• 제목/요약/키워드: stretchers

검색결과 21건 처리시간 0.034초

Active contrl of an ambulane\ce stretcher: Simulation study

  • Sagawa, K.;Inooka, H.;Ino-Oka, E.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1994년도 Proceedings of the Korea Automatic Control Conference, 9th (KACC) ; Taejeon, Korea; 17-20 Oct. 1994
    • /
    • pp.100-105
    • /
    • 1994
  • In this paper, we discuss a method for design of an ambulance stretcher which call decrease blood pressure fluctuation caused by ambulance acceleration. Recently, a lot of stretchers which can isolate the vertical vibration to reduce body resonances (4-10 Hz) have been used during ambulance transport. However, we have found that blood pressure of a patient laying in the stretcher fluctuates when the ambulance accelerates or decelerates. Since the enforced change of the blood pressure may deteriorate the patent's condition, a stretcher to cancel head-to-foot acceleration and to decrease the blood pressure variation (BPV) is expected for safe transport. We propose a method to design a stretcher which is tilted according to an adequate angle to cancel head-to-foot acceleration by gravity when the ambulance accelerates or decelerates. A control method of the stretcher is constructed by means of simulation analysis using acceleration data measured during ambulance transport. It is confirmed that the active controlled stretcher proposed has good performance for the BPV reduction.

  • PDF

첩 광섬유 격자를 이용한 광 채널-선택형 필터 (The Optical Channel-Selective Filter Using the Chirped Fiber Bragg Gratings)

  • 박세강;박진우;이상배;최상삼
    • 대한전자공학회논문지SD
    • /
    • 제38권7호
    • /
    • pp.486-492
    • /
    • 2001
  • 본 논문에서는 중심파장과 대역폭을 자유롭게 조절할 수 있는 새로운 구조의 광 채널-선택형 필터를 제안하였다. 제안된 필터는 첩 광섬유 격자의 반사 스펙트럼을 조절하기 위해 사용되는 광섬유 신장기를 부착한 동일한 세 개의 첩 광섬유 격자를 사용하여 구성하였다 파장 다중화된 입력신호 중에서 임의의 채널을 선택할 수 있는 제안된 필터의 특성을 실험적으로 보였다.

  • PDF

영역이 분리된 첩 광섬유 격자를 이용한 광 채널 스위칭용 투과 필터의 설계 (An optical channel-switching transmission filter using the segmented chirped fiber Bragg grating)

  • 박세강;박진우;구현덕;이상배
    • 한국광학회지
    • /
    • 제12권5호
    • /
    • pp.401-405
    • /
    • 2001
  • 본 논문에서는 반사대역 내부에 분리된 다수의 통과대역을 갖는 영역이 분리된 첩 광섬유 격자를 이용하여 각 채널을 독립적으로 제어할 수 있는 광 툭과 필터를 제안하였다. 영역이 분리된 첩 광섬유 격자는 원하는 영역을 설정할 수 있는 슬릿을 사용하여 제작되었다. 분리된 대역은 압전소자에 광섬유 신장기를 부착하여 조절하였고, 조절된 반사 대역은 채널을 독립적으로 선택하는데 사용되었다. 광대역 광원과 파장가변 레이저를 사용하여 투과 스펙트럼의 파장이동에 따른 입력 채널의 선택을 보였다.

  • PDF

Steel Bar를 이용한 리기다소나무 목재옹벽의 내력 평가 (Strength Evaluation of Pinus rigida Miller Wooden Retaining Wall Using Steel Bar)

  • 송요진;김건호;이동흡;황원중;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제39권4호
    • /
    • pp.318-325
    • /
    • 2011
  • 현장에서 시공성이 용이함과 동시에 강도 성능이 뛰어난 steel bar를 이용한 리기다소나무 옹벽을 제작하여 내력평가를 실시하였다. Steel bar를 이용한 목재옹벽은 횡목 4단과 종목 3단으로 적층하였으며, 높이 770 mm, 길이 2,890 mm, 폭 782 mm로 제작하였다. 적층 방법은 18 mm로 선공한 최상단과 최하단 횡목을 Steel bar에 삽입하며, 깊이 64 mm, 폭 18 mm의 슬릿을 낸 나머지 횡목과 종목을 Steel bar에 끼워 넣어 적층하였다. 완성 된 옹벽은 수평 재하 시험을 통한 내력 평가와 화상처리(AlCON 3D OPA-PRO system)를 통하여 구조물의 변형을 측정하였다. Steel bar옹벽에는 1개의 긴 횡목과 2개의 종목으로 구성된 접합부(Type-A)와 반턱으로 이음된 2개의 짧은 횡목이 2개의 종목으로 구성된 접합부(Type-B)가 공존하며, 이들을 각각 3개씩 제작하여 접합부의 압축형 전단내력 평가를 실시하였다. Steel bar옹벽의 수평 재하 시험결과 정각재 목재옹벽(박준철 등, 2010)보다 1.6배 이상의 강도를 나타냈으며, 이때 목재와 접합부의 파단은 발생하지 않았다. 접합부의 압축형 전단 내력 실험결과 Type-A의 평균 최대 하중은 130.13 kN, Type-B의 평균 최대 하중은 130.6 kN으로 측정되었다. 실험 결과 Steel bar를 이용한 목재옹벽은 정각재 목재옹벽보다 시공성이 우수하며 강도 또한 높게 측정되었다.

