• 제목/요약/키워드: stereo-microscope

검색결과 73건 처리시간 0.023초

지대주 경사각이 지르코니아 전부도재관의 변연적합도에 미치는 영향 (The Effect of Abutment Inclined Angle on the Marginal Fit of Zirconia All-ceramic Crown)

  • 이서연;정인성;전병욱
    • 대한치과기공학회지
    • /
    • 제38권3호
    • /
    • pp.111-117
    • /
    • 2016
  • Purpose: The present study was performed to investigate the effect of abutment inclined angle on the marginal fit of zirconia all-ceramic crown. Methods: The Ti abutments with 3 different inclined angle($2^{\circ}$, $4^{\circ}$ and $6^{\circ}$) were fabricated. The zirconia copings were fabricated for each abutment by using dental CAD/CAM system. The manufactured zirconia copings were duplicated through silicone replica technique, and a replicated specimen was sectioned in the center of bucco-lingual and mesio-distal axial to measure the marginal fit by using a stereo microscope. The results were analyzed using a one-way ANOVA with SPSS 22.0 for Windows(${\alpha}=0.05$). Results: On the bucco-lingual axial, marginal fit was the RL3($41.5{\pm}3.4{\mu}m$), RL2($44.3{\pm}4.3{\mu}m$) and RL1($47.5{\pm}5.7{\mu}m$), respectively. On the mesio-distal axial, marginal fit was the RL3($41.1{\pm}3.7{\mu}m$), RL2($45.7{\pm}5.3{\mu}m$) and RL1($46.2{\pm}4.5{\mu}m$), respectively. One-way ANOVA showed statistically significant difference between groups for marginal fit(p<0.05). Conclusion: For marginal fit of the abutments inclined angle, RL3 specimen was superior. The abutment inclined angle had influence on marginal fit of the zirconia copings. The marginal fit of each group were within clinically acceptable range.

미세도구를 사용한 미세크기의 우라늄입자 취급기술 (Techniques for Handling Uranium Particles with Micro-tools)

  • 표형열;박용준;손세철;전영신;송병철;지광용;김원호
    • 분석과학
    • /
    • 제13권4호
    • /
    • pp.440-445
    • /
    • 2000
  • 흔적량 입자분석을 위해서는 흔적량의 입자를 다룰수 있는 미세도구가 필요하며 이들을 능숙하게 다룰수 있는 기술 또한 필수적이다. 본 연구에서는 다양한 미세도구들의 제작 및 사용방법을 소개하고 원자력 시설의 먼지시료 중 존재하는 우라늄입자의 동위원소비를 측정하였으며 이 결과로부터 미신고 핵활동 시설에서 사용한 우라늄의 종류를 알아 낼 수 있는 기술의 가능성을 확인하였다. 원자력 시설내의 오염가능 지역에서 기기의 표면 또는 바닥을 여과지로 문질러 시료를 채취하였고 먼지 중 존재하는 흔적량의 우라늄입자는 고체트랙 검출기를 이용하여 참아내었으며, 찾은 미세크기의 우라늄 입자는 미세도구를 사용하여 절단 분리한 후 TIMS의 필라멘트로 옮겨서 우라늄입자의 동위원소 비를 측정하였다.

  • PDF

수온과 염분이 양태 자치어의 성장과 생존에 미치는 영향 (Effects of Water Temperature and Salinity on the Growth and Survival of Larvae and Juvenile of Platycephalus indicus)

  • 이진;윤지원;이성훈;한경호
    • 한국어류학회지
    • /
    • 제35권1호
    • /
    • pp.39-43
    • /
    • 2023
  • 실험구의 수온은 13, 16, 19, 22, 25℃로 설정하였고, 염분농도는 각각 7, 14, 21, 28, 32 psu로 설정하였으며, 200 L 플라스틱 원형수조에 부화 자어를 각각 500마리씩 수용하였다. 성장은 수온 25℃(21.62±0.14 mm TL)와 염분 28 psu (15.02±0.05 mm TL)에서 가장 높았고, 수온 13℃ (7.04±0.05 mm TL)와 염분 7 psu에서 가장 낮았다. 생존율은 수온 22℃(69.2%)와 염분 32 psu (84.1%)에서 가장 높았으며, 수온 13℃(15.1%)와 염분 7 psu에서 가장 낮았다. 양태는 강어귀 또는 연안 해역에 서식하여 채집이 가능한 어종으로 다른 해수 어종에 비해 염분 내성이 강하였다.

