• Title/Summary/Keyword: storm sewer

Search Result 123, Processing Time 0.024 seconds

An Analysis about Inundation and Carrying Capacity of Drain Pipes in Urban Area (도시유역의 우수관거 통수능 및 침수특성 분석)

  • Lee, Jung-Ho;Jo, Duk-Jun;Kim, Joong-Hoon;Kim, Eung-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.1
    • /
    • pp.110-115
    • /
    • 2007
  • The localized rainfall happens frequently in urban areas recently and then, he drain pipes of urban areas do not drain well when the localized rainfalls happen. Specially, the inundation by the backwater on the lowland should be solved certainly in urban planning and sewer rehabilitation. In this study, it was examined whether the carrying capacities of the drain pipe are satisfied about a current design standard of the rainfall considering the outflows of the urban areas by the rainfall analysis. Also, the backwater in the drain pipe and the inundation on the lowland were analyzed considering the water level of the discharged river and the propriety of the design standard was examined by the analysis about the rainfall frequency. Also, the results offered the basic data to decide whether the detention reservoir should be established and the scale of the pump station.

  • PDF

Development of Flooding area estimation module for Rubber-tired Tram Disaster Management System Using the SWMM Model (SWMM 모형을 이용한 홍수시 바이모달 트램 운행 노선에 대한 침수 면적 산정 모듈 개발)

  • Kim, Jong-Gun;Park, Young-Kon;Yoon, Hee-Taek;Park, Youn-Shik;Jang, Won-Seok;Yoo, Dong-Seon;Lim, Kyoung-Jae
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.61-65
    • /
    • 2008
  • Urban flooding with surcharges in sewer system was investigated because of unexpected torrential storm events these days, causing significant amounts of human and economic damages. Although there are limitations in forecasting and preventing natural disasters, integrated urban flooding management system using the SWMM engine and Web technology will be an effective tool in securing safety in operating Bi-modal transportation system. In addition, the integrated urban flooding management system can be linked with general and transportation-related disaster management system in the future. In this study, With simulated values by the SWMM, which is a core engine of the Bi-modal disaster management system, flash flooding area estimation module was developed. Thus, the SWMM system codes were modified and new module was developed and integrated with the existing SWMM interface using the Delphi programming language. The flash flooding area estimation module is fully integrated with the SWMM interface, thus the area is estimated on-the-fly inside the system.

  • PDF

A Water Quality Modeling Study of Chunggye Stream during Combined Sewer OverFlow Period (합류식 하수관거 월류수 유입 기간 동안에 나타나는 청계천 수질 변화 모델 연구)

  • Yi, Hye-Suk;Park, Seok-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.12
    • /
    • pp.1340-1346
    • /
    • 2005
  • A water quality modeling study was performed for Chunggye stream during combined sewer overflow(CSO) period, utilizing the diagnostic system for water management in small watershed, CREEK-1(Cyber River for Environment and Economy in Korea). This system integrated geogaphic information system, data base, landscape ecological model(FRAGSTATS), watershed model(SWMM), water quality model (WASP5), and computer graphic. In this study, the watershed model and water quality model were extensively utilized so as to simulate water qualities and flow in Chunggye stream during wet periods. The Chunggye stream watershed was divided into 18 sub-basins in the watershed model and the stream reach into 11 segments in the water quality model. The watershed model was validated against field measurements of BOD, TN, TP, and flow at the downstream location, where the model results showed a reasonable agreement with the field measurements at all parameters. From this study, it was shown that the stream water quality would change along with elapsed time from rainfall start as well as rainfall intensity. The model results indicated that the water quality would significantly upgrade due to the first flush and high sewage ratio of CSO at the beginning of rainfall event, but become degraded along with the runoff increase due to dilution effect.

