• Title/Summary/Keyword: structural detail

Search Result 794, Processing Time 0.022 seconds

Signal processing based damage detection in structures subjected to random excitations

  • Montejo, Luis A.
    • Structural Engineering and Mechanics
    • /
    • v.40 no.6
    • /
    • pp.745-762
    • /
    • 2011
  • Damage detection methodologies based on the direct examination of the nonlinear-nonstationary characteristics of the structure dynamic response may play an important role in online structural health monitoring applications. Different signal processing based damage detection methodologies have been proposed based on the uncovering of spikes in the high frequency component of the structural response obtained via Discrete Wavelet transforms, Hilbert-Huang transforms or high pass filtering. The performance of these approaches in systems subjected to different types of excitation is evaluated in this paper. It is found that in the case of random excitations, like earthquake accelerations, the effectiveness of such methodologies is limited. An alternative damage detection approach using the Continuous Wavelet Transform (CWT) is also evaluated to overcome this limitation. Using the CWT has the advantage that the central frequencies at which it operates can be defined by the user while the frequency bands of the detail functions obtained via DWT are predetermined by the sampling period of the signal.

Passive vibration control of plan-asymmetric buildings using tuned liquid column gas dampers

  • Fu, Chuan
    • Structural Engineering and Mechanics
    • /
    • v.33 no.3
    • /
    • pp.339-355
    • /
    • 2009
  • The sealed, tuned liquid column gas damper (TLCGD) with gas-spring effect extends the frequency range of application up to about 5 Hz and efficiently increases the modal structural damping. In this paper the influence of several TLCGDs to reduce coupled translational and rotational vibrations of plan-asymmetric buildings under wind or seismic loads is investigated. The locations of the modal centers of velocity of rigidly assumed floors are crucial to select the design and the optimal position of the liquid absorbers. TLCGD's dynamics can be derived in detail using the extended non-stationary Bernoulli's equation for moving reference systems. Modal tuning of the TLCGD renders the optimal parameters by means of a geometrical transformation and in analogy to the classical tuned mass damper (TMD). Subsequently, fine-tuning is conveniently performed in the state space domain. Numerical simulations illustrate a significant reduction of the vibrations of plan-asymmetric buildings by the proposed TLCGDs.

Deformability and Confinement of Structural Wall with Boundary Element (단부횡보강된 구조벽의 변형능력 및 보강방법)

  • 강수민;박홍근
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.349-361
    • /
    • 2003
  • For performance-base design using nonlinear static analysis, it is required to predict the inelastic behavior of structural members accurately. In the present study, nonlinear numerical analysis was performed to develop the method describing the moment-curvature relationship of structural wall with boundary confinement. Through the numerical analysis, variations of behavioral characteristics and failure mechanism with the arrangement of vertical reiforcement and the length of boundary confinement were studied. Based on the findings, moment-curvature curves and curvature capacity for walls with a variety of re-bar arrangement was developed. By equalizing curvature capacity to demand, a design method which can determine the length of boundary confinement, was developed and for the effectiveness of boundary confinement and constructability, boundary confinement detail was proposed.

  • PDF

Seismic response control of buildings using shape memory alloys as smart material: State-of-the-Art review

  • Eswar, Moka;Chourasia, Ajay;Gopalakrishnan, N.
    • Earthquakes and Structures
    • /
    • v.23 no.2
    • /
    • pp.207-219
    • /
    • 2022
  • Seismic response control has always been a grave concern with the damage and collapse of many buildings during the past earthquakes. While there are several existing techniques like base isolation, viscous damper, moment-resisting beam-column connections, tuned mass damper, etc., many of these are succumbing to either of large displacement, near-fault, and long-period earthquakes. Keeping this viewpoint, extensive research on the application of smart materials for seismic response control of buildings was attempted during the last decade. Shape Memory Alloy (SMA) with its unique properties of superelasticity and shape memory effect is one of the smart materials used for seismic control of buildings. In this paper, an exhaustive review has been compiled on the seismic control applications of SMA in buildings. Unique properties of SMA are discussed in detail and different phases of SMA along with crystal characteristics are illustrated. Consequently, various seismic control applications of SMA are discussed in terms of performance and compared with prevalent base isolators, bracings, beam-column connections, and tuned mass damper systems.

A study on expression methods for structural aesthetics in modern fashion design - Focus on the architectural characteristics of Santiago Calatrava - (현대 구조적 패션디자인에 나타난 구조미의 표현방식에 대한 연구 - 산티아고 칼라뜨라바의 건축특성을 중심으로 -)

