• Title/Summary/Keyword: stray current

Search Result 112, Processing Time 0.024 seconds

A New Measurement Method of the Ground Resistance Using a Low-pass Filter in Energized Substations (지역필터를 이용한 수변전실 접지저항의 새로운 측정방법)

  • Lee, Bok-Hui;Eom, Ju-Hong;Lee, Seung-Chil;Kim, Seong-Won;An, Chang-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.387-393
    • /
    • 2001
  • This paper describes an advanced measuring method and precise evaluation of the ground resistance for the grounding system of energized substations and power equipments. A grounding system of substations consists of all interconnected grounding connections of grounded conductors, neutral ground wires, underground conductors of distribution lines, cable shields, grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding system of high voltage energized substations because of harmonic components caused by switched power supplies or overloads. The conventional fall-of-potential method may be subject to big error if stray ground currents and potentials are present. In this work, to improve the precision in measurements of the ground resistance by eliminating the effects of harmonic components and stray currents and potentials, the investigations of the ground resistance measurement by using a low pass filter in a model energized grounding system were conducted. The accuracy of ground resistance mesurements was evaluated as a function of the ratio of the test signal to noise (S/N). The errors due to the proposed ground resistance measurement method were decreased with increasing S/N and were less than 5[%] as S/N is 10. The proposed ground resistance measurement method appears to be considerably more accurate than the conventional fall-of -potential method. It is allows cancellation of the parasitic resistance of energized grounding systems, to employ the measurement method that allows cancellation of the parasitic effects due to other circulating ground currents and ground potential rises in practical situations.

  • PDF

Design and Development of a Single-photon Laser and Infrared Common Aperture Optical System

  • Wu, Hongbo;Zhang, Xin;Tan, Shuanglong;Liu, Mingxin;Wang, Lingjie;Yan, Lei;Liu, Yang;Shi, Guangwei
    • Current Optics and Photonics
    • /
    • v.6 no.2
    • /
    • pp.171-182
    • /
    • 2022
  • A single-photon laser and mid-wave infrared (MWIR) common aperture optical system was designed and developed to detect and range a long-distance civil aviation aircraft. The secondary mirror of the Ritchey-Chretien (R-C) optical system was chosen as a dichroic lens to realize the design of a common aperture system for the laser and MWIR. Point spread function (PSF) ellipticity was introduced to evaluate the coupling efficiency of the laser receiving system. A small aperture stop and narrow filter were set in the secondary image plane and an afocal light path of the laser system, respectively, and the stray light suppression ability of the small aperture stop was verified by modeling and simulation. With high-precision manufacturing technology by single point diamond turning (SPDT) and a high-efficiency dichroic coating, the laser/MWIR common aperture optical system with a 𝜑300 mm aluminum alloy mirror obtained images of buildings at a distance of 5 km with great quality. A civil aviation aircraft detection experiment was conducted. The results show that the common aperture system could detect and track long-distance civil aviation aircraft effectively, and the coverage was more than 450 km (signal-to-noise ratio = 6.3). It satisfied the application requirements for earlier warning and ranging of long-range targets in the area of aviation, aerospace and ground detection systems.

A Study on the Reduction of high frequency leakage current in PWM inverter fed Induction Motor (PWM 인버터로 구동된 유도전동기의 누설전류 억제에 관한 연구(II) -능동형 커먼 모드 전압 감쇄기를 이용한 고주파 누설전류 억제-)

  • 성병모;류도형;박성준;김철우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.5
    • /
    • pp.443-450
    • /
    • 2000
  • A PWM inverter for an induction motor often has a problem with a high frequency leakage current that flows through stray capacitors between stator windings and a motor frame to ground. This paper proposes a new type of Active Common Mode Voltage Canceler circuit for the reduction of common mode voltage and high frequency leakage current generated by the PWM VSI-fed induction motor drives. The compensating voltage applied by the common made voltage canceler has the same amplitude as, hut the opposite polarity to, the common mode voltage by PWM Inverter. Therefore, common mode voltage and high frequency leakage current can be canceled. The proposed circuit consists of four-level half-bridge inverter and common-mode transformer. Simulated and experimental results show that common mode voltage canceler makes significant contributions to reducing a high frequency leakage current.

  • PDF

A Compact and Fast Measurement System for the Detection of Small Capacitance

  • Youngshin Woo;Sung, Man-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • v.2 no.1
    • /
    • pp.16-21
    • /
    • 2001
  • A new technique to measure low level capacitance variations of a gyroscope is proposed. It is based on the improved CVC(capacitance to voltage converter) biased by a d.c. current source and the peak detector without any low pass filter. This setup of the measurement system makes it possible to provide higher speed of measurement and wide operation range. The d,c, drift of the conventional CVC and stray capacitances are automatically compensated. Key parameters that affect the performance of the measurement system are illustrated and computer simulation results are presented. The demonstrated measurement system for micromachined gyroscope applications shows a linearity of 0.99972 and a resolution of 0.67fF from 10 fF to 120 fF at 10 kHz.

