• Title/Summary/Keyword: stone die

Search Result 41, Processing Time 0.019 seconds

DIMENSIONAL STABILITY OF IMPRESSION BODY USING SILICONE INDEX TOOTH TRAY IMPRESSION SYSTEM (Silicone Index Tooth Tray를 이용한 인상체의 체적안정성에 대한 연구)

  • Lee Kyu-Young;Jeong Seung-Mi;Shim June-Sung;Choi Byung-Gap;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.5
    • /
    • pp.622-632
    • /
    • 2005
  • Statement of problem: Silicone Index Tooth Tray impression system which does not use gingicord has a shortcoming. It takes time to remove internal wall of Silicone Index Tooth Tray for space of wash impression material. Purpose: This study was to evaluate whether providing certain space to impression body can prevent from doing complicated laboratory work. Material and methods: After mounting metal dies with shoulder and chamfer margins arbiturarily, SITT was produced using $Blu-mousse^(R)$. In one experimental group, wash impression was taken using $Fit-tester^(R)$ without removing interior surface of SITT and in the other group, wash impression was taken using $Fit-tester^(R)$ providing 0.5mm space in the SITT and then compared the differences in two groups. Results: 1. There was no significant difference between a group which did not allow space and a group which granted equal 0.5mm space. 2. There was no significant difference between gingival diameter, occlusal diameter of metal die that has shoulder margin and gingival diameter, occlusal diameter of metal die that has chamfer margin. 3. There was no significant difference between a group which did not take pick-up impression and a group which took pick-up impression through relining method using SITT 4. There was no significant difference between a group that poured immediately after taking primary impression and a group that poured after removing poured stone die. Conclusions: When taking an impression of an abutment using SITT impression system, it is considered to obtain clinically identical results between a group that did not grant a 0.5mm space within SITT for wash impression and a group which invest a space. Furthermore, it is considered possible to produce an individual die through secondary pouring.

The Surface Properties using various separating materials of dental gypsum products (다양한 석고 분리제를 이용한 치과용 석고의 표면 특성에 관한 연구)

  • Sung, Hwan-Kyung;Lee, Gyu-Sun;Hwang, Jae-Sun
    • Journal of Technologic Dentistry
    • /
    • v.30 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Gypsum products are used for the preparation of stone casts of oral and maxillofacial structures and as important adjuncts to dental laboratory operations involved in the production of dental prosthesis. Accuracy and dimensional stability over time are properties of concern in fixed prothodontics. Gypsum products used in denstry are a form calcium sulfate hemihydrate and are classified as 1 of 5 types according to International Standard Organization(ISO) 6873. All die materials exhibit some dimensional change during setting, but expansion and contraction during setting and dimensional changes in response to varations in temperature and the water-powder ratio must be minimal. Although numerous investigators have studied the properties of die materials, several products have been introduced recently with manufacturer claims of superior dimensional stalility. The aim of this study was to determine the surface properties using various separating materials of dental gypsum products The results were as follows 1. In the comparison of first and second plaster distances before separation in different separating agent, there was no significant difference except using Trio separating agent. The interface using Trio separating agent forms like to pores. 2. In the comparison of first and second plaster distances after separation in different separating agent, there was significant difference. The interface of plasters using WD-40, Trio and Vaseline was showed some gaps. Each they were measured at average 7.97 $\pm$ 2.07 ${\mu}m$, 63.09 $\pm$ 23.25 ${\mu}m$, 27.59 $\pm$ 4.19 ${\mu}m$. 3. In the comparison of the surface, the surface of control sample(using none seperating agent) showed irregular properties and the surface using Trio and Vaseline become wrinkled. Specially the surface using Vaseline was showed shiny properties. But the surface using MAGIC SEP, Plaster seperating agent, WD-40 showed regular properties.

