• Title/Summary/Keyword: steel property

Search Result 969, Processing Time 0.032 seconds

Mechanical Properties of Ta/TaN Multilayer (Ta/TaN 복합 다층 피막의 기계적 특성)

  • Gang, Yeong-Gwon;Lee, Jong-Mu;Choe, Sang-Uk
    • Korean Journal of Materials Research
    • /
    • v.9 no.8
    • /
    • pp.837-842
    • /
    • 1999
  • The Ta/TaN multilayer structure with repeating layers of a poly-crystalline Ta layer of high ductility and a TaN layer of high hardness is expected to exhibit toughness. This paper reports the results on the hardness and the adhesion strength of Ta/TaN multilayers and compositional gradient Ta/TaN layers deposited on the high speed steel substrate by reactive sputtering as a function of annealing temperature. The TaN film deposited with the $N_2$/Ar ratio of 0.4 in the reactive sputtering process exhibits the highest crystallinity, and the highest hardness and the results of scratch test of the Ta/TaN multilayers. The hardness and adhesion strength of the Ta/TaN multilayers becomes deteriorated with increasing the annealing temperature in the heat treatment right after depositing the layers. Therefore, post-annealing treatments are not desirable in the case of the Ta/TaN multilayers from the standpoint of mechanical properties. Also the hardness of Ta/TaN multilayers increases with decreasing the compositional modulation wavelength, but the adhesion property of the layers is nearly independent of the wavelength. On the other hand, the compositional gradient Ta/TaN film exhibits the highest hardness and the value of scratch test for the post-annealing temperatures of 20$0^{\circ}C$ and 40$0^{\circ}C$, respectively. This tendency of the compositional gradient Ta/TaN films differs from that of the Ta/TaN multilayers.

  • PDF

A Study on the Preservation Method of Modern Registered Architectural Cultural Properties (근대건축 등록문화재의 보존 방안에 관한 연구)

  • Shin, Woong-Ju;Lee, Sang-Sun
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.16 no.1
    • /
    • pp.119-127
    • /
    • 2014
  • This study suggests institutional and methodological approaches for preservation of South Korea's registered cultural properties of modern architecture. The suggested approaches are as follows. First, in order to improve the current registration and preservation system for cultural properties, we need to employ both structure-based classification and style-based classification. Registration criteria for modern architecture properties need to include more detailed classification in terms of their structure: brick structure, steel concrete structure and post lintel structure. In terms of construction style, the properties need to be further classified into the western style, the traditional style and the Korean-western eclectic style. In addition, protection of registered cultural properties need to be achieved through legislation of a protection system. Second, while the current system sets out six methods for preservation of registered cultural properties of modern architecture, more specific preservation methods types and plans need to be continuously introduced. In particular, as for the method of partial preservation, the method needs to be further classified based on the usage of the relevant structure so as to allow for more diverse options. First, the 'Preservation by Interior Alteration' needs to be added to the category, where the exterior is preserved as it is and the interior is preserved through alteration. Also needs to be added the preservation method where the interior space is preserved as it is and the exterior space is altered, in case the finishing materials of the exterior has deteriorated. Third, if the records on registered cultural properties of modern architecture are to provide the functions of legal evidences regarding management of architectural cultural properties, sources of knowledge required for policy making and implementation and past management record for the future, each phase needs to be closely connected in an organic manner, and we need to establish a management system and plan that go beyond the relevant organizations. Fourth, in order to preserve South Korea's registered cultural properties of modern architecture in its original state, it is imperative to prepare separate criteria for registration of technicians with expertise on modern architecture, and train experts and technicians on modern architecture, which is distinguished from the traditional architecture.

Changes of Properties and Gas Components according to Accelerated Aging Test of Vegetable Transformer Oil (식물성 절연유의 가속열화에 따른 주요 성분 및 물성 변화)

  • Lee, Donmin;Lee, Mieun;Park, Cheonkyu;Ha, Jonghan;Park, Hyunjoo;Jun, Taehyun;Lee, Bonghee
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.18-26
    • /
    • 2016
  • Mineral oil is the most widely used for electrical transformer, though some factors should be considered such as their environmentally harmfulness when it spill and low flash point. To cover these disadvantages, vegetable oil has developed because of its high biodegradability and thermal stability. However, it is necessary that many studies should conduct to reveal the detailed impacts of long-term operation as transformer oil. In this paper, we applied the accelerated aging test which simulate the real transformer circumstances using insulation paper, coil, steel at $150^{\circ}C$, which is higher than normal operation, for 2 weeks. To figure out the oxidation characteristics between mineral oil and vegetable oil test major properties and components such as total acid number, dielectric breakdown and dissolved gas components during that period. As a result of these tests, we found that vegetable oil has higher electric insulation ability than mineral oil though poor total acid number by hydrophile property. Vegetable oil also kept its thermal stability under the given circumstances.

