• 제목/요약/키워드: strength and stability

검색결과 2,456건 처리시간 0.038초

깊은 풍화대 사면의 안정성 해석에서 물성치 산정 및 적용 (Application of Geotechnical Properties to the Slope Stability Analysis in Deep Weathered Zone)

  • 김경태;박시범;김창현;이종범;윤여원
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.768-776
    • /
    • 2006
  • Recently in spite of Development of Investigation machine, in Application of Geotechnical Properties by empirical recommendation to the Slope Stability Analysis. It is generally Application of convenience and conservative Geotechnical Properties by Borehole Shear Test(BST) in Representative Zone that Non-Division of Increase as the depth of Strength Parameters In Deep Weathered Zone. Therefore, it is become environment pollution and Non-Economical Slope Design to Application of convenience and conservative Geotechnical Properties. The production mechanism of Deep Weathered Zone is tend to Weathering Degree low and Strength increase by increase as the depth. it is realistic design that Division of Deep Weathered Zone and application Geotechnical Properties of Each Layer. In this Paper, Determined The Relationship of Strength Parameters between Standard Penetration Test(SPT), Borehole Shear Test(BST) and empirical recommendation also Applyed each strength parameters of divided zone to the Slope Stability Analysis by continuous Borehole Shear Test(BST) in Deep Weathered Zone during design of The 2nd Bridge Connection Road of Incheon International Airport.

  • PDF

STABILITY OF TUNNEL WORKING FACE IN SQUEEZING GROUND

  • 손근종;손준익
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1993년도 봄 학술회 논문집
    • /
    • pp.9-14
    • /
    • 1993
  • Practical solutions that are available today for assessing stability of tunnel working face are largely based on the concept of critical stability ratio. The accuracy of a prediction of the soil behavior in the working face, thus, depends on the ability of the solution to completely and accurately describe the stress fields or kinematics generated by the excavation and the accuracy of the undrained shear strength of the soil introduced in the computation. This paper reviews the selected solutions describing stability of the tunnel heading in squeezing ground, and suggests a reference solution which is established based on comparison of the solutions and field data on stability of tunnel headings in clays. Although dealing with the shear strength determination is an important companion part of the geotechnical prediction for stability of the tunnel heading in clays, this part is beyond the scope of this paper at this time.

  • PDF

마이크로파에 의한 모르터의 조기강조 추정기법에 관한 실험적 연구 (An Experimental Study on the Estimation Technique of Mortar Early Strength by Microwave)

  • 원준연;백민수;이종균;안형준;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.15-218
    • /
    • 1999
  • Concrete is the most generous, universal main structural material. There is active study for processing quality, stable quality mangement. Especially, strength is basic factor of evaluating stability of concrete building. Regaining required strength and homogeneity is very important to get self-stability in building to evaluate another characteristic. Concrete strength is important to the quality management. But, result of hardened concrete's quality test is hardly reflected to works immediately. When required strength is not enough, it could bring out safe problem, economic and administrative cost. It is pointed out that problems from strength evaluation, so early evaluation of concrete quality is required. From the trend that accelerating high quality concrete development, improving the method of quality test and early evaluation measure is urgent project. Throughout this report, it is suggested the method with use of microwave to evaluate 28-days concrete strength.

  • PDF

Strain-based stability analysis of locally loaded slopes under variable conditions

  • Wang, Jia-Chen;Zhu, Hong-Hu;Shi, Bin;Garg, Ankit
    • Geomechanics and Engineering
    • /
    • 제23권3호
    • /
    • pp.289-300
    • /
    • 2020
  • With the rapid development of the distributed strain sensing (DSS) technology, the strain becomes an alternative monitoring parameter to analyze slope stability conditions. Previous studies reveal that the horizontal strain measurements can be used to evaluate the deformation pattern and failure mechanism of soil slopes, but they fail to consider various influential factors. Regarding the horizontal strain as a key parameter, this study aims to investigate the stability condition of a locally loaded slope by adopting the variable-controlling method and conducting a strength reduction finite element analysis. The strain distributions and factors of safety in different conditions, such as slope ratio, soil strength parameters and loading locations, are investigated. The results demonstrate that the soil strain distribution is closely related to the slope stability condition. As the slope ratio increases, more tensile strains accumulate in the slope mass under surcharge loading. The cohesion and the friction angle of soil have exponential relationships with the strain parameters. They also display close relationships with the factors of safety. With an increasing distance from the slope edge to the loading position, the transition from slope instability to ultimate bearing capacity failure can be illustrated from the strain perspective.

