• Title/Summary/Keyword: strength intensity

Search Result 937, Processing Time 0.027 seconds

Volatile Compounds and Sensory Odor Properties of Commercial Vinegars (식초의 휘발성 성분 및 관능적 특성)

  • Yoon, Hee-Nam;Moon, Soo-Yeun;Song, Sang-Hoon
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.299-305
    • /
    • 1998
  • It was investigated to identify the volatile compounds of commercial vinegars by dynamic headspace sampling GLC-mass spectrometry, and additionally to evaluate the difference of sensory odor properties among vinegars such as brewed, cider, brown rice and persimmon vinegars. Thirty compounds were identified in four kinds of vinegar, which were composed of 9 carbonyl compounds, 12 esters, 6 alcohols and 3 acids. 3-Hydroxy-2-butanone could be merely detected in some of vinegar samples, and persimmon vinegar was characterized to include more various alcoholic compounds compared to the other kinds of vinegar. 3-Methyl-1-butanol was not detected from any samples of brewed vinegar, but from the most of cider, brown rice and persimmon vinegars. Persimmon vinegar has shown high strength of background odor intensity, and consequently was appeared to be inferior in background (p<0.05) and overall(p<0.01) odor preference scores to cider, brewed and brown rice vinegars.

  • PDF

Effect of Consolidation using Artificial Porous Material for Stone Cultural Property (인공 다공질체를 이용한 석조문화재 강화제의 처리효과)

  • Lee, Jae-Man;Lee, Myeong-Seong;Kim, Jae-Hwan;Lee, Mi-Hye
    • Journal of Conservation Science
    • /
    • v.26 no.3
    • /
    • pp.325-334
    • /
    • 2010
  • In order to clarify the effect of consolidant, the artificial porous material with low intensity was manufactured using granite powder and Portland cement. We have prepared four kinds of alkoxysilane system consolidants, a acrylic resin and a epoxy resin and investigated about characteristics before and after consolidation. As a result of the research, Silres BS OH 100 was effective for density and surface hardness. SS-101 with hydrophobicity and Site SX-RO with hydrophilicity had the good durability over salts weathering. On the other hand, Syton HT-50 and Paraloid B72 were easily destructed by salt weathering because they were concentrated on surface area by the low penetration depth. Araldite 2020 was the most effective consolidant for improvement of physical properties.

Optimum Configuration of Gutters for Glasshouses Using ANSYS and ADAMS (ANSYS/ADAMS를 이용한 유리온실 최적의 Gutter 형태 설계)

  • Kim, Jin-Soo;Ouk, Sokunthearith;Lim, Su-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.1-7
    • /
    • 2015
  • A gutter is generally a fixed beneath the edge of a roof to carry off rainwater, or a narrow trough that collects rainwater from the roof of a building to diverts it from the structure, typically into a drain. Reasonable designs reduce the mass of the gutters (~ 16.9%), make it faster and easier to assemble, and gives it consistent strength and integrity (about 10%). New gutter systems are presented according to the results of structural analyses performed by ANSYS and ADAMS/Durability Hot Spots. In addition, the CATIA program can improve the precision of the 3D system simulations. The design of a gutter system installations also needs to comply with the specific rainfall intensities and adequate overflow provisions needs to be provided to prevent water from sides of the roofs during heavy rainfall periods. The principle outcome of this work is a computational design tool that can be used to improve the gutter performance considering a variety of factors (gutter geometry, drainage and rainfall intensity). A good gutter design must satisfy many criteria, including durability, low cost, and ease of repair and cleaning.

Study on through the thickness stresses in the corner radius of a laminated composite structure (복합재 구조물의 모서리 곡면 부위에 대한 두께방향 응력 연구)

  • Kim, Sung Joon;Hwang, In Hee
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.8
    • /
    • pp.665-672
    • /
    • 2013
  • One of the major causes of stiffness and strength degradations in laminated composite structures is the delamination between composite layers. In most engineering applications, laminated composite structures have certain curvatures. If the curved composite structure is subjected to bending that tends to flatten the composite structures, through the thickness stresses can be generated in the thickness direction of the composites. Under normal operation open mode delamination could occur at the sites of peak interlaminar stress. This paper describes a technique to determine radial direction stress of a laminated composite structure using a curved beam. Stacking sequence effects of interlaminar stress were studied. The radial location and intensity of the open mode delamination stress were calculated and compared with the results obtained from the analytical solution and finite element method.

