• 제목/요약/키워드: strain sensitivity

검색결과 657건 처리시간 0.029초

Strain monitoring of reinforced concrete with OTDR-based FBG interrogation technique

  • Dyshlyuk, Anton V.;Makarova, Natalia V.;Vitrik, Oleg B.;Kulchin, Yuri N.;Babin, Sergey A.
    • Smart Structures and Systems
    • /
    • 제20권3호
    • /
    • pp.343-350
    • /
    • 2017
  • An experimental study is presented of the application of fiber Bragg grating (FBG) interrogation method based on optical time-domain reflectometery (OTDR) to monitoring strain in bent reinforced concrete beams. The results obtained with the OTDR-based method are shown to agree well with the direct spectral measurements. Strain sensitivity, resolution and measurement range amounted to $0.0028dB/{\mu}strain$; $30{\mu}strain$; $4000{\mu}strain$, correspondingly. Significant differences are observed in surface and inner deformations of the test beams which can be attributed to different mechanical properties of concrete and steel reinforcement. The prospects of using OTDR-based FBG interrogation technique in real-life applications are discussed.

Back-Face Strain Compliance Calibration for the Four-Point Bend Specimen

  • Huh, Yong-Hak;Song, Ji-Ho
    • Journal of Mechanical Science and Technology
    • /
    • 제14권3호
    • /
    • pp.314-319
    • /
    • 2000
  • Back-face strain compliance (BFS compliance) for the four-point bend specimen has been calibrated for various crack length ratios. Finite element technique was employed to simulate four-point loading and calculate back-face strain of the bend specimen. The numerically determined strain variation along the back face indicates that the sensitivity to gage placement increases with crack length and back-face strain at the gage length less than O.2W, where W is the width of the bend specimen, can be measured within 5% deviation of the maximum BFS. Non-dimensional back-face strain compliance, -E'BCW, was calibrated with FE analysis and experiment. The experimentally determined compliance indicates good agreement with the numerical compliance and can be expressed as a function of crack length ratio.

  • PDF

변형률속도와 온도에 따른 SPF8090 Al-Li 초소성 재료의 물성 특성 (Characterization of superplastic material SPF8090 AI-Li with the variation of the strain rate and the temperature)

  • 이기석;허훈
    • 소성∙가공
    • /
    • 제6권5호
    • /
    • pp.425-434
    • /
    • 1997
  • A superplastic material, aluminum-lithium alloy 8090, was examined with uniaxial tensile tests to investigate its thermomechanical behavior. The tests were carried out at the strain rate ranging from $2X10^4 to 1X10^2$ and at the temperature from 48$0^{\circ}C$ to 54$0^{\circ}C$. The experiments produced force-dis-placement curves which were converted to stress-strain curves. From the curves, the optimum conditions of superplastic forming were obtained by deteriming the strain rate sensitivety, the optimum strain rate, and the strength coefficient for various forming temperatures.

  • PDF

Localized failure in damage dynamics

  • Do, Xuan Nam;Ibrahimbegovic, Adnan;Brancherie, Delphine
    • Coupled systems mechanics
    • /
    • 제4권3호
    • /
    • pp.211-235
    • /
    • 2015
  • In this work we present a one-dimensional damage model capable of representing the dynamic fracture for elastodamage bar with combined hardening in fracture process zone - FPZ and softening with embedded strong discontinuities. This model is compared with another one we recently introduced (Do et al. 2015) and it shows a good agreement between two models. Namely, it is indicated that strain-softening leads to a sensitivity of results on the mesh discretization. Strain tends to localization in a single element which is the smallest possible area in the finite element simulations. The strain-softening element in the middle of the bar undergoes intense deformation. Strain increases with increasing mesh refinement. Strain in elements outside the strain-softening element gradually decreases to zero.

