite Element Analysis (FEA) under various load conditions, and structural strength tests following ISO 1496-3 test procedures. The structural analysis was performed considering different loading conditions to assess the structural safety of the tank container. Calculated stresses were compared with allowable stress under specified load conditions. The structural strength tests were conducted at Mokpo National University's Subsea Umbilical cable Riser Flowline R&D Center, which provided a suitable testing environment. The study found that calculated stresses met the allowable stress under specified load conditions, confirming the structural safety of the tank container. Additionally, the maximum deformation and permanent deformation satisfied the design criteria for all test cases, indicating the container's structural strength meets requirements. The research also contributed valuable data for future structural strength tests of similar products and facilitated the development of safe and efficient LNG transportation solutions by developing effective test procedures in accordance with ISO 1496-3 standards.

An Empirical Study of Social Workers' Organizational Commitment : Analyzing Mediating Effect of Organizational Cynicism (사회복지사의 조직몰입에 관한 연구 : 조직 냉소주의의 매개효과를 중심으로)

  • Kang, Chul-Hee;Kim, Kyo-Seong
    • Korean Journal of Social Welfare
    • /
    • v.53
    • /
    • pp.257-283
    • /
    • 2003
  • The main objective of this study is to examine antecedents and outcome of organizational cynicism. This paper focuses on organizational commitment of social worker as outcome variable. Thus, this study attempts to examine structural relation of variables of organizational level(personnel management), job level(job characteristics), and individual level(level of self-control) on the level of organizational commitment, with special concern about the mediating effect of organizational cynicism. The study conducted mail survey and collected information for data analysis from 330 social workers working at 173 social welfare organizations in Seoul and Kyong-gi area, The study used structural equation modeling(SEM) method for analyzing the constructed model. Main results are as follows: (1) evaluation about personnel management is negatively related to organizational cynicism; (2) evaluation about job characteristics is negatively related to organizational cynicism; (3) evaluation about self-control is negatively related to organizational cynicism; (4) organizational cynicism exerts negative effect on the level of organizational commitment; and (5) evaluation about personnel management, evaluation about job characteristics, and evaluation about self-control exerts positive effect on the level of organizational commitment. Among the results of this study, this paper focuses on the function of personnel management system on organizational cynicism. This paper emphasizes that social welfare organizations must make a lot of efforts for making fair personnel system in order to reduce social workers' organizational cynicism and ultimately promote their organizational commitment.

  • PDF

Development of E-PAD based condition evaluation system for facility safety inspection (시설물 안전점검을 위한 E-PAD 기반 상태평가 시스템 개발)

  • Jung, Hae-Yong;Lee, Heung-Su;Yi, Jong-Hwa;Kim, Young-Seok;Park, Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.1-7
    • /
    • 2019
  • As a unify operational processes of the safety inspection for major national facilities, it is expected that the efficiency and professionalism of the project will be enhanced. Also it is being emphasized that the importance of visual inspection that initially find physical and functional defects in facilities. In this study, we developed an E-PAD-based condition evaluation system to check the safety of the facility to overcome the problems and limitations of the existing inspection method. This system consists of introduction, work list, visual inspection, defect table and so on. It is possible to download the inspection drawings at the site and input the damage information to the drawings and check the evaluation grade. In order to verify the E-PAD based condition evaluation system, the inspection data of 10 sample bridges were inputted into the system and the evaluation results were compared. As a result, it was confirmed that the safety grade calculated from the system and the existing safety grade are the same. The feasibility analysis of the AHP method also showed that the function increased by 10%, cost by 36%, and value by 30% compared to the existing method. Therefore, it is expected to contribute to systematic data and information analysis system for improvement of facility management.

A Study on Seismic Performance Evaluation of Road Tunnel according to Seismic Analysis Conditions (내진해석 조건에 따른 도로터널 내진성능평가에 관한 연구)

  • Choi, Byoung-Il;Kim, Chan-Hee;Noh, Eun-Cheol;Ha, Myung-Ho;Park, Si-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.127-134
    • /
    • 2021
  • When constructing a tunnel on a stable ground, stress is changed in the ground during excavation stage and installation of ground support materials. In the standards for safety evaluation of structures in use, it is suggested to perform numerical analysis reflecting the excavation stage. But method of seismic performance evaluation was not presented. Therefore, in this study, numerical analysis was performed with different analysis methods, and the results were compared and analyzed. As a result of the numerical analysis, seismic wave applied in the horizontal direction were no difference depending on the analysis methods. However, there was a big difference in the result according to the evaluation methods of tunnel member forces. When reviewing with the strength design method, the structure performance could be not satisfied depending on the existence or nonexistence of reinforcing bars. Based on these research results, it is suggested that the interpretation method should be clearly presented and reflected in the relevant standards.

Seismic Safety Evaluation of Korean R/C School Buildings Built in the 1980s (1980년대 국내 철근콘크리트 학교건물의 내진 안전성 평가에 관한 연구)

  • Lee, Kang-Seok;Wi, Jeong-Du;Kim, Yong-In;Lee, Hyun-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.5 s.57
    • /
    • pp.149-159
    • /
    • 2009
  • The main purpose of this study is to evaluate the seismic safety of Korean R/C school buildings built in the 1980s, based on "the Japanese Standard for Evaluation of Seismic Capacity of Existing R/C Buildings", the nonlinear static and the nonlinear dynamic analyses. The evaluation result of the Japanese Standard showed that R/C school buildings built in the 1980s have 0.2 through 0.4 of seismic indices($I_S$). This result indicates that more than medium damage could be potentially occurred under a medium intensity level of ground motion(150g). The results of the nonlinear analyses and the post-earthquake damage evaluation method showed that Korean R/C school buildings can be suffered moderate and severe damages under a 150gal and a 200gal intensity levels of ground motions, respectively. These results reveal that R/C school buildings should be urgently required a actual earthquake preparedness measures including seismic strengthening for future earthquake.