마이크로파에 의한 PC접합모르타르의 조기강도추정에 관한 연구 (A Study on Early Strength Estimation of Precast Concrete joint Mortar with Microwave)

  • 원준연;박일용;백민수;이종균;안형준;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.217-222
    • /
    • 2000
  • A large Pc structure building is system that consisted of bearing wall and slab joint. It has general structure stability from unity thar each members tied at joint. The strength of mortar that packing in joint among panels is important to internal force in entire building system. Do, if we could get early strength estimation with microwave. It would bring good construction planning, reduce construction time, and judge building stability and so on. The purpose of this study is to develop early estimation method for making better quality control and constructing good PC panel structure. The results of this study were as follows :1) With sealed molds, reduced moisture volatilization to more than 60% and enlarged 30% accelerated compressive strength than before one. 2) To get more accelerated strength, we should control maximum temperature difference to $30^{\circ}C$ downward 3)Interrelation with 7-day and 28-day strength were 0.831,0.902, and it is above than before one

  • PDF

모직물의 접착심 접착에 의한 물성의 변화 (제2보) (changers of Mechanical Properties of Wool Woresed fabrics with fusible Interlingings(Part II))

  • 지주원;유효선;이대훈
    • 한국의류학회지
    • /
    • 제23권1호
    • /
    • pp.22-29
    • /
    • 1999
  • This paper descrived the changes of peel strength wrinkle recovery and dimensional stability after fusing 4 different wool face fabrics with 3 different fusible interlinings. The fusing condition was conducted by fusing press machine under 4kg.f/cm2 at 15$0^{\circ}C$. To determine the effect of the varous physical properties of the fused fabrics face fabrics and interlinings on the peel strength wrinkle recovery and dimensional stability(hygral expansion and relaxation shrinkage) of fused fabrics correlation among the KES values of fused fabrics face fabrics and interlinings to the peel strength rinkle recovery and dimensional stability of fused fabrics were expeerimentally analyzed,. As the results the peel strength was mainly influenced by the cover factor of face fabric and interlinings. After fusing wrinkle recovery and hygral expansion were decreased. The cover factor wrinkle recovery weight thickness shear rigidity and frictional properties of face fabric and the thickness of fused fabrics were not influence to the wrinkle recovery of fused fabrics. In addition the dimensional stabilities of fused fabrics were mainly influenced by the tensile and frictional properties of the wrinkle recovery of fused fabrics. In addition the dimensional stabilities of fused fabrics were mainly influenced by the tensile and frictional properties of the face fabrics.

  • PDF

다짐지반에 조성되는 굴착사면의 비등방성 전단강도를 고려한 안정성 분석 (Stability Analyses for Excavated Slopes Considering the Anisotropic Shear Strength of the Layered Compacted Ground)

  • 이병식;윤요진
    • 한국지반공학회논문집
    • /
    • 제18권5호
    • /
    • pp.27-35
    • /
    • 2002
  • 원 지반을 성토하여 인공적으로 형성된 다짐지반에 터파기를 하여 관을 매립하거나, 암거를 설치하는 작업을 수행 하는 경우가 자주 있다. 이 때 조성되는 임시굴착사면의 기울기를 적용함에 있어서 실험이나 사면안정해석 등의 적절한 과정을 수행하지 않음으로 인해 사면붕괴가 발생하여 인명 피해는 물론이고 공기의 지연 및 공사비의 증액 등 크고 작은 손실을 초래하고 있다. 본 논문에서는 이러한 임시사면의 안정성 검토를 위해 대표적인 경우들에 대한 사면안정해석을 수행하였으며, 특히 사면안정에 대한 다짐지반의 비등방성에 따른 전단강도의 영향을 검토하였다. 해석에서 적용한 다짐지반의 비등방성 전단강도는 전단면과 다짐층 간의 경사를 변화시키면서 수행한 일련의 직접전단시험으로부터 추정하였다. 해석 결과, 비등방성을 고려하는 지의 여부에 따라서 임시사면의 적절한 안정기울기가 소폭으로 변화할 가능성이 있음을 알았다. 그러나, 이에 따른 안전율의 변화나 파괴면의 양상은 그리 크게 변하지 않는 것으로 나타났다.

