• Title/Summary/Keyword: steady state distribution

Search Result 488, Processing Time 0.03 seconds

Analysis of Temperature Distribution of Solid and Gas in the Rotary Cooler (회전냉각기에서 고체와 가스의 온도분포해석)

  • 이만승;최주석;전철근
    • Resources Recycling
    • /
    • v.11 no.3
    • /
    • pp.25-30
    • /
    • 2002
  • Heat transfer occurring in the rotary cooler was analyzed by applying a one-dimensional steady state. The temperature of inlet gas and the measured temperature of outlet gas were used as boundary conditions. Axial temperature distribution of solid, gas and wall were calculated by solving two differential equations and two algebraic equations under the constraint of two point boundary conditions and operating conditions. The temperatures of outer wall calculated in this study were in good agreement with those measured from running rotary cooler.

Effect of Water Demand Patterns on the Water Distribution System with Multi-Reservoirs (다점주입계(多点注入系) 배수관망(配水管網)에 미치는 상수수요형태(上水需要形態)의 영향(影響))

  • Hyun, In Hwan;Wi, Wuk Ryang;Lee, Sang Jun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.3
    • /
    • pp.51-58
    • /
    • 1997
  • Determining sizes and the locations of reservoirs in the water distribution system(WDS) with multi-reservoirs is much difficult than that with single reservoir. The extended period simulation(EPS) models provide more comprehensive analysis of water distribution systems than the steady-state models can do. Therefore, EPS models should be applied to the WDS with multi-reservoirs. This study is to investigate the variations of required reservoir sizes and residual nodal pressures according to reservoir locations. In this study, EPS was applied to analyze an artificial and a real WDS under several water demand patterns. As a result, it was found that water demand patterns make no significant differences in the determining of the reservoir size, if they have similar peaking factors. And the variations of the peaking factor should be carefully checked in the design and the analysis of the WDS with multi-reservoirs, because the peaking factor itself will affect the minimum allowable sizes of reservoirs in those systems.

  • PDF

Decrease of Distribution Volume of a Basic Drug in Rats of Experimental Renal Failure (신장해에 의한 염기성약물의 분포용적감소예와 그 기전)

  • 심창구
    • YAKHAK HOEJI
    • /
    • v.27 no.1
    • /
    • pp.21-28
    • /
    • 1983
  • Distribution volume (Vd$_{ss}$ ) of a model basic drug, tetraethylammonium bromide (TEA) at a steady-state decreased sinificantly in glycerol and uranium-renal failure rats. Assuming carrier-mediated transport of TEA into tissues, the theoretical $Vd_{ss}$ of TEA decreases in an exponential way as the plasmal concentration of TEA increases. The relationship between $Vd_{ss}$ and plasma concentration of TEA in the experimental renal failure (ERF)-rats was similar. Therefore, the decrease in $Vd_{ss}$ of TEA in the ERF-rats seemed to be due to the saturation of the carrier system that are responsible for the tissue distribution of TEA, by the elevated plasma concentration of TEA in the ERF-rats. ERF was induced to rats with glycerol, folate, salicylate, uranium and gentamicin, respectively..

  • PDF

A Numerical Study on the Blood Flow through a Disc Type Heart Valve (원판형 심장판 주위의 혈액 흐름에 대한 수직 해석)

  • 박영필;이신재
    • Journal of Biomedical Engineering Research
    • /
    • v.2 no.2
    • /
    • pp.89-102
    • /
    • 1981
  • The recirculating flows which occur in the prosthetic heart valve have been known to cause several diseases in the human body. And the recent studies show that the shear stress at the wall of the artery is also very important factor in the formation of thrombus. And many studies knave been devoted in obtaining more information about the blood flow through the prosthetic heart valve. In this Paper, the steady axisymmetric flow through the Disc-Type Heart Valve is studied by using the numerical method. The geometry of the Disc-Type Heart Valve is simplified, and the flow is assumed to be steady axisymmetric flow. The vorticity transport equation derived from the Wavier-Stoke's equation is used as the governing equation, and the explicit finite difference method is used to obtain the steady state solution. The results for several Reynolds numbers show that the recirculating flow becomes large as the Remolds number increases. Furthermore, it can be shown that the magnitudes of the vorticity and the stresses are also increased with the Reynolds number, but there is only a little change in their configurations of distribution and in their positions of maximum values.