Microplastic pollution in two industrial locations of the Karnaphuli River, Bangladesh: insights on abundance, types, and characteristics

  • Shahida Arfine Shimul;Zannatul Bakeya;Jannatun Naeem Ananna;Antar Sarker;Saifuddin Rana;Sk. Ahmad Al Nahid
    • Fisheries and Aquatic Sciences
    • /
    • 제26권12호
    • /
    • pp.715-725
    • /
    • 2023
  • Microplastic (MP) pollution in aquatic environments is a growing concern worldwide. This study investigated the abundance, types, and attributes of MPs in the surface water at two industrial sites (Avoimitro Ghat and Kalurghat) along the Karnaphuli River in Chattogram, Bangladesh. Sampling was conducted over eight months across three transects encompassing a total area of 500 m at each site. A manta net of 200 ㎛ mesh size was used to sample MPs. The obtained samples were subsequently filtered, enumerated, and characterized using a stereo microscope and imaging software. The mean abundance of MP particles (per km2 ) was found higher in Avoimitro Ghat (94,861 ± 57,126) than in Kalurghat (31,343 ± 23,183). A significant statistical difference (p < 0.05) was observed in the mean abundance of MP particles between the wet and dry seasons. The fragment group of MP exhibited the most abundant category, whereas the pellet category displayed the lowest. MPs with an elongated shape prevailed at both locations throughout all seasons. At Avoimitro Ghat, blue-colored MPs demonstrated the highest mean count, while in Kalurghat, the highest mean count belonged to brown-colored MPs. The size distribution of MPs differed between the two sites, with 1-2 mm MPs being plentiful in both seasons and Avoimitro Ghat, whereas MPs ranging from 500 ㎛ to less than 1 mm were abundant in Kalurghat. Ten (10) polymer types were found from Fourier-transform infrared spectroscopy (FTIR) analysis with high levels of polypropylene atactic in both Avoimitro Ghat (32%) and Kalurghat (17%). The findings provide important insights into MP pollution in the Karnaphuli River, which may aid in developing effective strategies to mitigate the impacts of MP pollution on the aquatic ecosystem and human health.

치아이동시 치근 흡수에 따른 치근항체의 역가 변화 (Changes in the Titer of Tooth Root Antibodies Accompanying Root Resorption Associated with Orthodontic Tooth Movement)

  • 박수병;손우성
    • 대한치과교정학회지
    • /
    • 제24권2호
    • /
    • pp.303-317
    • /
    • 1994
  • 치아이동시 발생되는 치근 흡수에 관련된 특이면역반응의 역할을 연구하기 위해 치근 흡수에 따른 치근항체의 역가 변화를 관찰하였다. 생후 2년된 성견 다섯마리를 실험동물로 사용하였다. closed coil spring을 사용하여 각 실험동물의 상악 6전치에 200-250gm의 함입력을 가하였으며, 하악 6전치를 발거하여 동종항원으로 사용하였다. 발거된 하악 전치의 상아질 부위를 분리하여 6M Guanidine-HCl-10% EDTA(pH 5.0)에서 해리시킨 다음 부유물 만을 투석하여 항원을 준비하였다. 치아를 함입시키기 전 1회 혈청을 채취하고 함입시키면서 매주 간격으로 11회 형철을 채취하였다. 실험 9주째 치근 흡수가 일어나고 있는 상악 6전치를 모두 발거하여 항원의 근원을 제거하였다. 혈청 내 치근항체의 역가는 ELISA(enzyme-linked immunosorbent assay)로 측정하였다. 항체 특이성에 대한 대조군으로 혈청과 치근 항원 그리고 혈청과 관련없는 박테리아 항원(Porphyro monas gingivalis 33277)을 섭씨 25도에서 3시간 반응시켜 모든 과정에서 항원-항체 반응을 측정하였다. 치근 흡수를 관찰하기 위하여 실험 전과 실험 후 한 달 간격으로 방사선 교합사진을 촬영하였고 9주째 발거한 치아의 치근단 부위를 입체현미경으로 관찰하였다. 치근항원에 대한 자가항원의 역가 변화를 측정하여 다음과 같은 결과를 얻었다. 자가항체의 역가는 치아가 함입되면서 즉시 감소하였다가 1주후 다시 증가하였으며 4주째 최고수준에 도달한 다음 다시 지속적으로 감소하였다. 흡수 중인 치근을 발거한 직후 급격히 증가하는 양상을 보였다. 치근 항원과 반응시킨 혈청내에서는 항원-항체 반응이 거의 나타나지 않았으며 관련없는 박테리아 항원과 반응을 시킨 혈청에서는 활성도가 동종 치근 항원에 대한 자가항체의 활성도와 비슷하게 나타났다. 방사선 교합사진 상에서는 육안으로 구별할 수 있는 차이가 거의 없었으나 입체현미경하에서는 치근단 부위의 다양한 흡수 양상을 관찰할 수 있었다.