The Effects of Annealing Temperature on The Physical Properties and Fine Structure of Poly(trimethylene terephthalate)(PTT) Fibers (열처리 온도가 Poly(trimethylene terephthalate)(PTT) 섬유의 역학적 성질과 미세구조에 미치는 효과)

  • Jeong, Kyung Hui;Lee, Eon Pil;Lee, Jae Ho
    • Fashion & Textile Research Journal
    • /
    • v.15 no.6
    • /
    • pp.985-992
    • /
    • 2013
  • Polytrimethylene terephthalate(PTT) offers several advantageous properties such as good tensile strength, uniformity, stiffness, toughness, UV stability, resilience, stain resistance, outstanding elastic recovery, and dyeability. The effects of annealing temperature on physical properties and the structure of PTT filaments and yarn were investigated by measuring wide-angle X-ray diffraction (WAXD), density, optical birefringence, dynamic visco elasticity, and tensile testing. The intensity of maximum tan ${\delta}$ decreased and the temperature of maximum tan ${\delta}$ shifted to a higher temperature as the annealing temperature of filaments increased; however, it shifted to a lower temperature when the annealing temperature exceeded $130^{\circ}C$. In addition, crystallinity, density and D-spacing of (010) crystal face increased as the annealing temperature increased. Optical birefringence and specific stress were almost constant up to $100^{\circ}C$ and then decreased above $130^{\circ}C$. The shrinkage of PTT filament is 0 in boiling water when annealed above $130^{\circ}C$; consequently, the use of annealed fiber above $130^{\circ}C$ can remove thermal instability when dyeing PTT fiber. In the case of yarns, the thermal stability and physical properties of yarns showed the best effect when the ply number is less than 5, twist number is less than 400tpm, and the annealing time is 20minutes.

Measurement and Analysis of Electric and Magnetic Fields near 345[kV] Transmission Tower (345[kV] 송전철탑 주변에서 전장과 자장의 측정과 분석)

  • 이복희;이승칠;안창환;길형준;전덕규;길경석
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.3
    • /
    • pp.14-21
    • /
    • 1998
  • In this paper, the measurements of ELF electric and magnetic fields due to double circuit 345[kV} transmission lines are made using planar-type electric field sensor and multitum loop-type magnetic field sensor, and the magnitudes of electric and magnetic fields are illustrated by a three-dimensional plot. Also, in order to predict the magnetic field strength with lad variation, a typical daily load current curves of the transmission lines are displayed because the magnetic field is changed with load current. experimental results of ELF electric and magnetic fields along center line versus lateral distance are compared with the theoretical values computed by using the FIELDS program. The electric field intensity in and around a transmission tower is lowered, and the greatest point of the magnetic field is shifted to the heavy load line but generally is given the trend that the peak value appear at the central part of the transmission tower. The magnitudes of the maximum electric and magnetic fields in the vicinity of a transmission tower are less than 3.5[kV/m] and $20[{\mu}T]$, respectively. The measured electric and magnetic fields are satisfied with limits and guidelines recommended by various authorized international institutes.

  • PDF

Measurement of Gamma ray Spectrum for the 27Al(p,3p+n)24Na Nuclear Reaction by using 100 MeV Proton Acceleration System (100 MeV 양성자가속기를 이용한 27Al(p,3p+n)24Na 핵반응에 대한 감마선 스펙트럼 측정)

  • Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.55-59
    • /
    • 2015
  • Research about the proton nuclear reaction is actively achieving on the proton therapy including material development of fusion reactor. The proton induced gamma ray energy(2754, 1386 keV) spectrum of 27Al(p,3p+n)24Na reaction was measured with 100 MeV high energy proton beam. The proton beam in the experiment was derived from 100 MeV proton linear accelerator in the KOMAC. We measured the gamma ray intensity ratio of the decay level from the energy spectrum. The previous results have been compared with the current result. Strength of measured gamma rays will provide very important information though decide high energy gamma radiation detection efficiency.

