• 제목/요약/키워드: steady state distribution

검색결과 489건 처리시간 0.028초

적외선 영상 처리를 통한 Formalin Test 통증 모델에서의 염전 침자극 효과에 대한 연구 (A Study of Analgesic Effect of Twirling Acupuncture on Pain Model of the Formalin Test Using the Infrared Thermal Image Processing)

  • 류재관;이순걸;임성수;이재동;민병일;류운영
    • Journal of Acupuncture Research
    • /
    • 제21권2호
    • /
    • pp.223-233
    • /
    • 2004
  • Objective: As a manual accupucture method, the twirling-needle treatment has been known more effective in relieving pain than the conventional simple accupuncture treatment. Finding a proper treatment condition is difficult because of the lack of a quantative measurement of the alleviation of pain made by acupuncture. In this research, the authors propose the use of infrared thermal images in a formalin test to quantatively verify the effect of twirling. Methods: After injecting 10%~20% formalin into the tail of rats, the infrared thermal images(ITI) have been obtained to estimate the thermal distribution caused by inflammation. The authors propose a processing method to measure the thermal distribution from the thermal images obtained from the infrared camera as a pain model of the formalin test. Results: The pain model obtained from the infrared thermal image has two phases. The first phase, which is a transient period, is the initial 20 minutes when the pain is developed after the formalin injection. The second phase, which is a steady state, is where the development of pain lasts for 60 minutes or more after the first stage. This characteristic of the proposed model based on ITI is consistent with that of the pain model reported by other researchers whose works are based on the time-course of flinching and licking/biting, following a different concentration of formalin. It is noticed that the response of the thermal distribution obtained from ITI shows very high correlation to the behavioral response in the formalin test performed by Kazuhiro Okuda and four others5). In addition, the authors propose an ITI method to determine the pain-reducing effect of the acupuncture. The thermal distribution obtained from the experiment shows that there is significant pain reducing effect made by the twirling-needle method.

  • PDF

신규 플루오로퀴놀론계 DWP20367의 흰쥐 및 개에서의 체내동태와 조직분포 (Pharmacokinetics and Tissue Distribution of DWP20367, a Novel Fluoroquinoloce, in Rats and Beagle Dogs)

  • 조재열;한승희;김병오;남권호;손호정;유영효;정대영
    • Biomolecules & Therapeutics
    • /
    • 제5권3호
    • /
    • pp.284-291
    • /
    • 1997
  • The pharmacokinetics and tissue distribution of DWP20367 (1-cyclopropyl-6-fluoro-8-chloro-7-(2, 7-diazabicyclo[3,3,0]tract-4-ene-7-yl)-1,4-dihydro-4-oxoquinoline-3-carboxylic acid), a novel fluoroquinolone, were examined in rats and beagle dogs after a single intravenous and oral administration. Analysis of DWP20367 in plasma, tissue, and urine was determined by both HPLC and microbiological assay (bioassay). The plasma concentration-time curves of the drug in rats and beagle dogs were biexponentially declined. The terminal half-life (t$_{1}$2$\beta$/) of the drug in rats was about 60.1 $\pm$7.3 min (i.v.) and 61.3 $\pm$ 12.4 min (p.o.) in bioassay, and 86.3 $\pm$19.8 min (i.v.) and 50.9$\pm$ 14.9 min (p.o.) in HPLC. In beagle dogs, half-life of the drug determined by bioassay was about 121.8$\pm$6.2 min (i.v.) and 111.0$\pm$7.6 min (p.o.). The volume of distribution at steady-state (Vd$_{ss}$ ) was 243.8$\pm$74.1 ml/kg (bioassay) and 339.2$\pm$84.3 ml/kg (HPLC) in rats, and 1587.5 $\pm$536.9 ml/kg (bioassay) in beagle dogs. The total body clearance (Cl$_{t}$) of DWP20367 was 3.4 $\pm$ 0.4 ml/min/kg (bioassay) and 2.4$\pm$0.4 ml/min/kg (HPLC) in rats, and 12.3$\pm$ 1.0 ml/min/kg (bioassay) in beagle dogs, respectively. The extent of bioavailability after oral administration was 89.1%(bioassay) and 79.9% (HPLC) in rats, and 78.7% (bioassay) in beagle dogs. Urinary recovery (24-h) assayed by bioassay was 0.7% (p.o.) and 1.2% (i.v.) in rats, and 0.8% (p.o.) and 1.0% (i.v.) in beagle dogs. In rats, 24-h fecal recovery determined by bioassay was 11.2% (p.o.) and 0.1% (i.v.). Rat and human serum protein binding ratios at 2$\mu$g/ml were about 90~91%. This drug determined by bioassay was also distributed by the order of liver, kidney, lung, heart, spleen and muscle 30 min after oral administration.on.

