• 제목/요약/키워드: strength ductility

검색결과 1,766건 처리시간 0.026초

Performance of FRP confined and unconfined geopolymer concrete exposed to sulfate attacks

  • Alzeebaree, Radhwan;Gulsan, Mehmet Eren;Nis, Anil;Mohammedameen, Alaa;Cevik, Abdulkadir
    • Steel and Composite Structures
    • /
    • 제29권2호
    • /
    • pp.201-218
    • /
    • 2018
  • In this study, the effects of magnesium sulfate on the mechanical performance and the durability of confined and unconfined geopolymer concrete (GPC) specimens were investigated. The carbon and basalt fiber reinforced polymer (FRP) fabrics with 1-layer and 3-layers were used to evaluate the performances of the specimens under static and cyclic loading in the ambient and magnesium sulfate environments. In addition, the use of FRP materials as a rehabilitation technique was also studied. For the geopolymerization process of GPC specimens, the alkaline activator has selected a mixture of sodium silicate solution ($Na_2SiO_3$) and sodium hydroxide solution (NaOH) with a ratio ($Na_2SiO_3/NaOH$) of 2.5. In addition to GPC specimens, an ordinary concrete (NC) specimens were also produced as a reference specimens and some of the GPC and NC specimens were immersed in 5% magnesium sulfate solutions. The mechanical performance and the durability of the specimens were evaluated by visual appearance, weight change, static and cyclic loading, and failure modes of the specimens under magnesium sulfate and ambient environments. In addition, the microscopic changes of the specimens due to sulfate attack were also assessed by scanning electron microscopy (SEM) to understand the macroscale behavior of the specimens. Results indicated that geopolymer specimens produced with nano-silica and fly ash showed superior performance than the NC specimens in the sulfate environment. In addition, confined specimens with FRP fabrics significantly improved the compressive strength, ductility and durability resistance of the specimens and the improvement was found higher with the increased number of FRP layers. Specimens wrapped with carbon FRP fabrics showed better mechanical performance and durability properties than the specimens wrapped with basalt FRP fabrics. Both FRP materials can be used as a rehabilitation material in the sulfate environment.

GFRP를 이용한 경량합성바닥의 휨성능에 대한 실험적 평가 (An Experimental Evaluation on Flexural Performance of Light-Weight Void Composite Floor using GFRP)

  • 류재호;박세호;주영규;김상대
    • 한국강구조학회 논문집
    • /
    • 제23권1호
    • /
    • pp.125-135
    • /
    • 2011
  • 최근 타워형 아파트구조에 많이 사용되고 있는 무량판 구조시스템을 대신해 층고절감 및 장스팬 구현 그리고 내화성능향상을 목적으로 GFRP를 이용한 경량합성바닥을 개발하였다. GFRP를 이용한 경량합성바닥은 웨브에 개구부를 가지는 비대칭 강재보 하부에 GFRP를 부착하고 슬래브에 경량체를 삽입한 중공합성바닥이다. 이에 개발된 합성바닥의 휨성능을 평가하기 위해 GFRP, 중공률, 웨브의 개구부 등을 변수로 실대 실험을 수행하였다. 그 결과 GFRP를 이용한 합성보 실험체는 기준 실험체에 비해 휨내력 및 강성 측면에서 10% 높은 성능을 나타냈으며, 구조물이 항복할 때까지 완전합성거동하였다. 항복 이후 웨브개구부 주변의 응력집중현상에 의해 연성이 감소하는 현상이 나타났으며, 최대내력점까지 미끄러짐의 발생은 미소하였다. 내력설계 측면에서는 안전율을 고려해 해석값의 85%를 설계내력으로 평가하는 것이 타당한 것으로 나타났다.