Effect of Calcium Addition on Physicochemical Properties of Cellulose-Based Edible Films (칼슘을 첨가한 셀롤로우스 식용필름의 이화학적 특성)

  • Song, Tae-Hee;Kim, Chul-Jai
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.99-105
    • /
    • 1999
  • The preparation and the functional properties of methylcellulose (MC) and hydroxypropyl-methylcellulose (HPMC) edible films with and without calcium were investigated. All the prepared films exhibited transparent and whitish color with $2.38{\sim}3.55$ haze intensity. Tensile strength of MC films were stronger than HPMC films with and without calcium, and moreover addition of calcium increased tensile, but elongation of HPMC film was specially lower than the other films. Solubility of films did not differ with calcium addition but decreased with increasing viscosity in HPMC films. water vapor transmission rate (WVTR) of HPMC and MC film were not affected by calcium, but viscosity of film's raw material was important to determine WVTR in HPMC. Oxygen permeabilities of MC films were lower than those of HPMC films, and became lower with calcium addition. According to scanning electron microscope (SEM) observation on the surface characteristics, MC film with calcium had relatively uniform and smooth surface than HPMC films.

  • PDF

Shallow Failure Characteristics of Weathered Granite Soil Slope in accordance with the Rainfall Infiltration (강우침투에 따른 화강풍화토 사면의 얕은파괴 특성)

  • Kim, Sun-Hak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2810-2818
    • /
    • 2009
  • In order to examine the characteristic of shallow failure in cut slopes composed of weathered granite soil, this study calculated critical permeability coefficient according to rainfall characteristic in Korea, performed stability analysis according to the representative physical properties of weathered granite soil distributed in Korea such as horizontal distance to the failure surface of cut slope, slope inclination, slope height, and the depth of wetting by rainfall, and analyzed the results. In the results of analyzing critical permeability coefficient, when the local rainfall characteristic was considered, the maximum critical permeability coefficient was $7.16{\times}10^{-4}cm/sec$. We judged that shallow failure according to wetting depth should be considered when rainfall below the critical rainfall intensity lasts longer than the minimum rainfall duration in cut slopes composed of weathered granite soil, which had a critical permeability coefficient lower than the maximum critical permeability coefficient. Furthermore, using simulated failure surface, this study could understand the characteristic of shallow failure in cut slopes based on the change in slope safety factor according to horizontal distance, wetting depth, and strength parameter.

Experimental Study on the Slope Failure of Embankment (성토사면의 붕괴에 관한 실험적 연구)

  • 강우묵;이달원;지인택;조재홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.35 no.3
    • /
    • pp.47-62
    • /
    • 1993
  • The laboratorv model test was carried out to investigate the behavior of pore water pressure, the critical amount of rainfall for slope failure, the pattern of failure, and the variation of seepage line at the slope with the uniform material of embankment by changing the slope angles and rainfall intensities. The results were was summarised as follows : 1.At the beginning stage of rainfall, the negative pore pressure appeared at the surface of slope and the positive pore pressure at the deep parts. But, the negative one turned into the positive one as the rainfall continued and this rapidly increased about 50 to 100 minutes before the slope failure. 2.The heavier the rainfall intensity, the shorter the time, and the milder the slope, the longer the time took to reach the failure of slope. 3.As the angle of the slope became milder, the critical amount of rainfall for slope failure became greater. 4.Maximum pore water pressure was 10 to 40g/cm$^2$ at the toe of slope and 50 to 90g/cm$^2$at the deep parts. 5.In the respect of the pattern of slope failure, surface failure of slope occurred locally at the toe of slope at the A-soil and failure of slope by surface flow occurred gradually at the top part of slope at the B-soil. 6.As the rainfall continued and the saturation zone in the embankment was formed, the seepage line went rapidly up and also the time to reach the total collapse of slope took longer at the B-soil. 7.As the position of the seepage line went up and the strength parameter accordingly down, the safety factor was 2.108 at the A-soil and 2.150 at the B-soil when the slope occured toe failure. Minimum safety factor was rapidly down to 0.831 at the A-soil and to 0.936 at the B-soil when the slope collapsed totally at the top part of slope.

  • PDF