  • PDF

Analysis of Coating Uniformity through Unsteady and Steady State Computer Simulation in Slot Coating (슬롯코팅에서 정상 및 비정상상태 컴퓨터해석을 통한 코팅의 균일성 분석)

  • Woo, Jeong-Woo;Sung, Dal-Je;Lyu, Min-Young
    • Polymer(Korea)
    • /
    • v.38 no.5
    • /
    • pp.640-644
    • /
    • 2014
  • As a process of plat panel display production, slot coating is widely used for the coating of photoresist on a wide glass substrate. A uniform coating thickness is important, and the coating uniformity is divided into nozzle and machine directions. The machine and nozzle directions coating uniformities are influenced by the operation condition of coater and flow uniformity inside the die, respectively. Non-uniform coating during steady coating process occurs according to those factors, however, non-uniform coating along the machine and nozzle directions has been observed at the beginning of coating by unsteady flow. In this study, steady and unsteady state flow simulations have been performed and compared with experiment to examine the causes of non-uniform coating. Computational results exhibited that it took a time to get a uniform pressure distribution at whole inside the die, and during this period of time edge regions showed lower exit velocity compared with center region. Subsequently edge regions had thinner coated layers than center region. However edge regions showed higher exit velocity than center region after steady state, and this made edge regions had thicker coated layer than center region.

A Study on the Use of Low-Grade Domestic Anthracite by Anthracite - Bituminous Coal Blend Combustion in a Fluidized Bed Combustor (유동층 연소로에서 유.무연탄 혼합 연소법을 이용한 국내산 저질 무연탄의 활용에 관한 연구)

  • 정종현;조상원
    • Journal of Environmental Science International
    • /
    • v.6 no.3
    • /
    • pp.267-276
    • /
    • 1997
  • It has been studded that combustion and the production of air pollution of anthracite - bituminous coal blend In a fluidized bed coal combustor, The objects of thIns study were to investigate mixing characteristics of the particles as well as the combustibility of the low grade domestic anthracite coal and Imported h19h calorific bltununous coal in the fluidized bed coal combustor. They were used as coal samples ; the domestic low grade anthracite coal with heating value of 2,010kca1/kg and the Imported high grade bituminous coal with beating value of 6,520kca1/kg. Also, the effects of air flow rate and anthracite fraction on the reaching time of steady state condition have been studied. The experimental results are presented as follows. The time of reaching to steady state was affected by the temperature variation. The steady state time was about 120 minute at 300sc1h which was the fastest. It has been found that $O^2$ and $CO^2$ concentration were reached steady state at about 100 minute. It has been found that $O^2$ concentration decreased and $CO^2$ concentration increased as the height of fluidlzed bed Increased. It was found that splash zone was mainly located from 25cm to 35cm above distributor. Also, as anthracite traction Increased, the mass of elutrlatlon particles Increased, and $CO^2$ concentration decreased. As gk flow rate Increased,$O^2$ concentration decreased and $CO^2$ concentration increased. Regardless of anthracite fraction and flow rate, the uncombustible weight percentage according to average diameter of elutriation particles were approldmately high In the case of One Particles. As anthracite traction and k now rate Increased, elutriation ratio Increased. As anthracite fraction was increased, exit combustible content over feeding combustible content was Increased. Regardless of anthracite fraction, size distribution of Ued material from discharge was almost constant. Over bed temperature 85$0^{\circ}C$ and excess air 20% , the difference of combution efficiencies were little. It is estimate that the combustion condition In anthracite-bituminous coal blend combustion is suitable at the velocity 0.3m/s, bed temperature 85$0^{\circ}C$, the excess air 20%.

  • PDF

Analysis of Output Irregularity from the Transient Behavior of Bundle in a Flow Field (유동계 내 집속체의 과도적 거동에 따른 출력 불균제 해석)

  • Huh Y.;Kim J.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.965-968
    • /
    • 2005
  • Roll drafting operation causes variations in the linear density of bundles because the bundle flow cannot be controlled completely by roll pairs. Defects occurring in this operation bring about many problems successively in the next processes. In this paper, we attempt to analyze the draft dynamics and the linear density irregularity based on the governing equation of a bundle motion that has been suggested in our previous studies. For analyzing the dynamic characteristics of the roll drafting operation, it is indispensable to investigate a transient state in time domain before the bundle flux reaches a steady state. However, since governing equations of bundle flow consisting of continuity and motion equations turn out to be nonlinear, and coupled between variables, the solutions for a transient state cannot be obtained by an analytical method. Therefore, we use the Finite Difference Method(FDM), particularly, the FTBS(Forward-Time Backward-Space) difference method. Then, the total equations system yields to an algebraic equations system and is solved under given initial and boundary conditions in an iterative fashion. From the simulation results, we confirm that state variables show different behavior in the transient state; e.g., the velocity distribution in the flow field changes more quickly the linear density distribution. During a transient flow in a drafting zone, the output irregularity is influenced differently by the disturbances, e.g., the variation in input bundle thickness, the drafting speed, and the draft ratio.

