• 제목/요약/키워드: stroke order

검색결과 564건 처리시간 0.027초

재가노인의 인지기능장애에 영향을 미치는 요인 (Factors Influencing Cognitive Impairment of the Elderly Residents)

  • 김은주
    • 동서간호학연구지
    • /
    • 제16권2호
    • /
    • pp.122-130
    • /
    • 2010
  • Purpose: This study was aimed at finding factors influencing cognitive impairment which is one of the typical symptoms among the demented elderly. Methods: The number of subjects was 417 elderly residents aged over 65 yr in a community. A cognitive function and a depression level were measured using the Korean Version of Mini-Mental State Examination (MMSE-K) and the Korean Form of Geriatric Depression Scale (KGDS). Alcohol abuse was measured using the CAGE instrument. Chi-square test and Logistic regression analysis were conducted to identify factors affecting cognitive impairment. Results: The prevalence rates of cognitive impairment of the sample was 43.5%. Sex, age, educational level, perceived health and alcohol abuse were strong factors influencing cognitive impairment. However, the effects of smoking, living alone, depression, family history in dementia and stroke were not strong. Conclusion: Risk for cognitive impairment were increased by being female and older than 70 yr, having low education, perceiving health as poor, and drinking alcohol abusively. Therefore, a reinforcement system, continuous research and the development of proper programs should be preformed in order to prevent cognitive impairment.

죽상동맥경화증 진단을 위한 극좌표 변환과 SE-LSTMNet 모델 (SE-LSTMNet Model Using Polar Conversion for Diagnosis of Atherosclerosis)

  • 나인예;박현진
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 추계학술대회
    • /
    • pp.294-296
    • /
    • 2022
  • 죽상동맥경화증(atherosclerosis)은 동맥에 플라크가 쌓여 혈류 장애를 일으키는 만성 혈관염증 질환으로 심장병과 뇌졸중을 일으킬 수 있다. 하지만 대부분은 동맥이 심하게 좁아질 때까지 증상이 없기 때문에 조기 발견이 중요하다. 본 논문은 튜브 모양의 혈관에서 경화성 병변을 효과적으로 진단하기 위해 MRI 영상에 혈관 중심을 기준으로 극좌표 변환을 적용하였다. 그리고, 극좌표 영상의 각도별 연속된 신호정보를 이용하는 SE-LSTMNet 모델을 제안한다. 학습된 모델은 검증 데이터에 대해 정확도 0.9194, 민감도 0.9370, 특이도 0.8796, F1 score 0.8700, AUC 0.9719의 분류 성능을 보였다.

  • PDF

Classification of Machine Learning Techniques for Diabetic Diseases Prediction

  • Sheetal Mahlan;Sukhvinder Singh Deora
    • International Journal of Computer Science & Network Security
    • /
    • 제23권12호
    • /
    • pp.204-212
    • /
    • 2023
  • Diabetes is a condition that can be brought on by a variety of different factors, some of which include, but are not limited to, the following: age, a lack of physical activity, a sedentary lifestyle, a family history of diabetes, high blood pressure, depression and stress, inappropriate eating habits, and so on. Diabetes is a disorder that can be brought on by a number of different factors. A chronic disorder that may lead to a wide range of complications. Diabetes mellitus is synonymous with diabetes. There is a correlation between diabetes and an increased chance of having a variety of various ailments, some of which include, but are not limited to, cardiovascular disease, nerve damage, and eye difficulties. There are a number of illnesses that are connected to kidney dysfunction, including stroke. According to the figures provided by the International Diabetes Federation, there are more than 382 million people all over the world who are afflicted with diabetes. This number will have risen during the years in order to reach 592 million by the year 2035. There are a substantial number of people who become victims on a regular basis, and a significant percentage of those people are uninformed of whether or not they have it. The individuals who are most adversely impacted by it are those who are between the ages of 25 and 74 years old. This paper reviews about various machine learning techniques used to detect diabetes mellitus.

