Characterization of Stormwater Runoff according to Sewer System in Paldang Watershed (하수도 시스템 유무에 따른 강우유출특성 분석 - 팔당호 유역을 대상으로)

  • Kang, Dong-Han;Sajjad, Raja Umer;Kim, Keuktae;Lee, Chang-Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.2
    • /
    • pp.142-148
    • /
    • 2016
  • The characterization of stormwater runoff from mix land-use catchments with an inadequate sewer network is a challenge. This study focused on characterizing stormwater runoff from the Paldang watershed area based on land-use type and sewer system coverage. A total of 76 sites were monitored during wet weather from seven different counties within Paldang watershed. Public sewer system (PSS) was installed at 48 sites, while 28 sites had no or individual sewer system (ISS) coverage. The results indicated that the sites included in the ISS group with higher forest and paddy land-use percentage exhibit higher values of average event mean concentrations (EMCs) and first flush intensity for suspended solids (SS), total nitrogen (TN), and total phosphorous (TP). In addition, upgrading runoff interception system can capture 59 % of the TP load in the first 43% of runoff within these sites. Similarly, rainfall depth and storm duration showed a positive correlation (R > 0.6) with nutrient loads within ISS group sites, as compared to PSS group. Therefore, these sites are likely to contribute higher TP and TN loads during heavier storm events and should be selected as priority management areas to combat the problem of eutrophication in Paldang reservoir.

Numerical Simulation of Coastal Urban Inundation due to Storm Surge and Rainfall (폭풍해일과 강우에 의한 해안 도시 범람 수치모의)

  • Kim, Gun Hyeong;Pyo, Chang Kyu;Yoon, Sung Bum
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.26 no.6
    • /
    • pp.388-396
    • /
    • 2014
  • In this study, numerical simulations are conducted for the inundations due to storm surge and rainfall at Masan City of Korea where severe damages occurred by the typhoon Maemi. A coupled numerical model which can deal with various flow patterns such as storm surge, rainfall and sewer flows is employed. The numerical results show that the inundation area and depth increase significantly when the combined effects of storm surge and rainfall are considered in comparison with those obtained without a rainfall effect. Further numerical simulations are conducted to evaluate the performance of the sea wall being constructed for the coastal defence. The results show that the maximum inundation depths decrease when the sea wall is constructed. However, the duration of inundation becomes longer, because the rainwater on the ground cannot be discharged easily to the sea due to the presence of the sea wall.

Generating Alternative Sewers Based on GIS and Simulation Technique (GIS 및 Simulation 기법에 의한 하수도관거 대안 생성)

  • 김형복;김경민
    • Spatial Information Research
    • /
    • v.5 no.2
    • /
    • pp.185-194
    • /
    • 1997
  • Spatial decision support systems(SDffi), a new class of decision support system(DSS), result from the melding together of GIS and DSS, Planning support systems(PS5) add more advanced spatial analysis functions than GIS and intertemporal functions to the functions of SDSS. This paper reports the development of a planning support system providing a framework that facilitates urban planners and civil engineers in conducting coherent deliberations about the generation of satisficing sewers. 1he planning support system for the generation of satisficing sewers(PS5/GSS) was designed from the understanding that land use and development drive the demand for storm and sanitary sewers. Through four stages of supply, demand, alternative generation, and evaluation, PSS/GSS integrates basic planning, preliminary design, and engineering design of sewer. GIS and graphic user interface are excellent toolboxes for designing sewer networks, estimating the quantity of wastewater, and showing generated alternative sewers. A sewer model using simulation tedmique can generate an initial sewer. Users can define alternative sewers by the direct manipulation of sewer networks or by the manipulation of parameters in the sewer model. The sewer model evaluates the performance of the user defined alternatives.

