• Title/Summary/Keyword: steady state distribution

Search Result 489, Processing Time 0.028 seconds

Exhaust Emission Characteristics from Heavy-duty Diesel Engine applicable to Prime Propulsion Engine for Marine Vessels (선박 주 추진기관으로 사용가능한 대형 디젤엔진의 배기가스 특성 분석)

  • Lee, Hyung-Min;Park, Rang-Eun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.484-489
    • /
    • 2012
  • The objective of this work presented here was focused on analysis of particulate matter and nitrogen oxide characteristics in ESC test mode from heavy-duty diesel engine installed on-road vehicles applicable to prime propulsion engine for marine vessels. The authors confirmed that a large quantity particulate matter were emitted in high power density condition, nitrogen oxide characteristics were dependent on exhaust gas temperature. Particulate matters were reduced by 1/100~1/1,000 times in post DPF with test modes but filtration efficiency was decreased in the engine power fluctuation. In the case of the high speed and power condition, the exhaust level of particulate matters was increased according to increment of temperature of gas flowing into DPF. The orders of magnitude for particle concentration levels from the analysis of size distribution of particulate matters of test engine was different. Both emitting nano-sized particles below 100nm regardless of DPF and non-DPF.

Effect of Very Low Levels of Lead in Diet and Exposure Time on the Accumulation and Distribution of Lead in Rat Organs (식이와 함께 섭취시킨 미량의 납 수준과 납 섭취기간이 납의 체내 축적 및 분포에 미치는 영향)

  • 이명희
    • Journal of Nutrition and Health
    • /
    • v.27 no.1
    • /
    • pp.12-22
    • /
    • 1994
  • Effects of very low level of lead in diet and exposure time on the accumulation and distribution in organs and tissues was investigated with growing rats. 21 days old Sprague-Dawley rats were exposed to lead for 7, 14 and 21 days by feeding of 0.03, 0.42, 0.92 and 1.46mg/kg Pb as Pb-acetate containing diet, respectively. Lead concentrations in blood, liver, kidney and bone exhibit a linear relationship with lead levels in diet. After 7 days of exposure, the greatest dose dependent accumulation of lead was found in kidney and followed in bone. However, after 14 and 21 days, the dose dependent accumlation of lead in bone was about two fold greater than that in kidney. The accumulation of lead in liver and blood was relatively low. As continuous exposure to lead, the concentrations of lead in liver, kidney, blood and intestinal tracts were rather not increased with exposure time. However, bone lead concentration was increased with exposure time by feeding of 0.92 and 1.46mg/kg Pb in diet, but not 0.42mg/kg. The lead concentration in gastrointestinal tracts tends also to increasing with lead levels in diet after 7 and 14 days of exposure. However, by 21 days of exposure the lead concentration revealed relatively constant value regardless of the dietary lead levels. It is concluded that the binding capacity of the lead in blood, liver, kidney and bone seems to be increased with increasing lead levels in diet. The lead concentration in these organs, with the exception of the lead in bone, seems, however, to be standing under steady state regulation by continued exposure with the same dietary lead level. Therefore, by chronic exposure condition with environmental relevant lead level bone might be a principle targe organ for lead and blood lead repesents better the current lead exposure than the lead body burden.

  • PDF

The Effect of Flushing Solutions on ElectroKinetic Remediation of Ferrous Soil Contaminated by Lead (납으로 오염된 철성분 함유토의 동전기 정화 특성에 세척제가 미치는 영향)

  • 김수삼;김병일;한상재;김정환
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.1
    • /
    • pp.54-62
    • /
    • 2004
  • In order to enhance the efficiency of removal a series of ElectroKinetic Remediation (EKR) tests on ferrous soil contaminated by lead are carried out using acids, chelates and surfactant as flushing agents. The test results indicate that pH in the electrolyte rapidly reached at steady state as the introduce of flushing solution of the lower pH, the type of flushing solution have no effect the distribution of electrical voltage within the sample but the increasing of solution concentration increases it at x/L=0.9. In the distribution of the residual lead in the sample SDS is the highest. Also, the removal efficiency for acetic acid concentration of 1mM Is the highest but the concentration of acetic acid significantly have no effect.

Acoustic Properties of Three-room Coupled System by Connected Two Apertures (개구부로 연결된 3중 커플룸의 음향특성)

  • Na, Hae Joong;Lim, Byoung-Duk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.3
    • /
    • pp.340-349
    • /
    • 2016
  • A coupled room system consists of adjacent rooms and apertures where the sound energy is exchanged between the two rooms. Acoustically, a coupled room system shows a non-exponential decay profile. Most of the related researches have been to analyze the acoustic properties of two-room coupled system so far whereas three-room coupled system were seldom studied. In this regard, this paper aims to analyse the distribution of sound pressure level, sound decay curve of three-room coupled system and sound energy flow between them by using the acoustic diffusion model and to further verify them through experiments. Firstly, the sound pressure level distribution and mean sound pressure level in the steady-state condition are analyzed at various frequencies and source locations. Good agreements are observed in both experiments and analysis results. Secondly, two double slope effect quantifiers of sound attenuation, LDT/EDT and LDT/T10 are compared at various frequencies and for different source locations. The result indicates that LDT/T10, less affected by the early reflection patterns than LDT/EDT, is more suitable to the analysis and experiments of a multi-slope sound decay curve. Lastly, the sound energy flow in each room is analyzed based on the acoustic diffusion model. After the early decay stage, the sound energy is observed to flow from the room with a long reverberation time to the room with a short one.

