• Title/Summary/Keyword: steady state condition

Search Result 678, Processing Time 0.031 seconds

Exergy analysis of heat pump in consideration of its dynamic response (동특성을 고려한 열펌프의 엑서지 해석)

  • 장기태;남관우;정상권
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.2
    • /
    • pp.155-164
    • /
    • 1998
  • A multi-type heat pump controls the mass flow rate of the working fluid to cope with variable heat loads when it is under dynamic load condition. This paper describes the exergy analysis associated with the dynamic response of heat pump. First, a basic heat pump cycle is examined at steady state to show the general trends of exergy changes in each process of the cycle. Entropy generation issue in the exchangers is discussed to optimize the heat pump cycle. Second, the performance of the inverter-driven heat pump is compared to that of the conventional one when the heat load is variable. Third, the exergy destruction rate associated with the ON/OFF operations of the heat pump is calculated by simulating the thermodynamic states of the condenser and the evaporator. The inefficiency of the ON/OFF operation during the transient period is quantitatively revealed by the exergy analysis.

  • PDF

A Study on the Transient Flow Process in a Vacuum Ejector-Diffuser System (진공 이젝터-디퓨져 시스템내의 비정상 유동 과정에 관한 연구)

  • Vincent, Lijo;Kim, Heuy-Dong;Setoguchi, T.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.299-302
    • /
    • 2009
  • The objective of the present study is to analyze the transient flow through theejector system with the help of a computational fluid dynamics (CFD) method. An attempt is made to investigate the interesting and conflicting phenomenon of the infinite entrainment into the primary stream without an infinite mass supply from the secondary chamber. The results obtained show that the one and only condition in which an infinite mass entrainment can be possible in such types of ejectors is the generation of a re-circulation zone near the primary nozzle exit. The flow in the secondary chamber attains a state of dynamic equilibrium of pressures at the onset of the recirculation zone. A steady flow in the ejector system is valid only after this point.

  • PDF

Shape Optimization of Energy Flow Problems Using Level Set Method (레벨 셋 기법을 이용한 에너지 흐름 문제의 형상 최적화)

  • Seung-Hyun, Ha;Seonho, Cho
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.10a
    • /
    • pp.411-418
    • /
    • 2004
  • Using a level set method we develop a shape optimization method applied to energy flow problems in steady state. The boundaries are implicitly represented by the level set function obtainable from the 'Hamilton-Jacobi type' equation with the 'Up-wind scheme.' The developed method defines a Lagrangian function for the constrained optimization. It minimizes a generalized compliance, satisfying the constraint of allowable volume through the variations of implicit boundary. During the optimization, the boundary velocity to integrate the Hamilton-Jacobi equation is obtained from the optimality condition for the Lagrangian function. Compared with the established topology optimization method, the developed one has no numerical instability such as checkerboard problems and easy representation of topological shape variations.

  • PDF

Second order integral sliding mode observer and controller for a nuclear reactor

  • Surjagade, Piyush V.;Shimjith, S.R.;Tiwari, A.P.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.3
    • /
    • pp.552-559
    • /
    • 2020
  • This paper presents an observer-based chattering free robust optimal control scheme to regulate the total power of a nuclear reactor. The non-linear model of nuclear reactor is linearized around a steady state operating point to obtain a linear model for which an optimal second order integral sliding mode controller is designed. A second order integral sliding mode observer is also designed to estimate the unmeasurable states. In order to avoid the chattering effect, the discontinuous input of both observer and controller are designed using the super-twisting algorithm. The proposed controller is realized by combining an optimal linear tracking controller with a second order integral sliding mode controller to ensure minimum control effort and robustness of the closed-loop system in the presence of uncertainties. The condition for the selection of gains of discontinuous control based on the super-twisting algorithm is derived using a strict Lyapunov function. Performance of the proposed observer based control scheme is demonstrated through non-linear simulation studies.

Modeling of Groundwater Flow Using the Element-Free Galerkin (EFG) Method

  • Park, Yu-Chul;Darrel I. Leap
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.77-80
    • /
    • 2001
  • The element-free Galerkin (EFG) method is one of meshless methods, which is an efficient method of modeling problems of fluid or solid mechanics with complex boundary shapes and large changes in boundary conditions. This paper discusses the theory of the EFG method and its applications to modeling of groundwater flow. In the EFG method, shape functions are constructed based on the moving least square (MLS) approximation, which requires only set of nodes. The EFG method can eliminate time-consuming mesh generation procedure with irregular shaped boundaries because it does not require any elements. The coupled EFG-FEM technique was introduced to treat Dirichlet boundary conditions. A computer code EFGG was developed and tested for the problems of steady-state and transient groundwater flow in homogeneous or heterogeneous aquifers. The accuracy of solutions by the EFG method was similar to that by the FEM. The EFG method has the advantages in convenient node generation and flexible boundary condition implementation.

