• Title/Summary/Keyword: strength meter

Search Result 186, Processing Time 0.026 seconds

Optimization for Permeability and Electrical Resistance of Porous Alumina-Based Ceramics

  • Kim, Jae;Ha, Jang-Hoon;Lee, Jongman;Song, In-Hyuck
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.5
    • /
    • pp.548-556
    • /
    • 2016
  • Recently, porous alumina-based ceramics have been extensively applied in the semi-conductor and display industries, because of their high mechanical strength, high chemical resistance, and high thermal resistance. However, the high electrical resistance of alumina-based ceramics has a negative effect in many applications due to the generation of static electricity. The low electrical resistance and high air permeability are key aspects in using porous alumina-based ceramics as vacuum chucks in the semi-conductor industry. In this study, we tailored the pore structure of porous alumina-based ceramics by adjusting the mixing ratio of the starting alumina, which has different particle sizes. And the electrical resistance was controlled by using chemical additives. The characteristics of the specimens were studied using scanning electron microscopy, mercury porosimetry, capillary flow porosimetry, a universal testing machine, X-ray diffraction, and a high-resistance meter.

Effects of LEX on the Vortex Field over a Delta Wing (LEX가 델타형 날개의 와류 유동장에 미치는 영향)

  • 백승욱;손명환
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.83-90
    • /
    • 2002
  • An experimental study was conducted to investigate the effects of a leading edge extension(LEX) on the vortex flow field over a delta wing by measuring the total pressure distribution in a subsonic wind tunnel. Freestream velocity was 40m/sec and Reynolds number per meter was $1.76{\times}10^6$. The wing with the LEX experienced a strong interaction between the LEX and wing vortices. As the angle of attack increased, the coupled vortex field of these two vortices maintained its strength and concentricity much better than the vortex field over the wing without the LEX.

A Study on the Evaluation of Semi-Anechoic Chamber Characteristics -mainly on horizontal polarization- (전파반무향실의 특성평가에 관한 연구 - 수평편파를 중심으로 -)

  • 김동일;김민석
    • Journal of the Korean Institute of Navigation
    • /
    • v.19 no.1
    • /
    • pp.9-16
    • /
    • 1995
  • We are confronted with the serious EMI(electromagnetic interference) problems in company with the development of electronic equipments. Accordingly it is also required to construct some anechoic chambers for EMI measurement. Furthermore it is very important to evaluate the chamber characteristics in advance of its construction. For that purpose we have analyzed the characteristics by computer simulation in base on the image method, and compared the results with the measured ones. In case of 3-meter method as a result, the curved line of height pattern of open site varies similarly as that of height pattern of anechoic chamber. When we measure the electromagnetic strength and can get the height pattern curves by frequencies, we utilized it effectively because we can protect instrumental errors in measurement. On the other hand, there is a little difference in site attenuation above 700MHz. When the ferrite grid was used however, the calculated values agree well with the measured values up to 1000MHz with the exception of 30-40 MHz range. The reason is that we don't consider the antenna coupling in the low frequencies of 30-100MHz range.

  • PDF

Minimizing environmental impact from optimized sizing of reinforced concrete elements

  • Santoro, Jair F.;Kripka, Moacir
    • Computers and Concrete
    • /
    • v.25 no.2
    • /
    • pp.111-118
    • /
    • 2020
  • The construction field must always explore sustainable ways of using its raw materials. Studying the environmental impact generated by reinforced concrete raw materials during their production and transportation can contribute to reducing this impact. This paper initially presents the carbon dioxide emissions from reinforced concrete raw materials, quantified per kilo of raw material and per cubic meter of concrete with different characteristic strengths, for southern Brazil. Subsequently, reinforced concrete elements were optimized to minimize their environmental impact and cost. It was observed that lower values of carbon dioxide emissions and cost savings are generated for less resistant concrete when the structural element is a beam, and that reductions in the cross section dimensions of the beams, sized based on the use of higher strength concrete, may not compensate for the increased environmental impact and costs. For the columns, the behavior differed, presenting lower values of carbon dioxide emissions and costs for higher concrete strengths. The proposed methodology, as well as the results obtained, can be used to support structural projects that have less impact on the environment.

A Study on the Estimation of Setting Time for High Strength Concrete Using Durometer (개량형 Durometer를 이용한 고강도 콘크리트의 응결시간 추정 가능성 분석)

  • Sin, Se-Jun;Han, Soo-Hwan;Hyun, Seung-Yong;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.87-88
    • /
    • 2020
  • The purpose of this study is to explore the possibility of estimating optimum surface finish time of the fresh concrete placed at the job site by applying a surface hardness test meter(Durometer). Tests are carried out by measuring and comparing the Penetration resistance test and hardness test by Durometer. Penetration resistance tester and improved Durometer are similar, but the higher the temperature, the higher the setting time, and the higher the correlation was shown. When the hardness value of the improved Durometer is about 50 HD, it is found that the initial and 80 HD represent the end. It is expected that this will be useful in determining the finish time of the surface at the actual site.

