• Title/Summary/Keyword: structural acceleration

Search Result 1,111, Processing Time 0.03 seconds

Design Shear Force Reduction Factor of Upper Structure in Seismic Base-isolated System Considering Response Acceleration Decrement Effect (면진구조의 응답가속도 감소효과를 고려한 상부구조의 설계전단력 저감계수)

  • Chen, Hao;Oh, Sang-Hoon
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.7
    • /
    • pp.165-170
    • /
    • 2019
  • The structural damage caused by earthquake to the upper structure of seismic base-isolated system can be suppressed effectively because it is designed to concentrate the input energy on the seismic isolation floor. Further, the response acceleration of seismic base-isolated system can be greatly reduced compared to the seismic structure because of the long period, which means that the design shear force of the seismic base-isolated system can be reduced appropriately. However, when the design shear force is determined to be reduced, the design stiffness will decrease, and the response acceleration will increase oppositely. Therefore, for finding the extent to which the design shear force of the upper structure can be reduced, this paper considered the seismic base-isolated structure as the analytical model and proposed the design shear force reduction factor of the base-isolated structure through the dynamic response analysis, while considering the decrement effect of response acceleration. The research result shows that the response acceleration of the isolated the upper structure can be reduced by 50%~70% of the seismic structure under the same design conditions, and the design shear force can be reduced by up to 40%. By increasing the design stiffness over to 1.8 times of the original design value, the design shear force can be reduced to the same extent as the response acceleration can be reduced compared to the seismic structure.

The study of the Electro Magnetic Acceleration and Deceleration system of the Ferromagnetic Ball using the Monopole Coil Structure

  • Chung, Byung-Tae
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.1
    • /
    • pp.95-98
    • /
    • 2010
  • The Electro Magnetic (EM) Acceleration and Deceleration (ACC/DCC) system of the Ferromagnetic Ball(FB) is the linear motor's final structural development which can be used for devices that conserve energy, gaming or rail gun. By accelerating the FB within the coil structure, it is difficult to utilize the FB's magnetizing feature via the ACC/DCC system. There is much monopole space inside the monopole coil. By using this particular feature of the FB, starting coil and Monopole Coil Structure (MCS) can be structurally separated and another simple electric related control system can be experimented for further development. For the purpose of development a review is needed of the control system of both basic stepper motor and BLDC motor.

Design charts for yield acceleration and seismic displacement of retaining walls with surcharge through limit analysis

  • Aminpoor, Mohamad Mahdi;Ghanbari, Ali
    • Structural Engineering and Mechanics
    • /
    • v.52 no.6
    • /
    • pp.1225-1256
    • /
    • 2014
  • Calculating the seismic displacement of retaining walls has an important role in the optimum design of these structures. Also, studying the effect of surcharge is important for the calculation of active pressure as well as permanent displacements of the wall. In this regard, some researchers have investigated active pressure; but, unfortunately, there are few investigations on the seismic displacement of retaining walls with surcharge. In this research, using limit analysis and upper bound theorem, permanent seismic displacement of retaining walls with surcharge was analyzed for sliding and overturning failure mechanisms. Thus, a new formulation was presented for calculating yield acceleration, critical angle of failure wedge, and permanent displacement of retaining walls with surcharge. Also, effects of surcharge, its location and other factors such as height of the wall and internal friction angle of soil on the amount of seismic displacements were investigated. Finally, designing charts were presented for calculating yield acceleration coefficient and angle of failure wedge.

Highly accurate family of time integration method

  • Rezaiee-Pajand, Mohammad;Esfehani, S.A.H.;Karimi-Rad, Mahdi
    • Structural Engineering and Mechanics
    • /
    • v.67 no.6
    • /
    • pp.603-616
    • /
    • 2018
  • In this study, the acceleration vector in each time step is assumed to be a mth order time polynomial. By using the initial conditions, satisfying the equation of motion at both ends of the time step and minimizing the square of the residual vector, the m+3 unknown coefficients are determined. The order of accuracy for this approach is m+1, and it has a very low dispersion error. Moreover, the period error of the new technique is almost zero, and it is considerably smaller than the members of the Newmark method. The proposed scheme has an appropriate domain of stability, which is greater than that of the central difference and linear acceleration techniques. The numerical tests highlight the improved performance of the new algorithm over the fourth-order Runge-Kutta, central difference, linear and average acceleration methods.

An improvement to seismic design of substation support structures

  • Mohammadi, Reza Karami;Akrami, Vahid;Nikfar, Farzad
    • Structural Engineering and Mechanics
    • /
    • v.45 no.6
    • /
    • pp.821-835
    • /
    • 2013
  • The acceleration that the electrical equipment experiences on a structure can be several times the ground acceleration. Currently, substation support structures are being designed according to ASCE (Substation Structure Design Guide 2008), without any consideration about effects of these structures on dynamic behavior of mounted equipment. In this paper, a parametric study is implemented in order to improve seismic design of candlestick substation structures based on this design guide. To do this, dynamic amplification factor (DAF) of different candlestick support-equipment combinations is evaluated and compared to the target DAF presented in IEEE STD 693 (2006). Based on this procedure, a new criterion is developed to restrict maximum acceleration at support-equipment intersection.