  • PDF

GINGIVAL MARGIAL LEAKAGE AND BONDING PATTERN OF THE COMPOSITE RESIN INLAY ACCORDING TO VARIOUS THICKNESS OF DIE SPACER (Die spacer의 두께에 따른 복합레진 inlay의 치은 변연부 미세누출 및 접착양태에 관한 연구)

  • Park, Tae-Il;Shin, Dong-Hoon;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.152-163
    • /
    • 1995
  • This experiment was performed to observe the adhesion pattern and microleakage in the gingival margin according to variation in the resin cement thickness which results from thickness of Die spacer. which is considered to effect the adaptability of the composite resin inlays. Clearfil CR inlays were fabricated on stone models with CR Sep applicated once and Nice fit twice, 4 times, and 6 times each. After 2nd curing within the CRC-100 oven, CR inlays were cemented with CR inlay cement. Dye(2% methylene blue) penetration and adhesion pattern were evaluated after sectioning of gingival margin into :3 pieces. The results were as follows ; 1. The thickness of resin cement showed unevenchanging pattern with that of die spacer, namely, it was increased until 4 times' application of Nice-Fit but was decreased with 6 times' application of that. 2. The degree of dye penetration wasn't affected by cement thickness within a limited value. 3. Most of dye penetration was shown through the interface between cement and enamel rather than the interface between cement and CR inlay. This shows that the affinity of resin cement for CR inlay was superior to the adhesive strength with tooth structure. 4. No gap was found at the interface between enamel and cement but some showed separation between dentin and cement. It is concidered that the contraction force of cement was less than the bond strength with the enamel. 5. Lots of voids were found in the CR inlay and resin cement. There was a pooling tendency of bonding agent and cement in the axiogingival line angle portion. 6. In some specimens, cracks were shown in enamel margin. From this it could be considered that cavity preparation and surface treatment weakened the tooth structure.

  • PDF

Evaluation of the effect of abutment preparation angles on the repeatability and reproducibility using a blue light model scanner

  • Kim, Dong-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.4
    • /
    • pp.210-217
    • /
    • 2020
  • PURPOSE. The purpose of the study is to evaluate the repeatability and reproducibility of the abutment angle using a blue light scanner. MATERIALS AND METHODS. 0°, 6°, and 10° wax cast abutment dies were fabricated. Each of the silicone impression was produced using the replicable silicone. Each study die was constructed from the prepared replicable stone used for scans. 3-dimensional data was obtained after scanning the prepared study dies for the repeatability by using the blue light scanner. The prepared 3-dimensional data could have the best fit alignment using 3-dimensional software. For reproducibility, each abutment was used as the first reference study die, and then it was scanned five times per each. 3-dimensional software was used to perform the best fit alignment. The data obtained were analyzed using a nonparametric Kruskal-Wallis H test (α=.05), post hoc Mann-Whitney U test, and Bonferroni correction (α=.017). RESULTS. The repeatability of 0°, 6°, and 10° abutments was 3.9, 4.4 and 4.7 ㎛, respectively. Among them, the 0° abutment had the best value while the 10° abutment showed the worst value. There was a statistically significant difference (P<.05). The reproducibility of 0°, 6°, and 10° abutments was 6.1, 5.5, and 5.3 ㎛, respectively. While the 10° abutment showed the best value, the 0° abutment showed the worst value. However, there was no statistically significant difference (P>.05). CONCLUSION. In repeatability, the 0° abutment showed a positive result. In reproducibility, the 10° abutment achieved a positive result.

