• Title/Summary/Keyword: stripping

Search Result 648, Processing Time 0.037 seconds

A Comparative study of roughness of enamel surface to various interdental enamel stripping methods in vitro (치간 법랑질 삭제방법에 따른 치아표면 거칠기에 관한 비교연구)

  • Row, Joon;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.29 no.4 s.75
    • /
    • pp.483-490
    • /
    • 1999
  • Interdental enamel stripping is an usual method for correction of abnormal tooth shape and tooth size discrepancy which is one of the etiologic factors of malocclusion. Clinically it Is useful to correct the minor crowding in anterior teeth and posterior occlusion during finishing stage of orthodontic treatment. But this procedure has risks such as irreversible tooth reduction and remaining roughness of enamel surface can accumulate plaque which can evoke periodontal problem. Even if various methods were introduced to minimize the enamel surface roughness, their evaluation was limited in morphologic differences by scanning electronic microscope(SEM). The purpose of this study was to compare the various interdental enamel stripping method by SEM and to quantify the difference of surface roughness by use of Surfcorder SEF-30D(Kosaka Lab. Ltd.) which can measure the roughness of surface. The stripping methods were divided into mechanical and mechanical-chemical method. Air-rotor stripping and separating strip were used for mechanical stripping and $37\%$ phosphoric acid was used for chemical stripping. The enamel surface roughness after mechanical or mechanical-chemical stripping of interproximal surfaces of premolars which were extracted for orthodontic purpose were measured and compared by means of SEM and $Surfcorder^{\circledR}$, the results were as follows. 1. Enamel surface of primary treated by coarse diamond bur and separating strip groups showed highest value of roughness. 2. To compare the primary treated groups between mechanical and mechanical-chemical method, the latter group showed lower value of roughness remarkably. 3. Mechanical stripping groups which were treated both coarse and fine instrument showed lower value of roughness as much as non treated group. 4. The use of Pumice for final polishing did not show significantly smoothening the stripped enamel surface any more.

  • PDF

Effect of Operational Parameters on the Ammonia Stripping (암모니아 스트리핑에 미치는 운전인자의 영향)

  • Seo, Jeong-Beom;An, Kwang-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.9
    • /
    • pp.935-939
    • /
    • 2006
  • The biological nutrient removal from domestic wastewater with low C/N ratio is difficult. Therefore, this study was performed to examine effect of operational parameters such as air supply, hydraulic retention time, pH on the nitrogen removal by ammonia stripping and to increase influent C/N ratio without required carbon source. The ammonia stripping system used for the bench-scale experiment in laboratory had a dimension of 15 cm diameter and 150 cm height. The ammonia stripping reactors were classified into two types, type AS I and type AS II, according to there using or not media. Results of the research showed that the T-N removal efficiency of AS I using plastic media is slightly higher than AS II without media. In experimental condition of air supply 30 L/min and pH 12.5, T-N removal efficiencies increased as HRT of ammonia stripping reactor became longer from 8 hr to 36 hr. In experimental condition of HRT 36 hr, it was also found that the T-N removal efficiencies improved through increase of air supply. On the other hand, C/N ratio of wastewater was increased from average 3.9 to 5.4 by ammonia stripping.

A Study on the Enamel Surface Texture and Caries Susceptibility in Interdentally Stripped Teeth (치간삭제 후의 법랑질 표면조도와 치아우식 감수성에 관한 연구)

  • Kim, Kyong-Nim;Yoon, Young-Ju;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.31 no.6 s.89
    • /
    • pp.567-578
    • /
    • 2001
  • To investigate the difference of Texture exhibited on interproximal enamel surface with each different stripping method and the susceptibility of proximal enamel to demineralization after stripping and the application of a topical fluoride go] and sealant, one hundred human premolars, which were Previously extracted for orthodontic reasons were evaluated by means of Scanning electron microscopy and laser fluorescence. The results were as follows : 1. No matter what the initial stripping instrument was the furrows that resulted from all the stripping methods were not completely removed by careful polishing. 2. Among the enamel surfaces that were treated with three different initial abrasive instruments, followed by the same polishing method (Sof-$Lex^{(r)}$ disks), the enamel surfaces that were treated with 700 crosscut carbide bur showed the smoothest surfaces. 3. The stripped teeth, no matter what the initial stripping instrument was, were less resistant to initial demineralization than untreated teeth. But no difference in caries susceptibility according to differently stripped methods was found (p<(0.001). 4. Teeth treated with APF-gel or sealant were mote resistant to demineralization than those treated without other treatment after stripping (p<0.001). 5. Comparing groups treated with APF-gel to groups treated with sealant, the former was more resistant to demineralization than the tatter (p<0.05). In conclusion, enamel surfaces that were stripped jnterproximally were less resistant to demineralization even though various attempts were made to produce smooth, self-cleaning enamel surfaces. Therefore, additional treatment-sealant or calcifying/ fluoridating solution To the stripped enamel surfaces is recommended.