Exploring geometric and kinematic correspondences between gear-based crank mechanism and standard reciprocating crankshaft engines: An analytical study

  • Amir Sakhraoui;Fayza Ayari;Maroua Saggar;Rachid Nasri
    • Structural Engineering and Mechanics
    • /
    • 제90권1호
    • /
    • pp.97-106
    • /
    • 2024
  • This paper presents a significant contribution to aided design by conducting an analytical examination of geometric links with the aim of establishing criteria for assessing an analogy measure of the extrinsic geometric and kinematic characteristics of the Variable Compression Ratio (VCR) engine with a Geared Mechanism (GBCM) in comparison to the existing Fixed Compression Ratio (FCR) engine with a Standard-Reciprocating Crankshaft configuration. Employing a mechanical approach grounded in projective computational methods, a parametric study has been conducted to analyze the kinematic behavior and geometric transformations of the moving links. The findings indicate that in order to ensure equivalent extrinsic behavior and maintain consistent input-output performance between both engine types, precise adjustments of intrinsic geometric parameters are necessary. Specifically, for a VCR configuration compared to an FCR configuration, regardless of compression ratio and gearwheel radius, for the same crankshaft ratios and stroke lengths, it is imperative to halve lengths of connecting rods, and crank radius. These insights underscore the importance of meticulous parameter adjustment in achieving comparable performance across different engine configurations, offering valuable implications for design optimization.

PZT 구동기를 이용한 지렁이 이동방식의 캡슐형 내시경용 마이크로 로봇 (An Earthworm-Like Locomotive Mechanism for Capsule Endoscopes Using PZT Actuator)

  • 지창열;박석호;윤석진;김병규;박장현
    • 대한기계학회논문집A
    • /
    • 제30권1호
    • /
    • pp.84-89
    • /
    • 2006
  • A wireless capsule endoscope has been developed to replace the conventional endoscope. However, the commercialized capsule endoscope moves passively by peristaltic waves, which has some limitations for doctors to diagnose more thoroughly and actively. In order to solve this problem, a locomotive mechanism is proposed for wireless capsule endoscopes. Based on the tests of various actuators, a piezo actuator is selected as a micro actuator for capsule endoscope. In general, piezo actuators are known to have limited displacement with high voltage supply. In order to overcome the limitation of common piezo actuator, the impact based piezo actuator, is developed to realize long stroke up 11mm. By using the impact based piezo actuator, a prototype of an earthworm-like locomotive mechanism was developed. In addition, the proposed locomotive mechanism has engraved clamps mimicked the claw of an insect. The earthworm-like locomotive mechanism has 15 mm in diameter and 30mm under retraction stage and 41 mm under elongation stage in total length. Hollow space is allocated to comprise essential endoscope components such as a camera, a communication module, bio sensors, and a battery. For the feasibility test of proposed locomotive mechanism, a series of experiments were carried out including in-vitro tests. Based on results of the experiments, we conclude that the proposed locomotive mechanism is effective to be used for micro capsule endoscopes.

플라스틱 단하지 보조기와 신발 착용이 편마비 환자의 정적 선자세 균형에 미치는 영향 (Effects of Plastic AFO and Shoes on Static Standing Balance in Hemiplegic Patients)

  • 김중휘;김중선
    • The Journal of Korean Physical Therapy
    • /
    • 제13권2호
    • /
    • pp.381-397
    • /
    • 2001
  • In the patients with hemiplegia caused by stroke and TBI. postural sway is increased and open displaced laterally over the non-affected leg, reflecting asymmetry in weight bearing on lower extremities during standing balance. Recovery of symmetric weight bearing and postural stability is an important aim in physical therapy. Plastic AFO has been used for hemiplegic patients in order to help their abnormal walking patterns. Past studies have mainly focused on the AFO influences on hemiplegic walking patterns without balance function approaches. The purpose of this study was to identify the immediate effects of plastic AFO and shoes on the static balance in hemiplegic patients. The scale for static balance were weight bearing on affected leg(%), sway area(mm2), sway path(mm), maximal sway velocity(mm/s), anteroposterior sway angle($^{\circ}$ ), and lateral angle($^{\circ}$ ). Seventeen hemiplegic patients participated in this study: 13 men and 4 women, with an average age of 50.18 years. Static balance was measured using BPM(balance performance monitor; dataprint software version 5.3) under four standing condition namely bare-foot standing. standing in shoes, standing with AFO, and standing in shoes with AFO. In order to assure the statistical significance of the results, an one-way ANOVA, the independent t-test. and a pearson's correlation were applied at the .05 level of significant. The results of this study were as follows: 1) There were statistically significant differences in weight bearing(%) on the static balance between affected leg and non-affected leg(p<.01). 2) There were statistically significant differences in sway reverse frequence(Hz) in standing with AFO between affected leg and non-affected leg(p<.05). 3) Sway area(mm2) on standing in shoes with AFO was lower than bare-foot standing(p<.05), Lateral sway angle($^{\circ}$ ) on standing in shoes with AFO was lower than bare-foot standing and standing in shoes(p<.05). 4) Weight bearing in affected leg was not significantly correlated with postural sway.

