• 제목/요약/키워드: storage reliability

검색결과 581건 처리시간 0.032초

태양열 시설원예 난방시스템 장기실증 성능분석 연구 (Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy)

  • 이상남;강용혁;유창균;김진수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.403-407
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a greenhouse culture facility for reducing heating cost, increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex in Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely investigated by changing the control condition based on the temperature difference which is the most important operating parameter. For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, it is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

RTDS를 이용한 신재생에너지 기반 마이크로그리드 시뮬레이션 해석 (Simulation analysis of a renewable energy based microgrid using RTDS)

  • 허세림;김경훈;이효근;황철상;박민원;유인근;박정도;이동영;이상진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.143-144
    • /
    • 2011
  • Due to enhanced demands on quality, security and reliability of the electric power energy system, a microgrid has become a subject of special interest. In this paper, output characteristics of energy storage system (ESS) with an electric double layer capacitor (EDLC) and battery energy storage system (BESS) of a renewable energy based microgrid were analyzed under grid-connected and islanded operation modes. The microgrid which consists of photovoltaic and wind power turbine generators, diesel generator, ESS with an EDLC, BESS and loads was modeled using real time digital simulator. The results present the effective control patterns of the microgrid system.

  • PDF

Seeding Method를 이용한 인이 도우핑된 Amorphous-Si에서의 HSG형성 조건 (Hemispherical Grained Silicon formation Condition on In-Situ Phosphorous Doped Amorphous-Si Using The Seeding Method)

  • 정양희;강성준
    • 한국정보통신학회논문지
    • /
    • 제5권6호
    • /
    • pp.1128-1135
    • /
    • 2001
  • 본 논문에서는 HSG형성을 위한 Si$_2$H$_{6}$의 조사와 어닐링을 통한 seeding method를 64Mbit DRAM에 적용하였다. 이 기술을 사용함으로서 인이 도우핑된 Amorphous 실리콘의 전극에 HSG grain 크기를 조절할 수 있었고, 이 새로운 HSG형성조건은 기존의 stack 캐패시터보다 약 2배의 정전용량을 확보할 수 있었다. 이와같은 방법을 이용한 HSG형성에서 인농도, 저장폴리 증착온도 및 HSG의 두께에 대한 공정 최적 조건으로는 각각 3.0-4.OE19atoms/㎤ , 53$0^{\circ}C$ 및 400$\AA$이었다. 이들 최적화된 공정조건으로 64M bit DRAM 캐패시터에 적용시 질화막의 두께 한계는 65$\AA$으로 확인되었다.

  • PDF

Design Improvement for the Cooling System of the Interim Spent Fuel Storage Facility Using a PSA Method

  • Ko, Won-Il;Park, Jong-Won;Park, Seong-Won;Lee, Jae-Sol;Park, Hyun-Soo
    • Nuclear Engineering and Technology
    • /
    • 제28권5호
    • /
    • pp.440-451
    • /
    • 1996
  • With emphasis on safety, this study addresses for better design condition for the cooling system in a wet-type interim spent fuel storage facility, using a probabilistic safety assessment method. To incorporate the design renovation into the design phase, a simple approach is proposed. By taking the cooling system of a reference design, a fault tree analysis was performed to identify the weak point of the considered system, and then basic factors for design renovation were defined. A total of 21 design alternatives were selected through the combination of the basic factors. Finally, the optimum design alternative for the cooling system is derived by means of the cost and effect analysis based on the estimated cost, system reliability and assumed probabilistic safety criteria. With the assumption that the failure frequency of at-reactor spent fuel cooling system compiles with probabilistic safety criteria for the interim spent fuel cooling system, it was shown that the optimum alternative should have l00% cooling loop redundancy with one pump per cooling loop and a cleanup system installed separately from the main loop. Furthermore, it also should be classified into safety system. The result of this study can be used as a useful basis to identify factors of safety concern and to establish design requirements in the future. The method also can be applied for other nuclear facilities.

  • PDF

태양열 시설원예 난방시스템 장기실증 성능분석 연구 (Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy)

  • 이상남;강용혁;유창균;김진수
    • 신재생에너지
    • /
    • 제1권2호
    • /
    • pp.53-59
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a green-house culture facility for reducing healing cost, Increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex In Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely Investigated by changing the control condition based on the temperature difference which Is the most important operating parameter For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, It is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

Melt-spining 공법에 의한 Mg-33.5%Ni 수소 저장 합금 제조 및 수소저장 특성 (Fabricatin and Hydrogen Storage Property of Mg-33.5%Ni Alloy Powder Prepared by Melt-Spining Process)

  • 홍성현;임창동;배종수;나영상
    • 한국수소및신에너지학회논문집
    • /
    • 제18권4호
    • /
    • pp.399-405
    • /
    • 2007
  • The hyper-eutectic Mg-33.5%Ni alloy was rapidly solidified by melt spinning process. The melt-spun Mg-33.5%Ni has amorphous structure and crystallization occurred above $162^{\circ}C$. The hydriding and dehydriding rates of melt-spun Mg-33.5%Ni increased with cycle and high rate of hydrogen storage occurred at 3rd cycle. The maximum hydrogen amount absorbed in melt-spun Mg-33.5%Ni at $300^{\circ}C$ is about 4.5%.