Development of strain-specific polymerase chain reaction primers to detect Fusobacterium hwasookii strains

  • Lim, Yun Kyong;Kook, Joong-Ki
    • International Journal of Oral Biology
    • /
    • 제46권4호
    • /
    • pp.155-159
    • /
    • 2021
  • This study aimed to develop strain-specific polymerase chain reaction (PCR) primers to detect Fusobacterium hwasookii KCOM 1249T, F. hwasookii KCOM 1253, F. hwasookii KCOM 1256, F. hwasookii KCOM 1258, and F. hwasookii KCOM 1268 on the basis of nucleotide sequences of a gene specific to each strain. The unique genes for each F. hwasookii strain were determined on the basis of their genome sequences using Roary. The strain-specific PCR primers based on each strain-specific gene were designed using PrimerSelect. The specificity of each PCR primer was determined using the genomic DNA of the 5 F. hwasookii strains and 25 strains of oral bacterial species. The detection limit and sensitivity of each strain-specific PCR primer pair were determined using the genomic DNA of each target strain. The results showed that the strain-specific PCR primers correspond to F. hwasookii KCOM 1249T, F. hwasookii KCOM 1253, F. hwasookii KCOM 1258, F. hwasookii KCOM 1256/F. nucleatum subsp. polymorphum KCOM 1260, or F. hwasookii KCOM 1268/Fusobacterium sp. oral taxon 203 were developed. The detection limits of these strain-specific PCR primers ranged from 0.2 to 2 ng of genomic DNA for each target strain. The results suggest that these strain-specific PCR primers are valuable in quality control for detecting specific F. hwasookii strains.

Microbial isolates and antibiotic sensitivity in patients hospitalized with odontogenic infections at a tertiary center over 10 years

  • Gyu-Beom Kwon;Chul-Hwan Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제49권4호
    • /
    • pp.198-207
    • /
    • 2023
  • Objectives: This study investigated causative strains and their antibiotic sensitivity in patients who were hospitalized for maxillofacial odontogenic infections at a tertiary center in South Korea over the past 10 years with the aim of providing guidelines for the selection of appropriate empirical antibiotics. Materials and Methods: Patients with head and neck fascial space abscesses due to odontogenic infections who underwent incision and drainage surgery with pus culture tests between 2013 and 2022 at the Department of Oral and Maxillofacial Surgery, Dankook University Hospital were included. The bacterial isolates and antibiotic sensitivity of each strain were analyzed for 2013-2022, 2013-2017, and 2018-2022. The affected fascial spaces were classified into primary, secondary, and deep neck spaces. Results: In the 192 patients included in this study, 302 strains were detected. Viridans streptococcus had the highest frequency (51.7%), followed by Prevotella spp. (16.9%), Staphylococcus spp. (5.6%), and Klebsiella pneumoniae (4.6%). The identification rate of viridans streptococcus significantly increased from 41.8% in 2013-2017 to 60.9% in 2018-2022. Viridans streptococcus showed an antibiotic sensitivity of 80.5% to ampicillin; the sensitivity to penicillin antibiotics decreased over the study period. Antibiotic susceptibility was approximately 94% for third-generation cephalosporins. K. pneumoniae, which was identified at a high percentage in patients with deep neck space infection, showed increasing antibiotic resistance to most antibiotics over the study period. Conclusion: Viridans streptococcus was identified in head and neck fascial space abscesses with the highest frequency. Empirical antibiotics should be effective against this strain; penicillin antibiotics are considered inappropriate. For effective treatment of deep neck space abscesses, bacterial culture and antibiotic sensitivity tests performed as soon as possible are essential.

Dynamic Strain Aging on the Leak-Before-Break Analysis in SA106 Gr.C Piping Steel

  • Kim, Jin-Weon;Kim, In-Sup
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(3)
    • /
    • pp.193-198
    • /
    • 1996
  • The effect of dynamic strain aging (DSA) on the leak-before-break (LBB) analysis was estimated through the evaluation of leakage-size-crack and flaw stability in SA106 Gr.C piping steel. Also. the results were represented as a form of "LBB allowable load window". In the DSA temperature region. the leakage-size-crack length was smaller than that at other temperatures and it increased with increasing tensile strain rate. In the results of flaw stability analysis. the lowest instability load appeared at the temperature corresponding to minimum J- R curve which was caused by DSA. The instability load near the plant operating temperature depended on the loading rate of J-R data. and decreased with increasing tensile strain rate. These are due to the strain hardening characteristic and strain rate sensitivity of DSA. In the "LBB allowable load window". LBB allowable region was the narrowest at the temperature and loading conditions where DSA occurs.