  • PDF

다양한 화재조건에서 플라스틱 종류에 따른 연기입자의 크기분포 변화 측정 (Measurement of the Size Distribution of Smoke Particles with Plastic Types Under Various Fire Conditions)

  • 구재학;황철홍
    • 한국화재소방학회논문지
    • /
    • 제31권6호
    • /
    • pp.8-15
    • /
    • 2017
  • 화재발생 시에 대부분의 인명 피해는 연기에 의해 발생되는데, 최근 건축 내장재에서 차지하는 플라스틱의 양이 많아지며 발생되는 연기의 유독성이 점차적으로 증가되고 있다. 연기에 의한 인체피해의 상당부분은 흡입연기의 폐침전과 관련이 있으며, 연기입자의 크기분포는 폐침전 특성에 직접적인 영향을 미친다. 따라서 플라스틱 종류에 따른 연기입자의 크기별 발생량 검토는 폐침전에 의한 인체피해 연구에 필수적으로 요구된다. 최근의 목재와 폴리프로필렌(PP)에 대한 연기입자의 발생특성 연구에서 PP의 연기입자 크기분포 특성이 몇 가지 측면에서 목재와는 확연히 다르게 나타났다. 이에 따라, 본 연구에서는 다른 플라스틱들도 연기입자 크기분포에서 PP와 같은 특성을 보이는지 알아보기 위해서 대표적인 4가지 플라스틱(LDPE, PA66, PMMA, PVC)에 대하여 연기입자 크기분포 측정실험을 수행하였다. 특정 조건에서 연소생성물을 균일하게 생성하고 분석하기 위하여 ISO/TS 19700 기준에 따른 등속튜브연소로를 이용하여 연소로의 온도와 산소공급량에 따라 다양한 화재조건에서 연기입자를 균일하게 발생시키고, 정전저압 임팩터를 사용하여 연기입자의 크기에 따른 개수농도를 실시간으로 측정하였다. 실험 결과 4가지 플라스틱의 연기입자 크기분포 특성은 여러 측면에서 PP와 유사하며 목재와는 확연히 다르게 나타났다.

통계적 확산이론에 기초한 다공질체의 유동관망 유동해석 기법 개발 (Development of a Pipe Network Fluid-Flow Modelling Technique for Porous Media based on Statistical Percolation Theory)

