• Title/Summary/Keyword: stress sensitivity

Search Result 847, Processing Time 0.032 seconds

Validation study on numerical simulation of RC response to close-in blast with a fully coupled model

  • Gong, Shunfeng;Lu, Yong;Tu, Zhenguo;Jin, Weiliang
    • Structural Engineering and Mechanics
    • /
    • v.32 no.2
    • /
    • pp.283-300
    • /
    • 2009
  • The characteristic response of a structure to blast load may be divided into two distinctive phases, namely the direct blast response during which the shock wave effect and localized damage take place, and the post-blast phase whereby progressive collapse may occur. A reliable post-blast analysis depends on a sound understanding of the direct blast effect. Because of the complex loading environment and the stress wave effects, the analysis on the direct effect often necessitates a high fidelity numerical model with coupled fluid (air) and solid subdomains. In such a modelling framework, an appropriate representation of the blast load and the high nonlinearity of the material response is a key to a reliable outcome. This paper presents a series of calibration study on these two important modelling considerations in a coupled Eulerian-Lagrangian framework using a hydrocode. The calibration of the simulated blast load is carried out for both free air and internal explosions. The simulation of the extreme dynamic response of concrete components is achieved using an advanced concrete damage model in conjunction with an element erosion scheme. Validation simulations are conducted for two representative scenarios; one involves a concrete slab under internal blast, and the other with a RC column under air blast, with a particular focus on the simulation sensitivity to the mesh size and the erosion criterion.

A Study on the Reduction of Over Head Crane′s Weight Considering Buckling, Vibration and Strength (좌굴, 진동, 강도를 고려한 천장크레인의 경량화에 관한 연구)

  • Hong, Do-Kwan;Ahn, Chan-Woo
    • Journal of Navigation and Port Research
    • /
    • v.26 no.3
    • /
    • pp.317-322
    • /
    • 2002
  • In this study, structural optimum design was applied to the girder of magnet over head crane. The optimization was carried out using ANSYS Code for the deadweight of girder, especially focused on the thickness of its upper, lower, side and reinforced plates. The weight could be reduced up to around 15% with constraints of its deformation, stress, natural frequency and buckling strength. The structural safety was also verified by the buckling analysis of its panel structure. It might be thought to be very useful to design the conventional structures for the weight save through the structural optimization. Also this paper grasped the sensitivity influenced the design variables upon the objective function and the state variables.

Comparison of the Diagnostic Accuracies of 1.5T and 3T Stress Myocardial Perfusion Cardiovascular Magnetic Resonance for Detecting Significant Coronary Artery Disease

  • Min, Jee Young;Ko, Sung Min;Song, In Young;Yi, Jung Geun;Hwang, Hweung Kon;Shin, Je Kyoun
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1007-1020
    • /
    • 2018
  • Objective: To compare the diagnostic performance of cardiovascular magnetic resonance (CMR) myocardial perfusion at 1.5- and 3-tesla (T) for detecting significant coronary artery disease (CAD), with invasive coronary angiography (ICA) as the reference method. Materials and Methods: We prospectively enrolled 281 patients (age $62.4{\pm}8.3$ years, 193 men) with suspected or known CAD who had undergone 1.5T or 3T CMR and ICA. Two independent radiologists interpreted perfusion defects. With ICA as the reference standard, the diagnostic performance of 1.5T and 3T CMR for identifying significant CAD (${\geq}50%$ diameter reduction of the left main and ${\geq}70%$ diameter reduction of other epicardial arteries) was determined. Results: No differences were observed in baseline characteristics or prevalence of CAD and old myocardial infarction (MI) using 1.5T (n = 135) or 3T (n = 146) systems. Sensitivity, specificity, positive and negative predictive values, and area under the receiver operating characteristic curve (AUC) for detecting significant CAD were similar between the 1.5T (84%, 64%, 74%, 76%, and 0.75 per patient and 68%, 83%, 66%, 84%, and 0.76 per vessel) and 3T (80%, 71%, 71%, 80%, and 0.76 per patient and 75%, 86%, 64%, 91%, and 0.81 per vessel) systems. In patients with multi-vessel CAD without old MI, the sensitivity, specificity, and AUC with 3T were greater than those with 1.5T on a per-vessel basis (71% vs. 36%, 92% vs. 69%, and 0.82 vs. 0.53, respectively). Conclusion: 3T CMR has similar diagnostic performance to 1.5T CMR in detecting significant CAD, except for higher diagnostic performance in patients with multi-vessel CAD without old MI.

