• Title/Summary/Keyword: step by step

Search Result 16,141, Processing Time 0.049 seconds

Development of salt-tolerant transgenic chrysanthemum (Dendranthema grandiflorum) lines and bio-assay with a change of cell specificity (내염성 국화 형질전환 계통 육성 및 저항성 검정과 세포특성 변화)

  • Kang, Chan-Ho;Yun, Seung-Jung;Han, Bum-So;Lee, Gong-Joon;Choi, Kyu-Hwan;Park, Jong-Suk;Shin, Yong-Kyu
    • Journal of Plant Biotechnology
    • /
    • v.38 no.1
    • /
    • pp.1-8
    • /
    • 2011
  • Recently the increasing of vinyl and green houses and development of reclaimed land including Saemangeum induced the need for breeding salt-tolerant crops which can survive and grow in high salinity soil. So we try to develop salt-tolerant transgenic chrysanthemum (Dendranthema grandiflorum.) lines by using anti-porter gene TANHX and HVNHX. Through marker selection and plant regeneration step, we could get 284 putative transgenic chrysanthemum lines. On selected putative transgenic plants, 40 candidates were used for genetic analysis and 30 lines could be made up of target size band on PCR, so about 75% of marker selected lines were decided as real transgenic lines. Selected 284 transgenic lines were also used for salt-tolerance test as a range of NaCl 0.2 ~ 1.2% (300 mM). As a result of salt-tolerance test, 15 selected transgenic lines could live and grow on the continuous supply of 0.8% (200 mM) NaCl solution and another 7 lines were could survive under 1.2% (300 mM) NaCl solution. This salt-tolerant transgenic lines under salt stress also lead a cell alternation especially a guard cell. A stressed guard cell be swelled and grow larger in proportion to NaCl concentration. TTC test for cell viability on transgenic chrysanthemum lines pointed out that more strong salt-tolerant lines can be live more than another under same salt stress. The numerical value of strong salt-tolerant 7 transgenic lines were 0.206 ~ 0.331 under 1.2% NaCl stress, and then it's value is more larger than middle salinity lines' 0.114 ~ 0.193 and non-transgenic's 0.046. And the proline contents as indicated stress compound also pointed out that HVNHX introduced salt-tolerant transgenic lines were less stressed than other under same salt stress. The contents of strong salt-tolerant transgenic lines were 2.255 ~ 2.638 mg/kg and it is much higher than that of middle salinity lines' 1.496 ~ 2.125.

Partial Purification of OsCPK11 from Rice Seedlings and Its Biochemical Characterization (벼 유식물에서 OsCPK11의 부분 정제 및 생화학적 특성 규명)

  • Shin, Jae-Hwa;Kim, Sung-Ha
    • Journal of Life Science
    • /
    • v.30 no.2
    • /
    • pp.137-146
    • /
    • 2020
  • Calcium is one of the important secondary signaling molecules in plant cells. Calcium-dependent protein kinases (CDPK)-the sensor proteins of Ca2+ and phosphorylating enzymes-are the most abundant serine/threonine kinases in plant cells. They convert and transmit signals in response to various stimuli, resulting in specific responses in plants. In rice, 31 CDPK gene families have been identified, which are mainly involved in plant growth and development and are known to play roles in response to various stress conditions. However, little is known about the biochemical characteristics of CDPK proteins. In this study, OsCPK11-a CDPK in rice-was partially purified, and its biochemical characteristics were found. Partially purified OsCPK11 from rice seedlings was obtained by three-step column chromatography that involved anion exchange chromatography consisting of DEAE, hydrophobic interaction chromatography consisting of phenyl-Sepharose, and gel filtration chromatography consisting of Sephacryl-200HR. An in vitro kinase assay using partially purified OsCPK11 was also performed. This partially purified OsCPK11 had a molecular weight of 54 kDa and showed a strong hydrophobic interaction with the hydrophobic resin. In vitro kinase assay showed that the OsCPK11 also had Ca2+-dependent autophosphorylation activity. The OsCPK11 phosphorylated histone III-S, and the optimum pH for its kinase activity was found to be 7.5~8.0. The native OsCPK11 shared several biochemical characteristics with recombinant OsCPK11 studied previously, and both had Ca2+-dependent autophosphorylation activity and favored histone III-S as a substrate for kinase activity, which also had a Ca2+-dependence.