  • PDF

후막저항의 기하학적 위치에 따른 압력센서의 출력특성 고찰 (A Study of Deflection of Ceramic Diaphragm for a Pressure Sensor)

  • 이성재;이득용;하영선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.884-887
    • /
    • 2003
  • Strain gages were widely used transducers. Essentially a strain gage was an electric element to which an appropriate type was attached. Strain was sensed by gages and provided electrical output proportional to applied forced. This paper describes the recent development of a thick film strain gage ceramic pressure sensors. The thick film resistors as strain gage in the Wheatstone bridge were fabricated with a novel mixture of ruthenium. The thick-film technology of resistors were printed on the ceramic diaphragm back side by screen printing and cured at $850^{\circ}C$. The mechanical measurements were performed with the computer simulation results(ANSYS 5.1). The output sensitivity was 1.2mV/V, of which max. nonlinearity was less than 0.29%, hysteresis was less than 0.38%FS.

  • PDF

FBG 센서를 활용한 온도와 스트레인 변화 모니터링 (Monitoring of Temperature and Strain Variation with FBG Sensors)

  • 고기한;박영;조용현;정호성;조용석;최원석
    • 한국전기전자재료학회논문지
    • /
    • 제22권3호
    • /
    • pp.218-221
    • /
    • 2009
  • This paper reports on measurement method for the fiber optic strain monitoring of overhead contact line systems of trains, We used FBG (Fiber Bragg Grating) sensors to measure the strain variation of overhead contact line. FBG sensors can sensitively measure the variation of strain and! or temperature by the shift wavelength of reflected wave according to the lattice variation during the measurement. FBG sensor were attached on the contact line and connected to the monitoring system with optical fibers. The monitering system with FBG sensors showed very good sensitivity to measuring strain variation and this system could be applied to the overhead contact line of KTX (Korea Train eXpress).

식품 첨가물이 Listeria monocytogenes H-12의 내열성에 미치는 영향 및 오염된 조리기구 제균 (Effect of Food Additives on Heat Sensitivity of Listeria monocytogenes H-12 and Decontamination of Kitchen Utensils)

  • 이희정;이태식;손광태;변한석;김지회;박정흠;박미정
    • 한국수산과학회지
    • /
    • 제33권6호
    • /
    • pp.524-528
    • /
    • 2000
  • 식품중에 오염된 Listeria monocytogenes의 열감수성에 미치는 각종 첨가물의 영향과 식품의 처리 가공시에 수반되는 조리기구 수세나 염소, 자외선, 열탕 등 각종 소독처리의 효율성을 확인하였다. 키토산, 솔빈산칼륨 둥은 시험균주 L. monocytogenes H-12의 열 감수성 증대에 유의할 만한 영향을 미치지 못하였으나, 명태 연육에 중합인산염을 $1{\%}$ 첨가할 경우 시험균주의 열감수성은 뚜렷히 증가되었다. 시험균주 L. monocytogenes H-12가 $약 10^4{\~}10^5/cm^2$ 되도록 오염시킨 나무, 플라스틱, 스테인레스 재질의 도마를 흐르는 수도수로 세척하였을 때 스테인레스 도마나 플라스틱 도마의 경우 각각 10초 및 1분 후에는 균이 검출되지 않았으나, 나무 도마에서는 거의 제균효과가 없었다. 스테인레스 및 플라스틱 재질의 도마를 $5{\~}50 ppm$의 염소용액에 10초간 침지하고 수세할 경우 오염균의 제거가 가능하였으나, 나무 도마의 경우 100ppm 염소용액으로 처리하여도 균 수의 감소는 거의 없었다. 15W의 자외선을 30cm 거리에서 시험균주로 오염된 각 재질의 도마에 조사할 경우 스테인레스 및 플라스틱 도마의 경우 5분간 조사 후에는 균이 검출되지 않았으나, 나무 도마에서는 60분 처리 후에도 균이 검출되었다. 각종재질의 조리용 도마에 오염된 시험균주 L. monocytogenes H-12의 열탕처리에 의한 제균조건은 $70^{\circ}C$, 10초 이상으로 확인되었다.

  • PDF