Abstract

The purpose of this study is to investigate the effect of high quality CPR using the 4 types of rescue device equipment and chest compressions energy measurement in pre-hospital settings. So, we used the mode to insert load cell in ALS Skill master Manikin to develop CFMM(Compression Force Measurement Manikin) on main stretcher, CPR board, long spine board, scoop stretcher and floor. And, our research team could know that the main stretcher needed average force of 32.55 (${\pm}1.01$) kg, CPR board of 27.23 (${\pm}1.08$) kg, long spine board of 27.13 (${\pm}1.18$) kg, Scoop Stretcher of 27.38 (${\pm}1.05$) kg and Floor of 27.24 (${\pm}0.93$) kg. CPR board must be necessary in the case of CPR on main stretcher in a moving ambulance. But if the condition of patient's back surface is the removable stretcher and the long spine plate, the patient doesn't have to be spent time to use a CPR board. Furthermore, this research suggests to consider that how to take advantage of the education to students for the equipment to check in real time the energy(kg) requirement of chest compressions.

Keywords

References

  1. R. G. Thompson, "Bystander-initiated Cardiopulmonary Resuscitation in the Management of Ventricular Fibrillation", Annals of Internal Medicine, Vol. 90, No. 5, pp. 737-740, 1979. https://doi.org/10.7326/0003-4819-90-5-737
  2. G. Ritter, R. A. Wolfe, S. Goldstein, J. R. Landis, C. M. Vasu, A. Acheson and S. V. Medendrop "The Effect of Bystander CPR on Survival of Out-of-hospital Cardiac Arrest Victims", American Heart Jour., Vol. 110, No. 5, 1985.
  3. R. J. Jackson and J. P. Nolan, "Improving Outcome in Out-of-hospital Cardiac Arrest: Impact of Bystander Cardiopulmonary Resuscitation and Pre-hospital Physician Care", Critical Care, Vol. 15, No. 1, pp.102, 2011.
  4. B. S. A. Abella, J. P. Alvarado, H. Myklebust, D. P. Edelson, A. Barry, N. O'Hearn and L. B. Becker "Quality of Cardiopulmonary Resuscitation during In-hospital Cardiac Arrest", Jama, Vol. 293, No. 3, pp. 305-310, 2005. https://doi.org/10.1001/jama.293.3.305
  5. D. Hightower, S. H. Thomas, C. K. Stone, K. Dunn and J. A. March, "Decay in Quality of Closed-chest Compressions Over Time" Annals of Emergency Medicine, Vol. 26, No. 3, pp. 300-303, 1995. https://doi.org/10.1016/S0196-0644(95)70076-5
  6. S. S. Min, J. K. Kim, G. Lee, C. W. Park, H. J. Yang, E. Ryoo and Y. Kim, "Evaluation of Pertinence in Pre-hospital Triage and Management by Paramedic's Reports", Journal of the Korean Soc. Emerg. Medic., Vol. 11, No. 4, pp. 489-498, 2000.
  7. C. K. Stone and S. H. Thomas, "Can Correct Closed-chest Compressions be Performed during Pre-hospital Transport?", Pre-hospital and Disaster Medicine, Vol. 10, No. 2, pp.121-123, 1995. https://doi.org/10.1017/S1049023X00041856
  8. C. Havel, W. Schreiber, E. Riedmuller, M. Haugk, N. Richling, H. Trimmel and H. Herkner, "Quality of Closed Chest Compression in Ambulance vehicles, Flying Helicopters and at the Scene", Resuscitation, Vol. 73, No. 2, pp. 264-270, 2007. https://doi.org/10.1016/j.resuscitation.2006.09.007
  9. A. L. John, S. L. Kyoung and O. H. Sung, "Effectiveness of Chest Compression in a Moving Ambulance", J. Korean Soc. Emerg. Med., Vol. 6, No. 1, pp. 304-310, 1995.