  • 신휴성
    • 지질공학
    • /
    • 제23권4호
    • /
    • pp.447-455
    • /
    • 2013
  • 본 연구에서는 다공질 지반체내의 투수계수를 계산하기 위하여 정방형의 배열형태를 갖는 유동관망(pipe network) 유동해석 모델을 개발하였다. 본 유동관망을 통한 유체의 흐름 메커니즘은 통계적 침투이론(percolation theory)에 기초하여 정의된다(Stauffer and Aharony, 1994). 여기서, 개별 유동관의 직경들이 주어진 다공질 매질의 공극률과 공극크기 분포특성을 기초로 하여 통계적으로 지정됨으로 계산된 유체흐름은 불균일한 채널 유동 형태로 나타난다. 본 유동해석에서는 유동관망 모델의 한쪽 경계면에 가압된 유체가 투입되고 다른 측면 경계면들은 흐름을 억제하는 경계조건을 두어 한 방향으로 유동관망을 통해 유체의 흐름을 유도하여 모델링된다. 이때, 흐름을 허용할지를 정의하는 확산조건(percolation condition)이 각 유동관에 부여되며, 이는 각 유동 경로의 직경과 재료면 특성을 기초로 계산된 삼투압(capillary pressure) 수준에 의해 정의된다. 유체가 유입되는 면의 수압에 대해 전체 유동관망 모델 내의 수압 분포가 평형을 이루면 유출되는 면의 수압이 일정해 지며, 유입면의 수압과 계산된 유출면의 수압 및 유동량을 Darcy 방정식에 적용하면 유동관망 모델로 모사된 다공질 매질의 투수계수를 얻어 낼 수 있다. 본 연구에서는, 민감할 것으로 예상된 유동 격자망의 규모의 투수계수 결과값에 대한 민감도를 검토하였으며, 실제 석유개발 현장에서 수집된 시추코어에 대해 측정된 투수계수값과 제안 네트워크 모델을 이용한 계산값과 비교하여 합리적인 범위 내에서 잘 부합됨을 보였다.

실험견에서 Metoprolol 약리효과의 약동/력학적 검토 (Pharmacokinetic/Pharmacodynamic Analysis of Metoprolol in Dogs)

  • 오동진;장인진;이경훈;임동석;김형기;신상구;박찬웅;신재국
    • 대한약리학회지
    • /
    • 제31권2호
    • /
    • pp.251-259
    • /
    • 1995
  • Pharmacokinetics and pharmacodynamics of metoprolol, a selective beta-l blocker, were examined for 360 minutes after intravenous bolus administration of metoprolol to 6 dogs. Plasma concentration and excreted amount in the urine metoprolol were measured by liquid chromatography with fluorescence detection. PR interval and heart rate were measured by ECG monitoring. Blood pressure was monitored through intraarterial catheter in femoral artery and cardiac output by thermodilution method using Swan-Ganz catheter. To analyze the effect site concentration-response relationship, plasma concentration and pharmacological effects were simultaneously fitted to a two pharmacokinetic compartment linked to pharmacodynamic model with NONLIN program. Results are as follows. 1) The plasma concentration of metoprolol after intrvenous injection decreased biexponentially. The terminal half-life estimated was $1.33{\pm}0.40$ hours and the volume of distribution at steady state (Vdss) and the total body clearance were $1.04{\pm}0.4\;L/kg,\;6.55{\pm}2.21\;L/hr$, respectively. The central compartment volume of distribution and peripheral compartment volume of distribution were $0.35{\pm}0.14L/kg\;and\;0.69{\pm}0.34L/kg$. The renal clearance and intercompartment clearance were $0.53{\pm}0.25\;L/min\;and\;0.35{\pm}0.19\;L/min$. 2) Simulated biophase concentration-response curve shows hyperbolic relationship and the estimated concentration-effect relationship was best explained by Emax model when the prolongation of PR interval and the reduction of the heart rate were used as pharmacodynamic parameters. Emax and EC50 were estimated to be $26.3{\pm}4.7\;msec\;and\;88.8{\pm}82.3\;g/ml$ for PR interval, and $48.7{\pm}18.8\;beats/min\;and\;113.5{\pm}78.7\;ng/ml$ for heart rate, respectively. 3) The changes of cardiac output-effect site concentration relationship was best fitted by a linear model and the slope of the relationship was $0.005{\pm}0.003$. Diastolic blood pressure-effect site concentration relationship was also explained by the linear model and the slope of the relationship was $0.038{\pm}0.034$.