Clinical Features of Enuresis in Children with Diabetes Mellitus (소아 당뇨병 환아에서 야뇨증의 임상적 특징)

  • Kim, Myoung-Uk;Kim, Sae-Yoon;Choi, Jung-Youn;Cho, Min-Hyun;Ko, Cheol-Woo;Kim, Heung-Sik;Park, Yong-Hoon
    • Childhood Kidney Diseases
    • /
    • v.14 no.2
    • /
    • pp.210-217
    • /
    • 2010
  • Purpose : Diabetes mellitus (DM) is known as one of the common causes of secondary enuresis in children. However, enuresis in diabetic children is overlooked only as a symptom of polyuria due to hyperglycemia. We evaluated the prevalence of nocturnal enuresis in children with diabetes mellitus in this paper. Methods : Among children with diabetes in three hospitals in Daegu area, 117 agreed to 'Tele research by means of a questionnaire'. Results : Diabetic patients were divided into two groups: Nocturnal enuresis and nonnocturnal enuresis group. thirty-two of 117 (27.0%) patients were in enuresis group, with more daytime urination than non-nocturnal enuresis group ($4.2{\pm}1.6/3.6{\pm}1.2$ times, P=0.016). HbA1c at diagnosis was $12.0{\pm}2.3%/12.0{\pm}2.5%$, and at follow-up $9.3{\pm}2.3%/8.3{\pm}2.3%$ (P =0.042). Insulin was administered at $1.1{\pm}0.5/1.1{\pm}0.4$ units/kg/day. Ten children of enuresis (31.2%) group were monosymptomatic (MNE) and 22 (68.8%) children were non-monosymptomatic enuresis (non-MNE). Fourteen (43.8%) of enuresis group had persistent symptoms, with 5 MNE and 9 non-MNE each. HbA1c at diagnosis was $11.1{\pm}2.5$, $12.4{\pm}2.1$, higher in non-MNE (P=0.144). Average arousal during sleep was step $3.3{\pm}1.2$, $2.5{\pm}1.0$, higher in improved enuresis group (P=0.059). Conclusion : Nocturnal enuresis among DM patients is underestimated. However, considering psychological and social effects of enuresis in children, extensive and long-term studies are needed in the future to clarify relationship between prevalence and DM control.

Comparison between the Calculated and Measured Doses in the Rectum during High Dose Rate Brachytherapy for Uterine Cervical Carcinomas (자궁암의 고선량율 근접 방사선치료시 전산화 치료계획 시스템과 in vivo dosimetry system 을 이용하여 측정한 직장 선량 비교)

  • Chung, Eun-Ji;Lee, Sang-Hoon
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.396-404
    • /
    • 2002
  • Purpose : Many papers support a correlation between rectal complications and rectal doses in uterine cervical cancer patients treated with radical radiotherapy. In vivo dosimetry in the rectum following the ICRU report 38 contributes to the quality assurance in HDR brachytherapy, especially in minimizing side effects. This study compares the rectal doses calculated in the radiation treatment planning system to that measured with a silicon diode the in vivo dosimetry system. Methods : Nine patients, with a uterine cervical carcinoma, treated with Iridium-192 high dose rate brachytherapy between June 2001 and Feb. 2002, were retrospectively analysed. Six to eight-fractions of high dose rate (HDR)-intracavitary radiotherapy (ICR) were delivered two times per week, with a total dose of $28\~32\;Gy$ to point A. In 44 applications, to the 9 patients, the measured rectal doses were analyzed and compared with the calculated rectal doses using the radiation treatment planning system. Using graphic approximation methods, in conjunction with localization radiographs, the expected dose values at the detector points of an intrarectal semiconductor dosimeter, were calculated. Results : There were significant differences between the calculated rectal doses, based on the simulation radiographs, and the calculated rectal doses, based on the radiographs in each fraction of the HDR ICR. Also, there were significant differences between the calculated and measured rectal doses based on the in-vivo diode dosimetry system. The rectal reference point on the anteroposterior line drawn through the lower end of the uterine sources, according to ICRU 38 report, received the maximum rectal doses in only 2 out of the nine patients $(22.2\%)$. Conclusion : In HDR ICR planning for conical cancer, optimization of the dose to the rectum by the computer-assisted planning system, using radiographs in simulation, is improper. This study showed that in vivo rectal dosimetry, using a diode detector during the HDR ICR, could have a useful role in quality control for HDR brachytherapy in cervical carcinomas. The importance of individual dosimeters for each HDR ICR is clear. In some departments that do not have the in vivo dosimetry system, the radiation oncologist has to find, from lateral fluoroscopic findings, the location of the rectal marker before each fractionated HDR brachytherapy, which is a necessary and important step of HDR brachytherapy for cervical cancer.