  • PDF

Comparison of the circumference, skinfold thickness and leg strength of normal limb with those of casted limb following removal of leg cast (하지 석고붕대제거후 정상측과 석고붕대 적용측의 상하지의 둘레, 피부두겹두께 및 하지근력의 비교)

  • 최명애;박미정
    • Journal of Korean Academy of Nursing
    • /
    • v.23 no.1
    • /
    • pp.56-67
    • /
    • 1993
  • The purpose of this study was to compare the circumference and skinfold thickness of upper and lower limb and the leg strength of the casted limb with those of the normal limb after removal of a leg cast. The subjects for the study were orthopedic patients who had had long and short leg casts or splints due to tibial, fibulal, metatarsal, calcaneus fracture or ankle sprains. The subjects were divided into two groups, those who had the cast on for less than 40 days and those for over 41 days. Circumference and skinfold thickness of the upper and lower limb on the side on which the cast was ap-plied were compared with those of the contralateral side after removal of the cast. Circumference and skinfold thickness of the upper and lower limb, and leg strength for those in a cast for under 40 days were compared with those of over 41 days for both the side to which cast was applied and the contralateral side. Measurements were made after removal of the cast. Skinfold thickness was measured by fat caliper, circumference was measured by tape and lower extremity strength was determined with flat foot pressing on an electronic digital health meter in the sitting position. The results can be summarized as follows : 1. The circumference of the upper and lower leg on the side on which the cast was applied, when measured after the cast was removed, were significantly less than those of the normal side, 93.88%, 93.11% each. 2. Skinfold thickness of the quadriceps and gastrocnemius on the side on which the cast was applied were significantly less than those of the normal side when measured after removal of the cast, 85.98%, 82.85% respectively. 3. Leg strength on the side where the cast was applied was significantly 1ss than that on the normal side, 60.20%. 4. There was no difference in the circumference of upper and lower limbs, skinfold thickness or leg strength on the side where the cast was applied between the group which had the cast applied for under 40 days and the group that had it applied for over 41 days. 5. The circumference of the upper arm and lower leg on the normal side for the group that had the cast applied for over 41 days was significantly greater than the group that had the cast application for under 40 days. T ere was no difference between the two groups in the circumference of the forearm and upper leg, skinfold thickness and leg strength in the normal side. From these results, it may be concluded that muscle atrophy was apparent in the casted limb compared to the normal limb, and the circumference of the upper arm and lower leg, and leg strength on the normal side increased after removal of the cast in the group which had the cast on for more than 41 days.

  • PDF

Studies on the Effect of Diffusion Process to Decay Resistance of Mine Props (간역(簡易) 처리법(處理法)에 의한 갱목(坑木)의 내부효력(耐腐效力)에 관(關)한 연구(硏究))

  • Shim, Chong-Supp;Shin, Dong-So;Jung, Hee-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.166-166
    • /
    • 1982
  • This study has been made to make an observation regarding present status of the coal mine props which is desperately needed for coal production, despite of great shortage of the timber resources in this country, and investigate the effects of diffusion process on the decay resistances of the mine props as applied preservatives of Malenit and chromated zinc chloride. The results are as follows. 1. Present status of the coal mine props Total demand of coal mine props in the year of 1975 was approximately 456 thousand cubic meters. The main species used for mine props are conifer (mainly Pinus densiflora) and hardwood (mainly Quercus). Portions between them are half and half. With non fixed specification, wide varieties of timber in size and form are used. And volume of wood used per ton of coal production shows also wide range from 0.017 cubic meter to 0.03 cubic meter. 2. Decay resistance test a) The oven dry weight decreased between untreated specimen and treated specimen has not shown any significantly, although it has shown some differences in average values between them. It may be caused by the shorter length of the test. b) The strength of compression test between untreated specimen and treated specimen has also shown the same results as shown in case of weight decrease. Reasons assumed are the same. c) The amounts of the extractives in one percent of sodium hydroxide (NaOH) between untreated and treated specimen have shown the large value in case of untreated specimen than that of treated. 3. The economical benifit between untreated and treated wood when applied in field has seen better in long tenn base in case of treated wood, although the primary cost of treated wood add a little bit more cost than that of the untreated wood.