Accuracy of dies fabricated by various three dimensional printing systems: a comparative study (다양한 삼차원 프린팅 시스템으로 제작된 다이의 정확도 비교)

  • Baek, Ju Won;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.242-253
    • /
    • 2020
  • Purpose: The aim of this study was to compare the accuracy of dies fabricated using 3D printing system to conventional method and to evaluate overall volumetric changes by arranging the superimposed surfaces. Materials and Methods: A mandibular right first molar from a dental model was prepared, scanned and fabricated with composites of polyetherketoneketone (PEKK). Master dies were classified into 4 groups. For the conventional method, the impression was taken with polyvinylsiloxane and the impression was poured with Type IV dental stone. For the 3D printing, the standard die was scanned and converted into models using three different 3D printers. Each of four methods was used to make 10 specimens. Scanned files were superimposed with the standard die by using 3D surface matching software. For statistical analysis, Kruskal-Wallis test and Mann-Whitney U test were done (P < 0.05). Results: Compared to the standard model, the volumetric changes of dies fabricated by each method were significantly different except the models fabricated by conventional method and 3D printer of Stereolithography (P < 0.05). The conventional dies showed the lowest volumetric change than 3D printed dies (P < 0.05). 3D printed dies fabricated by Stereolithography showed the lowest volumetric change among the different 3D printers (P < 0.05). Conclusion: The conventional dies were more accurate than 3D printed dies, though 3D printed dies were within clinically acceptable range. Thus, 3D printed dies can be used for fabricating restorations.

A New 3D Shape Measurement Method using 2 CCD Cameras (2대의 CCD 카메라를 이용한 새로운 3차원 형상 측정법)

  • Kim, Jang-Ju;Jung, Gook-Young
    • Journal of Technologic Dentistry
    • /
    • v.24 no.1
    • /
    • pp.73-81
    • /
    • 2002
  • Accurate acquisition of surface geometries such as machined surfaces, biological surfaces, and deformed parts have been very important technique in scientific study and engineering, expecially for system design, manufacturing and inspection. Two camera method is relatively simple with an acceptable accuracy. In this paper, a new method is studied to acquire 3D geometric data of the small object such as a die in stone model. When the devices, cameras, laser beam and object are in a perfect plane, the calculation becomes very simple with less error. But this paper shows that arbitrarily positioned system can also be used to obtain 3D data.

  • PDF

Data Acquisition and Processing of 3D Object (3차원 물체의 데이터 획득 및 가공)

  • Yi, Kyoung-Woong;Choi, Han-Su;Kim, Nam-Oh
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.83-87
    • /
    • 2002
  • Accurate acquisition of surface geometries such as machined surfaces, biological surfaces, and deformed parts and processing 3D object have been very important technique in scientific study and engineering, expecially for system design, manufacturing and inspection. Defective human teeth are usually ground to be coped with special alloy coping which is hand-made by dental technician. This make dental technician to be difficult and take a long time Dental CAD/CAM Systems consist of two parts, data acquisition and milling. In this paper, a method is studied to mill object which is acquired 3D geometric data of the small object such as a die in stone model. This paper present a control program and a mechanical system for milling 3D object.

  • PDF

The Making and Use of the Bifid Ornamental Hairpin Stone Mold Excavated at Neungsan-ri, Buyeo (부여 능산리 출토 가랑비녀 용범(鎔范)의 제작과 사용 양상)

  • LEE, Soleon;KIM, Jiyoung;SEO, Hyunju
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.2
    • /
    • pp.4-21
    • /
    • 2021
  • A stone mold from the Sabi period of Baekje was excavated at the western tombs in Neungsan-ri, Buyeo where there was a recent excavation survey (2016). It was believed and reported that such stone molds were used for copper needles during the early Iron Age; however, a close re-examination of the form revealed that they were used for bifid ornamental hairpins. Given its casting form, the stone mold of Neungsan-ri is estimated to have been used to make bifid ornamental hairpins in a ∩ shape, narrowing down toward the tip. It is considered an artifact of the Goryeo dynasty. The stone used to make the bifid ornamental hairpin mold of Neungsan-ri was chlorite-schist, the principal minerals of which include chlorite, amphibole, and talc. Similar rocks are in nearby Buyeo (Oesan-myeon), Cheongyang, Gongju, and Yesan. They are mainly found between Jiseon-ri, Oesan-myeon, Buyeo, Sucheol-ri, Yesane-up, and Yesan. Nearly 70 bifid ornamental hairpins from the Goryeo dynasty were excavated at Neungsan-ri, Buyeo and the surrounding areas. Among them, the bronze ones excavated from the tombs of Songguk-ri, Buyeo are estimated to have been made using this mold as they closely resemble the Neungsan-ri mold. Stone was likely the preferred material for molds to make bronze artifacts as it was easy to sink a die. Regarding the bifid ornamental hairpin cast excavated in Neungsan-ri, they obtained stones in nearby areas 20~50km from their location, made bronze artifacts, and distributed them to nearby sites during the Goryeo dynasty. These artifacts suggest that the casting technology of using a stone mold was still employed then.

