• Title/Summary/Keyword: steady-state model

Search Result 1,529, Processing Time 0.036 seconds

On the Steady State Availability of Age-Dependent Minimal Repair Model

  • Cha, Ji-Hwan;Kim, Jae-Joo
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2002.06a
    • /
    • pp.17-22
    • /
    • 2002
  • Availability is an important characteristic of a repairable component. Iyer(1992) obtained the 'limiting efficiency'(not the `steady state availability') of the age-dependent minimal repair model which was first considered by Block et al.(1985). However the existence of the steady state availability of the model has not been reported. In this note, the existence of the steady state availability of the model is shown and a brief remark on the importance of the property is given.

  • PDF

Performance Analysis of a Stand-alone Brushless Doubly-fed Induction Generator Using a New T-type Steady-state Model

  • Liu, Yi;Xu, Wei;Zhi, Gang;Zhang, Junlin
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.1027-1036
    • /
    • 2017
  • The brushless doubly-fed induction generator (BDFIG) is a new type of dual stator winding induction generator. In such a generator, both the power winding (PW) and the control winding (CW) are housed in the stator. This paper presents the performance characteristics of a stand-alone BDFIG operation system. A new T-type steady-state model of a BDFIG is proposed. This model is more suitable for the performance analysis of stand-alone BDFIGs than the conventional Π-type steady-state model and the simplified inner core steady-state model. The characteristics of the power flow and CW current are analyzed by detailed mathematical derivations on the basis of the proposed T-type steady-state model. The analysis results are verified by experiments, which are carried out on a prototype BDFIG. The results of the performance analysis contribute to simplifying the control circuit, improving the control performance, and selecting an appropriate BDFIG for actual industrial applications.

Steady-State Solution for Solar Wind Electrons by Spontaneous Emissions

  • Kim, Sunjung;Yoon, Peter H.;Choe, G.S.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.44.2-44.2
    • /
    • 2016
  • The solar wind electrons are made of three or four distinct components, which are core Maxwellian background, isotropic halo, and super-halo (and sometimes, highly field-aligned strahl component which can be considered as a fourth element). We put forth a steady-state model for the solar wind electrons by considering both the steady-state particle and wave kinetic equations. Since the steady-state solar wind electron VDFs and the steady-state wave fluctuation spectrum are related to each other, we also investigate the complete fluctuation spectra in the whistler and Langmuir frequency ranges by considering halo- and superhalo-like model electron VDFs. It is found that the energetic electrons make important contributions to the total emission spectrum. Based on this, we complete the steady-state model by considering both the whistler and Langmuir fluctuations. In particular, the Langmuir fluctuation plays an important role in the formation and maintenance of nonthermal electrons.

  • PDF

Development of a Real-Time Steady State Detector of a Heat Pump System to Develop Fault Detection and Diagnosis System (열펌프의 고장진단시스템 구축을 위한 정상상태 진단기 개발)

  • Kim, Min-Sung;Yoon, Seok-Ho;Kim, Min-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2070-2075
    • /
    • 2008
  • Identification of steady-state is the first step in developing a fault detection and diagnosis (FDD) system. In a complete FDD system, the steady-state detector will be included as a module in a self-learning algorithm which enables the working system's reference model to "tune" itself to its particular installation. In this study, a steady-state detector of a residential air conditioner based on moving windows was designed. Seven representing measurements were selected as key features for steady-state detection. The optimized moving window size and the feature thresholds was suggested through startup transient test and no-fault steady-state test. Performance of the steady-state detector was verified during indoor load change test. From the research, the general methodology to design a moving window steady-state detector was provided for vapor compression applications.

  • PDF

BIFURCATION ANALYSIS OF A SINGLE SPECIES REACTION-DIFFUSION MODEL WITH NONLOCAL DELAY

  • Zhou, Jun
    • Journal of the Korean Mathematical Society
    • /
    • v.57 no.1
    • /
    • pp.249-281
    • /
    • 2020
  • A reaction-diffusion model with spatiotemporal delay modeling the dynamical behavior of a single species is investigated. The parameter regions for the local stability, global stability and instability of the unique positive constant steady state solution are derived. The conditions of the occurrence of Turing (diffusion-driven) instability are obtained. The existence of time-periodic solutions, the existence and nonexistence of nonconstant positive steady state solutions are proved by bifurcation method and energy method. Numerical simulations are presented to verify and illustrate the theoretical results.