Sensitivity Analysis of Debris Flow Simulation in Flo-2D Using Flow Discharge and Topographic Information (유량과 지형조건에 따른 Flo-2D에서의 토석류 확산 민감도 분석)

  • Kim, Namgyun;Jun, Byonghee
    • The Journal of Engineering Geology
    • /
    • v.32 no.4
    • /
    • pp.547-558
    • /
    • 2022
  • In August 2020, a debris flow occurred in Gokseon, Jeollanam-do, that resulted in the death of five residents. In this study area, high-resolution 0.03 m topographic information was generated through photogrammetry, and the amount of soil movement/loss was measured. In addition, sensitivity analysis was performed for flow depth, flow velocity, and debris flow area with the program Flo-2D using the difference in simulation parameter that discharge and topographic information. Wth increasing debris flow input discharge, increases were seen in flow depth, flow velocity, and debris flow area, as ell as in the gap in results from high-resolution topographic information and low-resolution topographic information. Also, when high-resolution topographic information was used, the results were similar to the actual (measured) flow direction of the debris flow. Therefore, the application of high-resolution topographic information increases the accuracy of the debris flow analysis results compared with low-resolution information. Results could be further imporved in the future by considering geological information such as yield stress and viscosity.

Highly Flexible Piezoelectric Tactile Sensor based on PZT/Epoxy Nanocomposite for Texture Recognition (텍스처 인지를 위한 PZT/Epoxy 나노 복합소재 기반 유연 압전 촉각센서)

  • Yulim Min;Yunjeong Kim;Jeongnam Kim;Saerom Seo;Hye Jin Kim
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.88-94
    • /
    • 2023
  • Recently, piezoelectric tactile sensors have garnered considerable attention in the field of texture recognition owing to their high sensitivity and high-frequency detection capability. Despite their remarkable potential, improving their mechanical flexibility to attach to complex surfaces remains challenging. In this study, we present a flexible piezoelectric sensor that can be bent to an extremely small radius of up to 2.5 mm and still maintain good electrical performance. The proposed sensor was fabricated by controlling the thickness that induces internal stress under external deformation. The fabricated piezoelectric sensor exhibited a high sensitivity of 9.3 nA/kPa ranging from 0 to 10 kPa and a wide frequency range of up to 1 kHz. To demonstrate real-time texture recognition by rubbing the surface of an object with our sensor, nine sets of fabric plates were prepared to reflect their material properties and surface roughness. To extract features of the objects from the detected sensing data, we converted the analog dataset to short-term Fourier transform images. Subsequently, texture recognition was performed using a convolutional neural network with a classification accuracy of 97%.

Ultrasensitive Crack-based Mechanosensor Inspired by Spider's Sensory Organ (거미의 감각기관을 모사한 초민감 균열기반 진동압력센서)

  • Suyoun Oh;Tae-il Kim
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.31 no.1
    • /
    • pp.1-6
    • /
    • 2024
  • Spiders detect even tiny vibrations through their vibrational sensory organs. Leveraging their exceptional vibration sensing abilities, they can detect vibrations caused by prey or predators to plan attacks or perceive threats, utilizing them for survival. This paper introduces a nanoscale crack-based sensor mimicking the spider's sensory organ. Inspired by the slit sensory organ used by spiders to detect vibrations, the sensor with the cracks detects vibrations and pressure with high sensitivity. By controlling the depth of these cracks, they developed a sensor capable of detecting external mechanical signals with remarkable sensitivity. This sensor achieves a gauge factor of 16,000 at 2% strain with an applied tensile stress of 10 N. With high signal-to-noise ratio, it accurately recognizes desired vibrations, as confirmed through various evaluations of external force and biological signals (speech pattern, heart rate, etc.). This underscores the potential of utilizing biomimetic technology for the development of new sensors and their application across diverse industrial fields.

Interaction Analysis between Tapered Sectional Launching Nose and Superstructure Section of ILM Concrete Bridge (변단면 압출추진코와 ILM 교량 상부단면의 상호작용 해석)

  • Lee Hwan-Woo;Jung Du-Hwoe;Ahn Tae-Wook
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.2 s.72
    • /
    • pp.139-150
    • /
    • 2006
  • ILM(incremental launching method) bridge is one of the prestressed concrete bridge construction methods widely adopted owing to its effectiveness for the quality control. The sections of the launched superstructure pass every position of the bridge spans. This launching process causes the bridge sections to be experienced in the quite different stress states with the stress state occurred after construction completely. Due to the self weight of sections, particularly, the superstructure sections(deck) experience maximum positive and negative moment as well as maximum shear force during launching process. To minimize the temporarily caused sectional forces, launching nose is generally used in the construction method. Therefore, the magnitude of this sectional forces should be checked for the safety of super structure in construction and it is dependent on the structural characteristics of launching nose. In this study, the simplified formulas to analyze the sectional force occurred by the nose-deck interaction in ILM construction are developed. The considering parameters are the span length ratio, stiffness ratio and weight ratio between the launching nose and the super structure. In particular, the developed formulas can consider the tapered sectional shape of launching nose and the diaphragm wall in the superstructure. Additionally, the sensitivity analysis is performed to analyze the effects of nose-deck interaction according to the design parameters.