Comparison of the marginal fit of milled yttrium stabilized zirconium dioxide crowns obtained by scanning silicone impressions and by scanning stone replicas

  • Yus, Estefania Aranda;Cantarell, Josep Maria Anglada;Alonso, Antonio Minarro
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.236-244
    • /
    • 2018
  • PURPOSE. To determine the discrepancy in monolithic zirconium dioxide crowns made with computer-aided design and computer-aided manufacturing (CAD/CAM) systems by comparing scans of silicone impressions and of master casts. MATERIALS AND METHODS. From a Cr-Co master die of a first upper left molar, 30 silicone impressions were taken. The 30 silicone impressions were scanned with the laboratory scanner, thus obtaining 30 milled monolithic yttrium stabilized zirconium dioxide (YSZD) crowns (the silicone group). They were poured and the working models were scanned, obtaining 30 milled monolithic yttrium stabilized zirconium dioxide (YSZD) crowns (the plaster group). Three predetermined points were analyzed in each side of the crown (Mesial, Distal, Vestibular and Palatal), and the marginal fit was evaluated with SEM (${\times}600$). The response variable is the discrepancy from the master model. A repeated measures ANOVA with two within subject factors was performed to study significance of main factors and interaction. RESULTS. Mean marginal discrepancy was $22.42{\pm}35.65{\mu}m$ in the silicone group and $8.94{\pm}14.69{\mu}m$ in the plaster group. The statistical analysis showed significant differences between the two groups and also among the four aspects. Interaction was also significant (P=.02). CONCLUSION. The mean marginal fit values of the two groups were within the clinically acceptable values. Significant differences were found between the groups according to the aspects studied. Various factors influenced the accuracy of digitizing, such as the design, the geometry, and the preparation guidance, as well as the texture, roughness and the color of the scanned material.

Comparison of accuracy of digital data obtained by intra-oral scanner and extra-oral scanner (구강 내 스캐너와 구강 외 스캐너를 사용하여 취득된 스캔 데이터 정확도 비교)

  • Lee, Jae-Jun;Jeong, Il-Do;Kim, Chong-Myung;Park, Jin-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.37 no.4
    • /
    • pp.191-197
    • /
    • 2015
  • Purpose: The purpose of this study was to compare the accuracy of the scan data acquired by the extra-oral and intra-oral scanner. Methods: The maxillary right first molar was made of polymethyl methacrylate(PMMA) specimen. This PMMA specimen was scanned with a engineering scanner and intra-oral scanner. Meanwhile, extra-oral scanner scanned stone die duplicated from PMMA master die. Trueness and precision of scan datas was measured by 3-dimensinal inspection. Independent t-test was conduct to analysis the significant difference(a=0.05). Results: In the trueness analysis, mean of discrepancies were 13.82um for intra oral scanner and 16.84 um for extra-oral scanner. In the precision analysis, mean of discrepancies were 11.72 for inta-oral scanner and 9.2 for extra-oral scanner. Both trueness and precision showed a statistically significant difference (Table 1, p<0.05). Conclusion: Intra-oral scanner can show higher trueness than extra-oral scanner, it has lower precision.