Effect of Drift Pin Arrangement for Strength Property of Glulam Connections (드리프트 핀의 배열 형태가 집성재 접합부의 회전 거동 및 강도 성능에 미치는 영향)

  • Lee, In-Chan;Park, Chun-Young;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.10-21
    • /
    • 2007
  • It is necessary to study about moment performance of glulam-dowel connections which had been applied rotation. To analyze and predict the moment performance, angled to grain load was replaced with parallel to grain load and perpendicular to grain load. The dowel bending strength and dowel bearing strength were tested. And tensile strength test for connections of two different end distances was performed. Specimens of rotation test were composed with different drift pin numbers and drift pin arrangement. Connection deformation was occurred by plastic behavior of drift pin after yield when tensile load applied at connection. And the absorbing drift pin deflection by end distance continued the connection deformation. When rotation applied at connection that 2 drift pins were arranged parallel to grain (b2h), it showed similar performance with tensile perpendicular to grain. And connection that 2 drift pins were arranged perpendicular to grain (b2v) showed similar performance with tensile parallel to grain. Connection capacity that 4 drift pins were arranged rectangular (b4) showed 1.7 times as strong as connection that 2 drift pins were arranged parallel to grain (b2h). These results agreed predicted values and it is available that rotation replaced with tensile load.

An Experimental Study on Fire Spreading External Wall of Buildings Using Dry Construction Method (건식공법을 이용한 건축물의 외벽 화재 확산의 실험적 연구)

  • Park, Jung-Woo;Cho, Nam-Wook
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.75-85
    • /
    • 2018
  • The Grenpell tower fire in England in June of 2016 is a representative example of damage caused by a vertical fire spreading through external insulation. Organic insulation materials, which are widely used in external insulation, have the disadvantage that they have good insulation performance but are vulnerable to fire. Aluminum composite panels are used as exterior wall finishing materials, and plastics used in aluminum are regarded as the cause of vertical fire spread. Due to the steel frame used to secure the aluminum composite panel to the outer wall, a cavity is formed between the outer wall and outer wall finish. When a fire occurs on the outer wall, the flammable outer wall as well as the flame generated from the heat-insulating material spreads vertically through the cavity, resulting in damage to people and property. In Korea, material unit performance tests are carried out by the Ministry of Land, Infrastructure and Transport notice 2015 - 744. However, in the UK, the BS 8414 test is used to measure the vertical fire spreading time on the outer wall in real scale fire tests. In this study, the risk of external wall fire was evaluated in an actual fire by conducting a real scale wall fire test (BS 8414), which was carried out in Europe, using aluminum composite panels of semi-noncombustible materials suitable for current domestic standards. The purpose of this study was to confirm the limitations of material unit evaluation of finishing materials and to confirm the necessity of introducing a system to prevent the spread of outer wall fire through an actual scale fire test.

A Study on the Iron Compounds of Cinder Cones' Scoria in the Southern Area of Halla Mt., Jeju Island (제주도 한라산 남부 지역 분석구 스코리아의 철 화합물에 관한 연구)

  • Ko, Jeong Dae;Choi, Won Jun
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.6
    • /
    • pp.213-218
    • /
    • 2016
  • This study reviewed mineral composition on Scoria samples of this area, atomic value state of oxidized steel, and magnetic property in order to look into characteristics of scoria that was distributed in southern area of mountainous areas, Halla Mt. of Jeju Island. By XRD analysis, mineral composition was confirmed, and characteristics of iron compounds existed in samples were investigated through $M{\ddot{o}}ssbauer$ spectroscope. Composing minerals could be learnt as feldspar basalt from XRD analysis because composting minerals were composed of quartz and feldspar anorite mainly, and iron compounds were made up with olivine, pyroxene, ilmenite, hematite, and magnetite. By $M{\ddot{o}}ssbauer$ spectroscope analysis on these iron compounds. it consisted of hematite and magnetite which showed hyperfine magnetic field of sextet mostly, and also doublet by olivine, pyroxene, ilmenite could be seen as appearing together. As a result of comparing with samples of Jeju western area having been announced in previous research, I.S. and Q.S. values of olivine, $Fe^{2+}$, were 122 mm/s and 3.09~3.13 mm/s respectively, and a fact could be known that $Fe^{2+}$ olivine having similar structure each other was contained, and the ratio of $Fe^{3+}/Fe_{tot.}$. was 85.90~92.82 %. From these findings, it was able to be presumed that they belonged to samples having been formed on the land at the same period of time. As a result of investigating area ratio of tetrahedron (A site) and octahedron (B site) regarding magnetite in samples, it was turn out to be 0.22~0.55 less than 2.