Evaluation of Biocompatibility of Extracorporeal Circuit - Development of a Quantification Technique using in-vivo Injection of Tc99m Radioactive Platelets - (체외순환도관의 혈액적합성 평가 - 방사선 동위원소(Tc99m) 활성화 혈소판의 생체 내 주입을 이용한 정량분석법의 개발 -)

  • Lee, Sung-Ho;Sun, Kyung;Choi, Jai-Geol;Son, Ho-Sung;Jung, Jae-Seung;Ahn, Sang-Soo;Oh, Hye-Jung;Lee, Whan-Sung;Lee, Hye-Won;Kim, Kwang-Taik;Jeong, Yoon-Seop;Kim, Young-Ha;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.171-176
    • /
    • 2002
  • Background: Blood-foreign interaction cause activation of coagulation and inflammatory process that may lead to multiorgan dysfunction and determine the surgical outcomes. Of the methods for assessing the biocompatibility, the platelet adhesion study is considered as the most valuable evaluation step in blood-foreign interaction. As the most studies have used in-vitro or ex-vivo conditions, we have developed a technique of quantification for platelet adhesion on the blood contact surface by using in-vivo injection of radioactive platelets. Material and Method: A coupled bypass circuit was designed to connect the proximal and descending thoracic aorta in 6 piglets(20∼25 Kg). One side of the circuit tube was consisted of a heparin coated PVC tube(10mm in ID, n=6, Experimental group), and the other, a non-heparin coated PVC tube(10mm in ID, n=6, Control group). After cannulation, the blood was circulated through the circuit for 2 hours. Platelet concentrate was prepared from homologous pig blood 24 hours before the experiment. The platelet concentrate was incubated with Tc-99m-HMPAO for 30 min and then centrifuged for 10 min. The supernatant was discarded and the radio-labeling efficacy was measured. The radio-labeled platelet concentrate was mixed with the autologous plasma to make the volume 5 ml, and the mixture was injected intravenously into the experimental animal. After 2 hour circulation, 5 pieces of the specimen(10mm in length each) were obtained from each PVC tube. The radioisotopes were counted with a gamma counter(Cobra ll, Packard, USA), and the ratio of radioisotope count was compared between the control and experimental group. Result: The radioisotope count number was 537.3221.1 Ci/min in the control group and 311.1 184.5 Ci/min in the experimental group(p=0.0104). The ratio between the groups was 1 to 0.58 (p=0.004). Conclusion: In vivo quantification using technetium-99m-HMPAO labeled platelets is simple and reproducible in evaluating platelet adhesion on a foreign surface. We suggest this technique to be a useful tool for blood compatibility test.

The Evaluation of Images with Various Filters in I-131 SPECT/CT (I-131 SPECT/CT에서 Ringing Artifact 감소를 위한 다양한 Filter값의 적용)