Strength Properties of Wooden Retaining Walls Manufactured with Pinus rigida Miller

  • Park, Jun-Chul;Kim, Keon-Ho;Lee, Dong-Heub;Son, Dong-Won;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • 제39권2호
    • /
    • pp.140-147
    • /
    • 2011
  • The strength properties of wooden retaining wall which was made with pitch pine were evaluated. Wooden retaining wall was made with diameter 90 mm of pitch pine round posts treated with CUAZ-2 (Copper Azole). The length of the front stretcher of the retaining wall was 3,000 mm. The distance between the headers (the notched member) is 1,000 mm in center and is 900 mm in side. There were connections every 2,000 mm because actually the length of stretcher is limited in the retaining wall. The strength test was carried out according to connection type because the section between stretchers can act as a defect. A result of the strength test according to connection type confirms that connection does not act as defect because the strength of retaining wall in single stretcher is similar to that in the section between stretchers. The strength test of the wooden retaining wall was carried out in 5 types according to the condition of the base section. When the upper soil pressure was 9.8 kN/$m^2$, the maximum load of the retaining wall fixing the front foundation shows higher values than those of others. But the total deformation is lower in the retaining wall not to fix a base section than in that to fix a base section. It is thought that the retaining wall not to fix a base section shows low value because the deformation is distributed throughout the retaining wall and it is confirmed that the soil pressure affects supporting the structure because the deformation of the retaining wall under low pressure is 3~4 fold higher than those of others. The failure mode of the retaining wall is the overturning type because the high section is deformed. Mostly, the failure mode is the separation of the header in the notched section.

Crib Wall System 변위해석에 관한 연구 (Study on the Displacement of Crib Wall System)

  • 김두준;이송
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권3호
    • /
    • pp.201-209
    • /
    • 2002
  • Crib wall system은 일반적으로 segmental crib type의 옹벽형식으로 stretcher라는 전 후면 가로보와 세로 방향으로 header라는 버팀보를 연속적으로 쌓아 올리는 공법이다. 이때, stretcher와 header로 구성된 골격 내부에는 흙으로 속채움을 하여 다져, 본 구조체가 일체거동이 가능한 강성체(rigid body)를 형성시킴으로써 배면의 토압에 대하여 저항하는 구조물이다. 따라서, 안정성 해석은 일반적으로 기존의 철근콘크리트 옹벽과 같이 전체 옹벽이 하나의 강성체로 작용한다고 가정하여 토압이론에 의하여 평가하고 있다. 그러나, 변형문제에 있어서 본 구조물은 단순히 하나의 구조체로 가정하여 해석하기가 곤란하다. 왜냐하면, stretcher와 header는 일반 보강토옹벽의 전면 벽체 부재와는 달리 뒷채움재 내에 어떠한 인장 보강재도 삽입되지 않기 때문에 독립된 변위거동을 나타낸다. 또한, 각각의 독립부재로 구성된 재료와 내부채움재의 힘과 변형은 3차원적으로 거동하며 수평토압에 의하여 복합적인 상호거동을 일으키기 때문이다. 따라서, 본 연구는 Crib wall system의 변위경향을 보다 엄밀하게 해석하기 위하여 Brandl(1985)의 full scale 시험 결과를 바탕으로 수치해석 모델을 제시하였다.

이동 중 주들것에서 심폐소생술 분석 (Analysis of cardiopulmonary resuscitation during main stretcher transport - A manikin study -)

  • 노상균
    • 한국응급구조학회지
    • /
    • 제24권2호
    • /
    • pp.39-50
    • /
    • 2020
  • Purpose: This study aimed to compare the effect of chest compression and the resulting ventilation volume in walking cardiopulmonary resuscitation (CPR), straddling CPR, and mechanical CPR while moving manikins to main stretchers. Methods: We compared the chest compressions in terms of compression depth, number of incomplete releases, complete release depth, compression rate, duration between peak time of previous compression and peak time of current compression, and respiration. We analyzed the compression comparatively with the ventilation volume in three different types of CPR. Results: The chest compression depth was significantly improved during straddling CPR as compared to walking CPR, during which women were unable to achieve sufficient chest compression depth. A constant chest compression depth was maintained during mechanical CPR. Conclusion: High-quality chest compressions were difficult to achieve in moving spaces. Further, walking CPR may be helpful in men, but straddling or applying automatic chest compressions in women would result in more effective CPR. Our findings demonstrate the limitations and trends in administering CPR in men and women, which may be useful in devising better education and training methods in the future.