  • PDF

Hydrologic Cycle Simulation of Urban River for Rehabilitation of Water Environment (II) - Dorimcheon Basin - (물 환경 건전화를 위한 도시하천의 물 순환 모의 (II) - 도림천 유역 -)

  • Lee, Sang-Ho;Lee, Jung-Min
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.815-823
    • /
    • 2006
  • The hydrologic cycle in urban catchment has been changed due to the expansion of impervious area by rapid urban development. In this study, the SWMM 5 (Storm Water Management Model 5) model was used to simulate the hydrologic cycle of the Dorimcheon catchment which suffers from the distorted hydrologic cycle as a typical urban catchment. This study compare continuous simulation of urban runoff combining the channel and sewer system with that of channel only in the Dorimcheon catchment. Continuous simulations of urban runoff were performed for the upstream basin of Dorim bridge. The urban impervious regions were processed by the land use analysis from LANDSAT_TM images. It was performed from 1975 to 2000 for every five years. Surface, groundwater and wastewater runoffs were additionally included in the simulations one at a time. Such simulations made it possible to evaluate those components quantitatively. The result of continuous simulation of urban runoff combining the channel and sewer system is that peak flow and recession are well simulated. The analysis results of urbanization effect on runoff are as follows: the surface runoff in 2000 increases to 64% of the whole precipitation whereas the surface runoff in 1975 amounts to 46% of the precipitation; the groundwater runoff in 2000 amounts to 6% and shows 8% decrease during the period from 1975 to 2000.

Determination of the Depth of Sewers in Residental Complexes (주택단지내 하수관거의 매설심도 결정에 관한 연구)

  • Lim, Bong Su;Choi, Eui So;Yi, Yun Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.8 no.3
    • /
    • pp.41-50
    • /
    • 1994
  • The depth of sewers in residential complexes was determined to prevent the separated sewers from misconnection between storm sewer and sanitary sewer, and from the submersion of the basement by minimizing the phenomenon of backwater when it rains. In residential complexes, main causes of the submersion were the misconnection of sewers, rising of the backwater level at outfall in sewer system, poor maintenance of sewers, and lacking in their cross section. Minimum depth of sewers should be over 1.2~1.5m. According to the economic analysis, the depth of 1.5m~3.0m was appropriate for minimizing the submersion of basements and for making the disposal of domestic wastewater more easily.

  • PDF

Operational Improvement of Small Urban Storm Water Pumping Station (1) - Simulation of Flood Hydrograph using GIS-based Hydrologic Model (도시 소유역 배수펌프장 운영개선 방안 연구 (1) - GIS 기반 수문모형에 의한 홍수유출수문곡선의 재현)

  • Gil, Kyung-Ik;Han, Jong-Ok;Kim, Goo-Hyun
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.6
    • /
    • pp.682-686
    • /
    • 2005
  • Recently some urban areas have been flooded due to heavy storm rainfalls. Though major causes of these floodings may be attributed to localized heavy rainfalls, other factors are related to urban flooding including deficiency of storm sewer network capacity, change of surface runoff due to covered open channels, and operational problems of storm drainage pump stations. In this study, hydrologic and hydraulic analysis of Sutak basin in Guri city were carried out to evaluate flooding problems occurred during the heavy storm in July, 2001. ArcView, a world most widely used GIS tool, was used to extract required data for the hydrologic analysis including basin characteristics data, concentration times, channel routing data, land use data, soil distribution data and SCS runoff curve number generation from digital maps. HEC-HMS, a GIS-based runoff simulation model, was successfully used to simulate the flood inflow hydrograph to Sutak pumping station.

Determination of Interception Flow by Pollution Load Budget Analysis in Combined Sewer Watershed - Analysis of Pollution Load Budget in Watershed - (오염부하 물질수지 분석을 통한 합류식 하수관거 적정 차집용량 결정(I) -오염부하 물질수지 분석-)

  • Lee, Doojin;Kim, Juwhan;Woo, Hyungmin;Ahn, Hyowon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.547-556
    • /
    • 2005
  • The objective of this study is to obtain adequate intercepting flow during wet weather conditions in combined sewer system. Two study sites are selected under considering different population density, one is developed area with heavy urbanization. Another is recently developing area. In the analysis of field investigation, SS was most significant in initial flushing effects compared with other factors and showed the result with the order of COD, TP, TN. As compared with event mean concentration(EMC) of runoff, BOD, TN and TP showed high concentrations in wide area with relatively large population density. It is by the reason that much pollution load was discharged to receiving water from urbanized area during wet period. According to results of storm-water modeling, 53% of total COD and 52% of total SS pollution load were discharged to receiving water by overflow than intercepting capacity in middle population density site. Also, in the urbanized area, pollution load was discharged to receiving water by 49% of total COD and 77% of total SS. These results can be applied to setup for pollution load flow(budget) generation, collection, treatment and discharging in order to obtain adequate intercepting flow.