단부 횡보강된 구조벽의 모멘트-곡률 관계 (Moment-Curvature Relationship of Structural Wells with Confined Boundary Element)

  • 강수민;박홍근
    • 콘크리트학회논문집
    • /
    • 제15권2호
    • /
    • pp.323-334
    • /
    • 2003
  • 비선형정적해석과 같은 성능기초설계를 위해서는 부재의 비선형거동을 정확하게 예측하여야 한다. 본 연구에서는 단부횡보강된 구조벽의 휨모멘트-곡률관계를 구하는 방법을 개발하기 위하여 해석연구를 실시하였다. 비선형해석을 수행하여 수직방향 철근의 배치형태와 단부횡보강 길이의 변화에 따른 구조벽체의 거동특성과 파괴 메카니즘의 변화를 연구하였다. 분석결과, 적절하게 횡보강된 벽체의 최대강도는 비횡보강 콘크리트가 극한 압축변형율에 도달하는 경우에 발생한다. 단부집중배근을 갖는 벽체에서는 취성파괴가 일어나며, 웨브의 수직철근은 연성파괴를 유도하는 역할을 한다. 이러한 연구결과에 근거하여 다양한 배근형태를 갖는 벽체에 대한 모멘트-곡률관계를 정의하였다. 이 제안된 관계에 따르면 단부횡보강된 구조벽체의 변형능력은 재하된 압축력에 비하여 횡보강 콘크리트의 압축재하능력이 증가할수록 증가한다.

순환골재와 고로슬래그 미분말을 치환한 강섬유 보강 RC보의 구조성능 평가 (Evaluation of Structural Performance of RC Beams Retrofitted Steel Fiber consequential Replacement of Recycled Coarse Aggregate and Ground Granulated Blast Furnace Slag)

  • 하기주;이동렬;하재훈
    • 콘크리트학회논문집
    • /
    • 제25권5호
    • /
    • pp.477-484
    • /
    • 2013
  • 이 연구에서는 순환골재와 고로슬래그 미분말의 치환율에 따른 강섬유 보강 RC보의 구조성능 향상을 위하여 표준실험체(BSS), 성능개선 실험체로는 순환골재와 고로슬래그 미분말을 치환한 실험체(BRS시리즈), 순환골재와 고로슬래그의 치환율에 강섬유를 보강한 실험체(BSRS시리즈)로 총 11개의 실험체를 1/2축소 제작하여 실험을 수행하였다. 실험을 통하여 얻어진 결과를 비교 분석하여 하중-변위, 파괴형태, 최대내력 등을 규명함으로써 구조성능의 개선정도를 평가하였다. 실험 결과 순환골와 고로슬래그 미분말을 치환한 콘크리트에 강섬유를 보강한 실험체(BSRS시리즈)의 경우 표준실험체(BSS)보다 압축강도는 최대 9%, 최대내력은 1~6%, 연성능력은 각각 1.02~1.13배 증가하는 결과를 나타내었다. 또한, 충분한 연성적인 거동과 안정적인 휨인장 파괴를 나타내었다.

Flexural behaviour of reinforced low-strength concrete beams strengthened with CFRP plates

  • Boukhezar, Mohcene;Samai, Mohamed Laid;Mesbah, Habib Abdelhak;Houari, Hacene
    • Structural Engineering and Mechanics
    • /
    • 제47권6호
    • /
    • pp.819-838
    • /
    • 2013
  • This paper summarises the results of an experimental study to investigate the flexural behaviour of reinforced concrete beams strengthened using carbon-fibre reinforced polymer (CFRP) laminate in four-point bending. The experimental parameters included are the reinforcing bar ratio ${\rho}_s$ and preload level. Four bar ratios were selected (${\rho}_s=0.13$ to 0.86%), representing the section of two longitudinal tensile reinforcements, with diameters of 8, 14, 16, and 20 mm in order to reveal the effect of bar ratio on failure load and failure mode. Eight beams that could be considered "full-scale" in size, measuring 200 mm in width, 400 mm in total height and 2300 mm in length, were tested. Three beams were selected with different bar ratios (${\rho}_1$, ${\rho}_2$, ${\rho}_3$), and considered as control specimens (without ), while three other beams identical to the control beams with the same CFRP laminates ratio and a seventh beam with ${\rho}_{min}$ (the lowest bar ratio) were also used. In the second part of the study, two beams with the bar ratio ${\rho}_2$ were preloaded at two levels, 50 and 100% of their ultimate loads, and then repaired. This experimental investigation was consolidated using an analytical model. The experimental and analytical results indicate that the flexional capacity and stiffness of strengthened and repaired beams using CFRP laminate were increased compared to those of control beams, and the behaviour of repaired beams was nearly similar to the undamaged and strengthened beams; unlike the ductility of strengthened beams, which was greatly reduced compared to the control.

