Modeling on Chloride Diffusivity in Concrete with Isotropic and Anisotropic Crack (등방성 및 이방성 균열을 가진 콘크리트의 염화물 확산계수 모델링)

  • Lee, Hack-Soo;Bae, Sang-Woon;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.6
    • /
    • pp.104-111
    • /
    • 2013
  • Deterioration is accelerated due to additional intrusion of chloride ion in crack width in cracked concrete. In this paper, modeling on equivalent diffusion coefficient in cracked concrete is performed for 1-D (Anisotropic) and 2-D (Isotropic) diffusion based on steady state condition. In the previous research, rectangular shape of crack was considered but the shape was modified to wedge shape with torturity. For verification of the proposed model, crack is induced in concrete sample and migration test in steady state is performed for 1-D diffusion. For 2-D diffusion, previous test results are adopted for verification. Through considering wedge shape of crack with torturity, diffusion coefficients in 1-D and 2-D diffusion are reduced, and the more reasonable prediction is obtained. The results from the proposed model with torturity of 0.10~0.15 are shown to be in the best agreement with the test results.

Assessment and Analysis of Maintenance Level According to Actual Prediction on the Main Infrastructures of North Korea (북한 주요 인프라 실태 예측에 의한 유지관리 수준 분석 및 평가)

  • Lee, Jeong-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.39-46
    • /
    • 2018
  • After the North-South Korean summit and PyeongChang Winter Olympics, it is recently expected that the North-South economic cooperation plan will be discussed in earnest. And it will be growing interest of the major infrastructure facilities such as roads and railways, and so on North-South Korean. Moreover, most of North Korean facilities have problems related to the safety and functionality of them such as aging, deterioration, and poor maintenance. This study asserts the necessity and importance of infrastructure maintenance in the Korean Peninsula. Therefore, Results of this study, it is appeared that very vulnerable to road, railroad, power/communication, water sewage and needed urgently for improvement. Accordingly, The purpose of this study is to investigate the current status for the whole facilities including the main infrastructure of the North Korean and to evaluate on the maintenance level of infrastructure based on face to face interview refugees of North Korean.

Evaluation of Durability and Self-clearing in Concrete Impregnated with Photocatalyst-colloidal Silica (광촉매-분산 실리카 함침 콘크리트의 내구성 및 정화성능 평가)

  • Kim, Hyeok-Jung;Kim, Young-Kee;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.47-54
    • /
    • 2018
  • Concrete undergoes various deterioration on surface. Impregnant with silicate is usually applied to concrete surface and forms insoluble hydrates, which can provide many engineering advantages. In the work, concrete impregnated with colloidal silicate is used for durability enhancement in surface and self-clearing performance is evaluated with photocatalyst-$TiO_2$ spraying. For the work, various tests are performed both for strength evaluation and durability evaluation such as absorption ratio, drying shrinkage, chloride penetration, sulfate resistance, and freezing/ thawing action. Furthermore, removal and self-clearing performance are evaluated with Acetaldehyde decomposition and Methylene blue decolorization. Through silicate impregnation and photocatalyst spraying, the impregnated concrete can have not only durability enhance but also self-clearing performance.

Evaluation on Sulfate Attack for Concrete Structures of Nuclear Power Plants (원자력발전소 콘크리트 구조물의 황산염 침식 평가)

  • Lee, Jong-Suk;Moon, Han-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.3
    • /
    • pp.169-176
    • /
    • 2004
  • The Mechanistic model, considering expansion stress, coefficient of diffusion etc. to time, is applied to predict the deterioration of concrete structures of the nuclear power plant(NPP) due to sulfate attack. Mix design for the test was three kinds of specified compressive strength 385, 280 and $210kgf/cm^2$ which are used to construct NPPs and cement was type I and V. The immersion test was performed with 10% $Na_2SO_4$ solution to cement type and strength for a year. The coefficient of diffusion on each concrete mix is calculated based on the results of immersion test, and it is used for predicting the sulfate attack of the concrete structures of NPP. The coefficient of diffusion of the target concrete ranged $0.5763{\sim}3.9002{\times}10^{-12}m^2/sec.$, and the sulfate attack rate of concrete structures of the NPP was predicted as 0.1~7.1 mm/year.

A Study on the Joint Property by the Surface Treatment Method on the Jointing Method of PET Film using the High Hardness Liquid (고경질 도막을 이용한 PET 필름 접합공법의 필름 표면처리 방법에 따른 접합특성 연구)

  • Lee, Jong-Suk;Kim, Young-Sam;Shin, Hong-Chol;Kim, Young-Geun;Kang, Chung-Mo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.153-159
    • /
    • 2014
  • This research reviewed the joint and duration characteristics depending on the surface treatment condition and lap spliced length in the PET film jointing method using the high hardness liquid material. As a result, the corona discharge treatment was improved to the contact angle, joint tensile strength, and joint peel resistance compared to non-treatment. Particularly, a surface treatment E (Corona discharge + Primer + PU bond + Polyester fabric) turned out to the best, and especially when the lap spliced length is longer than 15mm, stable joint performance was secured under the long term deterioration treatment of 16 weeks. Thus, the joint is considered to be applicable as the water-proof material.