Calculation of a First-In-Man Dose of 7-O-Succinyl Macrolactin A Based on Allometric Scaling of Data from Mice, Rats, and Dogs

  • Noh, Keumhan;Kang, Wonku
    • Biomolecules & Therapeutics
    • /
    • v.25 no.6
    • /
    • pp.648-658
    • /
    • 2017
  • 7-O-Succinyl macrolactin A (SMA) exerts several pharmacological effects including anti-bacterial, anti-inflammation, and anti-cancer activities. Recently, SMA has been extensively evaluated as an anti-cancer drug. Thus, the objectives of the present study were to characterise the pharmacokinetics of SMA via both non-compartmental and compartmental analysis in mice, rats, and dogs, and to derive an appropriate first-in-man dose based on allometric scaling of the animal data. The time courses of plasma SMA concentrations after intravenous administration to rats and dogs were analysed retrospectively, as were data collected after intraperitoneal SMA injection in mice. Pharmacokinetic parameters were estimated via both noncompartmental and compartmental analysis, and were correlated with body weight and/or the potential maximum life-span. The clearance and distribution volume of SMA in humans were predicted, and a first-in-man dose proposed. A two-compartment model best described the time courses of SMA plasma concentrations after a saturation elimination process was applied to fit the dataset obtained from rats. Incorporation of the maximum potential life-span during allometric scaling was required to improve the estimation of human clearance. The SMA clearance and the distribution volume in the steady state, in a 70-kg adult male, were estimated to be 30.6 L/h and 19.5 L, respectively. To meet the area under the curve (AUC) required for anti-tumour activity, a dose of 100 mg (~1.5 mg/kg) was finally proposed as the first dose for a 70-kg human. Although toxicological profiles derived from non-clinical studies must be considered before any final decision is made, our work will facilitate clinical studies on SMA.

Thermo-Mechanical Stress Analysis of Power Generation Turbine Blades (발전용 터빈 블레이드의 열기계 응력 해석)

  • Kim, Jong-Un;Lee, Soo-Yong;Park, Jung-Sun;Lee, An-Sung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.6
    • /
    • pp.84-91
    • /
    • 2002
  • Temperature distribution in the GTD111 turbine blade used in power plaints is calculated by heat transfer analysis. Linear stress analysis of the turbine blade is also carried out under thermal loads and centrifugal forces. The numerical results of steady state heat transfer analysis slow that high temperature distribution occurs at the leading edge and tip section of the blade. The thermal stress result indicates that the equivalent stress at the tip of the pressure surface is higher than other sections of the blade. Maximum centrifugal stresses without the thermal effect occurs at the front of the fir tree. From the thermal-centrifugal stress analysis, maximum equivalent stress occurs at the fir tree. Stresses applied by the thermal loads and centrifugal forces are less than the yield stress. The GTD111 turbine blade is safe to be used in the power plants.

A Thermal Model for Silicon-on-Insulator Multilayer Structure in Silicon Recrystallization Using Tungsten Lamp (텅스텐 램프를 이용한 실리콘 재결정시의 SOI 다층구조에 대한 열적모델)

  • 경종민
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.5
    • /
    • pp.90-99
    • /
    • 1984
  • A onetimensional distribution of the temperature and the heat source in the SOI (silicon-on-insulator) multi-layer structure illuminated by tungsten lamps from both sides was obtained by solving the heat equation in steady state on a finite difference grid using successive over-relaxation method. The heat source distribution was obtained by considering such features as spectral components of the light source, multiple reflection at the internal interfaces, temperature and frequency dependence of the light absorption coefficient, etc. The front and back surface temperatures, which are boundary conditions for the heat equation, were derived from a requirement that they satisfy the radiation conditions. The radiation flux as well as the conduction flux was considered in modelling the thermal behaviour at the internal interfaces. Since the temperature and the heat source profiles are strongly dependent upon each other, the calculation of each profile was iterated using the updated profile of the other until they are consistent with each other. The experimental temperature at the front surface of the wafer as measured by Pyrometer was about 1200$^{\circ}$K, while the simulated temperature was 1120$^{\circ}$K.