Studies on two bay and three storey infilled frame with different interface materials: Experimental and finite element studies

  • Muthukumar, S.;Satyanarayanan, K.S.;Senthil, K.
    • Structural Engineering and Mechanics
    • /
    • 제64권5호
    • /
    • pp.543-555
    • /
    • 2017
  • The non-linear behaviour of integral infilled frames (in which the infill and the frame are bonded together with help of various interface materials) is studied both experimentally and numerically. The experiments were carried out on one-sixth scale two-bay and three-storey reinforced concrete frames with and without infill against static cyclic loading. Three interface materials - cement mortar, cork and foam have been used in between the infill and the frame. The infill, interface and the frame are bonded together is called integral frame. The linear and non-linear behaviors of two dimensional bare frame and integral infilled frame have been studied numerically using the commercial finite element software SAP 2000. Linear finite element analysis has been carried out to quantify the effect of various interface materials on the infilled frames with various combinations of 21 cases and the results compared. The modified configuration that used all three interface materials offered better resistance above others. Therefore, the experiments were limited to this modified infilled frame case configuration, in addition to conventional (A1-integral infilled frame with cement mortar as interface) and bare frame (A0-No infill). The results have been compared with the numerical results done initially. It is found that stiffness of bare frame increased by infilling and the strength of modified frame increased by 20% compare to bare frame. The ductility ratio of modified infilled frame was 42% more than that of the conventional infilled frame. In general, the numerical result was found to be in good agreement with experimental results for initial crack load, ultimate load and deformed pattern of infill.

Seismic behavior investigation of the steel multi-story moment frames with steel plate shear walls

  • Mansouri, Iman;Arabzadeh, Ali;Farzampour, Alireza;Hu, Jong Wan
    • Steel and Composite Structures
    • /
    • 제37권1호
    • /
    • pp.91-98
    • /
    • 2020
  • Steel plate shear walls are recently used as efficient seismic lateral resisting systems. These lateral resistant structures are implemented to provide more strength, stiffness and ductility in limited space areas. In this study, the seismic behavior of the multi-story steel frames with steel plate shear walls are investigated for buildings with 4, 8, 12 and 16 stories using verified computational modeling platforms. Different number of steel moment bays with distinctive lengths are investigated to effectively determine the deflection amplification factor for low-rise and high-rise structures. Results showed that the dissipated energy in moment frames with steel plates are significantly related to the inside panel. It is shown that more than 50% of the dissipated energy under various ground motions is dissipated by the panel itself, and increasing the steel plate length leads to higher energy dissipation capability. The deflection amplification factor is studied in details for various verified parametric cases, and it is concluded that for a typical multi-story moment frame with steel plate shear walls, the amplification factor is 4.93 which is less than the recommended conservative values in the design codes. It is shown that the deflection amplification factor decreases if the height of the building increases, for which the frames with more than six stories would have less recommended deflection amplification factor. In addition, increasing the number of bays or decreasing the steel plate shear wall length leads to a reduction of the deflection amplification factor.