  • PDF

국보 제193호 봉수형유리병 금사의 특성과 제작기법 연구 (A Study on the Characteristic and Manufacture Technique for the Gold wire of Phoenix-Shaped Glass Ewer by National Treasure No. 193)

  • 황현성;윤은영
    • 보존과학회지
    • /
    • 제31권1호
    • /
    • pp.21-27
    • /
    • 2015
  • 국보 제193호 봉수형유리병은 5세기에 조성된 것으로 알려진 황남대총 남분의 수많은 부장품들 사이에 독특한 형태의 녹색 유리 편들로 심하게 파손된 채 출토되었다. 1984년 국립중앙박물관 보존과학실에서 본격적으로 보존처리를 실시하여 박물관에서 오랜 기간 동안 전시되어 왔지만, 30년이라는 세월로 인해 기존에 사용한 접착제는 심하게 열화가 되어 매우 불안전한 상태가 되었으며 특히 복원제로 사용한 에폭시 수지가 빛과 열에 의해 심하게 황변이 되어 더 이상 유물의 안정한 전시와 효과적인 전시가 이루어질 수 없어 이번에 재 보존처리를 하게 되었다. 이번 연구에서는 그동안 연구가 전혀 진행되지 않았던 세 조각으로 파손된 봉수형유리병 손잡이 부분을 금사로 정성스럽게 감아 수리에 사용한 3 조각의 금사를 중점적으로 살펴보았다. 금사에 대한 분석방법으로는 SEM-EDS와 Stereo Microscope를 사용하여 비파괴적으로 분석하였다. 먼저, SEM-EDS 분석 결과, Au 91.9wt%-Au 92.8wt% 와 Ag 5.9wt.%-Ag 6.5wt.%으로 Au 과 Ag의 합금인 금제로 밝혀졌다. 다음으로 광학현미경으로 금사의 제작기법을 관찰한 결과, 일반적으로 금사는 덩이 금을 두드려서 만들거나 구멍에 밀어 넣어 뽑아내는 인발 가공 또는 금판을 꼬아서 제작하는 방법으로 제작하는데 봉수형유리병 손잡이에서 분리한 금사는 표면에서 꼬임 흔적은 전혀 나타나지 않고 단지 길이 방향으로 미세한 줄무늬가 관찰되고 단면이 모두 채워진 상태인 것으로 보아 인발 가공하여 만든 것을 사용하여 보수한 것으로 생각된다. 이러한 분석 결과는 그동안 금사에 대한 연구가 대부분 금제품 유물의 구성품으로만 인식된 채 별도의 유물로 주목받지 못해 금사에 대한 제작기법에 대한 체계적인 연구가 매우 미흡한 편이기 때문으로 장차 금사에 대한 추가적인 연구가 진행된다면 이번 봉수형유리병 손잡이 고정에 사용된 금사 분석 결과가 기존 신라시대 금제 유물의 금사와의 상호 연관성을 밝혀내는데 좋은 자료가 될 것으로 생각된다.

복합레진 수복시 상아질 표면 처리가 미세 변연 누출에 미치는 영향에 관한 연구 (THE EFFECT OF MOISTENING OF ETCHED DENTIN AND ENAMEL SURFACE ON THE MICROLEAKAGE OF COMPOSITE RESINS)