Study on the Runoff Characteristics of Non-point Source Pollution in Municipal Area Using SWMM Model -A Case Study in Jeonju City (SWMM모델을 이용한 도시지역 비점오염원의 유출특성 연구 -전주시를 대상으로)

  • Paik Do-Hyson;Lim Young-Hwan;Choi Jin-Kyu;Jung Paul-Gene;Kwak Dong-Heui
    • Journal of Environmental Science International
    • /
    • v.14 no.12
    • /
    • pp.1185-1194
    • /
    • 2005
  • The runoff characteristics of non-point source pollutions in the municipal area of Jeonju were investigated and analyzed by using the SWMM (Storm Water Management Model). The flow rates and water qualities of runoff from two types of drainage conduits were measured respectively. One was a conventional combined sewer system and the other was a separated sewer system constructed recently From August to November in 2004, investigations on two rainfall events were performed and flow rate, pH, BOD, COD, SS, T-N and T-P were measured. These data were also used for model calibration. On the basis of the measured data and the simulation results by SWMM, it is reported that $80-90\%$ of pollution load is discharged in the early-stage storm runoff. Therefore, initial 10-30 mm of rainfall should be controlled effectively for the optimal treatment of non-point source pollution in urban area. Also, it was shown that the SWMM model was suitable for the management of non-point source pollution in the urban area and for the analysis of runoff characteristics of pollutant loads.

Study on the Characteristics and Non-point Source Pollution Loads in Stormwater Runoff of Shihwa Lake (시화호 유역 비점오염물질의 유출특성 및 부하량 연구)

  • Ra, Kong-Tae;Kim, Kyung-Tae;Kim, Joung-Keun;Bang, Jae-Hyun;Lee, Jung-Moo;Kim, Sung-Keun;Kim, Eun-Soo;Yun, Min-Sang;Cho, Sung-Rok
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.14 no.1
    • /
    • pp.40-50
    • /
    • 2011
  • We study the characteristic and total flux of non-point pollutants such as total suspended solids (TSS), chemical oxygen demand (COD), dissolved nutrients, total phosphorus (TP) and total nitrogen (TN) in the storm water runoff from urban streams and sewer outlets of Banweol Industrial Complex around Shihwa Lake. The concentrations of non-point pollutants were generally increased with increasing of the duration and intensity of rainfall. Mean TSS concentration of Ansan stream was higher than that of sewer outlets but mean concentrations of COD, TP and TN were approximately 2~5 times higher of sewer outlet than of urban stream. TSS showed statistically positive relationships with COD and TP but it had negative correlation with dissolved nutrients. There was a significant correlation between total flux of non-point pollutants in the storm water runoff and total basin area of each sewer outlet, showing that the highest runoff flux was observed at 3rd sewer outlet which represents the largest basin area from Banweol industrial complex. Total runoff fluxes for TSS, COD, TP and TN in this study were 187,536 kg, 17,118 kg, 922 kg, 13,519 kg, respectively. Given the basin area of sewer outlet in Banweol industrial complex which corresponds only 3% from total catchment area around Shihwa Lake, enormous amount of non-point pollutants will be entered into Shihwa Lake without any treatment. It is necessary to manage and reduce of various non-point sources and pollutants because the runoff of nonpoint pollutants during storm events should be deteriorating the water quality of Shihwa Lake. Our results provides useful informations on the development of best managements practices (BMPs) for effective implementation of total pollution loads management system of Shihwa Lake.

A Study of Manhole Bursting due to Surcharged Flow in Large Sewer System (대규모 간선에 있어서 써차지 흐름에 동반되는 맨홀뚜껑 비산현상에 관한 연구)

  • Choi, Sung-Mo
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.2 s.13
    • /
    • pp.53-59
    • /
    • 2004
  • The mechanism of manhole bursting which occurs at excess rainfall events Is studied by using both the physical model and the numerical model (SWMM ; Storm Water Management Model). The result of numerical simulation to steep pressure rising agrees well with that of the physical model at the sewer system under surcharged flow. A cause of manhole bursting is an expansion and spout of the condensed all at manhole that results from the surcharged flow and press wave propagation caused by gate operation or closure of conduit at pumping station.