• Title/Summary/Keyword: step up

Search Result 2,386, Processing Time 0.031 seconds

Effect of Step-up and Step-down Hyperthermia on Skin of Mice (온열요법시 온도변화가 정상조직에 미치는 영향)

  • Choi, Ihl-Bohng;Kim, Choon-Yul;Bahk, Yong-Whee
    • Radiation Oncology Journal
    • /
    • v.6 no.2
    • /
    • pp.155-161
    • /
    • 1988
  • The usefulness of hypertermia for cancer therapy have well been established. The purpose of the present investigation was to ascess the effect of step-up $(42^{\circ}{\rightarrow}44^{\circ}C$ sequence) and step-down $(44^{\circ}{\rightarrow}42^{\circ}C$ sequence) heating on the skin of the hind foot of the mouse. Hyperthermic treatments were given by immersion the hind foot of the mouse in circulating water baths. Skin response was studied by the leg reaction, which was scored according to a numerical scoring system proposed by Urano et al (1980). The results were as follows 1. The skin damage of $44^{\circ}C$ control group was more severe than $42^{\circ}C$ control group (P<0.05), except for 15 min. heating group. 2. The Skin damage of step-down group was more severe than step-up group (P<0.05). 3. The skin damage of $44^{\circ}C$ control group was more severe than step-up group when there is no difference in $44^{\circ}C$ heating time of step-up group from $44^{\circ}C$ control group (P<0.05). 4. In step-down group, the skin damage was more severe than $44^{\circ}C$ control group after preheating 45 min at $44^{\circ}C$ (P<0.05). Therefore, the above findings suggest the normal tissue damage by step-up heating was correlated with heating time of post step-up. The dropping of heating temperature in late phase had more severe damage of the skin than that in early phase during hyperthermia, and so contineous control of satisfactory temperature should be considered as the one of the most important factor for prognosis, complications of clinical hyperthermia

  • PDF

PRICING STEP-UP OPTIONS USING LAPLACE TRANSFORM

  • KIM, JERIM;KIM, EYUNGHEE;KIM, CHANGKI
    • Journal of applied mathematics & informatics
    • /
    • v.38 no.5_6
    • /
    • pp.439-461
    • /
    • 2020
  • A step-up option is a newly developed financial instrument that simultaneously provides higher security and profitability. This paper introduces two step-up options: step-up type1 and step-up type2 options, and derives the option pricing formulas using the Laplace transform. We assume that the underlying equity price follows a regime-switching model that reflects the long-term maturity of these options. The option prices are calculated for the two types of funds, a pure stock fund composed of risky assets only and a mixed fund composed of stocks and bonds, to reflect possible variety in the fund underlying asset mix. The impact of changes in the model parameters on the option prices is analyzed. This paper provides information crucial to product developments.

Transformation Characteristics of Multi layed Ring-dot type Piezo Transformer (적층형 Ring-dot type 압전변압기의 변압특성)

  • Chong, Hyon-Ho;Park, Tae-Gone;Kim, Myong-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.671-674
    • /
    • 2004
  • This paper presents design and analysis of multi-layered ring-dot type piezoelectric transformer. These transformers are useful for step up and step down. The transformers consist of disk type multi-layered piezoelectric ceramic plates. The finite element method(FEM) was used for analysis transformer. Vibration mode, electric field and equivalent elastic strain of piezoelectric transformer were simulated by changing frequency. As results, the strain was distributed in isolation part entirely. We can get the operated in step up transformer when the inner side electrode using by input parts. Also we can get the step down transformers using by input Part as outer side electrode. The step up ratio and step down ratio was increased by decreasing inner side electrode. The resonance frequency was increased by increasing inner side electrode when the transformer was operated in step down transformer. But the step up one was decreased. From these results, we can expect to multi-layered ring-dot type piezo transformers as step up and step down transformers.