  • PDF

Consistent thermal analysis procedure of LNG storage tank

  • Jeon, Se-Jin;Jin, Byeong-Moo;Kim, Young-Jin;Chung, Chul-Hun
    • Structural Engineering and Mechanics
    • /
    • v.25 no.4
    • /
    • pp.445-466
    • /
    • 2007
  • As the LNG (Liquefied Natural Gas) tank contains cryogenic liquid, realistic thermal analyses are of a primary importance for a successful design. The structural details of the LNG tank are so complicated that some strategies are necessary to reasonably predict its temperature distribution. The proposed heat transfer model can consider the beneficial effects of insulation layers and a suspended deck on temperature distribution of the outer concrete tank against cryogenic conditions simply by the boundary conditions of the outer tank model. To this aim, the equilibrium condition or heat balance in a steady state is utilized in a various way, and some aspects of heat transfer via conduction, convection and radiation are implemented as necessary. Overall thermal analysis procedures for the LNG tank are revisited to examine some unjustifiable assumptions of conventional analyses. Concrete and insulation properties under cryogenic condition and a reasonable conversion procedure of the temperature-induced nonlinear stress into the section forces are discussed. Numerical examples are presented to verify the proposed schemes in predicting the actual temperature and stress distributions of the tank as affected by the cryogenic LNG for the cases of normal operation and leakage from the inner steel tank. It is expected that the proposed schemes enable a designer to readily detect the effects of insulation layers and a suspended deck and, therefore, can be employed as a useful and consistent tool to evaluate the thermal effect in a design stage of an LNG tank as well as in a detailed analysis.

Different Pharmacokinetics of Aucubin in Rats of Carbon tetrachloride and D-Galactosamine-induced Hepatic Failure (사염화탄소와 갈락토사민 간장해 시의 오큐빈의 체내동태 차이)

  • 김미형;심창구;장일무
    • YAKHAK HOEJI
    • /
    • v.37 no.4
    • /
    • pp.383-388
    • /
    • 1993
  • Pharmacokinetics of aucubin, an irdoid glucoside, was compared in rats of experimental hepatic failure(EHF). EHF was induced by CCI$_{4}$ or D-galactosamine pretreatment. This work was designed to find out any differences in the pharmacokinetics of aucubin that may explain the different protective effect of aucubin on CCI$_{4}$- and galactosamine-induced EHF : aucubin reportedly protected CCI$_{4}$-inducing hepatotoxicity effectively, but did not for galactosamine-hepatotoxicity. EHF was induced by intraperitoneal injection Of CCI$_{4}$(0.9ml/kg) or galactosamine(250 mg/kg) to Wistar rats 24 hr before the pharmacokinetic study. The rats were fasted during the 24 hr. Aucubin was iv injected at a dose of 15 mg/kg and the plasma aucubin was assayed by HPLC. There were no significant differences in the pathophysiologies(body weight, liver weight, GTP, hematocrit, blood cell distrbution and plasma protein binding of aucubin) between the two EHF models except GOP which was significantly (p<0.05) higher in CCI$_{4}$-than in galactosamine-EHF. On the other hand, pharmacokinetics of aucubin such as total cleatance(CL$_{t}$), distribution volume at steady-state(Vd$_{ss}$), and mean residence time(MRT) differed significantly(p<0.05) between the models : for example, CL$_{t}$ was increased two fold by CCI$_{4}$, but not by galaclosamine ; Vd$_{ss}$, in galactosamine-EHF was higher than that in CCI$_{4}$-EHF ; MRT was decreased by CCI$_{4}$, but increased conversely by galactosamine. The increase of CL$_{t}$(and decrease of MRT) in rats of CCI$_{4}$-EHF was contrary to the general expectation for the hepatic failure : most of the hepatic failures have been known to decrease CL$_{t}$ of the administered drugs. Whether the difference in the pharmacokinetics is responsible for the different protective effect of aucubin against the two EHF models is of interest. However, much more studies on biliary excretion, urinary excretion, and hepatic uptake in cellular level should be preceded before any conclusions are made on the role of different pharmacokinetics on the different pharmacology of aucubin.

  • PDF

Biofilter Treatment of Waste Air Containing Malodor and VOC: 1. Pressure Drop and Microbe-population Distribution of Biofilter with Improved Design (악취 및 VOC를 함유한 폐가스의 바이오필터 처리: 1. 개선된 바이오필터설계에 의한 압력강하와 미생물 population 분포)

  • Lee, Eun Ju;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.51 no.1
    • /
    • pp.127-135
    • /
    • 2013
  • In this study, both pressure drop and microbe-population-distribution were observed while running a novel biofilter system with improved design in which the biofilter system is composed of two, upper and lower biofilters with both equal feed-rates of up-flow and down-flow, respectively. Then they were compared with the pressure drop and microbe-population-distribution observed in a conventional biofilter of the same effective volume with unidirectional flow. The pressure drop-value of biofilter system with improved design turned out to be less at the incipient stage of run or steady-state long term operation by more than 40~80% of that of the conventional biofilter. The microbe-population-distribution was observed to be lower and higher at higher and lower column of biofilter, respectively, for both the conventional biofilter and the biofilter system with improved design. The microbe-media of waste-tire crumb showed much greater CFU counts than GAC. In the biofilter system with improved design, the $bottom{\rightarrow}up$ feeding of waste air showed greater microbe-population growth than the $top{\rightarrow}down$ feeding for both the microbe-media of waste-tire crumb and GAC. However, it was more prominent for the former than the latter. Comparing the microbe-population-distributions of both of the conventional biofilter and the biofilter system with improved design, the microbe-population of latter was distributed ca. 15 and 2.5 times more evenly for GAC and the media of waste-tire crumb, respectively, than that of former.