• Title/Summary/Keyword: strain gauges

Search Result 365, Processing Time 0.022 seconds

Instrumentations for the Behaviour Observation of the Geotextile on Marine Clayey Grounds (해성점토지반에 설치된 지오텍스타일의 거동 관측을 위한 계측)

  • 조성민;장용채
    • Journal of Korean Port Research
    • /
    • v.14 no.4
    • /
    • pp.463-473
    • /
    • 2000
  • Reinforcement with geotextiles have been used in the foundation soil to enhance the resistance of embankments to avoid failure through excessive deformation or shear in the foundation. It is improtant to know the amount of the strain and the displacement of buried geotextiles for the verification of the reinforcement behaviour. Full scale trial constructions were performed to check the deformational characteristics of the polyester(PET) mat which was used for the embankment reinforcement. Many instrumentation equipments including surface settlement plates, profile gauges and inclinometer casings were installed to observe the behaviour of the soft ground due to the soil embankment. 60 electrical resistance strain gauges and 9 vibrating wire LVDTs were installed 세 measure the deformation of the polyester mat. Results of various tests and geotextile, waterproofing and protection from the hazard environments were introduced. The proposed instrumentation method was effective for the monitoring or the geotextile behaviour. The direct attachment of electrical resistance strain gauges on the gertextile mat was able to measure small changes of the strain of geotextiles. At the end of the 5 month monitoring, 54 of 60 (93%) strain gauges and 7 of 9 (78%) displacement transducers survived all perils of the compaction impacts and the humidity. And the tensile strain of grotextiles increased as the ground displacement became larger. Though the observed strain of mats under the 3m high embankment load was less than 1%, the magnitudes of the strain according to the mat spreading method were different from each other.

  • PDF

Spray-coated single-wall carbon nanotube film strain sensor (스프레이코팅 방식으로 제작된 단일벽 탄소나노튜브막 스트레인센서)

  • Park, Chan-Won
    • Journal of Industrial Technology
    • /
    • v.32 no.A
    • /
    • pp.29-33
    • /
    • 2012
  • We demonstrated the viability of fully microfabricating SWCNT(single-wall carbon nanotube) film strain sensors for force and weight sensing. Our spray-deposited SWCNT film strain sensors showed good linearity over a range from 0 to 400 microstrain, and much higher sensitivity compared to commercial metal foil-type gauges. The number of grids and the thickness of the SWCNT film were found to have a significant effect on the strain sensing properties of the SWCNT film gauges. A strain sensing methode for the CNT-based strain gauges was also investigated using a binocular type beam load cells. Preliminary results indicate that the microfabrication method shown here is promising for developing a commercial strain gauge using a spray-coated SWCNT thin film. In the near future, various studies will be performed to further enhance the properties of the spray-coated SWCNT film strain sensors.

  • PDF

Parametric Study about Measuring Train Loads (열차하중 측정에 관한 매개변수 연구)

  • Lee So-Jin;Oh Ji-Taek;Park Ok-Jeoung
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1148-1154
    • /
    • 2004
  • Parametric studies are executed by numerical method varying then number of strain gauges, rail section and distance of sleeper from which the followings are obtained. Wheel forces or lateral forces are measured by connecting eight strain gauges on rail to single Wheatstone bridge. The method eliminates the influence of interaction and measured stability. Strain gauges are fastened on the neutral axis of the rail so as not to be influenced by sleeper.

  • PDF

The Fabrication of Chromiun Thin-Film Strain Gauges and Its Characteristics (크롬박막 스트레인 게이지의 제작과 그 특성)

  • 김정훈;정귀상
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.343-346
    • /
    • 1997
  • This paper presents the basic characteristics of Cr thin-film, which were deposited on glass by DC magnetron sputtering. The optimized deposition condition of Cr thin-film strain gauges were input power 7w/cm$^2$and the Ar working pressure was 9mtorr. GF(Gauge Factor), TCR(Temperature Coefficient of Resistance) and TCS(Temperature Coefficient of Sensitivity) of Cr thin-film strain gauges were 5.86, 400 ppm/$^{\circ}C$ and 0 ppm/$^{\circ}C$, respectively.

  • PDF

Diaphragm-Type Pressure Sensor with Cu-Ni Thin Film Strain Gauges-I: Development of Cu-Ni Thin Film Strain Gauges (Cu-Ni 박막 스트레인 게이지를 이용한 다이어프램식 압력 센서-I: Cu-Ni 박막 스트레인 게이지 개발)

  • 민남기;이성래;김정완;조원기
    • Electrical & Electronic Materials
    • /
    • v.10 no.9
    • /
    • pp.938-944
    • /
    • 1997
  • Cu-Ni thin film strain gauges for diaphragm-type pressure sensors were developed. Thin films of Cu-Ni alloys of various compositions were deposited onto glass and stainless steel substrates by RF magnetron sputtering. The effects of composition substrate temperature Ar partial pressure and aging on the electrical properties of Cu-Ni film strain gauges in the thickness range 500~2000$\AA$ are discussed. The maximum resistivity(95.6 $\mu$$\Omega$cm) is obtained from 53wt%Cu-47wt%Ni films while the temperature coefficient of resistance(TCR) becomes minimum(25.6ppm/$^{\circ}C$). The gauge factor is about 1.9.