  • PDF

Single-Ended High-Efficiency Step-up Converter Using the Isolated Switched-Capacitor Cell

  • Kim, Do-Hyun;Jang, Jong-Ho;Park, Joung-Hu;Kim, Jung-Won
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.766-778
    • /
    • 2013
  • The depletion of natural resources and renewable energy sources, such as photovoltaic (PV) energy, has been highlighted for global energy solution. The PV power control unit in the PV power-generation technology requires a high step-up DC-DC converter. The conventional step-up DC-DC converter has low efficiency and limited step-up ratio. To overcome these problems, a novel high step-up DC-DC converter using an isolated switched capacitor cell is proposed. The step-up converter uses the proposed transformer and employs the switched-capacitor cell to enable integration with the boost inductor. The output of the boost converter and isolated switched-capacitor cell are connected in series to obtain high step-up with low turn-on ratio. A hardware prototype with 30 V to 40 V input voltage and 340 V output voltage is implemented to verify the performance of the proposed converter. As an extended version, another novel high step-up isolated switched-capacitor single-ended DC-DC converter integrated with a tapped-inductor (TI) boost converter is proposed. The TI boost converter and isolated-switched-capacitor outputs are connected in series to achieve high step-up. All magnetic components are integrated in a single magnetic core to lower costs. A prototype hardware with 20 V to 40 V input voltage, 340 V output voltage, and 100 W output power is implemented to verify the performance of the proposed converter.

Development of Boost Chopper with Built New Renewable Energy in Grid-Connected Distributed Power System (승압 초퍼 기능이 내장된 새로운 태양광 발전용 파워컨디셔너의 개발)

  • Mun, Sang-Pil;Lee, Su-Haeng;Kim, Young-Mun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.361-367
    • /
    • 2014
  • This paper is related to a new solar power conditioner for a built-in step-up chopper function. In the first step-up chopper proposed solar PV power conditioner for mutually connected in series with the input voltage of the bypass diodes are respectively connected to the positive terminal should install the mutual boosting chopper diode connected in series with the boost chopper switching element between the two power supply and at the same time the first and the second was connected to a second diode and a resonance inductor and a snubber capacitor in series with each other. And the common connection point between the bypass diode and the step-up chopper and the step-up chopper diode common connection point of the switching elements of the input voltage was set to the boost inductor for storing energy. In addition, between the step-up chopper and the step-up chopper diode and a switching element of a joint connection point of the first auxiliary diode and the second common connection point of the auxiliary diode was provided, the resonance capacitor. Between the step-up chopper and the step-up chopper diode and a switching element of a joint connection point and the common connection point of the resonance inductor snubber capacitor and connecting the third secondary diode, between two power supply lines is characterized by configuring the DC link capacitor bus lines in parallel. Therefore, it is possible to suppress the switching loss through, DC link bus lines, as well as there could seek miniaturization and weight reduction of the power conditioner itself by using a common capacitor of the non-polar non-polar electrolytic capacitor having a capacitor, the service life of the circuit can be extended and it is possible to greatly reduce the loss can be greatly improve the reliability of the product and the operation of the product itself.

A study on the Chopper Control System of Electroic Vehicle (전기자동차의 쵸퍼제어 방식)

  • Chung, Y.T.;Han, K.H.;Kim, Y.J.;Lee, S.H.;Kim, D.G.;Lee, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1182-1184
    • /
    • 1992
  • In case of chopper control is used for the d.c motor In the electric vehicle(EV) in general step down chopper is used for the driving and the step-up chopper is used for the regeneration. Bilateral variable ratio chopper system(BVRCS) formed by parallel combination of upper two chopper methods step-down, step-up and step-up/down chopper operations by duty cycle, circuit element and driving condition. In this paper, BVRCS is proposed for the simulated and experimented control of d.c motor in the EV. By the result of simulation BVRCS represents same driving power compared to the step-down and excellent breaking power compared to the step-up chopper system because of the greater motor current.

  • PDF

The Buckling Characteristics of Single-Layer Lamella Domes according to the Joint Flexibility under Construction (단층라멜라 돔의 시공 중 접합부 강성에 따른 좌굴특성)

  • Suk, Chang-Mok;Kim, Cheol-Hwan;Jung, Hwan-Mok
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.2
    • /
    • pp.111-118
    • /
    • 2011
  • Single-layer latticed domes with rigid-joint have an advantage in the construction cost and the aesthetic. But, in single-layer latticed domes, the joints are hard to discriminate between pin-joint and rigid-joint, and consisted of semi-rigid joint in practical. And the erection of large roof structures requires special techniques. As one of these special techniques is the Step-Up erection method. This paper verified buckling characteristics of single-Layer lamella domes according to the Joint flexibility under construction by Step-up method. The results are follows: As erection steps increase, the buckling strength decreases. It is occurred the joint buckling by snap through on the top of dome when the joint flexibility close the rigid. And large tensile stress distribution appeared in circumferential member of bottom boundary when the step of construction is low. As the step of construction increase, large compressive stress distribution showed in the top of dome.