  • PDF

Recovery of Mo by liquid-liquid extraction from synthetic leaching solution of spent Inconel 713C super alloy and preparation of Mo compounds (폐 인코넬계(Inconel 713C)내열합금 모의 침출액으로부터 액-액 추출법에 의한 Mo의 회수 및 Mo 화합물 제조)

  • Ahn, Jong-Gwan;Kim, Da-young;In, Yong-Hyeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.403-409
    • /
    • 2018
  • Inconel 713C which of a commercial Ni super alloy have the composition of 70 % Ni, 12 % Cr, 6 % Al and 4 % Mo. Mo is very expensive and have some economic value to recover in the alloy. In this study, liquid-liquid exraction(solvent extraction and stripping) has been performed to separate Mo from the synthetic leaching solution of spent Inconel 713C alloy and prepare to Mo powder by dying, evaporation and heat treatment. The experiments were conducted by using synthetic leaching solution which was prepared $NaMoO_4$ $2H_2O$ by dissolved in distilled water. Alamine336 and Cyanex272 dissolved in kerosene were used as extractants. The extraction percentage of Mo by Alamine336 is 99 % in the condition of the range of pH 1 to 4 and 1 % of concentration of Alamine336. The stripping solutions are used by HCl, $H_2SO_4$ and $HNO_3$ solutions and the concentrations were controlled by distilled water. The concentrations of HCl, $H_2SO_4$ and $HNO_3$ as stripping solutions are increased, the stripping percentages of Mo are increased and the stripping percentage of Mo by $HNO_3$ is higher than other stripping solutions. After liquid-liquid extraction and heat treatment, $MoO_3$ powder which of the purity of 97.5 % was prepared.

Reductive stripping of Np using a n-butyraldehyde from a loaded TBP phase containing Np (Np 함유 TBP 유기상으로부터 NBA에 의한 Np의 환원 역추출)

  • Lee, Eil-Hee;Lim, Jae-Kwan;Chung, Dong-Yong;Yang, Han-Beom;Kim, Kwang-Wook
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.3
    • /
    • pp.163-170
    • /
    • 2008
  • The reductive stripping of Np using a n-butyraldehyde (NBA) from loaded organic solution containing Np, which was oxidative-extracted in a system of a 30 % TBP/NDD-2M $HNO_3$ and O/A=2 containing 0.005 M $K_2Cr_2O_7$ as an oxidant of Np, was studied. The stripping yields of Np was increased with an increasing the NBA concentration, with a decreasing the nitric acid concentration of stripping solution and with a decreasing the reaction temperature. The apparent reductive stripping rate equation was shown by the following equation : $-d[Np]_{Org.}/dt$ = 1,524 exp(-2,906/T) $[NBA]^{0.91}\;[H^+]^{-0.92}[Np]_{Org.}$. At 1.04 M NBA and 2 M $NHO_3$, the stripping yield of Np and U was 70.1 %, and 7.1 %, respectively, and the separation factor of U over Np ($=D_U/D_{Mp}$) was about 30.4. Therefore, it was found that U and Np co-extracted in a system of TBP-$HNO_3$ could be effectively mutual-separated by the NBA.

  • PDF

Comparison of Endovenous Treatment Using a 980 nm Diode Laser versus Conventional Stripping for Truncal Saphenous Vein Incompetence: Mid-term Results by VCSS Score and Recurrence (복재정맥 부전에 대한 980-nm 다이오드 레이저를 이용한 치료와 전통적인 발거술 간의 비교: VCSS 점수와 재발에 의한 중기 임상 결과)

  • Choi, Jae-Sung;Kim, Eung-Joong;Lee, Jeong-Sang
    • Journal of Chest Surgery
    • /
    • v.43 no.4
    • /
    • pp.387-393
    • /
    • 2010
  • Background: The aims of the present study were to assess and compare mid-term clinical outcomes including recurrences between endovenous laser therapy (EVLT) and stripping. Material and Method: Between January 2007 and February 2010, 318 limbs in 237 patients with saphenous truncal varicosities were treated by laser energy using a 980 nm diode or were treated with conventional stripping. At the initial visit and at 1, 2, 6, 12, 18, 24, and 36 months postoperatively, clinical examination and questioning for Venous Clinical Severity Score (VCSS) as well as duplex ultrasonography were done. In order to compare clinical outcomes between the two treatment groups, EVLT versus stripping, all data were processed and analyzed. Result: There were no significant differences between the two treatment groups in the extent of the reflux and the number of insufficient perforating veins. The in EVLT and the stripping group at 12 months were $90.3{\pm}4.5%$ and $93.9{\pm}4.2%$, respectively (p>0.05). Total recurrence rates were 4.4% in the EVLT group and 1.5% in the stripping group (p>0.05). In both groups, the VCSS scores were significantly reduced at week 1, 1 month, and 2 months after EVLT or stripping (p<0.001). Conclusion: Efficiency in eliminating truncal saphenous vein incompetence and reducing venous clinical severity were equal in the two treatment groups.