  • Lee, Yeonji;Um, Sohee
    • The Research Journal of the Costume Culture
    • /
    • v.23 no.5
    • /
    • pp.737-754
    • /
    • 2015
  • The structural aesthetics of architecture are becoming an inspirational source for many fashion designers and have been reborn in structural fashion. This study planned to analyze the method of expression of structural aesthetics expressed in modern structural fashion design and the construction method to maximize such an effect on the basis of the construction characteristic of Santiago Calatrava as the representative architect of the structural aesthetic. According to the study, the structural aesthetics expressed in modern structural fashion design are as follows: 1) The symbolical formative aesthetic expressed by symbolical inference and analyzation; 2) the dynamic beauty of physic expressed by visual emphasis and dynamics; and 3) the asymmetric beauty of symmetry expressed by metastasis toward the boundary between balance and imbalance. In addition, to maximize structural aesthetics, we used repetition and a progressive technique based on rhythm, asymmetry, and incision-based variances, such as balance, polygon flux, and inference, and analyzation-based distortion as the structuring principle. The following expression methods for maximizing structural aesthetics were found: 1) symbolical and structural exaggeration of appearance; 2) detail technique expansion and material property diversification; and 3) the three-dimensional transformation of structure and shell expression. Structural fashion design was found to have maximized structural aesthetics by using such expression methods to secure artistic esthetics, destroy existing shapes and patterns, and create unique shapes.

Predicting the failure modes of monotonically loaded reinforced concrete exterior beam-column joints

  • Bakir, Pelin G.;Boduroglu, Hasan M.
    • Structural Engineering and Mechanics
    • /
    • v.14 no.3
    • /
    • pp.307-330
    • /
    • 2002
  • This study aims at postulating a simple methodology for predicting the failure modes of monotonically loaded reinforced concrete beam-column joints. All the factors that affect the failure modes of joints are discussed in detail using an experimental database of monotonically loaded exterior beam-column joints. The relative contributions of the strut and truss mechanisms to joint shear strength are determined based on the test results. A simple design equation for the beam longitudinal reinforcement ratio for joints with low, medium and high amount of stirrups is developed. The factors influencing the failure modes of monotonically loaded exterior beam-column joints are investigated in detail. Design charts that predict the failure modes of exterior beam-column connections both with and without stirrups are developed. Experimental data are compared with the design charts. The results show that the simple methodology gives very accurate predictions of the failure modes.

Development of Reinforced Concrete Column and Steel Beam Composite Joints (철근콘크리트 기둥과 철골 보 합성구조 접합부 시스템 개발)

  • 김도균;정하선;최완철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.691-698
    • /
    • 2001
  • Recent trends in the construction of long span or tall building frames feature the increase use of composite members that steel and concrete is functioning together in what terms of mixed structural systems. One of such systems, RCS (reinforced concrete column and steel beam) system is introduced and closely examined focusing on bearing strength of the composite joint in this paper. The main objective of this study was to develope detail to increase bearing capacity while bearing failure is one of the two primary modes of failure in RCS system. The results show that specimens with the U-type bearing reinforcement detail developed in this study enhanced the bearing strength by 1.20-1.50. The U-type reinforcement is the effective details to increase joint bearing strength compared to others like vertical reinforcement welded to beam flanges.

  • PDF

Development of Thruster for Divert Control System (궤도 수정용 추력발생장치 개발)

  • Jeon, Young-Jin;Baek, Ki-Bong;Lim, Seol;Suh, Suhk-Hoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.364-367
    • /
    • 2011
  • The development of the DCS thrust unit during the attitude control thruster of the launch vehicle and guided missile is introduced. The DCS thrust unit using solid propellants based on a two-axis control is designed and through the thermo-structural and flow analysis is designed in detail. The performance of the thrust unit based on the detail design is demonstrated through a combustion test.

  • PDF

The basic study of the detail development of the Wall-type APT joint using Slip Form and Deck plate. (Slip Form과 Deck Plate를 채용한 벽식 APT의 접합부 Detail개발의 기초적 연구)

  • Lee, Hee-Doo;Park, Shin;Lim, Nam-Gi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.127-132
    • /
    • 2003
  • The purpose of current study is about how to construct wall-type APT in slip form and Deck plate applied different connection of materials that wall and slab. A proposal construct's solution is using the continuous a binding string that the main of contents are slab or stairs which horizon structure part construction is joined the vertical structure part, new we Proposed of 2 solution that new technology development. We'll suggest that the development is in the construct of higher stories APT more better other construction method. We expect that the new method is good but we have many things to solute themes. Thus, we decided that this development contents are needed that correct structural investigation and constructor's security of speciality and through a fact construct, correct verification.

  • PDF

Inelastic Behavior of Continuous Precast Composite Slabs (연속 프리캐스트 합성바닥판의 비탄성 거동)

  • Shim Chang-Su;Chung Young Soo;Min Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.447-450
    • /
    • 2005
  • A prefabricated composite hollow slab with perforated I-beams was suggested for the replacement of deteriorated concrete decks or the construction of new composite bridges with long-span slabs. Composite slabs with embedded I-beams have considerably higher stiffness and strength. For the application of prefabricated composite slabs to bridges, joints between slabs should satisfy the requirements of the ultimate limit state and the serviceability limit state. In this paper, three types of the detail for loop joints were selected and their structural performance in terms of strength and crack control was investigated through static tests on continuous composite slabs. A main parameter was the detail of the joint, such as an ordinary loop joint and loop joint with additional reinforcements. Even though there was no connection of the steel beams at the joints, the loop joints showed good performance in terms of strength. In terms of crack control, the loop joint with additional reinforcements showed better performance. In ultimate limit state, the continuous composite slabs showed good moment redistribution and ductility.

  • PDF