A Three-Phase AC-DC High Step-up Converter for Microscale Wind-power Generation Systems

  • Yang, Lung-Sheng;Lin, Chia-Ching;Chang, En-Chih
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1861-1868
    • /
    • 2016
  • In this paper, a three-phase AC-DC high step-up converter is developed for application to microscale wind-power generation systems. Such an AC-DC boost converter prossessess the property of the single-switch high step-up DC-DC structure. For power factor correction, the advanced half-stage converter is operated under the discontinuous conduction mode (DCM). Simulatanously, to achieve a high step-up voltage gain, the back half-stage functions in the continuous conduction mode (CCM). A high voltage gain can be obtained by use of an output-capacitor mass and a coupled inductor. Compared to the output voltage, the voltage stress is decreased on the switch. To lessen the conducting losses, a low rated voltage and small conductive resistance MOSFETs are adopted. In addition, the coupled inductor retrieves the leakage-inductor energy. The operation principle and steady-state behavior are analyzed, and a prototype hardware circuit is realized to verify the performance of the proposed converter.

Symmetrical Cockcroft-Walton circuit for Transformerless High Step-Up DC-DC Converter (변압기 없는 고승압 직류 컨버터용 대칭형 Cockcroft-Walton 회로)

  • Cha, Dae-Joong;Baek, Ji-Eun;Ko, Kwang-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.8
    • /
    • pp.70-75
    • /
    • 2015
  • High Step-up DC-DC Converters have been demanded for renewable energy applications. Transformer or coupled inductor is generally used to boost output voltage of converters. This methods can relatively obtain high voltage than others, whereas have heavy weight and high cost. To complement these disadvantages, we studied transformerless high step-up DC-DC converter. In various transformerless topologies, Boost converters combined with Cockcroft-Walton have studied. In this paper, we proposed a symmetrical Cockcroft-Walton circuit for transformerless high step-up DC-DC converter. Finally, we simulated proposed converter to compare with existing converter. As a result, proposed converter has higher duty ratio or lower cost than existing transformerless converters which are discussed in this paper.

Effect of Protein Feeding Systems for Egg-type Growing Pullets on Pullet Growth, Nutrient Consumption and Subsequent Laying Performance (난용계 육성기의 단백질 공급체계가 육성계의 성장 및 영양소 섭취량과 산란능력에 미치는 영향)

  • 이규호;정연종
    • Korean Journal of Poultry Science
    • /
    • v.21 no.4
    • /
    • pp.257-266
    • /
    • 1994
  • Three protein feeding systems for egg-type pullets involving conventional step-down protein 18-15-12%), step-up protein(12-15-18%) and single-stage low protein (13-13-13%) with an iso-energy level of 2,900 ME kcal /kg were compared to examine the effect on pullet growth and subsequent laying performance. During the growing period, pullets subjected to the step-up and single-stage low protein feeding systems were lighter in body weight and consumed less feed and netabolizable energy than those on the conventional step-down protein feeding system(P<0.05). 3ut the pullets on the step-up protein diet consumed more protein, and those on the single-stage low protein diet consumed less protein than those on the step-down protein diet(P<0.05). Also, he feed cost was less in pullets on the single-stage low protein diet than in those on the other systems(P<0.05). During the laying period, sexual maturity was later in hens reared on the step-up and single-stage low protein diets than in those on the step-down protein diet(P<0.05), however, average hen-day egg production and egg weight were not significantly affected by the protein feeding systems in the growing period. Daily feed intake and feed required per egg were significantly reduced in hens on the single-stage low protein diet compared to those on conventional protein feeding system(P<0.05). It was concluded that the 13% single-stage low protein feeding system produced smaller pullets with less feed, energy, protein, and feed cost during the growing period, and hens reared on that system consumed less feed during the laying period without any impairment of production compared to the conventional rearing system.

  • PDF