Sediment Transport Characteristics in a Pressure Pipeline (압력 원형관로내 유사이송특성 연구)

  • Son, Kwang Ik;Kim, Hyun Jung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3B
    • /
    • pp.205-209
    • /
    • 2011
  • The low carrying capacity caused by the deposition in a sewer line is one of the main reason of the urban flood. Therefore, an efficient maintenance and management of the storm water drainage system is very important to prevent urban flood. In this research, the sediment transport characteristics through a pressure pipeline were examined with laboratory experiments. Bed-forms in a pipeline, sediment rates, roughness due to sediments were examined. Experimental system consists of flow circulation system with a pump and a sediment feeder at the upstream of the pipeline. Sediments were supplied into a 60 mm-diameter and 8 m-long pipe. Maximum flow rate is $30m^3/hr$, and the sediment feeding rate range is 5 g/s~19 g/s. Governing parameters and estimation equation for sediment transport rate were developed. The mean velocity (U), coefficient of viscosity (${\mu}$), unit width bed load ($q_b$), mean diameter of particle ($d_{50}$), unit weight of sediment in water (${\gamma}^{\prime}_s$) were adopted as the most influencing factors of sediment transport patterns. The prediction equation for sediment transport rate were developed with two dimensionless terms. These two dimensionless terms showed a linear relationship with high correlation coefficient.

Identifying Cost and Benefit Items of Investment Projects to Offer New Public Services By the Use of Food Waste Disposers and the Direct Input of Feces in Sewers (주방오물분쇄기 사용 및 수세분뇨의 직투입에 따른 「새로운 공공하수도 서비스」제공을 위한 투자사업의 비용과 편익 항목 식별)

  • Oh, Hyun-Taek;Park, Kyoo-Hong;Kim, Sung Tai;Lim, Byung In
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.5
    • /
    • pp.117-125
    • /
    • 2020
  • Our study identifies a cost and a benefit incurred in implementing an investment project to offer new public services by use of food waste disposers and direct input of feces in sewers. This is done with identifying costs of each processing division and benefits of the project by objective statistical data and engineering perspective. In summary, cost items identified are as follows: there are house laterals, removal of septic tanks, etc. for sewer pipes system. As to water quality conservation, cost incurs in storm water outfalls and divert chambers, sewage storage tanks, equipment to treat sewer overflows, and so on. With respect to sewage treatment plants(STPs), there are so many items as increase of contaminant loads in influent of STPs, and other items. There are benefit items in health improvement due to odor mitigation, increase of energy productivity, saving cost of food waste treatment and cleaning septic tanks, etc. These estimates will be used as a basic data for its economic effect.

Simulating Bacterial Dispersion from Coastal Sewage Outfalls Using the QUICKEST Scheme (QUICKEST법을 사용한 연안해역에서 박테리아 확산의 수치모의)

  • Kang Yun Ho;Lee Moon Ock
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.2 no.2
    • /
    • pp.20-30
    • /
    • 1999
  • To improve water quality particularly for sea bathers along the Fylde coastal zone near Blackpool, North West England, waste water from a sewage outfall is studied using a mathematical model. The explicit second order accurate central scheme and the third order accurate QUICKEST scheme are used to represent the diffusion terms and the advection terms of the advective-diffusion equation, respectively. Hydrodynamic model is run for a coarse and fine grid, of 1km and 200m, respectively, obtaining good agreement with measured data. Water quality model is then used to predict faecal coliform levels in the region for four different scenarios, including discharges from: - (i) Fleetwood outfall, (ii)River Ribble for summer condition, (iii)River Ribble for winter condition, and (iv)combined sewer overflows for the Blackpool and Fleetwood communities. Main findings from the simulations are:- (i) Fleetwood outfall has a negligible impact on the beaches with respect to pathogen levels; (ii) Discharge from River Ribble for both summer and winter conditions is predicted in the range of coliform levels 10 -500 counts/100ml along the beach at Lytham St. Annes; and (iii) The CSO effluent discharges are predicted not to advect out into offshore by stronger tidal currents.

  • PDF

The Method for Transforming the Shape File in ESRI into the Oracle Spatial DB for the Spatial DB Construction of the Drainage System (하수관거 공간DB 구축을 위한 ESRI 공간 파일의 오라클 공간DB 자동 변환 기법)

  • Kim, Ki-Uk;Hwang, Hyun-Suk;Kim, Chang-Soo
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.7
    • /
    • pp.989-996
    • /
    • 2009
  • Recently, use of the GIS (Geographic Information System) for the disaster of the urban inundation is increasing. The digital disaster map is the system which analyzes the occurrence area of inundation in the past and forecasts the flood areas by the hydrology method. The development of the system which simulates the flood forecast area by the SWMM(Storm Water Management System) and hydrology method and displays the danger areas is required for the construction of the inundation forecast system. And the spatial database which contains information of the urban facilities such as the street and building and the sewer system such as the manhole and drainage and the result of the hydrology analysis is constructed. In this paper, we propose the method for transforming the Shape File in ESRI into the Oracle spatial database to construct the spatial data for the drainage systems and urban facilities using the Shape File format in the ESRI. We suggest the algorithm for the transformation of the data format, and develop the prototype system to display the inundation area using the spatial database.