  • 전철민;권혁춘;이정식;이명종;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제21권1호
    • /
    • pp.321-338
    • /
    • 1996
  • The purpose of this study was to evaluate the effect of moistening and air-drying of acid conditioned dentin and enamel on the marginal microleakage. In this study, Class V cavity were prepared on both buccal and lingual surface of sixty extracted human premolars with cementum margin. These specimens were randomly devided into three groups and three dentin adhesives(Scotchbond Multi-Purpose, All bond 2, Prisma Universal Bond 3) were applied to each group. The specimens in each group were subdevided into four groups (Wet/primed, Dry/primed, Wet/not primed, Dry/not primed) and the etched dentin and enamel surface were treated these four surface treatments prior to the placement of a bonding agent or adhesive. Wet/primed group was simply blot-dried with a damp facial tissue before primer placement ; Dry/primed group was air dried for 30 seconds before the placement of a primer ; Wet/not primed group and Dry/not primed group were not primed after blot dried and air dried for 30 seconds each group. The bonding agent and composite resin were applied for each group. All specimens were exposed to 500 cycle of thermal stress. Specimens were placed in a silver nitrate solution and then sectioned buccolingually through the center of the restoration. The dye penetrations of the specimens were observed with a stereo microscope. The statistical test were applied to the results using a one way analysis variance (ANOVA) and Duncan's multiple range test. The aspects of silver ion penetration into the resin/dentin interface were examined under scanning electron microscopy. The results were as follows. 1. In all groups, the enamel margin showed significantly lower leakage value than the cementum margin (p<0.05). 2. Regardless of various surface treatment and dentin adhesives, there was no significant difference at the enamel margins (p>0.05). 3. At the dentin margins, the leakage values of Dry/not primed group showed significantly higher than that of the other groups (p<0.05). The leakage values of Wet/primed group showed significantly lower than that of the other groups, but, there was no significant difference between Wet group and Dry group. 4. There was no significantly difference between the dentin adhesives regarding the surface treatments in all groups(p>0.05). 5. On the backscatterd scanning electron microscopy observation, the penetration of the silver ion occured at the bonding resin/dentin interface. In the Wet/primed group, resindentin hybrid zone and resin penetration into the dentin was observed. The resin tags were compactively formed to a thickness of $3\sim4{\mu}m$ at the upper part of dentinal tubules. In the Dry/primed group, the thickness of the hybrid zone and the diameter, depth of the resin tags diminished. In the Non-primed groups, the hybrid zone was not identified and few resin tag was observed. There was the gap formation in the resin/dentin interface.

  • PDF

주정오니를 활용한 수중의 카드뮴(Cd) 흡착 특성 (Adsorption Characteristics of Cadmium ions from Aqueous Solution using by-product of Brewing)

  • 김민수;함광준;옥용식;강선홍
    • 한국환경농학회지
    • /
    • 제29권2호
    • /
    • pp.152-158
    • /
    • 2010
  • 본 연구는 맥주제조공장에서 발생하는 주정오니의 영양염류 용출특성 및 폐수중 존재하는 카드뮴(Cd)이온에 대한 흡착특성을 알아보고 이를 통하여 생물흡착제의 적용가능성을 알아보기 위하여 수행하였다. 흡착실험에 사용된 흡착제는 회화를 하지 않은 원시료(M-Raw)와 $300^{\circ}C$, $400^{\circ}C$, $500^{\circ}C$로 회화된 시료를 준비하여 증류수를 이용하여 용출실험을 하였으며 그 결과 원시료(M-Raw)의 경우 수중에 용출된 인 질소의 양은 $400^{\circ}C$로 회화시킨 시료(M-400)에 비해 각각 7배, 11배 이상의 용출량을 나타내었으며 이는 회화로 인하여 시료를 구성하고 있는 관능기가 대기중으로 방출되어 수중에 용출되는 양이 감소한 결과로 생각된다. TGA를 이용한 회화 실험결과 $260^{\circ}C\sim380^{\circ}C$범위에서는 급격한 무게감량이 일어 났으며, $380^{\circ}C$ 이후에는 완만한 무게감량이 일어나는 것을 볼 수 있는데 이는 생물흡착제를 구성하고 있는 성분들(cellulose, hemicellulose, lignin)의 서로 다른 분해온도로 인한 결과 로 생각된다. 또한, 회화 전 후의 표면변화를 관찰한 결과 회화를 거치지 않은 시료는 표면이 거칠고 불순물이 존재하는 반면, 회화를 끝낸 시료의 경우 표면의 불순물이 제거되고, 동시에 표면의 갈라짐을 관찰할 수 있었다. 회화 전 후의 생물흡착제 표면변화 및 특성을 알아보기 위하여 미세영상장비와 FT-IR을 사용한 결과, 회화온도가 올라갈수록 흡착제표면의 갈라짐이 관찰되었으며 관능기의 개수는 점차로 줄어드는 결과를 나타내었다. 회화 전 후 시료의 FT-IR 분석결과 회화전 시료의 경우 3300 $cm^{-1}$ 부근에서 hydroxyl group 이 나타났으며 1080~1730 $cm^{-1}$ 범위에서는 여려종류의 관능기를 관찰할 수 있었다. 회화 전 1600~1080 $cm^{-1}$ 부근에서 관찰된 primary amine, secondary amine, aliphatic nitro compounds, aromatic phosphate 등의 작용기는 회화 온도가 증가할수록 spectrum이 점차로 줄어드는 결과를 나타내었다. 중금속 흡착 실험결과 본 실험에서 사용된 생물흡착제의 카드뮴이온 제거율은 농도위 20 mg/L 이하에서 60~91%로 나타났으며, 흡착 평형을 이루는 시간은 3시간이 소요되었다. 실험결과를 Freundlich 및 Langmuir 모델에 적용시킨 결과 Langmuir 모델에 더 잘 부합되는 결과를 나타내었으며, 최대흡착량($Q_{max}$)은 회화를 시키지 않은 시료(M-Raw)의 경우 28.17 mg/g으로 매우 높은 수준을 나타내었다.

