• 제목/요약/키워드: steady-state current

검색결과 815건 처리시간 0.026초

N상 Interleaved Boost 컨버터의 정상상태 특성 해석 (Steady-State Analysis of N-phase Interleaved Boost Converter)

  • 박종규;장성동;신휘범;김흥근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권3호
    • /
    • pp.196-205
    • /
    • 2004
  • Although many papers about the interleaved boost converter(IBC) have been published, there are, unfortunately, no analytical and rigorous expressions for steady-state operation of the N-phase IBC. To understand the operating characteristics of the N-phase IBC, the averaged state equation and the general steady-state solutions are derived in this paper. The general expressions of the current unbalance due to the parameter mismatch, the inductor and input current ripples, and the output voltage ripple are also presented. Through the analytical expressions presented, the steady-state characteristics of the N-phase IBC are analyzed theoretically and verified experimentally.

단상 영구자석형 유도동기기의 정상상태 특성해석 (Steady-State Characteristic Analysis of Single-Phase Line-Start Permanent Magnet Synchronous Motor)

  • 강규홍;남혁;홍정표
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권2호
    • /
    • pp.53-60
    • /
    • 2003
  • This paper deals with steady-state analysis of a single-phase line-start permanent magnet synchronous motor. In order to analyze the steady-state characteristics, the asymmetric single-phase line-start synchronous motor is converted to the symmetric two-phase synchronous motor, that is, the asymmetric magnetic field is separated from the positive and the negative symmetric components using symmetrical-component theory. The analysis method of the synchronous motor on the d-q axis coordinates is used for the positive component and the equivalent circuit of the induction motor is applied for the negative component analysis. Moreover, d-q axis inductance considering current phase angle is applied to positive component analysis for precise characteristic analysis. In order to validate the proposed analysis method, the analysis results are compared with the experimental results.

3상 일괄형 Pipe Type HTS 케이블의 정상 및 과도상태 해석 (Steady and Transient State Analysis on Three Phase-in One Enclosure Type HTS Cable)

  • 장주영;이종범;김용갑
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1748-1753
    • /
    • 2010
  • This paper suggests an improved technique to establish the modeling regarding steady and transient state on three phase-in one cryostat type HTS(High Temperature Superconducting) cable. The proposed modeling is established using EMTP/ATPDraw and TACS and MODELS provided by that. It has higher accuracy than the conventional method, as the actual HTS cable is modelled. Steady and transient state analysis performed by EMTP/ATPDraw calculate the current of conductor, shield and former, respectively. In case of the transient state modeled quench state occurred by a single line-to-ground fault, current of conductor shield and former are also calculated, respectively. Especially, various fault resistances and angles are considered to improve the reliability during transient state analysis. Analysis results reveal that the proposed technique improves the accuracy of modeling.

전류 센서를 이용한 디지탈 논리회로의 고장 검출 (On the detection of faults on digital logic circuits using current sensor)

  • 신재흥;임인칠
    • 전자공학회논문지A
    • /
    • 제33A권2호
    • /
    • pp.173-183
    • /
    • 1996
  • In this paper, a new structure that can do fault detection and location of digial logic circuits more efficiently using current testing techniques is proposed. In the conventional method, observation point for steady state power supply current was only one, but in the proposed method more fault classes are divided for fault detection and location through the ovservation of steady state power supply current at two points. Also, it is shown that this structure can be easily applied in detection of stuck-open fault which is not easy to do testing with conventional current testing techniques. In the presented mehtod, an extra trasnistor is used, and current path is made compulsorily in the CMOS circuits in which no current path can be established in steady state, then it can be known that stuck-open tault is in the MOS transistor on the considering current path, if this path disappears due to stuck-open fault. The validity and the effectiveness is shwon, thorugh the SPICE simulation of circuits with fault and the current path search experiment using current path search program based on transistor short model wirtten in C language on SUN sparc workstation.

  • PDF

직렬공진 특성을 이용한 DC-DC 컨버터의 정상상태 특성해석 (The Steady State Analysis of the DC-DC Converter used Series Resonant Characteristics)

  • 이윤종;김능수;김철진;홍금표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.530-533
    • /
    • 1987
  • In high-frequency switched mode converters, Series Resonant Converter (SRC) is investigated using state-plane method. Phase plane trajectories of the SRC permit a direct closed form solution of the steady state operation and can make problems easy to solve. This paper describes steady state responses and characteristics of the SRC with respect to various circuit factors. The magnitute of steady state response and the average current through load are clearly related to how such the switching frequency differs from the resonant frequency. The results of the steady state analysis can be used to estimate the device and component stress on the power circuit.

