A Study of Deflection of Ceramic Diaphragm for a Pressure Sensor

후막저항의 기하학적 위치에 따른 압력센서의 출력특성 고찰

  • Published : 2003.07.10

Abstract

Strain gages were widely used transducers. Essentially a strain gage was an electric element to which an appropriate type was attached. Strain was sensed by gages and provided electrical output proportional to applied forced. This paper describes the recent development of a thick film strain gage ceramic pressure sensors. The thick film resistors as strain gage in the Wheatstone bridge were fabricated with a novel mixture of ruthenium. The thick-film technology of resistors were printed on the ceramic diaphragm back side by screen printing and cured at $850^{\circ}C$. The mechanical measurements were performed with the computer simulation results(ANSYS 5.1). The output sensitivity was 1.2mV/V, of which max. nonlinearity was less than 0.29%, hysteresis was less than 0.38%FS.

Keywords