  • PDF

Optimal Placement of Strain Gauge for Vibration Measurement for Fan Blade (블레이드 진동측정을 위한 스트레인 게이지 설치위치 최적화)

  • Choi ByeongKeun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.9 s.90
    • /
    • pp.819-826
    • /
    • 2004
  • A multi-step optimum strategy for the selection of the locations and directions of strain gauges is proposed in this paper to capture at best the modal response of blade in a series of modes on fan blades. It is consist of three steps including two pass reduction step, genetic algorithm and fine optimization to find the locations-directions of strain gauges. The optimization is based upon the maximum signal-to-noise ratio(SNR) of measured strain values with respect to the inherent system measurement noise, the mispositioning of the gauge in location and gauge failure. Optimal gauge positions for a fan blade is analyzed to prove the effectiveness of the multi-step optimum methodology and to investigate the effects of the considering parameters such as the mispositioning level, the probability of gauge failure, and the number of gauges on the optimal strain gauge position.

Characteristics of Chromiun Nitride Thin-film Strain Guges (크로질화박막 스트레인 게이지의 특성)

  • Chung, Gwiy-Sang;Kim, Gil-Jung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04b
    • /
    • pp.134-138
    • /
    • 2000
  • The physical, electrical and piezoresitive characteristics of CrN(chromiun nitride) thin-films on silicon substrates have been investigated for use as strain gauges. The thin-film depositions have been carried out by DC reactive magnetron sputtering in an argon-nitrogen atmosphere(Ar-(5~25 %)$N_2$). The deposited CrN thin-films with thickness of $3500{\AA}$nd annealing conditions($300^{\circ}C$, 48 hr) in Ar-10 % $N_2$ deposition atmosphere have been selected as the ideal piezoresistive material for the strain gauges. Under optimum conditions, the CrN thin-films for the strain gauges is obtained a high electrical resistivity, $\rho=1147.65\;{\mu}{\Omega}cm$, a low temperature coefficient of resistance, TCR=-186 ppm/$^{\circ}C$ and a high temporal stability with a good longitudinal gauge factor, GF=11.17.

  • PDF

Fabrication of Tantalum Nitride Thin-Film as High-temperature Strain Gauges (고온 스트레인 게이지용 질화탄탈박막의 제작)

  • 최성규;나경일;남효덕;정귀상
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.1022-1025
    • /
    • 2001
  • This paper presents the characteristics of TaN thin-film as high-temperature strain gauges, which were deposited on Si substrate by DC reactive magnetron sputtering in an argon-nitrogen atmosphere(Ar-(4∼20%)N$_2$). The electrical and mechanical characteristics of these films investigated with the thickness range 1650∼1870${\AA}$ and room temperature resistivities in the range 178.3 ${\mu}$$\Omega$cm to 3175.7 ${\mu}$$\Omega$cm. The TaN thin-film strain gauge deposited in Ar-(20%)N$_2$atmosphere is obtained a temperature coefficient of resistance(TCR), 0∼-1357 ppm/$^{\circ}C$ in the temperature range 25∼275$^{\circ}C$ and a high temporal stability with a longitudinal gauge factor, 2.92∼3.47. Because of their high resistivity, low TCR and linear gauge factor, these cermet thin-film may allow high-temperature strain gauges miniaturization.

  • PDF

Fabrication of High-sensitivity Thin-film Type Strain-guges (고감도 박막형 스트레인 게이지의 제작)

  • Chung, Gwiy-Sang;Seo, Jeong-Hwan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.135-141
    • /
    • 2000
  • The physical, electrical and piezoresitive characteristics of CrN(chromiun nitride) thin-films on silicon substrates have been investigated for use as strain gauges. The thin-film depositions have been carried out by OC reactive magnetron sputtering in an argon-nitrogen atmosphere(Ar-(5~25 %)$N_2$). The deposited CrN thin-films with thickness of $3500{\AA}$ and annealing conditions($300^{\circ}C$, 48 hr) in Ar-10 % $N_2$ deposition atmosphere have been selected as the ideal piezoresistive material for the strain gauges. Under optimum conditions, the CrN thin-films for the strain gauges is obtained a high electrical resistivity, $\rho=1147.65\;{\mu}{\Omega}cm$, a low temperature coefficient of resistance, TCR=-186 ppm/$^{\circ}C$ and a high temporal stability with a good longitudinal gauge factor, GF=11.17.

  • PDF

Bridge deflection evaluation using strain and rotation measurements

  • Sousa, Helder;Cavadas, Filipe;Henriques, Abel;Bento, Joao;Figueiras, Joaquim
    • Smart Structures and Systems
    • /
    • v.11 no.4
    • /
    • pp.365-386
    • /
    • 2013
  • Monitoring systems currently applied to concrete bridges include strain gauges, inclinometers, accelerometers and displacement transducers. In general, vertical displacements are one of the parameters that more often need to be assessed because their information reflects the overall response of the bridge span. However, the implementation of systems to continuously and directly observe vertical displacements is known to be difficult. On the other hand, strain gauges and inclinometers are easier to install, but their measurements provide no more than indirect information regarding the bridge deflection. In this context, taking advantage of the information collected through strain gauges and inclinometers, and the processing capabilities of current computers, a procedure to evaluate bridge girder deflections based on polynomial functions is presented. The procedure has been implemented in an existing software system - MENSUSMONITOR -, improving the flexibility in the data handling and enabling faster data processing by means of real time visualization capabilities. Benefiting from these features, a comprehensive analysis aiming at assessing the suitability of polynomial functions as an approximate solution for deflection curves, is presented. The effect of boundary conditions and the influence of the order of the polynomial functions on the accuracy of results are discussed. Some recommendations for further instrumentation plans are provided based on the results of the present analysis. This work is supported throughout by monitoring data collected from a laboratory beam model and two full-scale bridges.