  • PDF

돼지호흡기세균에 대한 oxytetracycline과 tiamulin의 시험관내 상승작용 및 돼지에서의 약물동태학 (Synergistic effects of oxytetracycline and tiamulin against swine respiratory bacteria and their pharmacokinetics in the pigs)

  • 박승춘;윤효인;이근우
    • 대한수의학회지
    • /
    • 제42권1호
    • /
    • pp.45-54
    • /
    • 2002
  • The study was carried out to characterize the pharmacokinetics after intravenous (iv, 20 mg/kg) and oral (p.o. 100 mg/kg) administration as oxytetracycline (OTC) and tiamulin (TIA) mixture in swine and to determine interaction between OTC and TIA against various pig pathogenic bacteria. The antibacterial effects of OTC in combination with TIA in vitro showed synergistic effect against Salmonella typhimurium 1925, Pasteurella multocida Type A, P. multocida Type D, Krebsiella Pneumoniae 2001, K. Pneumoniae 1560, K. Pneumoniae 2208, Haemophillus pleuropneumonia S 2, and H. pleuropneumonia S 5, but against additive effect E. coli K88ab and S. choleraesuis on the basis of fractional inhibitory concentration (FIC) index. On the while, after i.v. and p.o. administration of OTC and TIA mixture, each OTC and TIA concentrations in plasma were fitted to an open two-compartment model. After i.v. administration of OTC-TIA mixture, the mean distribution half-life ($T_{1/2{\alpha}}$) of OTC and TIA in plasma showed 0.29 h and 0.17 h, and the mean elimination half-life ($T_{1/2{\beta}}$) of those was 4.36 h and 6.64 h, respectively. The mean volume of distribution at steady state ($Vd_{ss}$) of OTC and TIA was $0.85{\ell}/kg$ and $2.44{\ell}/kg$, respectively. After oral administration of OTC and TIA mixture, the mean maximal absorption concentrations ($C_{max}$) of OTC and TIA were $0.60{\mu}g/m{\ell}$ at 1.07 h ($T_{max}$) and $1.68{\mu}g/m{\ell}$ at 1.85 h ($T_{max}$), respectively. The mean elimination half-life ($T_{1/2{\beta}}$) of those showed 6.84 h and 6.36 h. In conclusion, we could suggest in this study that the combination of OTC and TIA may be recommended for the antibacterial therapy against polymicrobial infections, and both OTC and TIA showed large distribution to tissues and high $C_{max}$ after p.o. administration.

수위가 변동하는 휠댐의 안정성 해석(I) (Seepage Analysis of Rock -fill Dam Subjected to Water Level Fluctuation)

  • 이대수
    • 한국지반공학회지:지반
    • /
    • 제12권6호
    • /
    • pp.65-78
    • /
    • 1996
  • 한반도 중부지역에 위치한 청평양수발전소의 상부저수지는 준공후 16년이 경과한 사력댐으로 매일 수위 상승 및 저하를 경험하므로써, 제체의 거동이 일반 댐과는 달리 여러 가지 지반공학적 관심을 불러 일으키고 있다. 침투류에 대한 안정성을 판단하기 위하여 종래에는 심벽만을 대상으로 하여 저수지의 수위변동을 고수위 및 저수위의 두 경우로 고정시킨 정상상태의 해석을 주로 사용함에 따라 임의의 시간에서의 전체적인 침투현상 규명이 어려웠으나, 본 연구에서는 수위변동을 경계조건에 반영한 2차원 비정상류 유한요소해석을 댐 전체단면을 대상으로 수행하여 정상상태의 해석과 비교하였으며, 수위 변동에 따라 해당시간에서의 동수 경사, 침투력 벡타, 간극수압 등을 정량적으로 규명하였고, 산정된 침투수량을 계측치와 비필하였다. 그 결과 본 댐은 파이핑, 내부 침식 또는 제체 내부로의 투수 등에 대하여 안전하다고 판단된다.

  • PDF

오차확률분포 사이 유클리드 거리의 새로운 기울기 추정법 (A New Gradient Estimation of Euclidean Distance between Error Distributions)