  • PDF

A study of Assessment for Internal Inundation Vulnerability in Urban Area using SWMM (SWMM을 이용한 도시지역 내수침수 취약성 평가)

  • Shon, Tae-Seok;Kang, Dong-Ho;Jang, Jong-Kyung;Shin, Hyun-Suk
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.4
    • /
    • pp.105-117
    • /
    • 2010
  • The topographical depressions in urban areas, the lack in drainage capability, sewage backward flow, road drainage, etc. cause internal inundation, and the increase in rainfall resulting from recent climate change, the rapid urbanization accompanied by economic development and population growth, and the increase in an impervious area in urban areas deteriorate the risk of internal inundation in the urban areas. In this study, the vulnerability of internal inundation in urban areas is analyzed and SWMM model is applied into Oncheoncheon watershed, which represents urban river of Busan, as a target basin. Based on the results, the representative storm sewers in individual sub-catchments is selected and the risk of vulnerability to internal inundation due to rainfall in urban streams is analyzed. In order to analyze the risk and vulnerability of internal inundation, capacity is applied as an index indicating the volume of a storm sewer in the SWMM model, and the risk of internal inundation is into 4 steps. For the analysis on the risk of internal inundation, simulation results by using a SMMM model are compared with the actual inundation areas resulting from localized heavy rain on July 7, 2009 at Busan and comparison results are analyzed to prove the validity of the designed model. Accordingly, probabilistic rainfall at Busan was input to the model for each frequency (10, 20, 50, 100 years) and duration (6, 12, 18, 24hr) at Busan. In this study, it suggests that the findings can be used to preliminarily alarm the possibility of internal inundation and selecting the vulnerable zones in urban areas.

Simulation and analysis of urban inundation using the integrated 1D-2D urban flood model (1D-2D 통합 도시 침수 해석 모형을 이용한 침수 원인 분석에 관한 연구)

  • Lee, Seungsoo;Noh, Seong Jin;Jang, Cheolhee;Rhee, Dong Sop
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.4
    • /
    • pp.263-275
    • /
    • 2017
  • Integrated numerical approaches with physically-based conceptualization are required for accurate urban inundation simulation. In this study, we described, applied and analyzed an integrated 1-dimensional (1D) sewerage system and 2-dimensional (2D) surface flow model, which was suggested by Lee et al. (2015). This model was developed based on dual-drainage concept, and uses storm drains as an discharge exchange spot rather than manholes so that interaction phenomena between surface flow and sewer pipe flow are physically reproduced. In addition, the building block concept which prevents inflows from outside structures is applied in order to consider building effects. The capability of the model is demonstrated via reproducing the past flooding event at the Sadang-cheon River catchment, Seoul, South Korea. The results show the plausible causes of the inundation could be analysed in detail by integrated 1D-2D modeling.

A Study on the Effect of Water Quality Improvement of a Storm Sewage by Detention Pond (저류지에 의한 우수의 수질개선 효과 연구)

  • Lee, Jong-Tae;Song, Chi-Heung;Gang, Tae-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.3
    • /
    • pp.351-364
    • /
    • 2000
  • The effect of water quality improvement of combined sewage by detention pond has been studied. It is convinced that the pollutant load and peak flow through the combined sewer by first rainfall and runoff can be decreased by detention pond sited at the outlet of small basin. Hydraulic modeling of detention panel was performed for two cases of sedimentation pond and gravel contact pond. It has been recognized that it is more efficient to reduce the pollutant of combined sewage when the combined sewage is released alter a fixed detention time in the detention pond than it is released continuously without detention time. The gravel contact detention pond shows higher pollutant removal rate than the sedimentation detention pond in all pollutants. When it comes to gravel contact detention pond, the gravel pond filled with crushed gravel has a higher pollutant removal rate than that filled with river gravel.

  • PDF