• Title/Summary/Keyword: stress distribution measurement

Search Result 213, Processing Time 0.027 seconds

A Study on the Mechanical Characteristics by the Change of Bevel Angle of Welding Joint During PWHT (溶接이음부 形狀變化에 따른 後熱處理時의 力學的 特性에 關한 硏究)

  • 방한서;강성원;김기성;김종명;노찬승
    • Journal of Welding and Joining
    • /
    • v.15 no.2
    • /
    • pp.64-71
    • /
    • 1997
  • In order to define the effects on shapes of welding joint, during Post Welding Heat Treatment (PWHT), we have carried out numerical analysis on the several test pieces by using computer program which was based on thermal-elasto-plastic-creep theories for the study. And then, welding residual stresses after PWHT were measured same test-pieces to compare with the results of numerical analysis. The main results obtained from this study is as follows: 1) The distribution modes of welding residual stresses are same on the all test pieces after and during PWHT by the both sides (measurement and numerical analysis). 2) The mechanical difference for change the thickness of plate and bevel angle are not appeared. 3) In a mechanical point of view (like material quality test, welding deformation etc.), manimum bevel angle (40$^{\circ}$.) is more suitable than maximum bevel angle (70$^{\circ}$).

  • PDF

Behavior of a Reinforced Retaining Wall During Construction (보강토의 시공중 거동 평가)

  • 노한성;최영철;백종은;김영남
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.95-100
    • /
    • 2000
  • When compared with conventional retaining wall system, there are many advantages to reinforced soil such as cost effectiveness, flexibility and so on. The use of reinforced soil have been increased in the last 17 years in Korea. In this study, a full-scale reinforced soil with rigid facing were constructed to investigate the behavior of reinforcing system. The results of soil pressure and strain of reinforcement during construction are described. The influence of compaction on soil pressure and strain of reinforcement is addressed. The results show that lateral earth pressures on the wall are active state during backfill. It is obtained that the lateral soil pressure depends on the installation condition of pressure cell and construction condition. It is also observed that maximum tensile strains of reinforcement are located on 50cm to 150cm from the wall. Long-term measurement will be followed to verify the design assumptions with respect to the distribution of lateral stress in the reinforcement

  • PDF

Development of the Bead Flush Method to Evaluate 3-Dimensional Welding Residual Stresses (3차원 용접잔류응력평가를 위한 비드플러시법의 개발)

  • Lee, Hyoung-No;Haruo, Nakamura;Hideo, Kobayashi
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.49-54
    • /
    • 2001
  • Measurement of welding residual stresses is one of important tasks to assess the structural integrity of welded structures. For operating components, especially, nondestructive techniques are required. By now, authors have proposed a new residual stress evaluation method, the bead flush method, where residual stresses are calculated from eigenstrain distribution determined by surface removal of reinforcement. In this paper, a brief description of the bead flush method is given and its utility and problem to be overcome are discussed. And also stabilization method of solution set of eigenstrain in inverse analysis is proposed.

  • PDF

Experimental Study on Thermal Analysis of Steering Control ECU Structure for Electric Vehicles (전기자동차용 조향장치 제어 ECU 구조의 열해석에 관한 실험적 연구)

  • Kim, Hae-Ji
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.5
    • /
    • pp.113-119
    • /
    • 2015
  • The technical development of electric vehicles has been actively proceeding because of the reduction of oil resources and need for eco-friendly vehicle technology. In particular, an electronic control unit is an important element in the technology of electric vehicles due to the motor drive system. This paper concerns an experimental study on the thermal analysis of the steering control ECU structure for an electric vehicle. The ECU unit is designed for eight heat sinks for the thermal analysis of the ECU structure. The thermal analysis characteristics of the ECU structure are evaluated by the temperature distribution, heat flow, von Mises stress, total translation, and external surface temperature measurement of the ECU unit.

On Study the Safety Diagnosis of Carbody Structure for Crashed Electric Multiple Units (사고전동차 구조체의 안전진단에 관한 고찰)

  • Bae Dae-Sung;Park Geun-Soo;Chung Jong-Duk
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.3
    • /
    • pp.253-259
    • /
    • 2005
  • This paper describes 3D Dimensional Measurement(EDM testing) and tensile testing results of carbody structure for crashed EMU(Electric Multiple Units). Tensile tests were performed on two different types of specimens in order to evaluate the strength changes before and after damages, obtained from plastic deformed area and nondeformed region of the crashed EMU. And Structural analysis of EMU was performed for the criteria of safety assessment. Structural analysis using commercial I-DEAS software provided important information on the stress distribution and load transfer mechanisms as well as the amount of damages during rolling stock crash. The testing results have been used to provide the critical information for the criteria of safety diagnosis.