  • PDF

The Effect of Seasonal Rhythm on the Gentamicin Pharmacokinetics in Healthy Volunteers (계절리듬이 겐타마이신의 약물동태에 미치는 영향)

  • Choi, Jun Shik;Kim, Jin;Baek, Chae Sun;Do, Nam Yong;Kim, Sung Hwan;Park, Young Jin
    • Korean Journal of Clinical Pharmacy
    • /
    • v.8 no.2
    • /
    • pp.89-94
    • /
    • 1998
  • Seasonal rhythmic changes in gentamicin pharmacokinetics was evaluated in 10 healthy male volunteers after single intravenous 80 mg administration of gentamicin at 9:00 a.m. during summer and winter. The mean terminal half-life and AUC of gentamicin were $3.56\pm0.14\;hr\;and\;25.03\pm2.84\;{\mu}g/ml{\cdot}hr$ in winter and $3.08\pm0.41\;hr\;and\;21.84\pm2.51\;{\mu}g/ml{\cdot}hr$ in summer. The mean total body clearance $(CL_t)$ and elimination rate constant $(k_{10})$ of gentamicin was $3.17\pm0.43\;L/hr,\;0.458\pm0.06\;hr^{-1}\;in\;winter\;and\;3.66\pm0.45\;L/hr,\;0.561\pm0.07\;hr^{-1}$ in summer, The mean volumn of distribution $(V_{dss})$ of gentamicin at steady state was $12.65\pm1.09$L in winter and $12.39\pm1.25$ L in summer. Serum concentrations of gentamicin in winter were increased significantly during 4-8 hr (p<0.05) compared to those of gentamicin in summer. The elimination rate constant $(k_{10})$ of gentamicin in winter was decreased significantly $(p<0.05)$ compared to that of gentamicin in summer. The mean volume of distribution at steady state $(V_{dss})$, AUC, mean total body clearance ($CL_t$) and terminal half-life of gentamicin in the winter were increased but were not significant. The mean intrasubject fluctuations in terminal half-life, AUC and $CL_t$ between winter and summer were 8.2, 11.0 and $6.0\%$ respectively.

  • PDF

Groundwater Flow Model of Igsan Area (익산 지역의 지하수 유동 모델)

  • Hamm, Se Yeong;Kim, Youn Ki
    • Economic and Environmental Geology
    • /
    • v.22 no.4
    • /
    • pp.381-393
    • /
    • 1989
  • Hydrogeological modelling was performed to evaluate groundwater flow system in Igsan Area. The study area extends over $790km^2$. The geology consists of Jurassic Daebo granite and gneissose granite and Precambrian metamorphic rocks. The capability of pumping yield is the highest in gneissose granite region among them due to comparatively thick weathered zone with thickness ranging from 10m to 25m. The Colorado State University Finite Difference Model was used for the model simulation. The model was divided into 28 rows and 31 columns with variable grid spacing. The model was calibrated under steady-state and unsteady-state conditions. In the steady-state simulation, the model results were compared with measured water table contours in September 1985 with determining hydraulic conductivities and net recharge rates during rainy season. Unsteady state simulation was done to know the aquifer response due to groundwater abstraction. The non- steady state calibration was conducted to determine the distribution and magnitudes of specific yields and discharge/recharge rates during dry season as matching water level altitudes in May 1986. The calibrated model was used to simulate water level vaiation caused by groundwater withdrawal and natural recharge from 1 October, 1985 until 30 September, 1995. The calibrated model can be used to groundwater development schemes on regional groundwater levels, but it cannot be used to simulate local groundwater level change at a specific site.

  • PDF

Hydro-elastic analysis of marine propellers based on a BEM-FEM coupled FSI algorithm

  • Lee, Hyoungsuk;Song, Min-Churl;Suh, Jung-Chun;Chang, Bong-Jun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.3
    • /
    • pp.562-577
    • /
    • 2014
  • A reliable steady/transient hydro-elastic analysis is developed for flexible (composite) marine propeller blade design which deforms according to its environmental load (ship speed, revolution speed, wake distribution, etc.) Hydro-elastic analysis based on CFD and FEM has been widely used in the engineering field because of its accurate results however it takes large computation time to apply early propeller design stage. Therefore the analysis based on a boundary element method-Finite Element Method (BEM-FEM) Fluid-Structure Interaction (FSI) is introduced for computational efficiency and accuracy. The steady FSI analysis, and its application to reverse engineering, is designed for use regarding optimum geometry and ply stack design. A time domain two-way coupled transient FSI analysis is developed by considering the hydrodynamic damping ffects of added mass due to fluid around the propeller blade. The analysis makes possible to evaluate blade strength and also enable to do risk assessment by estimating the change in performance and the deformation depending on blade position in the ship's wake. To validate this hydro-elastic analysis methodology, published model test results of P5479 and P5475 are applied to verify the steady and the transient FSI analysis, respectively. As the results, the proposed steady and unsteady analysis methodology gives sufficient accuracy to apply flexible marine propeller design.