  • Kim, Ha Gyun;Kim, Soo Mee;Woo, Jae Ryong;Oh, So Won;Lee, Jae Sung;Kim, Yu Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.62-68
    • /
    • 2014
  • Purpose: After I-131 therapy, SPECT/CT is useful in identifying location of thyroid remnants and metastasis of thyroid cancers. An excessive uptake of thyroid leads to a ringing artifact in the SPECT images. The aim of this study is to investigate and suggest a proper post filters to remove ringing artifact and produce better image quality. Materials and Methods: A low-cost, customized thyroid-mimicking phantom, consisting of an acrylic bottle and a hollow sphere was used for SPECT/CT Discovery (GE Healthcare, USA). It was filled with I-131 solution. The ratio of hollow sphere to background were varied as 50:1, 200:1, 1000:1 and 4000:1. Acquired images were reconstructed by OSEM (2 iterations, 10 subsets) with and without Evolution (resolution recovery correction, GE). Three different post-filters were applied; Butterworth (cut off: 0.38 to 0.58 with intervals of 0.05), Hanning (cut off: 0.8 to 1 with intervals of 0.05) and Gaussian (FWHM: 3 to 5 with intervals of 0.5) filters. Contrast, background variability, air area variability, and full width half maximum (FWHM) were compared. Results: Higher contrasts were obtained from the SPECT images with Evolution than without Evolution. In the case of images without Evolution, image distortion such as star artifact was generated. For all sphere-to-background ratio, the Butterworth filter showed better constrasts and FWHMs than other two filters, but the ringing artifact was still generated in all studies except 50:1 and it was decreased as cutoff value was increased. The ringing artifact didn't appear with Hanning and Gaussian filters at all studies, however constrats and FWHMs with Gaussian was worse than Hanning filter. For the images having ringing artifacts, the background variability and air area variability were increased. Conclusion: In this study, we suggested that it is desirable to use Hanning filter when the ringing artifact is generated and to use Butterworth filter when ringing artifact is not generated in I-131 SPECT.

  • PDF

Survey on the Awareness of Guardians of Young Infants on the Weaning of Food in Pohang and Gyeongju Area (두 종합 병원을 방문한 영유아 양육자의 이유식에 대한 인지도 조사)

  • We, Hyun Woo;Seo, Yu Kyung;Kim, Ae Suk;Lee, Sun Ju;Cho, Sung Min;Lee, Dong Seok;Kim, Doo Kwun;Choi, Sung Min
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.9 no.2
    • /
    • pp.233-241
    • /
    • 2006
  • Purpose: This study was carried out to investigate the awareness of the weaning of food using questionnaires, and the relationship with the weight gain in young infants. Methods: From September 2005 to December 2005, we performed a survey on 141 guardians of young infants aged from 6 to 18 months, who visited the pediatric out-patient department at Dongguk University Medical Center. We calculated the total score for each responder from ten questions on the weaning of food and assessed the body weight percentile of each of the young infants. Results: The most commonly reported information source for weaning food was 'the friends around' by 62 respondents (44.0%); 54 (38.3%) responded that the definition of weaning food was the preparatory step before starting a solid diet. Most used a spoon (90.8%) to feed when weaning food with a thin gruel of rice (78.7%). The time for weaning of food was before breast or infant formula feeding (55.3%). Addition of cow's milk was around 12 months (77.3%). The mean score was 6.21; however this did not show a statistically significant correlation with weight gain in young infants. Conclusion: The overall awareness of weaning of food has improved; however, information from doctors has decreased. Although the relationship between the awareness of weaning of food and the growth of young infants was not statistically significant, further studies on weaning of food, with larger and controlled sample sizes may provide important information.

  • PDF

Ni/Au Electroless Plating for Solder Bump Formation in Flip Chip (Flip Chip의 Solder Bump 형성을 위한 Ni/Au 무전해 도금 공정 연구)

  • Jo, Min-Gyo;O, Mu-Hyeong;Lee, Won-Hae;Park, Jong-Wan
    • Korean Journal of Materials Research
    • /
    • v.6 no.7
    • /
    • pp.700-708
    • /
    • 1996
  • Electroless plating technique was utilized to flip chip bonding to improve surface mount characteristics. Each step of plating procedure was studied in terms pf pH, plating temperature and plating time. Al patterned 4 inch Si wafers were used as substrstes and zincate was used as an activation solution. Heat treatment was carried out for all the specimens in the temperature range from room temperature to $400^{\circ}C$ for $30^{\circ}C$ minutes in a vacuum furnace. Homogeneous distribution of Zn particles of size was obtained by the zincate treatment with pH 13 ~ 13.5, solution concentration of 15 ~ 25% at room temperature. The plating rates for both Ni-P and Au electroless plating steps increased with increasing the plating temperature and pH. The main crystallization planes of the plated Au were found to be (111) a pH 7 and (200) and (111) at pH 9 independent of the annealing temperature.