  • PDF

건강인군과 편마비군에 시행한 침, 전침 및 박동성 전기자장 치료가 상지의 체열 변화에 미치는 영향 (Thermographic Study on Effectiveness of Acupuncture, Electro-Acupuncture and Acupuncture with Pulsed Electromagnetic Therapy on Upper Extremity of Healthy and Hemiplegic Group)

  • 이종하;송미영;금동호
    • 한방재활의학과학회지
    • /
    • 제26권2호
    • /
    • pp.85-96
    • /
    • 2016
  • Objectives This study was performed to evaluate the effects of acupuncture, electro-acupuncture and acupuncture with pulsed electromagnetic therapy on upper extremity of healthy people and hemiplegic patients by D.I.T.I.. Methods 20 healthy people and 20 hemiplegic patients caused by stroke were selected. They have been treated three different types of treatment; acupuncture, electro-acupuncture and acupuncture with pulsed electromagnetic therapy. And skin temperature of upper extremity has been measured before and after each treatment by D.I.T.I.. The thermographic data was analyzed by 'Independent T-test' and 'Repeated measures ANOVA test'. Results 1. In healthy group, there was very statistical significant difference (p<0.001) of the amount of thermal change by each treatment, and the amount of change was arranged in descending order; acupuncture with pulsed electromagnetic, acupuncture and electro-acupuncture. 2. In hemiplegic group, the skin temperature of hemiplegic side was $0.97^{\circ}C$ cooler than non-hemiplegic side. 3. Skin temperature of all hemiplegic patients was increased after acupuncture treatment. 4. In hemiplegic group, there was statistical significant difference (p<0.05) of the amount of thermal change by each treatment, and the amount of change was arranged in descending order; acupuncture with pulsed electromagnetic, acupuncture and electro-acupuncture. Conclusions The results indicate that acupuncture, electro-acupuncture and acupuncture with pulsed electromagnetic therapy had good effect on the change of skin temperature by stimulating sympathetic nervous system.

동일 주파수 성분의 디젤엔진과 프로펠러 기진력 위상차 규명을 이용한 선박 진동 제어 (Ship Vibration Control Utilizing the Phase Difference Identification of Two Excitation Components with the Same Frequency Generated by Diesel Engine and Propeller)

  • 성혜민;김기선;주원호;조대승
    • 대한조선학회논문집
    • /
    • 제57권3호
    • /
    • pp.160-167
    • /
    • 2020
  • A two-stroke diesel engine and a propeller normally adopted in large merchant ships are regarded as major ship vibration sources. They are directly connected and generate various excitation components proportional to the rotating speed of diesel engine. Among the components, the magnitude of two excitation components with the same frequency generated by both engine and propeller can be compensated by the adjustment of their phase difference. It can be done by the optimization of propeller assembly angle but requires a number of burdensome trials to find the optimal angle. In this paper, the efficient estimation method to determine optimal propeller assembly angle is proposed. Its application requires the axial vibration measurement in sea trial and the numerical vibration analysis for propulsion shafting which can be substituted by additional vibration measurement after one-trial modification of propeller assembly angle. In order to verify the validity of the proposed method, the phase difference between two fifth order excitation components generated by both diesel engine and propeller of a real ship is calculated by the finite element analysis and its result is indirectly validated by the comparison of axial vibration responses at intermediate shaft obtained by the numerical analysis and the measurement in sea trial. Finally, it is numerically confirmed that axial vibration response at intermediate shaft at a resonant speed can be decreased more than 87 % if the optimal propeller assembly angle determined by the proposed method is applied.