  • PDF

Logging for Diametric Variation of Granular Compaction Pile Using Crosshole Seismic Tests (크로스홀 탄성파 시험을 이용한 쇄석다짐말뚝의 시공직경 검측)

  • Park, Chul-Soo;Jung, Jae-Woo;Kim, Hak-Sung;Kim, Eun-Jung;Mok, Young-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1415-1426
    • /
    • 2008
  • Stone columns, locally called "GCP (granular compaction pile)" can be used to improve strength and resistance against lateral movement of a foundation soil like rigid piles and piers. Also installation of such a discrete column facilitates drainage, and densifies and reinforces the soil in the sense of ground improvement. The integrity of the GCP has been indirectly controlled with the records of each batch including depth and the quantity of stone filled. An integrity testing was attempted using crosshole S-wave logging. The method is conceptionally same as the crosshole sonic logging (CSL) for drilled piers. The only and critical difference is that S-wave should be used in the logging, because P-wave velocity of the stone column is less than that of ground water. The crosshole sonic logger does not have the capability to measure S-wave propagating through the skeleton of crushed stone. An electro-mechanical source, which can generate either P- or SH-waves, and a 1-D geophone were used to measure SH-waves. Two 76mm diameter cased boreholes were installed 1 meter apart across the nominal 700mm diameter stone column. At every 10cm of depth, shear wave was measured across the stone column. One more borehole was also installed 1 meter outward from the one of the above boreholes to measure the shear wave profile of the surrounding soil. The diametric variation of the stone column with respect to depth was evaluated from the shear wave arrival times across the stone column, and shear wave velocities of crushed stone and surrounding soil. The volume calculated with these variational diameters is very close to the actual quantity of the stone filled.

  • PDF

Design and Implementation of Portable Electrostatic Meter Applicable to Industrial Site (산업 현장에 적용할 수 있는 휴대형 정전기 측정기 설계 및 구현)

  • Jang, Mun-Seok;Lee, Eung-Hyuk
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.6_2
    • /
    • pp.971-977
    • /
    • 2020
  • In this paper, We propose a portable electrostatic meter which can measure high voltage static electricity caused by friction to prevent fire or explosion accidents in grinding, crushing, power injection, transport, filling, dust removal, painting, and foreign matter removal processes. The proposed device not only shows static electricity strength in 4 steps with respect to distance and voltage but also gives warning with a buzzer, on process facilities that are likely to generate high voltage static electricity due to friction. The device is implemented by filtering the signal detected by the wireless antenna, amplifying the signal by 6 times, and passing the signal through the integrator circuit. Tests are carried out with an electrostatic discharge simulator. And the results show that 4 LEDs are turned on at the distance of 10cm, 3 LEDs at 12cm, 2 LEDs at 13cm, and 1 LED at 15cm, when a fixed voltage of 500V is given. And also, the tests show that the static electricity can be detected at 5cm on 100V, 10cm on 200V, 15cm on 500V, 20cm on 1000V, and 25cm on 1500V. We expect to reduce accidents caused by static electricity by allowing safety managers on fields where fire or explosion accidents can happen to monitor static electricity.

Comparison of Detergency and Fabric Deformation between Ultrasonic and Home Laundry (초음파 세탁과 가정 세탁의 세척성과 직물변형 비교)

  • Nawon Hwang;Hae-won Chung;Kwang-Woo Lee
    • Fashion & Textile Research Journal
    • /
    • v.25 no.3
    • /
    • pp.386-397
    • /
    • 2023
  • In this study, the efficacy of ultrasonic washing in cotton and wool fabrics was compared and evaluated against conventional washing in terms of cleaning properties and fabric deformation. Factors such as washing temperature, time, liquid ratio, and detergent concentration were kept varied, and the cleaning properties of sebum-soiled fabrics were assessed using different detergents such as alcohol ethoxylate, linear alkylbenzenesulfonate, and IEC 60456 Reference Detergent A*. In addition, the effects and emulsification power of enzymes and oxygen bleach were examined. To compare the cleaning properties with general washing, a launder-O-meter was used. To investigate fabric deformation during the washing process, the loosening test cloth, shrinkage test cloth, and mechanical strength test cloth were compared between ultrasonic washing machines and household drum washing machines. The results indicate that ultrasonic washing exhibits superior cleaning properties than launder-O-meter when the temperature is low and the washing time is short. Furthermore, there is less deformation and damage during the washing process. It was also observed that the activity of the detergent increases when ultrasonic waves are applied to the washing process. Considering the increasing tendency to pursue convenience and simplicity in clothing management as well as the anticipated commercialization of smart clothing with built-in electric circuits, ultrasonic laundry could serve as a new alternative to existing laundry methods.