  • PDF

A Novel Flexible PCB Conductive Structure for Electrodynamic Bearings and Measurement in its Induced Voltage

  • Ding, Guoping;Sandtner, Jan;Bleuler, Hannes
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2001-2008
    • /
    • 2015
  • This paper proposes the concept of FlexPCB(flexible Printed Circuit Board) conductive structure for electrodynamic bearings. It has three main advantages: easy “printing” of considerably thin conductive wires, resulting in potential reduction in stray eddy currents; realization of specific conductive configurations with high precision to optimize the eddy current flowing; simplicity in being wound to cylinders or hollow cylinders of different diameters. To verify this new concept, the FlexPCB conductive structure was manufactured, an axial electrodynamic bearing test rig was built and the conductive structure's induced voltage was measured along the axial displacements from 0mm to 56mm at three rotating speeds. The finite element method was used to calcuatlate the flux density of electrodynamic bearing and induced voltage of the FlexPCB conductive structure. The experimental results are compared with the results from the FEM calculation. It is concluded that the measured and calculated induced voltages have consistency in the middle part of the bearing.

A New GTO Driving Technique for Faster Switching (고속 스윗징을 위한 새로운 GTO 구동기법)

  • Kim, Young-Seok;Seo, Beom-Seok;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.2
    • /
    • pp.244-250
    • /
    • 1994
  • This paper presents the design of a new turn-off gate drive circuit for GTO which can accomplish faster turn-off switching. The major disadvantage of the conventional turn-off gate drive technique is that it has a difficulty in realizing high negative diS1GQT/dt because of VS1RGM(maximum reverse gate voltage) and stray inductances of turn-off gate drive circuit[1~2]. The new trun-off gate drive technique can overcome this problem by adding another turn-off gate drive circuit to the conventional turn-off gate drive circuit. Simulation and experimental results of the new turn-off gate drive circuit in conjunction with chopper circuit verify a faster turn-off switching performance.

  • PDF

A Study on the Multiple CCFL Operation and Brightness Improvement (다수의 CCFL 구동과 휘도 향상에 관한 연구)

  • Park, Jung-Oh;Kim, Cherl-Jin;Park, Hyun-Cherl
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.126-128
    • /
    • 2008
  • This paper presents an architecture for driving multiple paralleled cold cathode fluorescent lamps (CCFLs) for back lighting applications. Multi CCFL operation and increase of brightness, the key to the architecture is a proposed capacitive coupling approach for lamp ignition. This system is consist of a flyback converter, a single inverter to drive multiple lamps and conductive floating reflector. The topology is capable of driving a number of parallel lamps with independent accurate lamp, The capacitive coupling the leakage inductance and stray capacitance creation which it used, current regulation and improving cost effectiveness with significant reduction in size and weight, compared to typical high frequency ac ballast. Experimental demonstration results for ten of parallel CCFLs with simultaneous ignition.

  • PDF

Switching behavior in Peramlloy/Niobium/Permalloy trilayer

  • Hwang, Tae-Jong;Kim, Dong Ho
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.4
    • /
    • pp.17-20
    • /
    • 2014
  • We have investigated the effect of temperature and bias current on the stability of the inverse spin-switch effect in Permalloy(Py)/Nb/Permalloy pseudo spin-valves. The inverse spin-switch operates between two orientations of the ferromagnetic moments of Py layers; parallel (ON) and antiparallel-domain (OFF) state. Measuring time scans of the resistance changes between the ON and OFF state, ${\Delta}R_{ON-OFF}$, while alternating magnetic fields between the two states at various temperatures and bias currents, revealed that enhancement of ${\Delta}R_{ON-OFF}$ is a key factor to achieve successful operation of superconducting spin switch.

Voltage Application Indicator Using Liquid Crystal Device (LCD를 이용한 통전상태 표시기 개발)

  • Koo, K.W.;Lyu, S.H.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1757-1759
    • /
    • 2000
  • To make a inspection and maintenance of the high voltage equipment, electric machinery to transmit and distribute the electric power, the appearance of a simple and inexpensive indicator with which the charge condition of bare conductor parts could be read at a Stance has been needed. Liquid crystal has recently been expanding its application rapidly in appliances for everyday use. Since its display energy is extremely small, it is possible to obtain the working current with simple condenser voltage divider that makes use of stray capacity when it is applied to electric power equipment. Thus, an apparatus has finally appeared which is close to the one they have sought and indicates the existence of voltage impressions.

  • PDF

고속 광통신용 GaInAs/InP PIN 수광소자 모듈 제작

  • Park, Chan-Yong;Park, Kyung-Hyun;Lee, Chang-Won;Lee, Yong-Tak
    • ETRI Journal
    • /
    • v.13 no.4
    • /
    • pp.52-57
    • /
    • 1991
  • We fabricated very high. speed PIN Photodiode module for the application of high speed optical receiver. OMVPE was used for the growth of InP layer on InGaAs absorption layer. The structure was the combination of mesa and planartype. Fabrication procedure was more complicated than simple mesa or simple planar type structure because we used semiinsulating InP substrate in order to reduce stray capacitance. The results at-5V were as follows : dark current was less than 1nA, capacitance was 0.55pF, and cutoff frequency was above 3GHz, and rise and fall time was about 100ps.