Experimental study on seismic behavior of exterior composite beam-to-column joints with large size stiffened angles

  • Wang, Peng;Wang, Zhan;Pan, Jianrong;Li, Bin;Wang, Bo
    • Steel and Composite Structures
    • /
    • 제37권1호
    • /
    • pp.15-26
    • /
    • 2020
  • The top-and-seat angles with double web angles are commonly used in the design of beam-to-column joints in Asian and North American countries. The seismic behavior analysis of these joints with large cross-section size of beam and column (often connected by four or more bolts) is a challenge due to the effects from the relatively larger size of stiffened angles and the composite action from the adjacent concrete slab. This paper presents an experimental investigation on the seismic performance of exterior composite beam-to-column joints with stiffened angles under cyclic loading. Four full-scale composite joints with different configuration (only one specimen contain top angle in concrete slab) were designed and tested. The joint specimens were designed by considering the effects of top angles, longitudinal reinforcement bars and arrangement of bolts. The behavior of the joints was carefully investigated, in terms of the failure modes, slippage, backbone curves, strength degradation, and energy dissipation abilities. It was found that the slippage between top-and-seat angles and beam flange, web angle and beam web led to a notable pinching effect, in addition, the ability of the energy dissipation was significantly reduced. The effect of anchored beams on the behavior of the joints was limited due to premature failure in concrete, the concrete slab that closes to the column flange and upper flange of beam plays an significant role when the joint subjected to the sagging moment. It is demonstrated that the ductility of the joints was significantly improved by the staggered bolts and welded longitudinal reinforcement bars.

Experimental seismic behaviour of L-CFST column to H-beam connections

  • Zhang, Wang;Chen, Zhihua;Xiong, Qingqing;Zhou, Ting;Rong, Xian;Du, Yansheng
    • Steel and Composite Structures
    • /
    • 제26권6호
    • /
    • pp.793-808
    • /
    • 2018
  • In this study, the seismic performance of the connections between L-shaped columns composed of concrete-filled steel tubes (L-CFST columns) and H-beams used in high-rise steel frame structures was investigated. Seven full-scale specimens were tested under quasi-static cyclic loading. The variables studied in the tests included the joint type, the axial compression ratio, the presence of concrete, the width-to-thickness ratio and the internal extension length of the side plates. The hysteretic response, strength degradation, stiffness degradation, ductility, plastic rotation capacity, energy dissipation capacity and the strain distribution were evaluated at different load cycles. The test results indicated that both the corner and exterior joint specimens failed due to local buckling and crack within the beam flange adjacent to the end of the side plates. However, the failure modes of the interior joint specimens primarily included local buckling and crack at the end plates and curved corners of the beam flange. A design method was proposed for the flexural capacity of the end plate connection in the interior joint. Good agreement was observed between the theoretical and test results of both the yield and ultimate flexural capacity of the end plate connection.

냉간가공된 316L 스테인리스 강의 인장 및 저주기 피로 물성치에 미치는 동적변형시효의 영향 (The Influence of Dynamic Strain Aging on Tensile and LCF Properties of Prior Cold Worked 316L Stainless Steel)

  • 홍성구;이순복
    • 대한기계학회논문집A
    • /
    • 제27권8호
    • /
    • pp.1398-1408
    • /
    • 2003
  • Tensile and LCF(low cycle fatigue) tests were carried out in air at wide temperature range 20$^{\circ}C$-750$^{\circ}C$ and strain rates of 1${\times}$10$\^$-4//s-1${\times}$10$\^$-2/ to ascertain the influence of strain rate on tensile and LCF properties of prior cold worked 316L stainless steel, especially focused on the DSA(dynamic strain aging) regime. Dynamic strain aging induced the change of tensile properties such as strength and ductility in the temperature region 250$^{\circ}C$-600$^{\circ}C$ and this temperature region well coincided with the negative strain rate sensitivity regime. Cyclic stress response at all test conditions was characterized by the initial hardening during a few cycles, followed by gradual softening until final failure. Temperature and strain rate dependence on cyclic softening behavior appears to result from the change of the cyclic plastic deformation mechanism and DSA effect. The DSA regimes between tensile and LCF loading conditions in terms of the negative strain rate sensitivity were well consistent with each other. The drastic reduction in fatigue resistance at elevated temperature was observed, and it was attributed to the effects of oxidation, creep and dynamic strain aging or interactions among them. Especially, in the DSA regime, dynamic strain aging accelerated the reduction of fatigue resistance by enhancing crack initiation and propagation.