Study on Stable Use of Stainless EAF Oxidizing Slag as Fine Aggregate of Concrete (스테인리스 전기로 산화슬래그의 콘크리트용 잔골재 활용방안 검토)

  • Cho, Bong-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.133-142
    • /
    • 2014
  • Recently, more focus is shift to imbalances in aggregate market supply and demand and an exhaustion of natural resources. In this situation, Electric arc furnace oxidizing slag (EAF Slag) has high application possibility as aggregate for concrete due to similar property with general aggregate. In this study, We've got the plan to assure the chemical stability of EAF Slag, and then experimentally tested the mechanical performance and durability for the fine aggregate used EAF Slag. On this test result, we suggest the application plan. At the result of this study, it shows that EAF slag would reduce the surface defect such as pop-out due to natural aging for the fixed hour and adjustment the grain size of EAF Slag. And mechanical performance and durability according to the replacement rate of concrete service, were revealed more than equal or equal compare to general aggregate. Hereafter, quality control must precede not to impede the beauty of concrete surface as assure the safety for aging and processing. And, to establish the environmental resource recycling system for by-products of steel, it should be made development of various application and guideline of quality control for the EAF slag aggregate. Moreover, it must be constantly studied all kind of engineering performance and durability for related to this study.

Effect of the Heat Treatment on the Mechanical Property and Corrosion Resistance of CU - 7Al - 2.5Si Alloy (Cu-7Al-2.5Si 합금의 기계적 및 내식특성에 미치는 열처리 효과)

  • Lee, Syung-Yul;Won, Jong-Pil;Park, Dong-Hyun;Moon, Kyung-Man;Lee, Myeong-Hoon;Jeong, Jin-A;Baek, Tae-Sil
    • Corrosion Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.28-35
    • /
    • 2014
  • Recently, the fuel oil of diesel engines of marine ships has been increasingly changed to heavy oil of low quality as the oil price is getting higher and higher. Therefore, the spiral gear attached at the motor of the oil purifier which plays an important role to purify the heavy oil is also easy to expose at severe environmental condition due to the purification of the heavy oil in higher temperature. Thus, the material of the spiral gear requires a better mechanical strength, wear and corrosion resistance. In this study, the heat treatment(tempering) with various holding time at temperature of $500^{\circ}C$ was carried out to the alloy of Cu-7Al-2.5Si as centrifugal casting, and the properties of both hardness and corrosion resistance with and without heat treatment were investigated with observation of the microstructure and with electrochemical methods, such as measurement of corrosion potential, cathodic and anodic polarization curves, cyclic voltammogram, and a.c. impedance. in natural seawater solution. The ${\alpha}$, ${\beta}^{\prime}$ and ${\gamma}_2$ phases were observed in the material in spite of no heat treatment due to quenching effect of a spin mold. However, their phases, that is, ${\beta}^{\prime}$ and ${\gamma}_2$ phases decreased gradually with increasing the holding time at a constant temperature of $500^{\circ}C$. The hardness more or less decreased with heat treatment, however its corrosion resistance was improved with the heat treatment. Furthermore, the longer holding time, the better corrosion resistance. In addition, when the holding time was 48hrs, its corrosion current density showed the lowest value. The pattern of corroded surface was nearly similar to that of the pitting corrosion, and this morphology was greatly observed in the case of no heat treatment. It is considered that ${\gamma}_2$ phase at the grain boundary was corroded preferentially as an anode. However, the pattern of general corrosion exhibited increasingly due to decreasing the ${\gamma}_2$ phase with heat treatment. Consequently, it is suggested that the corrosion resistance of Cu-7Al-2.5Si alloy can be improved with the heat treatment as a holding time for 48 hrs at $500^{\circ}C$.