  • 김남용
    • 전자공학회논문지
    • /
    • 제51권8호
    • /
    • pp.126-135
    • /
    • 2014
  • 오차 신호의 확률분포 사이의 유클리드 거리 (Euclidean distance between error probability density functions, EDEP)는 충격성 잡음 환경의 적응 신호 처리를 위한 성능 지수로 사용되었다. 이 EDEP 알고리듬의 단점 중의 하나로 각 반복 시간마다 수행하는 이중적분에 의해 과다한 계산상의 복잡성이 있다. 이 논문에서는 EDEP 와 그 기울기 계산에서 계산상의 부담을 줄일 수 있는 반복적 추정 방법을 제안하였다. 데이터 블록 크기 N에 대하여, 기존의 추정 방식에 의한 EDEP와 그 기울기 계산량은 $O(N^2)$인 반면, 제안한 방식의 계산량은 O(N)이다. 성능 시험에서 제안한 방식의 EDEP와 그 기울기는 정상상태에서 기존의 블록 처리 방식과 동일한 추정결과를 나타냈다. 이러한 시뮬레이션 결과로부터, 제안한 방식이 실제 적응신호처리 분야에서 효과적인 방식임을 알 수 있다.

Assessments of RELAP5/MOD3.2 and RELAP5/CANDU in a Reactor Inlet Header Break Experiment B9401 of RD-14M

  • Cho Yong Jin;Jeun Gyoo Dong
    • Nuclear Engineering and Technology
    • /
    • 제35권5호
    • /
    • pp.426-441
    • /
    • 2003
  • A reactor inlet header break experiment, B9401, performed in the RD-14M multi channel test facility was analyzed using RELAP5/MOD3.2 and RELAP5/CANDU[1]. The RELAP5 has been developed for the use in the analysis of the transient behavior of the pressurized water reactor. A recent study showed that the RELAP5 could be feasible even for the simulation of the thermal hydraulic behavior of CANDU reactors. However, some deficiencies in the prediction of fuel sheath temperature and transient behavior in athe headers were identified in the RELAP5 assessments. The RELAP5/CANDU has been developing to resolve the deficiencies in the RELAP5 and to improve the predictability of the thermal-hydraulic behaviors of the CANDU reactors. In the RELAP5/CANDU, critical heat flux model, horizontal flow regime map, heat transfer model in horizontal channel, etc. were modified or added to the RELAP5/MOD3.2. This study aims to identify the applicability of both codes, in particular, in the multi-channel simulation of the CANDU reactors. The RELAP5/MOD3.2 and the RELAP5/CANDU analyses demonstrate the code's capability to predict reasonably the major phenomena occurred during the transient. The thermal-hydraulic behaviors of both codes are almost identical, however, the RELAP5/CANDU predicts better the heater sheath temperature than the RELAP5/MOD3.2. Pressure differences between headers govern the flow characteristics through the heated sections, particularly after the ECI. In determining header pressure, there are many uncertainties arisen from the complicated effects including steady state pressure distribution. Therefore, it would be concluded that further works are required to reduce these uncertainties, and consequently predict appropriately thermal-hydraulic behaviors in the reactor coolant system during LOCA analyses.

옥외형 피난계단의 풍압에 따른 내구성 검증을 위한 유동-구조 연성해석 (Flow-structure Interaction Analysis for Durability Verification by the Wind Force of Outdoor Evacuation Stairs)

  • 이석영
    • 에너지공학
    • /
    • 제29권3호
    • /
    • pp.97-102
    • /
    • 2020
  • 본 연구에서는 화재가 발생하였을 때 작동되는 옥외형 피난계단 구조물이 태풍에 따른 풍압이 작용하였을 때 내구성을 검증하기 위하여 단방향 유동-구조 연성해석을 진행하였다. 이를 위해, 피난계단 구조물 주위에 대한 유동장을 정상상태로 유동해석을 수행하였고, 이러한 해석결과를 구조해석을 위한 입력 데이터로 사용하여 구조응력, 변형량, 피로수명 등의 계산을 통해 내구성을 분석하였다. 유동해석 결과, 피난계단 구조물 형상에 따라 공기에 의한 유동 흐름이 다르게 나타났으며, 이러한 유동속도 분포는 구조물 표면에 전압력으로 작용하였다. 또한, 이러한 전압력에 의해 계산된 구조해석 결과, 최대응력값으로 계산된 안전율이 허용치 이상으로 나타났으며, 피로수명과 변형량 분석을 통해 내구성을 입증하였다.