사면의 지반 열화로 인한 안정성 평가에 관한 연구 (A Study on the Evaluation of Stability due to Ground Deterioration of Slope)

  • 한영철
    • 한국지반공학회논문집
    • /
    • 제34권12호
    • /
    • pp.83-92
    • /
    • 2018
  • 사면 구조물은 시간이 경과함에 따라 대상지반에서 각종 열화 현상이 진행되어 내구성의 저하로 인한 붕괴가 발생할 수 있으며, 사용 연한을 감소시키는 결과를 초래하게 된다. 이러한 지반 열화에 따른 사면안정에 대한 접근방안은 지반의 물리적 특성 및 기하학적인 구조에 국한하여 분석하는 기존의 한계 평형 해석과는 또 다른 개념이라 할 수 있다. 본 연구에서는 사면의 열화 특성과 관련하여 각종 문헌 조사를 통하여 비교분석을 수행하고, 전단강도 저감에 대한 최적의 제안식들로서 지수함수, 로그함수 및 역쌍곡선 함수를 제시하고, 열화에 취약한 양산 단층대의 셰일층에서 붕괴가 발생한 경부고속철도 절토사면을 대상으로 사례분석을 실시하였다. 본 연구에서는 사례분석을 통하여 향후 열화로 인한 사면 안전성과 관련하여 정량적인 평가를 위한 최적의 강도 저하 곡선을 도출하고 한계평형해석에 의한 안정해석을 할 수 있는 접근 방법을 제시하였다.

Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems

  • Jo, Jae-Young;Yang, Dong-Seok;Huh, Jung-Bo;Heo, Jae-Chan;Yun, Mi-Jung;Jeong, Chang-Mo
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권6호
    • /
    • pp.491-497
    • /
    • 2014
  • PURPOSE. This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. MATERIALS AND METHODS. Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), commercially pure grade 4 titanium (group T4), or Ti-6Al-4V (group TA) (n=5, each). In order to assess the amount of settlement after abutment fixation, a 30-Ncm tightening torque was applied, then the change in length before and after tightening the abutment screw was measured, and the preload exerted was recorded. The compressive bending strength was measured under the ISO14801 conditions. In order to determine whether there were significant changes in settlement, preload, and compressive bending strength before and after abutment fixation depending on abutment materials, one-way ANOVA and Tukey's HSD post-hoc test was performed. RESULTS. Group TA exhibited the smallest mean change in the combined length of the implant and abutment before and after fixation, and no difference was observed between groups T3 and T4 (P>.05). Group TA exhibited the highest preload and compressive bending strength values, followed by T4, then T3 (P<.001). CONCLUSION. The abutment material can influence the stability of the interface in internal conical connection type implant systems. The strength of the abutment material was inversely correlated with settlement, and positively correlated with compressive bending strength. Preload was inversely proportional to the frictional coefficient of the abutment material.

긴급보수용 개질 유화아스팔트 고비율 순환골재를 사용한 상온 아스팔트 혼합물의 성능 평가 (Performance Evaluation of High-RAP Asphalt Mixtures using Rapid-Setting Polymer-Modified Asphalt Emulsion)

  • 권봉주;허재민;한용진;이석근
    • 한국도로학회논문집
    • /
    • 제17권2호
    • /
    • pp.21-30
    • /
    • 2015
  • PURPOSES : The purpose of this study was to evaluate the performance of rapid-setting polymer-modified asphalt mixtures with a high reclaimed asphalt pavement (RAP) content. METHODS: A literature review revealed that emulsified asphalt is actively used for cold-recycled pavement. First, two types of rapid-setting polymer-modified asphalt emulsion were prepared for application to high-RAP material with no virgin material content. The quick-setting polymer-modified asphalt mixtures using two types of rapid-setting polymer-modified asphalt emulsion were subjected to the following tests: 1) Marshall stability test, 2) water immersion stability test and 3) indirect tensile strength ratio test. RESULTS AND CONCLUSIONS : Additional re-calibration of the RAP was needed for laboratory verification because the results of analyzing RAP aggregates, which were collected from different job sites, did not deviate from the normal range. The Marshall stability of each type of binder under dry conditions was good. However, the Type B mixtures with bio-additives performed better in the water immersion stability test. Moreover, the overall results of the indirect tensile strength test of RAP mixtures with Type B emulsions exceeded 0.7. Further research, consisting of lab testing and on-site application, will be performed to verify the possibility of using RAP for minimizing the closing of roadways.