Ozone Sensitivity of Physiological Indicators for Stress Evaluation in Four Families of Quercus aliena Blume (갈참나무 4가계에서 스트레스 평가용 생리 지표들의 오존 민감성)

  • Kim, Du-Hyun;Han, Sim-Hee;Lee, Jae-Cheon
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.6
    • /
    • pp.878-884
    • /
    • 2010
  • Ozone sensitivity of physiological indicators and the difference of ozone tolerance on 4 families of Quercus aliena seedlings were investigated on the basis of the standardized physiological indicators. Photosynthetic parameters, photosynthetic pigment and malondialdehyde (MDA) content, and antioxidative enzyme activities were measured or analyzed from the leaves of Q. aliena seedlings at the end of ozone fumigation, and ozone tolerance indices among 4 families were calculated with the standardized physiological parameters. After ozone treatment, the reduction of carboxylation efficiency was observed in the leaves of four families, and their reduction were ranged from -24.1% to -56.9% of control seedlings. Photosynthetic pigment content differed significantly among 4 families and treatments. The reduction of total chlorophyll content showed the highest in family SU4 (-40.6%) and the lowest family US2 (-18.8%). Ascorbate-peroxidase (APX) activity showed significant difference among families and treatments, and increased as compared with control in three families, except for family US2. On the basis of the physiological indices, ozone tolerance of four families was ranked in the order of US1 > SU4 > US2 > SU1. In conclusion, photosynthetic parameters, pigment content and APX activity were recommended as appropriate indicators to assess the tolerance against ozone stress of Q. aliena.

Flow sensor using stress-balanced membrane and thin film thermocouple (스트레스균형이 이루어진 멤버레인 및 박막 열전대를 응용한 유체센서)

  • Ahn, Yeong-Bae;Kim, Jin-Sup;Kim, Myung-Gyoo;Lee, Jong-Hyun;Lee, Jung-Hee
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.6
    • /
    • pp.51-59
    • /
    • 1996
  • A flow sensor has been fabricated by preparing thin film Pt-heater and Bi-Sb thermocouples array on 150 nm-$Si_{3}N_{4}$/300 nm-$SiO_{2}$/150 nm-$Si_{3}N_{4}$ dielectric diaphragm which has low thermal conductivity and balanced stress with silicon substrate for the purpose of improving the thermal isolation between heater and silicon substrate. Pt-heater showed nonlinear I-V characteristics due to the thermal isolation effect of the diaphragm. Its temperature coefficient of resistance was about $0.00378\;/^{\circ}C$ and Seebeck coefficient of Bi-Sb thermocouple was about $97\;{\mu}V/K$. The sensor showed that thermoelectric voltage decreased as thermal conductivity of gas increased, and flow sensitivity increased as heater voltage increased or as the distance between heater and thermocouple decreased. When heater voltage was about 2.5 V, $N_{2}$-flow sensitivity and thermal response time of the sensor were about $1.27\;mV{\cdot}(sccm)^{-1/2}$ and 0.13 sec., respectively.

  • PDF

Diagnostic Ability of Tc-99m MIBI SPECT in Coronary Artery Diseases is not Affected by the Degree of Exercise (운동 정도와 무관한 Tc-99m Methoxyisobutyl Isonitrile 심근관류 스캔의 진단능)

  • Lee, Jae-Tae;Kim, Jong-Soo;Chun, Kyung-Ah;Lee, Sang-Woo;Kang, Do-Young;Cho, Yong-Keun;Chae, Shung-Chull;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.40-48
    • /
    • 1999
  • Purpose: The sensitivity of ST-depression in the electrocardiogram during exercise is influenced by the level of efforts. However, unlike the prevalence of ST-depression on exercise ECG, the degree of exercise is reported to do not influence the diagnostic ability of myocardial perfusion scan. Furthermore, the relation between the prevalence of myocardial ischemia and effort is still controversial. We evaluated the effect of the degree of exercise on the ability of SPECT imaging to detect coronary artery stenosis. Materials and Methods: The patient population was comprised of 111 patients (73 men and 38 women, mean age 56 years) who underwent an exercise test in conjunction with Tc-99m MIBI and cardiac catheterization within 3 months apart each other. The degree of exercise was classified into four groups according to the percentage of maximal predicted heart rate. The sensitivity and specificity was compared between each group. Results: The overall diagnostic sensitivity was significantly higher with Tc-99m MIBI SPECT than exercise ECG. The specificity was not significantly different between two tests. Sensitivity and specificity of Tc-99m MIBI was not different between four groups. Sensitivity for individual coronary stenosis seemed to be lower in subjects who had premature termination of exercise due to early appearance of ST depression. Conclusion: These results suggest that the overall diagnostic sensitivity of Tc-99m MIBI myocardial perfusion SPECT is not significantly affected by the degree of exercise in stable patients undergoing symptom-limited treadmill exercise testing. Myocardial perfusion SPECT imaging should be added to routine exercise stress testing for the detection of coronary artery disease.

  • PDF