1차 포장이 이침의 침첨 불량에 미치는 영향 (The effect of initial packaging on the deformation of ear acupuncture needle tips)

  • 최광호;권오상;이상훈;조성진;이새봄;연선희;최선미;류연희
    • 한국한의학연구원논문집
    • /
    • 제18권3호
    • /
    • pp.87-93
    • /
    • 2012
  • Objectives : The present study is to verify whether the deformation of ear acupuncture needle tips that are currently on the market is caused during the process of initial packaging. Methods : Ear acupuncture needles distributed from three different companies were collected to measure the size of the groove on the transparent plate which is used in for the intial packaging. Then the tolerance range for off-centered tips, which represent the range of the groove size that is safe from damaging the needle tip, was determined based on the vertical length measured from tip to handle. 200 ear acupuncture needles were dipped in alcohol and scanned to confirm the position of the needles. Stereo-microscope was used to observe the needle tips that were located outside the tolerance range. Results : The increased number of ear acupuncture needle tips placed outside the tolerance range were seen from in the order of C company, A company and B company. The increased deformation of the needle tips caused by initial packaging was observed in the order of A company, C company and B company. Conclusion : Only the ear acupuncture needles from B company showed the strong correlation between needle tip deformation and initial packaging. It has been observed that the deformation of the ear acupuncture needles is mainly due to manufacturing process, not the packaging process.

변연형태와 레진시멘트에 따른 IPS Empress 도재관의 변연누출에 관한 연구 (A STUDY ON THE MICROLEAKAGE OF THE IPS EMPRESS CERAMIC CROWN ACCORDING TO MARGIN TYPES AND RESIN CEMENT)

  • 정원엽;오상천;동진근
    • 대한치과보철학회지
    • /
    • 제36권6호
    • /
    • pp.789-805
    • /
    • 1998
  • The purpose of this study was to compare the microleakage of the IPS Empress ceramic crown according to 1) margin types such as rounded shoulder and bevel, 2) margin locations such as enamel and dentine, 3) resin cement types such as Variolink and Bistite. For this study, 80 extracted premolar teeth were used. After 10 experimental dies were prepared for each group, the IPS Empress ceramic crowns were fabricated on the dies and cemented with one of two types of resin cement. After 1,000 cycles of thermal changes were given with the thermocycling unit, each specimen was sectioned with a low speed diamond saw in both the buccolingual and the mesiodistal direction. The microleakage was then measured with a stereo microscope. The obtained results were as follows : 1. Every experimental group showed microleakage. The microleakage of the crowns which had a rounded shoulder on enamel cemented with Variolink was the lowest of all. The resulting rank of the mean microleakage was rounded shoulder on enamel using Variolink(0.601mm), rounded shoulder on enamel using Bistite (0.794mm), bevel on enamel using Variolink (0.826mm), rounded shoulder on dentine using Variolink(1.054mm), bevel on enamel using Bistite(1.087mm), rounded shoulder on dentine using Bistite(1.176mm), bevel on dentine using Variolink(1.258mm), and bevel on dentine using Bistite(1.467mm). 2. The statistically significant differences in the microleakage were found in 4 cases: rounded shoulder on enamel using Variolink and bevel on dentine using Variolink, rounded shoulder on enamel using Variolink and bevel on dentine using Bistite, rounded shoulder on enamel using Bistite and bevel on dentine using Bistite, bevel on enamel using Variolink and bevel on dentine using Bistite. 3. The microleakage of rounded shoulder finish line was lower than that of bevel finish line. The statistically significant differences were found with respect to the type of finish lines. 4. The microleakage of the finish line on enamel was lower than that of finish line on dentine. The statistically significant differences were found with respect to the location of the finish lines. 5. The microleakage of the Variolink cement was lower than that of the Bistite cement. The statistically significant differences were found with respect to the resin cements.

  • PDF