  • PDF

Rat Skin Permeation Characteristics of L-cystein to Common Permanent Wave Drug In Vitro (상용 퍼머넌트 웨이브 약제인 L-cystein의 랫드 피부 투과 특성)

  • 김용렬;윤철훈;김낙주
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.4
    • /
    • pp.73-78
    • /
    • 2001
  • Hair will be persuit of beautifulness of human being in various permanent wave by many kinds of its drugs. Skin is based upon the hair which enroll the body of high living animals and have multiple membrane structure In this study used rat the effects of commercial permanent wave products to skin which are composed with L- cysteine and bases Results are as follow: the content of penetration 4 hors later with steady state and no significant changeable after 20 hours later. In cysteine groups, lag time and permeability coefficient of healthy skin is 2.22hr and 0.13$\mu\textrm{g}$/㎥ hr, lag time and permeability coefficient of old skin is 4.01 hr and 0.108 $\mu\textrm{g}$/㎥ hr . In conclusion of study lag time and permeability coefficient in old skin and wounded skin are faster than healthy skin. We notified that fine rinkle and rash of skin were changeable in the case of treating with permanent wave drugs than normal skin.

  • PDF

단일 생물막 반응기에서 역세척과 다공성 생물막 담체가 질소제거에 미치는 영향

  • Lee, Su-Cheol;Yu, Ik-Geun;Kim, Dong-Jin
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.451-454
    • /
    • 2000
  • This study was carried out to investigate the effects of hydraulic backwash load and porous ceramic media on the biological nitrogen removal efficiencies of a biological aerated filter. An upflow anoxic-oxic biological aerated filter(AO-BAF) with porous ceramic media can remove nitrogen by nitrification and denitrification in single unit. After the AO-BAF backwash, nitrogen removal efficiency was lowest and gradually increased to the steady state. Nitrification efficiency, however, showed the opposite result. It is likely that the biofilms are exposed to aerobic condition as the excess biofilms were sloughed off by backwashing

  • PDF

Assessment of lining load for drainage type cable tunnel considered water-passing capacity of tunnel filter material (부직포 통수능을 고려한 배수형 전력구터널의 라이닝 하중산정)

  • Kim, Dae-Hong;Kim, Kyoung-Yul;Lee, Dae-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1369-1376
    • /
    • 2005
  • In case of the drainage type tunnel, the residual water pressure is likely to act on the tunnel lining due to the decrease of water-passing capacity of the filter material. Therefore, this study discussions a method to predict the lining load with the consideration of water passing capacity of the filter material through the literature review and numerical analysis. It is expected from the results of case studies that the design load acting on the concrete lining in the drainage type tunnel could be assumed to be about 50% of the hydrostatic water pressure in steady-state ground-water condition.

  • PDF

The Enhancement of Continuation Power Flow at Minimal computational Costs (고속 계산을 위한 연속 조류 계산 시스템의 향상)

  • Park, Min-Seok;Song, Hwa-Chang;Lee, Byong-Jun;Kwon, Sae-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.13-16
    • /
    • 2000
  • Continuation power flow has been developed to remove the ill-condition problem caused by singularity of power flow Jacobian at and near steady-state voltage instability point in conventional power flow. When solving large-scale power transmission systems, continuation power flow require large computational costs. Therefore, technique to improve the speed of continuation power flow system was required. In this paper Decoupled Power Flow Method (DPFM), Enhanced Decoupled Power Flow Method (EDPFM), Robust Fast Decoupled Power Flow Method (RFDPFM) are applied to continuation power flow algorithm to improve the speed of continuation power flow system.

  • PDF

Studies on Dynamic Responses of Nuclear Power Plant during Frequency and Voltage Decays (계통주파수 및 전압 저하시 원자력발전소 응동 분석)

  • Cho, Sung-Don;Kang, In-Su
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1221-1223
    • /
    • 1999
  • The safety loads in a nuclear power plant perform a critical function to plant safety. The design of the electrical auxiliary system should ensure the availability and adequacy of the power supply, and therefore, the frequency and voltage relaying schemes should be installed on the system to monitor and protect against the degraded system condition. If unforeseen contingencies degrade the switchyard frequency and voltage to below the minimum values, the safety related bus should properly be transferred to alternate power source. This paper presents guidelines associated with the protection of nuclear power plants during frequency/voltage decay and the steady-state and dynamic analysis of auxiliary power system that should be performed to support the degraded voltage relay(second level undervoltage relay) setting.

  • PDF