• Title/Summary/Keyword: steel model

Search Result 4,477, Processing Time 0.028 seconds

Wind load parameters and performance of an integral steel platform scaffold system

  • Zhenyu Yang;Qiang Xie;Yue Li;Chang He
    • Wind and Structures
    • /
    • v.36 no.4
    • /
    • pp.263-275
    • /
    • 2023
  • As a new kind of construction facility for high rise buildings, the integral steel platform scaffold system (ISPS) consisting of the steel skeleton and suspended scaffold faces high wind during the construction procedure. The lattice structure type and existence of core tubes both make it difficult to estimate the wind load and calculate the wind-induced responses. In this study, an aeroelastic model with a geometry scale ratio of 1:25 based on the ISPS for Shanghai Tower, with the representative square profile, is manufactured and then tested in a wind tunnel. The first mode of the prototype ISPS is a torsional one with a frequency of only 0.68 Hz, and the model survives under extreme wind speed up to 50 m/s. The static wind load and wind vibration factors are derived based on the test result and supplementary finite element analysis, offering a reference for the following ISPS design. The spacer at the bottom of the suspended scaffold is suggested to be long enough to touch the core tube in the initial status to prevent the collision. Besides, aerodynamic wind loads and cross-wind loads are suggested to be included in the structural design of the ISPS.

Seismic retrofit of structures using added steel column friction dampers

  • Mohammad Mahdi Javidan;Asad Naeem;Jinkoo Kim
    • Steel and Composite Structures
    • /
    • v.49 no.3
    • /
    • pp.257-270
    • /
    • 2023
  • In this study, the feasibility and applicability of a friction damper with a vertical installation scheme are investigated. This device is composed of a steel section and two friction hinges at both ends which dissipate seismic energy. Due to its small width and vertical installation scheme, the proposed damper can minimize the interference with architectural functions. To evaluate the performance of the proposed damper, its mechanical behavior is theoretically evaluated and the required formulas for the yield strength and elastic stiffness are derived. The theoretical formulas are verified by establishing the analytical model of the damper in the SAP2000 software and comparing their results. To further investigate the performance of the developed damper, the provided analytical model is applied to a 4-story reinforced concrete (RC) structure and its performance is evaluated before and after retrofit under the Maximum Considered Earthquake (MCE) hazard level. The seismic performance is thoroughly evaluated in terms of maximum interstory drift ratio, displacement time history, residual displacement, and energy dissipation. The results show that the proposed damper can be efficiently used to protect the structure against seismic loads.

Performance of plastic hinges in FRP-strengthened compressive steel tubes for different strain-hardening response

  • Ali Reza Nazari;Farid Taheri
    • Structural Engineering and Mechanics
    • /
    • v.91 no.3
    • /
    • pp.301-313
    • /
    • 2024
  • Plastic buckling of tubular columns has been attributed to rotational instability of plastic hinges. The present study aimed to characterize the plastic hinges for two different grades of strain-hardening, examined in mild-steel (MS) and stainless-teel (SS) tubes with un-strengthened and strengthened conditions. At the primary stage, the formerly tested experimental specimens were simulated using full-scale FE models considering nonlinear response of the materials, then to estimate the characteristics of the plastic hinges, a meso model was developed from the critical region of the tubes and the moment-rotation diagrams were depicted under pure bending conditions. By comparison of the relative rotation diagram obtained by the full-scale models with the critical rotation under pure bending, the length and critical rotation of the plastic hinges under eccentric axial load were estimated. The stress and displacement diagrams indicated the mechanism of higher energy absorption in the strengthened tubes, compared to unstrengthened specimens, due to establishment of stable wrinkles along the tubes. The meso model showed that by increasing the critical rotation in the strengthened MS tube equal to 1450%, the energy absorption of the tube has been enhanced to 2100%, prior to collapse.

Strain-rate Effect on Tensile Properties of High-nitrogen Austenitic Stainless Steel (고질소 오스테나이트계 스테인리스강의 인장물성에 미치는 변형속도의 영향)