A Study on the Change of Strength of FRP Member Immersed in Chemical Solution (화학약품용액에 침지한 FRP 부재의 강도 변화에 대한 연구)

  • Kim, Ho-Sun;Kim, Woo-Jong;Jang, Hwa-Sup;Kwak, Kae-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.6
    • /
    • pp.117-123
    • /
    • 2010
  • If FRP materials that have been known as high durability materials are exposed to harmful environmental factors, deterioration and characteristics of materials can be reduced due to chemical reaction such as hydrolysis. Therefore, to use FRP materials as building major materials, it is important to exactly grasp dynamic properties by use condition. Accordingly, this study stored FRP materials in a strong acid and alkali compound solution for a certain period to conduct simulation for acute or chronic, extreme changes by chemicals, and conducted a test for compressive, tensile, shear and bending strength to analyze changes in strength by kinds and storage days of chemicals. In conclusion, the study findings indicate excellent chemical resistance of FRP materials.

Experimental Study on Shear Capacity of I-slab System Using Slim Precast Slab Deck (슬림 프리캐스트 슬래브 데크를 사용한 I-슬래브 시스템의 전단 성능에 관한 실험적 연구)

  • Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.1
    • /
    • pp.126-133
    • /
    • 2017
  • This paper presents the shear capacities of hollow slab with plate and octagonal pillar type hollow sphere. Recently, the interest in precast hollow slab system for buildings is growing up according to the demand for high quality control and the increase in slab thickness. A hollow slab system is widely known as one of the effective slab system which can reduce self-weight of slab. However, hollow slabs are vulnerable to the deterioration in the shear strength due to the decrease of concrete at slab web which resists shear. Especially, in case of precast hollow slabs, it has joint surface between precast concrete slab modules along transverse axis of slab, and shear failure, that is caused by cracks at joints, has to be prevented. Therefore, in this study, shear capacity of the I-slab system is evaluated by 3-points-supported shear test along the longitudinal and transverse axis of slab specimen. Test results showed that I-slab had enough shear strength compared to theoretical shear strength even if it included the joint surfaces.

An Experimental Study on Shear Strengthening Effect of I-girder using Externally Bonded CFRP Strips (외부 부착 탄소섬유를 사용한 I형 보의 전단 보강 효과 연구)

  • Kim, Changhyuk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.108-113
    • /
    • 2018
  • Researches on strengthening and rehabilitation methods are being widely conducted due to the deterioration of existing concrete structures. Use of externally bonded Carbon Fiber Reinforced Polymers (CFRP) strips for the rehabilitation is a cost-effective and time-saving method. Generally, the CFRP layout for the shear strengthening was a uni-directional layout. Many researches have focused on the variables of the uni-directional CFRP layout such as the amount of material, angle, and spacing. Pilot tests indicated that the effective confinement of the concrete member can be provided with the bi-directional CFRP layout than the uni-directional layout. Therefore, the test was carried out after the uni- and bi-directional strengthening work using the same amount of CFRP material. CFRP anchors were installed to prevent unexpected premature CFRP delamination failure before reaching CFRP fracture strain. The effectiveness of the CFRP anchor and bi-directional CFRP layout for shear strengthening was verified based on the principal tensile strain contours.

Experimental Study on Evaluation of Bond Strength after Ozone Treatment and Ozone Resistance of Concrete Metal Spray Coating for Advanced Water Treatment (고도정수처리용 콘크리트 금속용사 피막의 내오존성 및 오존처리 후 부착강도 평가에 관한 실험적 연구)

  • Park, Jin-Ho;Jang, Hyun-O;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.68-75
    • /
    • 2018
  • The introduction of advanced water treatment facilities has increased as the conventional purification method cannot remove the substance clearly. However, the internal waterproofing and Anticorrosion materials of the advanced water treatment facility using ozone deteriorate due to the oxidation power of ozone and affects the concrete, which causes a decrease in durability. This study is to evaluate the ozone resistance according to the type of spray metal and the surface treatment method of the coating, and the bond strength after ozone treatment in order to develope a finishing method to prevent deterioration of concrete structure of water treatment facility using metal spraying method as a way to construct metal panel with excellent ozone resistance and chemical resistance by an easier way than the previous. The Experimental results show that spray metal Ti has superior ozone resistance even after spraying. It is considered to be the most suitable method for ozone resistance and bond performance by finishing using Teflon sealing as surface treatment method.

Hysteresis Characteristics of Buckling Restrained Brace with Precast RC Restraining Elements (조립형 프리캐스트 콘크리트 보강재를 가지는 비좌굴가새의 이력특성)

  • Shin, Seung-Hoon;Oh, Sang-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.1
    • /
    • pp.72-84
    • /
    • 2016
  • The conventional brace system is generally accepted as the lateral load resisting system for steel structures due to efficient story drift control and economic feasibility. But lateral stiffness of the structure decreases when buckling happens to the brace in compression, so that it results in unstable structure with unstable hysteresis behavior through strength deterioration. Buckling restrained brace(BRB) system, in which steel core is confined by mortar/concrete-filled tube, represents stable behavior in the post-yield range because the core's buckling is restrained. So, seismic performance of BRB is much better than that of conventional brace system in point of energy absorption capacity, and it is applied the most in high seismicity regions as damper element. BRBs with various shaped-sections have been developed across the globe, but the shapes experimented in Korea are now quite limited. In this study, we considered built-up type of restraining member made up of precast reinforcement concrete and the steel core. we experimented the BRB according to AISC(2005) and evaluated seismic performances and hysteresis characteristics.