Finite Element Analysis of Contact Behaviors of Rubber Lip Seals (고무립시일의 접촉거동에 관한 유한요소해석)

  • 김청균
    • Tribology and Lubricants
    • /
    • v.10 no.4
    • /
    • pp.82-88
    • /
    • 1994
  • This paper deals with a FEM computation as well as measurement of the contact force and distribution of the temperature in rubber lip seals when the sealing interference between the rotating shaft and the lip edge is present. The study of the contact forces and distributions of the temperature and the sealing contact stress has always been one of the basic steps in the process of designing a lip seal. The calculated FEM results indicate that as the sealing interference increases, the contact force moderately increases compared with decreased sealing interference at the seal lip edge and radically increases the contacting width. And the FEM computation of oontact forces including nonlinear problems has been compared with experimental measurements with good agreement. The frictional heat does not dissipate promptly in the rubber seal lip and tends to accumulate at the contacting lip edge especially.

Aquifer Characterization in Cheon-an area by using long-term groundwater-level monitoring data

  • 원이정;김형수;구민호;김덕근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.565-569
    • /
    • 2003
  • One-year-long groundwater-level data have been collected from 18 wells in Cheon-an area. The result of barometric efficiency, autocorrelation, cross-correlation and statistical distribution evaluated from the measurement data shows that groundwater-level measurements from observation wells are the principal source of information about aquifer characteristics. Data from WA-2 has high barometric efficiency as well as steady decreasing auto-correlation coefficient, which means nonleaky confined aquifer, Most aquifers in this study show the unconfined properties so that barometric efficiencies are mostly low and the coefficients of cross-correlation between groundwater-level and precipitation are commonly high. This study showed that the long-term groundwater-level monitoring data without artificial stress such as pumping would give accurate information about aquifer characteristics.

  • PDF

Effects of Load Ratio on Fatigue Crack Growth in a TMT Treated Al-Zn-Mg Alloy (가공열처리한 Al-Zn-Mg 합금의 피로균열 성장거동에 미치는 하중비의 영향)

  • Byun, E.S.;Kim, S.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.2 no.4
    • /
    • pp.19-26
    • /
    • 1989
  • Fundmental fatigue crack propagation tests with C-T type specimens were conducted at various load ratios (R) such as 0.1, 0.3 and 0.5 in T6 and Thermomechanically treated (TMT) conditions of 7039 Al alloy. Better mechanical properties from monotonic test as well as fatigue crack propagation were obtained by TMT process owing to uniform distribution of fine microstructures and non-existence of precipitation free zone (PFZ). Through the measurement of Kop and ${\Delta}K$ at various R the concept of effective stress intensity factor range ratio, U was reviewed to asses the load ratio effect on fatigue crack propagation. A relationship between U and variables such as ${\Delta}K$ and R was obtained empirically. This may enable us to predict ${\Delta}K_{eff}$ that is of critical importance for prediction of fatigue crack propagation rate.

  • PDF

The analysis of leakage current characteristics of polymer insulators for estimation under Pollution conditions (고분자 절연물의 내오손 진단을 위한 누설전류 특성 해석)

  • Kim, I.S.;Han, S.W.;Cho, H.G.;Soh, J.J.;Kim, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1452-1454
    • /
    • 1997
  • Properties of flashover in polymer insulators are very important under pollution environments. It is necessary to analyse flashover characteristics whether insulators are still safe or not. A lot of precious information can be got out of polluted polymer insulators through leakage current measurement. The behavior of partial arc discharge leads to flashover directly. It is possible to measure partial arc discharge as leakage current pulses analysis. The shape of histogram reflects degree of pollution, wetting and voltage stress level. It can be expressed by Weibull distribution function.

  • PDF

A Study on the Behavior of P.C. Box Girder Bridge for Temperature Gradients (온도 구배에 대한 P.C. 상자형 교량의 거동연구)

  • 손기훈;이성우
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.10a
    • /
    • pp.159-166
    • /
    • 1998
  • To study temperature effect of P.C. box girder bridge, field measurement was performed for six months, along with thermal analysis for the newly constructed viaduct of Gangbyun Highway in Seoul. Thermocouples were installed inside and surface of the flange and web of the box and temperature of box section md ambient temperature was measured. Measured environmental data are incorporated in finite element thermal analysis and computed temperature of the section was compared with measured one. Temperature gradient from thermal analysis was compared with Korean Highway Specification(1996)and the New Zealand Ministry of Works and Development code(1976). Thermal stress distribution across the box section was also compared.

  • PDF