Improved RRS Logical Architecture using Genetic Algorithm (유전자 알고리즘 적용을 통한 향상된 RRS Logic 개발)

  • Shim, Hyo Sub;Jung, Jae Chun
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.12 no.2
    • /
    • pp.115-125
    • /
    • 2016
  • An improved RRS (Reactor Regulating System) logic is implemented in this work using systems engineering approach along with GA (Genetic Algorithm) deemed as providing an optimal solution to a given system. The current system works desirably and has been contributed to the safe and stable NPP operation. However, during the ascent and decent section of the reactor power, the RRS output reveals a relatively high steady state error and the output also carries a considerable level of overshoot. In an attempt to consolidate conservatism and minimize the error, this research proposes applying genetic algorithm to RRS and suggests reconfiguring the system. Prior to the use of GA, reverse-engineering is implemented to build a Simulink-based RRS model and re-engineering is followed to apply the GA and to produce a newly-configured RRS generating an output that has a reduced steady state error and diminished overshoot level.

Design and Analysis of Large Capacity Lithium Polymer Battery Charger for Hybrid Electrical Vehicle (HEV용 중대형 2차전지 충전기 설계 및 해석)

  • Oh Dong-Seob;Oh Sung-up;Seong Se-jin;Choi Jae-dong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.87-91
    • /
    • 2004
  • In this paper, the paralleled forward converter, that is generally used as the power supply for the low voltage, high current load, is described. The proposed forward converter for battery charging could be provided the power without failure not only in steady state but also in the transient period by the step load variation or the unexpected faults among the converter modules. Each converter nodule designed is operated alone with the self closed controller for the elevation of stability, performance, reliability, and maintainability. The frequency response of the designed converter module is analyzed, and the stability is confirmed in analytic method. And the experiments of the paralleled battery charger are carried out in steady state, in the step load variation.

  • PDF

The Analysis and Simulation of Current Source Inverter-Induction Motor System Using Switching Function Representation (스위칭함수에 의한 전류형 인버어터 유도전동기 시스템의 해석 및 시뮬레이션)

  • 박민호;전태원;정승기
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.5
    • /
    • pp.185-192
    • /
    • 1986
  • This paper deals with the general mathmatical model of the CSI-fed induction motor system. The inverter is represented by a switching function matrix which is combined with the dg model of an induction motor. Complete system model is given by a set of differential equations in a closed form, which inherently includes the harmonic effects of the converter and the inverter. The model is valid in evaluating both the transient and steady state responses, while the more simple analytical model can be derived from the general model, in a steady state. With the model proposed, the digital simulation is carried out on a 10KVA CSI-induction motor system and the simulation results show good agreements with experimental ones.

  • PDF

Intelligent Parameter Estimation of a Induction Motor Using Immune Algorithm

  • Kim, Dong-Hwa;Cho, Jae-Hoon
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2004.10a
    • /
    • pp.21-25
    • /
    • 2004
  • This paper suggests the techniques in determining the values of the steady-state equivalent circuit parameters of a three-phase squirrel-cage induction machine using immune algorithm. The parameter estimation procedure is based on the steady state phase current versus slip and input power versus slip characteristics. The proposed estimation algorithm is of a nonlinear kind based on clonal selection in immune algorithm. The machine parameters are obtained as the solution of a minimization of least-squares cost function by immune algorithm. Simulation shows better results than the conventional approaches.

  • PDF

Analysis and Implementation of ANFIS-based Rotor Position Controller for BLDC Motors

  • Navaneethakkannan, C.;Sudha, M.
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.564-571
    • /
    • 2016
  • This study proposes an adaptive neuro-fuzzy inference system (ANFIS)-based rotor position controller for brushless direct current (BLDC) motors to improve the control performance of the drive under transient and steady-state conditions. The dynamic response of a BLDC motor to the proposed ANFIS controller is considered as standard reference input. The effectiveness of the proposed controller is compared with that of the proportional integral derivative (PID) controller and fuzzy PID controller. The proposed controller solves the problem of nonlinearities and uncertainties caused by the reference input changes of BLDC motors and guarantees a fast and accurate dynamic response with an outstanding steady-state performance. Furthermore, the ANFIS controller provides low torque ripples and high starting torque. The detailed study includes a MATLAB-based simulation and an experimental prototype to illustrate the feasibility of the proposed topology.

Sensorless Vector Control of Induction Motor using Speed Observer in Steady State (정상상태에서 속도관측기를 이용한 유도전동기 센서리스 벡터제어)

  • 이수원;전칠환;이성룡
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.6
    • /
    • pp.1142-1146
    • /
    • 2004
  • This paper describes sensorless vector control of induction motor using speed observer in steady state. In sensorless vector control of induction motor, the proposed speed observer is consists of q-axis voltage of controller and real current. This paper investigates the speed characteristics when a step change of speed reference. This is verified by simulations and experimental results.