Basic Study on the Regenerator of Stirling Engine (III) - Temperature Distribution and Pressure drop property of the regenerator with steel wire - (스털링 기관용 재생기에 관한 기초 연구(III) - 철선을 축열재로 한 재생기의 온도 분포와 압력 강하 특성 -)

  • 김태한;오대건;이정택
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.548-557
    • /
    • 2002
  • 본 연구는 스털링 기관의 성능에 가장 큰 영향을 미치는 재생기의 설계에 적합한 축열재를 찾을 목적으로 단일 철선 종류(ø0.7, ø0.9, ø1.2, ø1.6, ø2.0, ø2.7), 복합 철선 4종류 (ø1.6-ø1.2, ø1.2-ø1.6, ø0.9-ø1.2, ø1.2-ø0.9), 철망-철선을 서로 다르게 혼합한 축열재 8종류(150-ø0.9, 150-ø01.2, ø0.9-150, ø1.2-150, 150-ø0.9-150, 150-ø1.2-150, 150-ø1.6-150, 150-ø2.0-150)을 공시 축열재로 하여 스털링 기관의 운전조건과 동일한 왕복 유동 상태에서 축열재의 삽입 방법에 따른 온도 분포 및 압력 강하 특성에 관한 실험을 수 행한 결과를 요약하면 다음과 같다. 1. 단일 철선을 축열재로 사용한 경우, 재생기 양단의 온도차는 단일 철선의 직경이 작을수록 커지는 경향을 보였으나, 양단의 압력 차는 단일 철선의 직경이 커질수록 작아졌다. 단일 철선 ø0.7과 ø0.9의 성능은 이들 2종류의 공시 축열재의 성능을 비교하기 위하여 재생기 양단의 온도차 증가에 따른 기관의 압력증가량과 압력강하 곡선의 차를 비교한 결과, 거의 비슷함을 알 수 있었으며 최적치를 나타냈다. 2. 복합 철선 4종류의 경우, 가열부 쪽에 ø1.2, 냉각부 쪽에 ø0.9를 삽입한 것이 반대로 삽입한 것보다 재생기 양단의 온도차가 큰 반면, 압력 차는 적으므로 재생기 축열재로서 더 적합한 것으로 나타났다. 복합 철선을 사용할 경우 가열부 쪽보다 냉각부 쪽에 철선 직경이 작은 것을 삽입하는 것이 효과적임을 알 수 있다. 또한 철선의 직경이 큰 것의 조합보다는 직경이 작은 철선의 조합이 재생기 양단의 온도차가 큼을 알 수 있다. 3. 철망-철선 혼합재를 축열재로 사용할 경우 재생기를 반으로 나누어서 가열부 쪽에 철선을, 냉각부 쪽에 철망을 삽입한 것이 반대로 삽입한 것보다 재생기 양단의 온도차는 높게 나타났고, 재생기 양단의 압력 차는 낮게 나타났다. 재생기 축열재로서 철망-철선을 사용할 경우 철선-철망 ø1.2-150이 전열 표면적은 작으나 재생기 양단의 온도차가 가장 큰 것으로 나타났으며 재생기 양단의 압력 차는 가장 낮게 나타나 공시 철망- 철선 혼합 축열재중 가장 우수함을 알 수 있다. 4. 철망사이에 철선을 삽입한 축열재의 경우, 철망사이에 삽입한 철선의 직경이 큰 것이 철선의 직경이 작은 것보다 재생기의 양단의 온도차가 높게 나타났고 재생기 양단의 압력차는 작게 나타났다. 그러므로 철망사이에 철선을 삽입한 것 중 성능이 우수한 것은 150-ø2. 0-150으로 나타났다. 5. 실험한 재생기 축열재들 중에서 성능이 우수한 것들을 비교한 결과, 복합 철선 ø1.2-1 50이 가장 성능이 좋은 것으로 나타났다.

  • PDF

Aggregate Utilization Estimation of River Sand according to Typical Location of Main Stream of Nakdong-River (낙동강 본류의 대표위치별 하천모래의 골재 활용성 평가)

  • Park, Jae-Im;Bae, Su-Ho;Kwon, Soon-Oh;Kim, Chang-Duk;Lee, Seung-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3719-3725
    • /
    • 2012
  • Due to the recent shortage of well-graded river sand resulting from a rapid growth of concrete construction, sea sand, crushed sand, and etc. are increasingly used instead. It is, however, well noted that non-washed sea sand leads to corrosion of the reinforcing steel in concrete, and thus eventually results in damage to concrete. Also, the crushed sand is not being widely used, since it is difficult to maintain the allowable amount of passing 0.08mm sieve and to adjust grading. On the other hand, because the fine sand of Nakdong-River has a poor grading but good quality as a fine aggregate for concrete, it is strongly needed to investigate the fine sand as an alternative fine aggregate. Thus, the purpose of this research is to evaluate the physical properties of the fine sand of Nakdong-River to utilize it actively as a fine aggregate. For this purpose, after the sand samples were collected according to typical location of main stream of Nakdong-River, the physical properties such as density in oven-dry condition, grading, unit volume mass, and etc. of them were estimated. It was observed from the test results that physical properties of the fine sand of Nakdong-River except grading were found to be excellent.