연속 주조기의 주형 진동 진단 시스템의 개발 (Development of Diagnosis System of Mold Oscillation in a Continuous Slab Casting Machine)

  • 최재찬;이성진;조강형;전형일
    • 한국정밀공학회지
    • /
    • 제13권5호
    • /
    • pp.84-94
    • /
    • 1996
  • In order to prevent shell sticking by providing sufficient lubrication between the strand and the mold, the mold oscillation has been used. Now it is well known that the shape of the oscillation curve has a decisive effect on the surface quality of the cast product. Besides, oscillation parameters such as stroke and frequency are also very important. In order to guarantee that parameters which have been found to be optimal for a certain grade of steel do not change with time, periodical checks of the physical condition of the whole equipment are necessary. The portable mold oscillation analyzer with integrated computer, developed by POSCO, records the movement of the mold in every spatial direction. The system uses the gap sensors to measure the mold movement (displacement ) in the two horizontal directions according to the mold narrow and broad faces and the vertical strokes in the four corners of mold. The gap sensor is a non-contacting minute displacement measuring device using the principle of high frequency eddy current loss. The mold oscillation diagnosis system integrates the gap sensors, their converters and the industrial portable computer with plug-in data acquisition boards. The all programs, such as the fast Fourier transformation module (amplitude and phase spectrums) and harmonic analysis module, was coded by LabVIEW$^{TM}$ software as the graphical language. In an own 'expert module' which is included in the diagnosis program, one can obtain much information about the mold oscillation equipment.

  • PDF

저작운동시 전측두근과 교근의 근활성 및 활성시기에 관한 연구 (Electromyographic Activity, Firing Time and Sequence of the Anterior Temporalis and the Masseter on Chewing Stroke)

  • 허문일;한경수
    • Journal of Oral Medicine and Pain
    • /
    • 제24권4호
    • /
    • pp.421-437
    • /
    • 1999
  • This study was performed to investigate the electromyographic(EMG) activity, firing time and sequence of the mandibular elevator muscle on gum chewing. For this study, 28 patients with temporomandibular disorders(TMD), especially internal derangement of TM joint, and 16 dental students without any signs and symptoms in the masticatory system were selected as the patients group and as the normal group, respectively. The patients group was composed of 14 right and 14 left side affected patients. For recording of EMG activity(${\mu}V$) of the anterior temporalis(TA) and the masseter muscle(MM), and measuring of firing time(millisecond) from the start of mandibular opening movement to the firing of the muscles, BioEMG, BioEGN, and Combo program integrated in the Biopak system(Bioresearch Inc., Milwaukee, USA) were used. Gum chewing stroke was performed in both right and left side for several times, and the first and the second chewing strokes were analysed and compared with regard to EMG activity, firing time, firing sequence, correlation between EMG activity and firing time. The data obtained were analysed by SPSS windows program and the results of this study were as follows : 1. In the patients group, chewing on the affected side showed higher EMG activities in the masseter of the side than those of the contralateral side, but chewing on the unaffected side showed higher EMG activity in the masseter and in the anterior temporalis of the side than those of the contralateral side. 2. There were no difference of firing time between both sides on chewing on the affected side, but firing time in the chewing side were earlier than that of contralateral side on chewing on the unaffected side in patients group. 3. In the normal group, EMG activities in the masseter and in the anterior temporalis in the chewing side were always higher than those of the contralateral side, and there were no difference of firing time between the two sides. 4. In general, firing sequence of four muscles of both sides were ipsilateral TA, ipsilateral MM, contralateral TA, and contralateral MM in earlier order of time in both groups. Correlation coefficients between EMG activity and firing time were negative value, and more significant correlation were appeared in the normal group than in the patients group.

  • PDF