  10. Y. J. Choi, D. S. Park, W. S. Lee, W. S. Ha, J. Y. Jung and Y. H. Yun, "Comparison of Quality in Chest Compressions at Scene, in a Moving Ambulance by Student Nurses, the 119 Member Group, and an Automatic CPR Machine", Jour. Korean Soc Emerg. Med., Vol. 20, No. 4, pp. 335-342, 2009.
  11. G. I. Sung and I. A. Hong, "A Study on the Factors Influencing the Accuracy of Chest Compression during Cardiopulmonary Resuscitation Trying in a Moving Ambulance", Jour. Korean Soc. Emerg. Med., Vol. 20, No. 4, pp.343-354, 2009.
  12. L. O. Anderson, D. L. Isbye and L. S. Rasmussen, "Increasing Compression Depth during Manikin CPR using a Simple Backboard.", Acta AnaesthesiolOgica Scandinavica, Vol. 51, No. 6, pp.747-750, 2007. https://doi.org/10.1111/j.1399-6576.2007.01304.x
  13. G. D. Perkins, L. Kocierz, S. C. Smith R. A. Mcculloch and R. P. Davies, "Compression Feedback Devices Over Estimate Chest Compression Depth when Performed on a Bed.", Resuscitation, Vol. 80, No. 1, pp.79-82, 2009. https://doi.org/10.1016/j.resuscitation.2008.08.011
  14. A. Akira et al. "Effect of Mattress Deflection on CPR Quality Assessment for Older Children and Adolescents, " Resuscitation, Vol. 80, No. 5, pp.540-549, 2009. https://doi.org/10.1016/j.resuscitation.2009.02.006
  15. G. D. Perkins, L. Kocierz, S. C. Smith R. A. Mcculloch and R. P. Davies, "Compression Feedback Devices Over Estimate Chest Compression Depth when Performed on a Bed.", Resuscitation, Vol. 80, No. 1, pp.79-82, 2009. https://doi.org/10.1016/j.resuscitation.2008.08.011
  16. A. Henry, S. Jeffrey, N. Avery, R, D. MacDonald, A. Travers, J. Tallon, M. G. Fehlings and A. Yee1," Pre-Hospital Care Management of a PotentialSpinal Cord Injured Patient: A Systematic Review of the Literature and Evidence-Based Guidelines.", J. of Neurotrauma, Vol. 28, pp.1341-1361, 2011. https://doi.org/10.1089/neu.2009.1168
  17. R. W. Koster, M. R. Sayre and M. Botha,"International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science with Treatment Recommendations. Part 5: Adult Basic Life Support", Resuscitation, Vol. 81, pp.48-70, 2010.
  18. A. J. Handley, "In-hospital Chest Compressions-the Patient on a Bed.", Resuscitation, Vol. 83, pp.795-796, 2012. https://doi.org/10.1016/j.resuscitation.2012.03.019
  19. G. J. Noordergraaf et al. "The impact of Compliant Surfaces on In-hospital Chest Compressions: Effects of Common Mattresses and a Backboard", Resuscitation, Vol. 80, pp.546-552, 2009. https://doi.org/10.1016/j.resuscitation.2009.03.023
  20. L. O. Andersen, D. L. Isble and L. S. Rasmussen" Increasing Compression Depth during Manikin CPR using a Simple Backboard.", Acta Anaesthesiologica Scandinavica, Vol. 51, Issue 6, pp.747-750, 2007. https://doi.org/10.1111/j.1399-6576.2007.01304.x
  21. J. H. Oh et al. "The use of Dual Accelerometers Improves Measurement of Chest Compression Depth.", Resuscitation, Vol. 83, Issue 4, pp.500-504, 2012. https://doi.org/10.1016/j.resuscitation.2011.09.028
  22. G. Cloete, K. H. Dellimore and C. Scheffer," Comparison of Experimental Chest Compression Data to a Theoretical Model for the Mechanics of Constant Peak Displacement CardiOpulmonary Resuscitation.", Acad. Emerg. Med., Vol. 18, No. 11, pp.1167-1176, 2011. https://doi.org/10.1111/j.1553-2712.2011.01213.x