The Study of Steady-State Interaction Between AC and DC Lines on the Same Transmission Tower (AC 및 DC 송전 선로 병렬 연계에 따른 정상상태 커플링 영향 분석)

  • Yoon, Jong-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.7
    • /
    • pp.1221-1225
    • /
    • 2010
  • The application of the AC and DC lines on the same transmission tower is an economical and practical approaching that increase the power transmission capacity of an existing transmission corridor. But, In this case, Inductive and capacitive coupling between AC and DC lines on the same tower should be investigated in advance. According to the installation plan of 80kV ${\pm}$60MW bipole HVDC in Cheju, KOREA that will be commissioned until 2011, DC lines will parallely operate with 154kV 2 AC lines in existed 154kV AC 4 lines transmission tower. This paper presents the steady state analysis results about the interaction between 154kV AC and 80kV DC lines in the same transmission tower.

The Electronic Ballast of HID (High Intensity Discharge) Lamp using internal resonance (내부 공진을 이용해 점등하는 메탈할라이드 고압방전등 전자식 안정기)

  • Cho B. C.;Moon S. J.;Lee I. K.;Cho B. H.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.580-583
    • /
    • 2001
  • A high ignition voltage is required for the metal halide (MHD) lamp. In this paper, the ballast ignited by internal LC resonance of buck converter with minimum size is proposed. For minimizing the ignition current for device safety, the characteristic impedance is maximized. But this results In a large steady state ripple, which may cause the accoustic resonance. The steady state ripple cancellation network using the coupled inductor is proposed.

  • PDF

High Voltage Power Supply using an LLC Resonant Half bridge Converter (LLC 공진형 하프브릿지 컨버터를 이용한 고전압 전원장치)

  • Gil, Young-Man;Ga, Dong-Hoon;Ahn, Tae-Young;Choi, Eun-Sil;Lee, Jun-Hak;Lee, Hak-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.522-523
    • /
    • 2012
  • In this paper, we present an experimental results of 15kV class high-volatge power supply using the LLC resonant half-bridge converter for CNT lamp. The resonant current of the LLC resonant half-bridge converter prototype in the steady state was stable. The output voltage of prototype converter was maintained at about 15kV in the steady state.

  • PDF

Internal Perfusion of ADP in Mouse Oocytes Increases Outward $K^+$ Currents (ADP에 의한 생쥐 난자의 외향전류 증가 효과)

  • 한재희;박홍기;강다원;이상미;이상호;배인하;홍성근
    • Development and Reproduction
    • /
    • v.4 no.2
    • /
    • pp.243-250
    • /
    • 2000
  • To find the mechanism underlying the ADP-induced increase in the outward current in ovulated mouse oocytes, we examined changes in voltage-dependent currents using the whole cell voltage clamp technique and the internal perfusion technique. Eggs were collected from the oviduct of superovulated mice with PMSG and hCG. Membrane potential was held at -60 mV (or -80 mV in the case of recording $Ca^{2+}$ currents) and step depolarizations or hyperpolarizations were applied for 300 ms. By step depolarizations, outward currents comprising steady-state and time-dependent components were elicited. They were generated in response to the positive potential more than 20 mV with severe outward rectification and were blocked by external TEA, a specific $K^{+}$ channel blocker, suggesting that they be carried via $K^{+}$ channels. Internally-perused 5 mM ADP gradually increased outward $K^{+}$ currents (IK) 1 min after perfusion of ADP and reached slowly to maximum (150~170%) 5 min later over the positive potential range, implying that ADP might not be acted directly to the $K^{+}$ channels. IK were decreased by 5 mM ATP without affecting the steady-state component of outward current. In contrast to the effect of ADP and ATP on IK, both effect of ATP and ADP on inward $Ca^{2+}$ currents (ICa) could not be detected due to the continuous decrease in current amplitudes with time-lapse ("run-down" phenomena). To check if there is a G protein-involved regulation in the ionic current of mouse oocytes, 1 mM GTP was applied to the cytoplasmic side, and the outward current and inward currents were recorded. ICa was promptly increased in the presence of GTP whereas IK was not changed. from these results, it is concluded that the ATP-dependent regulation is likely linked in the ADP-induced increase in the outward $K^{+}$ current, and G protein-involved cellular signalling might affect ion channels carrying $Ca^{2+}$ and $K^{+}$ in mouse oocytes.