Seismic Response Analysis of Freestanding Model of a Spent Fuel Storage Cask (사용후연료 저장용기 자유입상 모델의 지진응답해석)

  • 이재한;서기석;구경회;이홍영;최병일;정성환
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.58-65
    • /
    • 2003
  • The seismic response analysis of a freestanding spent fuel storage cask model are performed for an artificial time history acceleration generated by the basis on the US NRC RG1.60 response acceleration spectrum. This paper focuses on the structural stability by seismic loads to check the overturing possibility of storage cask and the slipping displacement on bed. Parametric analyses of a simplified cask model are performed to take into account the variations in seismic load magnitude and cask/bed interface friction. The analyses results show that the storage cask has a large marginal integrity in the response acceleration and slipping distance for both design seismic and beyond design seismic loads.

  • PDF

Influence of mass and contact surface on pounding response of RC structures

  • Khatiwada, Sushil;Larkin, Tam;Chouw, Nawawi
    • Earthquakes and Structures
    • /
    • v.7 no.3
    • /
    • pp.385-400
    • /
    • 2014
  • Pounding damage to bridges and buildings is observed in most major earthquakes. The damage mainly occurs in reinforced concrete slabs, e.g. building floors and bridge decks. This study presents the results from pounding of reinforced concrete slabs. A parametric investigation was conducted involving the mass of the pendulums, the relative velocities of impact and the geometry of the contact surface. The effect of these parameters on the coefficient of restitution and peak impact acceleration is shown. In contrast to predictions from numerical force models, it was observed that peak acceleration is independent of mass. The coefficient of restitution is affected by the impact velocity, total participating mass and the mass ratio of striker and struck block.

Hybrid Damage Monitoring Technique for Bridge Connection Via Pattern-Recognition of Acceleration and Impedance Signals (가속도 및 임피던스 신호의 특징분류를 통한 교량 연결부의 하이브리드 손상 모니터링 기법)

  • Kim, Jeong-Tae;Na, Won-Bae;Hong, Dong-Soo;Lee, Byung-Jun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.6 s.52
    • /
    • pp.57-65
    • /
    • 2006
  • This paper presents hybrid structural damage monitoring system which performs both global damage assessment of structure and damage detection of local structural joints. Hybrid damage monitoring system is composed of vibration-based technique and electro/mechanic impedance technique. Vibration-based technique detects global characteristic change ot structure using modal characteristic change of structure, and electro/mechanical impedance technique detects damage existence of local structural joints using impedance change of PZT sensor. For the verification of the proposed hybrid monitoring system, a series of damage scenarios are designed to loosened bolts situations of the structural joints, and acceleration response and impedance response signatures are measured. The proposed hybrid monitoring system is implemented to monitor global damage-state and local damages in structural joints.

Structural Effect Evaluation of an Apartment Building Due to the Water Tank under Earthquake Load (지진발생시 아파트 옥탑층 물탱크의 구조적 영향평가)

  • 정은호
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.1
    • /
    • pp.29-40
    • /
    • 1999
  • High-rise building for dwelling has many factors to be considered in structural aspects. In particular, the higher the building, the bigger the lateral loads such as wind and earthquake due to its dynamic characteristics. Unlike the wind load, the earthquake load, even if the shape of the structures are similar, depends on structural characteristics and it is difficult to predict. For an apartment building, the water tank in the penthouse, due to its heavy weight, changes the behavior of a building when the earthquake occurs. The purpose of this study is to determine how the water tank affects the behavior of an apartment building when earthquake occurs. Dynamic analysis was accomplished on two cases - 1) water tank is considered 2) water tank is not considered - to understand how it affects the behavior of a high-rise apartment building. Structural design was accomplished to understand how the water tank and the peak acceleration affects each structural member. The effect of the water tank on the response of structure was large. Elsewhere the water tank has no effect on the design of a strutural member. However some structural members were affected when the peak acceleration of an earthquake is 0.4g.

  • PDF

Structural performance evaluation of a steel-plate girder bridge using ambient acceleration measurements

  • Yi, Jin-Hak;Cho, Soojin;Koo, Ki-Young;Yun, Chung-Bang;Kim, Jeong-Tae;Lee, Chang-Geun;Lee, Won-Tae
    • Smart Structures and Systems
    • /
    • v.3 no.3
    • /
    • pp.281-298
    • /
    • 2007
  • The load carrying capacity of a bridge needs to be properly assessed to operate the bridge safely and maintain it efficiently. For the evaluation of load carrying capacity considering the current state of a bridge, static and quasi-static loading tests with weight-controlled heavy trucks have been conventionally utilized. In these tests, the deflection (or strain) of the structural members loaded by the controlled vehicles are measured and analyzed. Using the measured data, deflection (or strain) correction factor and impact correction factor are calculated. These correction factors are used in the enhancement of the load carrying capacity of a bridge, reflecting the real state of a bridge. However, full or partial control of the traffic during the tests and difficulties during the installment of displacement transducers or strain gauges may cause not only inconvenience to the traffic but also the increase of the logistics cost and time. To overcome these difficulties, an alternative method is proposed using an excited response part of full measured ambient acceleration data by ordinary traffic on a bridge without traffic control. Based on the modal properties extracted from the ambient vibration data, the initial finite element (FE) model of a bridge can be updated to represent the current real state of a bridge. Using the updated FE model, the deflection of a bridge akin to the real value can be easily obtained without measuring the real deflection. Impact factors are obtained from pseudo-deflection, which is obtained by double-integration of the acceleration data with removal of the linear components on the acceleration data. For validation, a series of tests were carried out on a steel plategirder bridge of an expressway in Korea in four different seasons, and the evaluated load carrying capacities of the bridge by the proposed method are compared with the result obtained by the conventional load test method.