Evaluation of Moisture Susceptibility on Asphalt Mixtures mixing Anti-Stripping Agent (박리방지제의 첨가에 따른 아스팔트 혼합물의 수분민감성 평가)

  • Yang, Sung-Lin;Hwang, Sung-Do;Kim, Yeong-Min;Jeong, Kyu-Dong
    • International Journal of Highway Engineering
    • /
    • v.10 no.4
    • /
    • pp.41-52
    • /
    • 2008
  • This study is to evaluate the property for the moisture susceptibility of asphalt mixtures using anti-stripping agent. Asphalt mixtures using lime, hydrated lime and liquid anti-stripping agent are evaluated through the three types of modified moisture conditioning($H_c$, V_s$, F-T). Indirect Tensile Test, that is recommended by AASHTO TP-9, which includes creep test, resilient modulus test and strength test is used to estimate moisture susceptibility. Analysis method through Energy Ratio(ER) that is proposed by Roque at University of Florida is used to evaluate moisture susceptibility and moisture resistance effects of asphalt mixtures using anti-stripping agent. As a test result, material property of asphalt mixtures was changed by moisture conditioning methods and the types of anti-stripping agent. Also, cracking resistance of accumulated moisture damage was changed by moisture conditioning methods and the types of anti-stripping agent. Based on test result, it was found that cracking resistance using Energy Ratio was differed from 10% to 30%.

  • PDF

A Study on the Characteristics and Cleanliness of Fluidic Strip Process of Environment-Friendly Aqueous Stripper (친환경 수계 박리액의 유동박리 공정 특성 및 청정성 연구)

  • Lee, Ki-Seong;Lee, Jaeone;Kim, Young Sung
    • Clean Technology
    • /
    • v.24 no.3
    • /
    • pp.175-182
    • /
    • 2018
  • In this research, we investigated the cleanliness by optimizing the water content of the aqueous stripper in fluidic strip process. The stripping properties of the photoresist with optimized aqueous stripper were compared with the commercial organic stripper. The stripping performance was evaluated by electrical and optical characteristics on the surface of the transparent electrode that compare with stripped the transparent electrode surface and the rare surface before patterning by the photoresist. As a result of the photoresist stripping process of the organic stripper and the aqueous stripper optimized for water content, the aqueous stripper exhibited better electrical and optical characteristics than the organic stripper. In the case of the fluidic strip process with organic stripper, the photoresist dissolves in the stripper solution during stripping which can cause re-adsorption by contamination. Whereas that the aqueous stripper under development seems to decrease the photoresist dissolution in the stripper solution. Because the cyclodextrin contained in the stripper captures organic photoresist into hall of cyclodextrin which stripped through swelling and tearing. The photoresist residue captured by the cyclodextrin can be filtered. After the fluidic stripping process by different chemical stripping mechanism, the cleanliness of the organic stripper and aqueous stripper was compared and analyzed.

Formation of Furans during the Acid Hydrolysis of Agar and Their Removal by Treatments of Lime, Steam-stripping and Hydrophobic Resins (한천의 산 당화에 의한 Furan화합물의 생성 및 제거)

  • Kim, Na-Hyun;Lee, Jae-Won;Seo, Yung-Bum;Yoon, Min-Ho
    • Korean Journal of Agricultural Science
    • /
    • v.36 no.2
    • /
    • pp.225-232
    • /
    • 2009
  • The ratio of saccharification and formation of furans during the acid hydrolysis of agar with oxalic acid and sulfuric acid were examined base on the contents of the agar and acids. The ratio of saccharification in oxalic acid appeared to be 51~59% somewhat higher than 49~61% of sulfuric acid. Formation of the furans during the acid hydrolysis increased proportional to the contents of agar and acid. The relative formation ratio was high 10~47% for furfural (FUR) and 15~29% for hydroxy-methyl furfural (HMF) in 0.5~1.25% sulfuric acid rather than those of oxalic acid. When comparing the removal efficiency of the furans using an alkali treatment, steam stripping and hydrophobic resins, FUR was eliminated 60% by the alkali treatment, 62~90% by steam stripping and 71~75% by Amberlite XAD4 and 7HP, while HMF was removed to low levels of 10.5%, 4~17% and 13~25%, respectively. The loss of reducing sugar was also observed in process of the removal of furans, and the loss rate was the level of 2~4% in alkali treatment, 11~16% in steam stripping and 7~9% in Amberlite resins.

  • PDF