  • PDF

Suggestion for Technology Development and Commercialization Strategy of CO2 Capture and Storage in Korea (한국 이산화탄소 포집 및 저장 기술개발 및 상용화 추진 전략 제안)

  • Kwon, Yi Kyun;Shinn, Young Jae
    • Economic and Environmental Geology
    • /
    • v.51 no.4
    • /
    • pp.381-392
    • /
    • 2018
  • This study examines strategies and implementation plans for commercializing $CO_2$ capture and storage, which is an effective method to achieve the national goal of reducing greenhouse gas. In order to secure cost-efficient business model of $CO_2$ capture and storage, we propose four key strategies, including 1) urgent need to select a large-scale storage site and to estimate realistic storage capacity, 2) minimization of source-to-sink distance, 3) cost-effectiveness through technology innovation, and 4) policy implementation to secure public interest and to encourage private sector participation. Based on these strategies, the implementation plans must be designed for enabling $CO_2$ capture and storage to be commercialized until 2030. It is desirable to make those plans in which large-scale demonstration and subsequent commercial projects share a single storage site. In addition, the plans must be able to deliver step-wised targets and assessment processes to decide if the project will move to the next stage or not. The main target of stage 1 (2019 ~ 2021) is that the large-scale storage site will be selected and post-combustion capture technology will be upgraded and commercialized. The site selection, which is prerequisite to forward to the next stage, will be made through exploratory drilling and investigation for candidate sites. The commercial-scale applicability of the capture technology must be ensured at this stage. Stage 2 (2022 ~ 2025) aims design and construction of facility and infrastructure for successful large-scale demonstration (million tons of $CO_2$ per year), i.e., large-scale $CO_2$ capture, transportation, and storage. Based on the achievement of the demonstration project and the maturity of carbon market at the end of stage 2, it is necessary to decide whether to enter commercialization of $CO_2$ capture and storage. If the commercialization project is decided, it will be possible to capture and storage 4 million tons of $CO_2$ per year by the private sector in stage 3 (2026 ~ 2030). The existing facility, infrastructure, and capture plant will be upgraded and supplemented, which allows the commercialization project to be cost-effective.

INFLUENCES OF APICOECTOMY AND RETROGRADE CAVITY PREPARATION METHODS ON THE APICAL LEAKAGE (치근단절제 및 역충전와동 형성방법이 치근단누출에 미치는 영향)

  • Yang, Jeong-Ok;Kim, Sung-Kyo;Kwon, Tae-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.537-549
    • /
    • 1998
  • The purpose of this study was to evaluate the influence of root resection and retrograde cavity preparation methods on the apical leakage in endodontic surgery. To investigate the effect of various root resection and retrograde cavity preparation methods on the apical leakage, 71 roots of extracted human maxillary anterior teeth and 44 mesiobuccal roots of extracted human maxillary first molars were used. Root canals of the all the specimens were prepared with step-back technique and filled with gutta-percha by lateral condensation method. Three millimeters of each root was resected at a 45 degree angle or perpendicular to the long axis of the tooth according to the groups. Retrograde cavities were prepared with ultrasonic instruments or a slow-speed round bur, and occlusal access cavities were filled with zinc oxide eugenol cement. Three coats of clear nail polish were placed on the lateral and coronal surfaces of the specimens except the apical cut one millimeter. All the specimens were immerged in 2% methylene blue solution for 7 days in an incubator at $37^{\circ}C$. The teeth were dissolved in 14 ml of 35% nitric acid solution and the dye present within the root canal system was returned to solution. The leakage of dye was quantitatively measured via spectrophotometric method. The obtained data were analysed statistically using two-way ANOVA and Duncans Multiple Range Test. The results were as follows: 1. No statistically significant difference was observed between ultrasonic retrograde cavity preparation method and slow-speed round bur technique, without apical bevel (p>0.05). 2. Ultrasonic retrograde preparation method showed significantly less apical leakage than slow-speed round bur technique, with bevel (p<0.0001). 3. No statistically significant difference was found between beveled resected root surface and non-beveled resected root surface, with ultrasonic technique (p>0.05). 4. Non-beveled resected root surface showed significantly less apical leakage than beveled resected root surface, with slow-speed round bur technique (p<0.0001). 5. No statistically significant difference in apical leakage was found between the group of retrograde cavity prepared parallel to the long axis of the tooth and the group of one prepared perpendicular to the long axis of the tooth (p>0.05). 6. Regarding isthmus preparation, ultrasonic retrograde preparation method showed significantly less apical leakage than slow-speed round bur technique, in the mesiobuccal root of maxillary molar, without bevel (p<0.0001).

  • PDF