Quasi-Steady-State Analysis on the Effect of the STATCOM on FRT Performance of Fixed Speed Wind Turbines (준정상상태 해석을 통한 고정속 풍력 발전기의 FRT에 대한 STATCOM의 효과 분석)

  • Ahn, Seon-Ju;Hwang, Pyeong-Ik;Nam, Soon-Ryul;Kang, Sang-Hee;Moon, Seung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.686-692
    • /
    • 2010
  • This paper analyzes the effect of the STATCOM on the improvement of the Fault Ride Through (FRT) capability of the fixed speed wind turbines(FSWTs). The steady-state models of the wind farm components, such as induction generator, capacitor bank, and the STATCOM, are developed based on the simplified equivalent circuit. Especially, the STATCOM is modeled as a controllable current source and a method that analytically determines the magnitude of the injection current is developed. For the quasi-steady-state(QSS) analysis, the steady-state model of the generator and STATCOM are merged with the dynamic model of drive train. The QSS simulation with the STATCOM shows that the STATCOM can enhance the FRT performance by improving the $W_r-T_e$ characteristics of the FSWTs.

Robust Kalman filtering for the TS Fuzzy State Estimation (TS 퍼지 상태 추정에 관한 강인 칼만 필터)

  • Noh, Sun-Young;Joo, Young-Hoon;Park, Jin-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1854-1855
    • /
    • 2006
  • In this paper, the Takagi-Sugeno (TS) fuzzy state estimation scheme, which is suggested for a steady state estimator using standard Kalman filter theory with uncertainties. In that case, the steady state with uncertain can be represented by the TS fuzzy model structure, which is further rearranged to give a set of uncertain linear model using standard Kalman filter theory. And then the unknown uncertainty is regarded as an additive process noise. To optimize fuzzy system, we utilize the genetic algorithm. The steady state solutions can be found for proposed linear model then the linear combination is used to derive a global model. The proposed state estimator is demonstrated on a truck-trailer.

  • PDF

Real-time steady state identification technology of a heat pump system to develop fault detection and diagnosis system (열펌프의 고장감지 및 진단시스템 구축을 위한 실시간 정상상태 진단기법 개발)

  • Kim, Min-Sung;Yoon, Seok-Ho;Kim, Min-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.282-287
    • /
    • 2008
  • Identification of steady-state is the first step in developing a fault detection and diagnosis (FDD) system. In a complete FDD system, the steady-state detector will be included as a module in a self-learning algorithm which enables the working system's reference model to "tune" itself to its particular installation. In this study, a steady-state detector of a residential air conditioner based on moving windows was designed. Seven representing measurements were selected as key features for steady-state detection. The optimized moving window size and the feature thresholds was suggested through startup transient test and no-fault steady-state test. Performance of the steady-state detector was verified during indoor load change test. From the research, the general methodology to design a moving window steady-state detector was provided for vapor compression applications.

  • PDF

Continuation-Based Quasi-Steady-State Analysis Incorporating Multiplicative Load Restoration Model (증배형 부하회복 모델을 포함하는 연속법 기반 준정적 해석)

  • Song, Hwa-Chang;Ajjarapu, Venkatanamana
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.2
    • /
    • pp.111-117
    • /
    • 2008
  • This paper presents a new continuation-based quasi-steady-state(CQSS) time-domain simulation algorithm incorporating a multiplicative aggregated load model for power systems. The authors' previous paper introduced a CQSS algorithm, which has the robust convergent characteristic near the singularity point due to the application of a continuation method. The previous CQSS algorithm implemented the load restoration in power systems using the exponent-based load recovery model that is derived from the additive dynamic load model. However, the reformulated exponent-based model causes the inappropriate variation of short-term load characteristics when switching actions occur, during time-domain simulation. This paper depicts how to incorporate a multiplicative load restoration model, which does not have the problem of deforming short-term load characteristics, into the time simulation algorithm, and shows an illustrative example with a 39-bus test system.

Technology for Real-Time Identification of Steady State of Heat-Pump System to Develop Fault Detection and Diagnosis System (열펌프의 고장감지 및 진단시스템 구축을 위한 실시간 정상상태 진단기법 개발)

  • Kim, Min-Sung;Yoon, Seok-Ho;Kim, Min-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.4
    • /
    • pp.333-339
    • /
    • 2010
  • Identification of a steady state is the first step in developing a fault detection and diagnosis (FDD) system of a heat pump. In a complete FDD system, the steady-state detector will be included as a module in a self-learning algorithm, which enables the working system's reference model to "tune" itself to its particular installation. In this study, a steady-state detector of a residential air conditioner based on moving windows was designed. Seven representative measurements were selected as key features for steady-state detection. The optimized moving-window size and the feature thresholds were decided on the basis of a startup-transient test and no-fault steady-state test. Performance of the steady-state detector was verified during an indoor load-change test. In this study, a general methodology for designing a moving-window steady-state detector for applications involving vapor compression has been established.