플라이휠 에너지 저장장치 회전체계의 동역학적 설계및 해석 (Rotordynamic Design and Analysis of the Rotor-Bearing System of a 500Wh Flywheel Energy Storage Device)

  • 최상규;김영철;경진호
    • 소음진동
    • /
    • 제8권1호
    • /
    • pp.81-86
    • /
    • 1998
  • A 500Wh class high-speed Flywheel Energy Storage System (FESS) driven by a built-in BLDC motor/generator has been designed, which runs from 30000 to 60000rpm nominally. Due to the motor/generator inside, the flywheel rotor made of composites supported by PM/EM hybrid bearing system has a shape of bell or pendulum and thus requires accurate rotordynamic analysis and prediction of its dynamic behavior to secure the operating reliability. Rotordynamic analyses of the flywheel rotor-bearing system revealed that the bell shaped rotor has two conical rigid-body modes in the system operating range and the first conical mode, of which nodal point lies in the radial EM bearing position, can adversely affect the dynamic response of the rotor at the corresponding critical speed. To eliminate the possibility of wild behavior of the rotor, two guide bearings are adopted at the upper end of the rotor and motor/generator. It was also revealed that the EM bearing stiffness if 0.5~1.0E+6 N/m and damping of 2000 Ns/m are favirable for smooth operation of the system around the 2nd critical speed.

  • PDF

Estimation of irrigation return flow from paddy fields based on the reservoir storage rate

  • An, Hyunuk;Kang, Hansol;Nam, Wonho;Lee, Kwangya
    • 농업과학연구
    • /
    • 제47권1호
    • /
    • pp.19-28
    • /
    • 2020
  • This study proposed a simple estimation method for irrigation return flow from paddy fields using the water balance model. The merit of this method is applicability to other paddy fields irrigated from agricultural reservoirs due to the simplicity compared with the previous monitoring based estimation method. It was assumed that the unused amount of irrigation water was the return flow which included the quick and delayed return flows. The amount of irrigation supply from a reservoir was estimated from the reservoir water balance with the storage rate and runoff model. It was also assumed that the infiltration was the main source of the delayed return flow and that the other delayed return flow was neglected. In this study, the amount of reservoir inflow and water demand from paddy field are calculated on a daily basis, and irrigation supply was calculated on 10-day basis, taking into account the uncertainty of the model and the reliability of the data. The regression rate was calculated on a yearly basis, and yearly data was computed by accumulating daily and 10-day data, considering that the recirculating water circulation cycle was relatively long. The proposed method was applied to the paddy blocks of the Jamhong and Seosan agricultural reservoirs and the results were acceptable.

전지전력저장시스템의 경제성 평가를 위한 분석모델의 연구 (A Study on Analysis Model for Economic Evaluation of Battery Energy Storage System)

  • 김응상;김호용;고요;임성정;김재철
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제10권5호
    • /
    • pp.75-82
    • /
    • 1996
  • 전지전력저장시스템(BESS)은 날로 심화되어 가는 부화율의 하락현상을 보완해 줄 수 있으며, 순동예비력, 전압 및 주파수제어, 발전 및 송배전 설비의 투자지연 효과, 공급신뢰도 향상 등의 효과를 가지고 있다. 이러한 BESS를 개발완료하여 실용화하기 위해서 경제성 평가가 수반되어야 한다. 본 연구에서는 Sysplan Model을 국내 실정에 맞게 수정 보완하여 경제성 평가를 통한 투자가치를 분석하였다.

  • PDF

압축된 방진고무의 강성 해석 (Stiffness Analysis of Compressed Rubber Components for Anti-Vibration)

  • 김국원;임종락;안태길
    • 한국정밀공학회지
    • /
    • 제16권6호
    • /
    • pp.141-147
    • /
    • 1999
  • Optical disk technology with a laser beam for data recording and retrieval is one of the most promising route for high density information storage in multimedia era. As the storage density and data transfer rates are increased, mechanical issues, mainly noise and vibration, become critical. Rubber materials are extensively used in various machine design application, mainly for vibration/shock/noise control devices. Over the years an enormous effort has been put into developing procedures to provide properties of rubber components with complex shape and under pre-deformed state. In this paper, non-linear large deformations of a rubber mount for optical disk drive were investigated using the finite element method. A tension test of rubber material was performed, to calculate a strain energy function. According to the pre-deformed state, the variation of rubber mount stiffness were calculated and the reliability of numerical results were checked by compared with the measuring the deflection values. Also, the effects of the pre-deformed rubber mount on the system dynamic characteristics were investigated and the relation between the static stiffness variation of rubber mount and the natural frequence variation of system was discussed.

  • PDF