  • S. H. Lee;D. W. Kim;Y. G. Kim;J.-H. Kang
    • Transactions of Materials Processing
    • /
    • v.33 no.5
    • /
    • pp.322-329
    • /
    • 2024
  • Because a high strain rate suppresses cross slip and delays dynamic recovery in the alloys with a face-centered cubic (FCC) structure, it is generally accepted that the influence of strain rate on strain hardening rate and tensile strength is greater than that on the yield strength of FCC alloys. The present study examined the tensile behavior of an austenitic stainless steel exhibiting an FCC structure, and revealed that the increment in yield strength was greater than that in tensile strength as the strain rate increased from 5.21×10-5s-1 to 4.17×10-1s-1. This indicated that the strain hardening rate was reduced by increasing the strain rate, which was inconsistent with the conventional explanation. Adiabatic heating was detected at high strain rates from 5.21×10-5s-1, and the resulting temperature increase could elevate stacking fault energy. The tendency for sip planarity was investigated by applying the Ludwigson model to the tensile curves, which suggested that higher stacking fault energy due to adiabatic heating could accelerate cross slip and dynamic recovery, thereby reducing the strain hardening rate.

The Seismic Response Evaluation of Ordinary Moment Resisting Steel Frames (철골 보통모멘트골조의 지진응답평가)

  • 이준석
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.233-238
    • /
    • 2000
  • The purpose of this study is to outline the analysis procedure for evaluating the performance of moment resisting steel frames. For this purpose, three ordinary moment resisting frames are designed in compliance to UBC 1994. The evaluation is performed by nonlinear static procedures using two analytical models. Only one analytical model using panel element can reflect the panel zone deformation explicitly. The limit values in FEMA 273 are used as guidelines of predicted demand parameters by which the performance of OMRFs may be assessed.

  • PDF

Geometrically nonlinear analysis of plane frames composed of flexibly connected members

  • Gorgun, H.
    • Structural Engineering and Mechanics
    • /
    • v.45 no.3
    • /
    • pp.277-309
    • /
    • 2013
  • Beam-to-column connections behaviour plays an important role in the analysis and design of steel and precast concrete structures. The paper presents a computer-based method for geometrically nonlinear frames with semi-rigid beam-to-column connections. The analytical procedure employs modified stability functions to model the effect of axial force on the stiffness of members. The member modified stiffness matrix, and the modified fixed end forces for various loads were found. The linear and nonlinear analyses were applied for two planar steel structures. The method is readily implemented on a computer using matrix structural analysis techniques and is applicable for the efficient nonlinear analysis of frameworks.

Wind induced response of an elevated steel water tank

  • Sepe, Vincenzo;Zingali, Antonino E.
    • Wind and Structures
    • /
    • v.4 no.5
    • /
    • pp.383-398
    • /
    • 2001
  • The paper describes the results of the monitoring of an elevated steel water-tank with unusual shape, 85 m high and 40 m wide. The research was carried out analysing both the static and dynamic behaviour under wind actions. The instruments used (some of which were employed for the first time for this project) are described and the data processing procedures are discussed. Comparison between the experimental results and those obtained through a numerical model gives interesting information both on the structural behaviour and on the characterisation of wind actions.

Probabilistic Reliability Assessment of Steel Frame with Leaning Columns

  • Vaclavel, Leo;Marek, Pavel
    • Computational Structural Engineering : An International Journal
    • /
    • v.1 no.2
    • /
    • pp.97-106
    • /
    • 2001
  • Safety and serviceability of a planar steel frame are assessed. Attention is turned to the individual main steps in the assessment procedure, i.e., to the definition of loads, selection of transformation model, determination of the response of the structure to the loading, and to the definition of the limiting values (considering safely and serviceability of the structure). The potential of the method using direct Monte Carlo technique as a powerful tool is emphasized.

  • PDF

A Study on the Optimum Structural Components of the Rural House Using the Light Gage Cold-Formed Steel Frame (경량형강을 이용한 농촌주택의 최적 구조요소 선정에 관한 연구)

  • 정남수;이정재
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.167-170
    • /
    • 1998
  • In this study, the optimum structural components of the rural house using the light gage cold-formed steel frame is proposed. The model for selecting the optimum structural components, determines the range of load by the region and size of house, calculates the weight of the component by structural design process and optimizes a kind of the component by sensitivity analysis of the component to the total weight.

  • PDF

Cracking Control of Concrete Deck in Steel-Concrete Composite Bridges (강합성 교량의 바닥판 콘크리트 균열관리)

  • 박해균;이명섭;안병제;곽효경;서영재
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.355-362
    • /
    • 2001
  • This study deals with cracking control of concrete deck in steel-concrete composite bridges according to the concrete slab casting sequences. In correlation studies between casting sequences, time dependent effects of concrete creep and shrinkage are implemented in the analytical model. Finally, the methods of cracking control in terms of concrete slump and relative humidity are suggested to prevent early transverse cracking of concrete slab.

  • PDF