  • PDF

CURRENT CONTROL FOR PWM AC-DC CONVERTER USING SINUSOIDAL TRACKING CONTROLLER

  • Woo, Jung-In;Heo, Tae-Won;Lee, Hyun-Woo;Kim, Choon-Sam;Jung, Yung-Il
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.928-933
    • /
    • 1998
  • This paper presents a novel current control system to eliminate the steady state control error and to improve the transient characteristics for PWM AC-DC converter. A general mathematical model of the converter that is represented as a state-space model is first established. The state-space model is used for the simulation of PWM switching converter with the proposed current control system. The proposed sinusoidal tracking control system that does not require coordinate transformations using principle of the integral controller is described. It is proved that the steady state deviation reduces to zero through a transfer function of source current control system. Finally, it is seen that simulations agree with the experimental results in source current and reference of controlled ac current loop.

  • PDF

PI 제어기의 내부원리를 이용한 PWM AC-DC 컨버터의 새로운 전류제어 (Novel current control for PWM AC-DC converter using internal principle of PI controller)

  • 허태원;황영민;김영빈;이현우;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.1944-1946
    • /
    • 1998
  • This paper presents a novel current control system to eliminate the steady state control error for PWM AC-DC converter. A general mathematical model of the converter which is represented as a state-space model is established. The state-space model is used for the simulation of converter with the proposed tracking control system of sinusoidal current. In this system, a novel current control which do not require coordinate transformations using internal principle of PI controller is described. It is proved that the steady state deviation reduce to zero through a transfer function of source current control system. Finally, simulations show good source current control characteristics by means of a simplified control system which do not require coordinate transformations.

  • PDF

전향보상 전압의 위상 변화를 통한 단독운전 검출 방법의 계통 정상 상태의 성능 평가 (Performance Evaluation of Islanding Detection Method by Phase Shifted Feed-Forward Voltage in Steady-State Grid Condition)

  • 김동욱;김성민
    • 전력전자학회논문지
    • /
    • 제23권6호
    • /
    • pp.373-380
    • /
    • 2018
  • This study proposes a new islanding detection method that uses the phase shift of feed-forward voltage and evaluates the performance of an existing method and the proposed method when the grid frequency changes within the allowable range under steady-state conditions. The investigated existing method, which is slip mode frequency shift (SMS), uses current phase shift to detect islanding. The SMS method supplies reactive current to the grid under this condition, but the proposed method does not generate additional reactive power because it does not depend on the current control loop. The performance in steady-state grid condition is evaluated through simulations and experiments.

직접 토크제어에 의한 유도전동기 토크맥동 저감 시스템 (A Torque Ripple Reduction System of Induction Motor with Direct Torque Control)

  • 김남훈;김민호;김민회;김동희;황돈하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.276-279
    • /
    • 2001
  • Direct torque control(DTC) is known to produce quick response in ac drives. Some drawbacks of the classical DTC are the relatively large torque ripple in a low speed range and notable current pulsation during steady state. They are reflected speed response and increased acoustical noise. In this paper, The DTC quick response are preserved at transient state, while better qualify steady state performance is produced by Space Vector Modulation(SVM). It is able to reduce the acoustical noise, torque ripple and current pulsation during steady state. The system presented are closed loop stator flux and torque observer for wide speed range that inputs are currents and voltages sensing of motor terminal. Simulation results for the 2.2kw general purposed induction motor are presented and discussed.

  • PDF

Performance Analysis of a Stand-alone Brushless Doubly-fed Induction Generator Using a New T-type Steady-state Model

  • Liu, Yi;Xu, Wei;Zhi, Gang;Zhang, Junlin
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.1027-1036
    • /
    • 2017
  • The brushless doubly-fed induction generator (BDFIG) is a new type of dual stator winding induction generator. In such a generator, both the power winding (PW) and the control winding (CW) are housed in the stator. This paper presents the performance characteristics of a stand-alone BDFIG operation system. A new T-type steady-state model of a BDFIG is proposed. This model is more suitable for the performance analysis of stand-alone BDFIGs than the conventional Π-type steady-state model and the simplified inner core steady-state model. The characteristics of the power flow and CW current are analyzed by detailed mathematical derivations on the basis of the proposed T-type steady-state model. The analysis results are verified by experiments, which are carried out on a prototype BDFIG. The results of the performance analysis contribute to simplifying the control circuit, improving the control performance, and selecting an appropriate BDFIG for actual industrial applications.