4종류의 구급장비 및 마루(Floor) 위에서 시행한 가슴압박 에너지(kg)측정 실험에 관한 연구 (Chest Compression Energy(kg) Measurement of 4 Types of Rescue Device on the Floor)

  • 신동민;한용택;김승용;박시은
    • 한국안전학회지
    • /
    • 제29권6호
    • /
    • pp.125-131
    • /
    • 2014
  • The purpose of this study is to investigate the effect of high quality CPR using the 4 types of rescue device equipment and chest compressions energy measurement in pre-hospital settings. So, we used the mode to insert load cell in ALS Skill master Manikin to develop CFMM(Compression Force Measurement Manikin) on main stretcher, CPR board, long spine board, scoop stretcher and floor. And, our research team could know that the main stretcher needed average force of 32.55 (${\pm}1.01$) kg, CPR board of 27.23 (${\pm}1.08$) kg, long spine board of 27.13 (${\pm}1.18$) kg, Scoop Stretcher of 27.38 (${\pm}1.05$) kg and Floor of 27.24 (${\pm}0.93$) kg. CPR board must be necessary in the case of CPR on main stretcher in a moving ambulance. But if the condition of patient's back surface is the removable stretcher and the long spine plate, the patient doesn't have to be spent time to use a CPR board. Furthermore, this research suggests to consider that how to take advantage of the education to students for the equipment to check in real time the energy(kg) requirement of chest compressions.

1급 응급구조사의 직무분석에 관한 연구 (A study on the job description of paramedics)

  • 손인아
    • 한국응급구조학회지
    • /
    • 제9권1호
    • /
    • pp.43-53
    • /
    • 2005
  • The purpose of this study was to survey a perception of frequency & importance level of job performance, from 249 paramedics who were working at fire station. The job related activities of 4 duties, 18 tasks and 145 task elements were checked by 4 rating scale. The data were analyzed using a SPSS program for descriptive statistics. The results of the study were as follows ; 1. Some of the most frequent tasks were medical tx, managing people & organization, trauma care, pt assessment, general coping skill 2. Some of the most frequent task elements were preparation of written reports, operation of pt lifting supplies, transportation of patients on stretchers, administration of cervical collar and utilization of scoop stretcher. 3. Some of the highest level of importance in task were resuscitation of circulation, surgical tx, safety & infection control, environmental emergency care, trauma care. 4. Some of the highest level of importance in task elements were administration of cervical collar, adult CPR, infant CPR, child CPR, and AED. 5. The highest level of task elements in perception of frequency & importance were administration of cervical collar, infection control after pt care, utilization of long back board, disinfection of ambulance after ride a long, care of chest pain pt, care of unconscious pt, tx of asthma. 6. A difference between frequent & importance score were due to lack of supplies(41%), structural problems(30%) and medical control system(16%), lack of skills(10%), Suggestion; 1. This paper would be more reliable and confirm through wilder range of survey. 2. It would be necessary of more depth survey through dacom study from paramedic. 3. Development of field oriented protocol & curriculum that based on task elements which have high score of both frequency & importance level is required.

  • PDF

특수재난 대응 환자 격리 이송 장비의 효율성 및 편의성 평가: 마네킹시뮬레이션 연구 (Efficacy and Usability of Patient Isolation Transport Module for CBRN Disaster : A Manikin Simulation Study)

  • 김기홍;홍기정;함승희;최진우
    • 한국화재소방학회논문지
    • /
    • 제32권3호
    • /
    • pp.116-122
    • /
    • 2018
  • 본 연구의 목적은 개발 중인 화학, 생물학, 방사능 및 원자력 특수재난 대응 격리 이송 장비의 효율성과 사용 용이성을 평가하는 것이다. 상기 개발 장비는 자체 개발한 격리, 이송, 환자 감시 모듈을 통합하여 제작하였다. 응급구조사를 대상으로 한 마네킹을 이용한 무작위 교차 실험(또는 시뮬레이션)연구이며, 모든 연구대상자는 기존 장비와 특수재난 대응 격리 이송 장비의 시제품을 교대로 사용하였다. 생체신호 변화 검출 소요 시간과 치료 적용 소요 시간으로 효율성을 평가하였고 각 감시장치, 이송카트, 격리 장치 편의성에 대한 설문조사를 통해 사용 편의성으로 평가하였다. 총 12명의 응급구조사가 연구에 참여하였고 특수재난 대응 격리 이송 장비 군의 저산소증 검출 시간이 3.5초(2.5-3.9)로 기존 장비군의 4.9초(3.8-3.9)보다 유의하게 짧았다(p < 0.05). 심전도 변화 감지 소요 시간 및 안면 마스크 산소 공급 소요 시간의 감소 경향은 있었으나 통계적 유의성은 관찰되지 않았다. 특수재난 대응 격리 이송 장비 군의 환자 감시 장치의 전반적 만족도도 특수재난 대응 격리 이송 장비 군이 4점(3.5-5)으로 기존 장비군의 3점(3-3)에 비해 높았다(p < 0.05). 특수재난 대응 격리 이송 장비 사용군이 저산소증 검출 시간이 짧았으며 기존장비에 비해 환자 감시 장치의 전반적 만족도가 높은 것을 확인하였다.