Structural Performance Evaluation of Floating PV Power Generation Structure System (수상 부유식 태양광발전 구조물의 구조적 성능 평가)

  • Choi, Jin Woo;Seo, Su Hong;Joo, Hyung Joong;Yoon, Soon Jong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1353-1362
    • /
    • 2014
  • In recent years, numerous environmental problems associated with the excessive use of fossil fuel are taking place. For an alternative energy resource, the importance of renewable energy and the demands of facilities to generate renewable energy are continuously rising. To satisfy such demands, a large number of photovoltaic energy generation structures are constructed and planned with large scale. However, because these facility zones are mostly constructed on land, some troubles are occurred such as rising of construction cost due to the cost of land use, environmental devastation, etc. To solve such problems, the floating type photovoltaic energy generation system using FRP members have been developed in Korea. FRP members are recently available in civil engineering applications due to many advantages such as high strength, corrosion resistance, light weight, etc. and they are suitable to fabricate the floating structures because of their material properties. In this study, the analytical and experimental investigations to evaluate the structural performance of floating PV generation structure and SMC FRP vertical member which is used to fabricate the structure were conducted. The static and dynamic performances of floating PV generation structure are evaluated through the FE analysis and the experiment, respectively. Moreover, the structural safety evaluation and buckling analysis of SMC FRP vertical compression member are also conducted by the FE analysis, and the structural behavior of SMC FRP member under compression and pullout is investigated by the experiments. From this study, it was found that the structural system composed of pultruded FRP and SMC FRP members are safe enough to resist externally applied loads.

Aging Deterioration for Electric Power Transmission Tower on Offshore Through Periodic Inspections (해상송전철탑 구조물의 주기점검을 통한 경년열화 변화특성)

  • Lee, Ho Beom;Jang, Il Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.4
    • /
    • pp.25-33
    • /
    • 2012
  • In electric power transmission tower structures on offshore, implementation of life management using the event data of regular safety inspections for structural and material damages is strongly recommended. In this study, six tower structures in Sihwa Lake around Yeoungheung island were target bodies for the safety inspections. safety inspections for deterioration about each of six towers were performed about three items for steel member, five items for concrete foundation, and four items for steel-pipe pile in seawater and seawater itself. Safety inspections for steel members included the visual observations of surface appearances, the measurements of member thicknesses, and the checks of painting states. Also safety inspections for concrete foundations comprised the estimation of crack features, the evaluation of non-destructive compression strengths, and the measurements of neutralization depths and chlorides contents. For steel-pipe piles in seawater the inspections comprised the surveys of corrosion states in accordance with potential levels tests and anode tests, the analyses of photos taken on surfaces of the piles as well as the evaluation of seawater quality. A set of deterioration inspections was performed at the same positions around october of each year for three consecutive years. As a result in this study, Newly developed deterioration indexes have been applied profitably to maintain structural safety for electric power transmission towers by utilizing these event data systematically.

Validity Evaluation of Effective Strength of Concrete Strut using Strut-Tie Model Analysis of Structural Concrete (콘크리트 구조부재의 스트럿-타이 모델 해석을 통한 스트럿 유효강도의 적합성 평가)

  • Jeun, Chang Hyun;Yun, Young Mook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.5A
    • /
    • pp.443-462
    • /
    • 2010
  • The strut-tie model approach has proven to be effective in the ultimate analysis and design of structural concrete with disturbed regions. For the reliable analysis and design by the approach, however, the effective strength of concrete struts must be determined accurately. In this study, the validity of the effective strength of concrete struts, presented by the several design codes and many researchers including the author, was examined through the ultimate strength analysis of 24 reinforced concrete panels, 275 reinforced concrete deep beams, and 218 reinforced concrete corbels by using the conventional linear strut-tie model approach of current codes. The present study shows that the author's approach, resulting in an accurate and consistent evaluation of the ultimate strength of the panels, deep beams, and corbels, may reflect rationally the effects of primary variables including the types of strut-tie model and structural concrete, the conditions of load and geometry, and the strength of concrete in the strut-tie model analysis and design of structural concrete.

A Numerical Study on Structural Safety Evaluation of Railway Bridges Deformed due to External Impact Loads (외부 충돌하중으로 변형된 철도 교량의 구조적 안전성 평가에 관한 수치 해석적 연구)

  • Dong-Woo Seo;Kyu-San Jung;Sangki Park;Jung-Hyun Kim
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.2
    • /
    • pp.75-83
    • /
    • 2023
  • In general, bridges are facilities installed for the purpose of easily passing through sections such as valleys and rivers. Railway bridges that run through downtown areas are damaged due to external factors such as earthquakes and collisions with passing vehicles, resulting in serious human casualties. This can cause serious human and properties damage, such as functional paralysis in downtown areas. Depending on the degree of damage, repair work such as partial repair or full replacement is in progress for the bridge where the collision occurred. When damage or deformation occurs due to collision, the repair method is determined according to the degree of deformation and the degree to which the load capacity of the bridge is affected by the deformation. In this study, a numerical analysis review was performed on the repair work for the local deformation caused by the collision of a vehicle on an old railway bridge installed and in operation in an urban area. To this end, a structural safety review of the bridge for local deformations caused by vehicle collisions was conducted. In this paper, a repair method for the accident bridge was presented based on the analysis results.